• Title/Summary/Keyword: Heating Unit

Search Result 495, Processing Time 0.023 seconds

Comparative Study of Celadon Shards from Gangjin and Buan Kiln Sites (강진과 부안 청자 도편의 비교연구)

  • No, Hyunggoo;Kim, Soomin;Kim, Ungsoo;Cho, Wooseok;Han, Junghwa
    • Journal of the Korean Ceramic Society
    • /
    • v.52 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • Celadon shards from Gangjin and Buan were analyzed for their color, chemistry and microstructures. They exhibited similar chromatic characteristics in a $CIEL^*a^*b^*$ analysis. All of the glazes assessed showed comparable compositional areas, while the bodies from Gangjin shards had higher $RO_2$ concentrations. A high degree of similarity was also noted in the microstructures of the glaze and bodies from both regions. Anorthite crystals appeared in the glaze layer, and phase separation behavior developed around these crystals. This may have been caused by the glaze chemistry and the sintering process given the lengthy heating and cooling time. A Raman analysis indicated higher isolated $SiO_4$ unit ($Q_0$) values for the Buan samples. This can stem from the higher firing temperature or the longer sintering process.

A Study on Using Incineration Heat of Municipal Solid Wastes - Case Study of Taegu metropolitan city - (생활(生活)쓰레기 소각열(燒却熱) 이용실태(利用實態)에 관(關)한 연구(硏究) - 대구광역시(大邱廣域市)를 중심(中心)으로 -)

  • Hong, Won-Hwa;Yi, Gang-Kook;Lee, Ji-Hee
    • KIEAE Journal
    • /
    • v.1 no.1
    • /
    • pp.45-52
    • /
    • 2001
  • This study aims to make a fundamental data for a policy-making decision in treatment and disposal of municipal solid wastes and presents a research data on the discharge properties of municipal solid wastes and making a unit of them in the Taegu metropolitan city. The results can be summarized as follows; survey the discharge properties of municipal solid wastes, calorific values and to present a research-data in supplying incineration-heat of wastes with the area of Sung-seo in Taegu. So, using fundamental data for planning and running wastes-incineration plants as well as trying to make better Urban Environmental Infra-structure. The results are obtained from the study. 1) The proportion of combustible wastes in Taegu increased from 89.6% to 94.47% during 1993~2000. However, the proportion of incombustibles decreased from 10.4% to 5.53% during 1993~2000. 2) The value of representative properties is about 1500~2000kcal/kg. So we can expect that it should be made use of energy-resources positively. 3) The heat from Sung-seo wastes-incineration plants is used to produce electronic-energy for wastes-incineration plants in summer season. The heat from Sung-sea wastes-incineration plants is in charge of 27% which of supplying the area of Sung-seo with district heating energy in winter season.

  • PDF

Degradation Properties and Production of Fuels from Cellulose - Solvolysis - (셀룰로오스의 분해특성 및 연료물질 생성[II] - 용해분해 반응 -)

  • Lee, Jong-Jib;Lee, Byung-Hak
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.16 no.2
    • /
    • pp.159-169
    • /
    • 2005
  • Cellulose, consisted of 45 wt% in wood, is usable as fuels and heavy oil additives if depolymerized to monomer unit, because the chemical structures are similar to high octane materials found in gasoline. In this study, thermochemical degradation by solvolysis reaction of cellulose such as the effect of reaction temperature, reaction time and type of solvent on conversion yield and degradation products were investigated. It was found that the effectiveness of the solvent on the sovolysis reaction was as follows; acetone>n-butanol>tetralin. When acetone was used as a solvent, the highest cellulose conversion was observed to be 91.8% at 500$^{\circ}C$, 40min. Combustion heating value of liquid products from thermochemical conversion processes was in the range of 7,330${\sim}$7,410cal/g. The energy yield and mass yield in acetone-solvolysis of cellulose was as high as 66.8% and 37.0 g oil/100g raw material after 40min of reaction at 400$^{\circ}C$. Various aliphatic and aromatic compounds were detected in the cellulose solvolysis products. The major components of the solvolysis products, that could be used as fuel, were mesityl oxide, mesitylene, isophorone.

