• Title/Summary/Keyword: Heating Unit

Search Result 497, Processing Time 0.031 seconds

Study on Indoor Thermal Comfort of Advanced EMU (차세대전동차의 실내온열환경 연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Park, Sung-Hyuk;Oh, Seh-Chan;Kim, Young-Nam
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1799-1802
    • /
    • 2008
  • More than 7 million people use the Seoul metropolitan subway network daily. This number tends to increase due to the increase of oil price. Indoor air quality of electrical multiple unit (EMU) is strongly affected by outdoor air quality, however, indoor thermal comfort is subjected to heating, ventilating, and air conditioning (HVAC) system of EMU. In general, air temperature, humidity, air velocity, surface temperature, and illumination are key parameters affecting thermal comfort of passenger. It is known that the well-designed HVAC system should improve the thermal comfort of passengers and should increase the energy efficiency of HVAC system also. In this study, we analyzed the thermal comfort of advanced EMU developed by Korea Railroad Research Institute by using the computational fluid dynamics (CFD) in order to find the optimum HVAC system which can improve thermal comfort of passengers with a minimal energy use.

  • PDF

An Experiment on Performance Evaluation of a Vapor Condensation Type Air Washer System for Semiconductor Clean Rooms (반도체 클린룸용 수증기 응축식 에어와셔 시스템의 성능평가)

  • Yeo, Kuk-Hyun;Park, Sang-Tae;Yoo, Kyung-Hoon;Son, Seung-Woo
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.442-447
    • /
    • 2006
  • In semiconductor manufacturing clean rooms, it becomes important to remove airborne molecular contaminants as well as particulate contaminant in outdoor air introduced into clean rooms. One suitable control technique for these chemical contaminants is air washing by water in an outdoor air handling unit. In order to enhance the removal efficiency of chemical contaminants the effect of adding a heating and humidifying process before an air washer was examined.

  • PDF

Multi type heat pump system computer simulation and experimental verification (멀티형 히트펌프 시스템 컴퓨터 시뮬레이션과 실험적 검증)

  • 한도영;정민영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.12-19
    • /
    • 2000
  • The multi type heat pump system may provide more energy savings and better environmental conditions than the single type heat pump system may do. In order to design a multi type heat pump system, it may be recommended to develop the system simulation program, which can predict the characteristics of the system such as unit capacities, power consumptions, and system COP's. In this study, the steady state simulation program of the multi type heat pump system was developed. The results from the simulation program were compared with those from the experimental tests which were performed in the environmental chamber, Cooling tests show 3.11% and 0.94% of error in capacity and COP, and heating tests show 3.30% and 1.90% of error in capacity and COP, respectively. Therefore, the steady state simulation program developed for this study can effectively be used for the design and the performance prediction of the multi type heat pump system.

  • PDF

A Study on the FIDVR Mitigation Scheme using Dynamic Voltage Support by STATCOM (STATCOM을 활용한 FIDVR 완화 방안에 대한 연구)

  • Lee, Yunhwan;Jung, Seungmin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.4
    • /
    • pp.208-213
    • /
    • 2018
  • In this paper, we studied the control strategy of applying STATCOM(static synchronous compensator) to mitigate the FIDVR(fault induced delayed voltage recovery) phenomenon. The proportion of motor loads is gradually increasing which might affect power system stability. Excessive reactive power consumption by the stall of the motor loads causes FIDVR phenomenon. In addition, the low inertia of the small HVAC(heating, ventilation and air conditioner) unit will not separate itself in the event of a contingency, causing system instability. For this reason, we have developed a control strategy that utilizes STATCOM efficiently through static and dynamic analysis. Case studies on a Korean power system have validated the performance of the proposed scheme under severe contingency scenarios. The results have verified that the proposed strategy can effectively mitigate FIDVR and improve the stability and reliability of the system.

A hybrid cutting technology using plasma and end mill for decommissioning of nuclear facilities

  • Choi, Min-Gyu;Lee, Dong-Hyun;Jeong, Sang-Min;Figuera-Michal, Darian;Seo, Jun-Ho
    • Nuclear Engineering and Technology
    • /
    • v.54 no.3
    • /
    • pp.1145-1151
    • /
    • 2022
  • A hybrid cutting using both plasma and end mill was developed for safe and efficient dismantling of nuclear facilities. In this cutting method, a moving arc plasma heats up the workpiece before milling. Thermally softened part of the workpiece is then removed quickly and deeply with an end mill. For the cutting experiments, a three-axis numerical control (NC) milling machine was combined with a commercialized arc plasma torch and used to cut 25 mm thick stainless steel plates. Experimental results revealed that pre-heating by arc plasmas can improve the cutting volume per unit time higher than 40% by reducing the cutting load and increasing the cuttable depth when using an end mill without cutting fluids. These advantages of a hybrid cutting process are expected to contribute to quick and safe segmentations of metal structures with radioactively contaminated inner surfaces.

Recognition and Application on the Curriculum of High School Home Economics by Teachers and Students -Centering on the Unit of Cooking Practice- (고등학교 가정과 교사와 학생의 가정과 교과내용에 관한 인식 및 활용 -조리실습단원을 중심으로-)

  • 주명자;임양순
    • Journal of Korean Home Economics Education Association
    • /
    • v.3 no.1
    • /
    • pp.1-13
    • /
    • 1991
  • The purpose of this study is to find out problems through looking into the actual condition of management and the extent of application in cooking practice in High School Home Economics Education, and as a practical subject, to present some basic materials to contribute to accomplishing the object of High School Home Economics Education through trying to find a direction to enhance educational value. The contents of this study are these : to study with a theoretical background character, object, and contents of Home Economics referring to related books and to investigate the actual condition of management, the extent of application to life of cooking practice unit, and standard of recognition of students and teachers about this subject