Thermal Properties of Semiconductive Materials(Shield) by Sonic Impurities in Carbon Black (카본블랙내 이온성 불순물들에 따른 반도전 재료(층)의 열적특성)

  • Lee Yong-Sung;Choi Yong-Sung;Park Dae-Hee;Lee Kyoung-Yong
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.4
    • /
    • pp.149-153
    • /
    • 2005
  • We have investigated thermal properties showed by changing the content of carbon black which is the component parts of semiconductive shield in underground power transmission cable. Specimens were made of sheet with the nine of those for measurement. Heat capacity (${\Delta}$H), glass transition temperature (Tg) and melting temperature (Tm) were measured by DSC (Differential Scanning Calorimetry). The ranges of measurement temperature were from -100($^{\circ}C$) to 100($^{\circ}C$), and heating rate was 4($^{\circ}C$/min). And then thermal diffusivity was measured by LFA 447. The dimension of measurement temperature was 25[$^{\circ}C$]. Glass transition temperature of specimens was showed near -25[$^{\circ}C$] and the heat capacity and the melting temperature from the DSC results were simultaneously decreased according to increasing the content of carbon black, while thermal diffusivity was increased according to increasing the content of carbon black. Because ionic impurities of carbon black having Fe, Co, Mn, Al and Zn are rapidly passed kinetic energy increasing the number of times breaking during the unit time with the near particles according to increasing vibration of particles by the applied heat energy.

Characteristic Evaluation of RDF for the Combined Drying Produced by Weight Mixing Ratio Use Chemical Wastewater Sludge and Anthracite Coal (화학폐수슬러지와 무연탄을 이용한 복합건조공정의 조사시간에 따른 고형연료의 특성 평가)

  • Lee, Seung-Chul;Jung, Jin-Hee;Lee, Jun-Hee
    • Journal of Environmental Science International
    • /
    • v.25 no.3
    • /
    • pp.417-424
    • /
    • 2016
  • The objective of this study was to evaluate the microwave drying characteristics of mixtures of chemical wastewater sludge (70~90%) and anthracite coal (10~30%) with respect to physical and economic factors such as mass, volume reduction, moisture content, drying rate and heating value when the wastes were dried at different weight mixing ratio and for different microwave irradiation time. The drying process were carried out in a microwave oven, the combined drying process with a 2,450 MHz frequency and 1 kW of power. Maximum dry rates per unit area on the microwave drying of mixtures with chemical wastewater sludge and anthracite coal were $35.5kg\;H_2O/m^2{\cdot}hr$ for Cs90-Ac10; $40.1kg\;H_2O/m^2{\cdot}hr$ for Cs80-Ac20 and $35.0kg\;H_2O/m^2{\cdot}hr$ for Cs70-Ac30. The result clearly indicated that moisture can be effectively and inexpensively removed from the wastes through use of the microwave drying process.

Study on the Thermal Deformation of the Air-conditioner Indoor Unit Assembly Using 3D Measurement and Finite Element Analysis (에어컨 실내기 사출 조립품의 열 변형 3D측정과 유한요소해석)

  • Hong, Seokmoo;Hwang, Jihoon;Kim, Cheulgon;Eom, Seong-uk
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.2
    • /
    • pp.251-255
    • /
    • 2015
  • Thermal deformation, such as bending and twisting, occurs among the polymer parts of air-conditioner indoor units because of repetitive temperature change during heating operation. In this study, a numerical method employing finite-element analysis to efficiently simulate the thermal deformation of an assembly is proposed. Firstly, the displacement of an actual assembly produced by thermal deformation was measured using a 3D optical measurement system. The measurement results indicated a general downward sag of the assembly, and the maximum displacement value was approximately 1 mm. The temperature distribution was measured using a thermographic camera, and the results were used as initial-temperature boundary conditions to perform temperature-displacement analysis. The simulation results agreed well with the measured data. To reduce the thermal deformation, the stiffness increased 100%. As the results, the maximum displacement decreased by approximately 5.4% and the twisting deformation of the holder improved significantly.

Consideration of Cost Allocation Methodology on Cogeneration (열병합발전에서 비용배분 방법론의 고찰)

  • Kim, Deok-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1197-1202
    • /
    • 2009
  • Cost allocation on cogeneration is a methodology dividing the input of common cost to electricity cost and heat cost. In the cost allocation methodology of the electricity and heat on a cogeneration, there are energy method, work method, proportional method, benefit distribution method, reversible work method, various exergetic methods, and so on. In previous study, various cost allocation methodologies have been applied and analyzed on a gas-turbine cogeneration producing the 33.1 MW of electricity and the 32.2 Gcal/h of heat, a steam-turbine cogeneration producing the 22.2 MW of electricity and the 44.3 Gcal/h of heat, and combined-cycle cogeneration producing the 314.1 MW of electricity and the 279.4 Gcal/h of heat. In this study, we integrately analyze the results of previous studies and examine the generality and rationality each methodology. Additionally, a new point of view on the values of alternative electricity efficiency and alternative heat efficiency in the previous methodologies was proposed. As the integrated result, we conclude that reversible work method of various common cost allocation methodologies is most rational.

  • PDF

Analysis of City Level Energy Usage in Busan (부산시 도시차원에서의 에너지 사용 현황 분석)

  • Kim, Nam-Wook;Hong, Jin-Young;Park, Yool
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1185-1190
    • /
    • 2009
  • Korea is an industrial country that overspends energy and has a policy that is more focused on a supply side. When an urban developmental program is to set up, surveys are carried out only with the respect to electricity, telecommunication, gas, and heating sources. Based on the existing survey results, the problems related to the supply side are being dealt with more importantly and the quantities of those supplies are estimated only by each energy source. The aim of this study is to provide basic information on energy consumption patterns of a diverse comsumer groups including industry, transportation, commerce, public and household to plan diverse energy policies. Through this basic information, it may be possible to analyze the energy consumption pattern by each consumer group and provide data for setting up efficient energy policies by the government. The energy consumption map that are analyzed and developed by the data obtained from Busan municipal area will be deposited and used as a part of the national energy statistics.

  • PDF

SMA(SHAPE MEMORY ALLOY) ACTUATOR USING FORCED CONVECTION (강제 대류를 이용한 형상기억합금 작동기)

  • Jun Hyoung Yoll;Kim Jung-Hoon;Park Eung Sik
    • Journal of computational fluids engineering
    • /
    • v.10 no.2
    • /
    • pp.48-53
    • /
    • 2005
  • This work discusses the numerical analysis, the design and experimental test of the SMA actuator along with its capabilities and limitations. Convective heating and cooling using water actuate the SMA(Shape memory alloy) element of the actuator. The fuel such as propane, having a high energy density, is used as the energy source for the SMA actuator in order to increase power and energy density of the system, and thus in order to obviate the need for electrical power supplies such as batteries. The system is composed of a pump, valves, bellows, a heater(burner), control unit and a displacement amplification device. The experimental test of the SMA actuator system results in 150 MPa stress(force : 1560 N) with $3\%$ strain and 0.5 Hz. actuation frequency. The actuation frequency is compared with the prediction obtained from numerical analysis. For the designed SMA actuator system, the results of numerical analysis were utilized in determining design parameters and operating conditions.

A Study on Impurities Measurement and Physical Properties of Semiconductive Shield at Power Cable (전력케이블에서 반도전 재료층의 불순물 측정 및 물성에 관한 연구)

  • 이경용;양종석;최용성;박대희
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.53 no.9
    • /
    • pp.455-458
    • /
    • 2004
  • In this paper, we investigated impurities content and physical properties showing by changing the content of carbon black that is semiconductive materials for underground power transmission. Specimens were made of sheet form with the three of existing resins and the nine of specimens for measurement. Impurities content of specimens was measured by ICP-AES (Inductively Coupled Plasma Atomic Emission Spectrometer), and density of specimens were measured by density meter And then specific heat (Cp) was measured by DSC (Differential Scanning Calorimetry). A ranges of measurement temperature were from $0^{\circ}[C]$ to $200^{\circ}[C]$, and heating temperature was $4^{\circ}[C/min]$. Impurities content was highly measured according to increasing the content of carbon black from this experimental result, also density was increased according to these properties. Especially impurities content values of the Al and A2 of existing resins were measured more than 4000[ppm]. Specific heat from the DSC results was decreased according to increasing the content of carbon black. Because ionic impurities of carbon black having Fe, Co, Mn, Al and Zn are rapidly passed kinetic energy increasing the number of times breaking during the unit time with the near particles according to increasing vibration of particles by the applied heat energy.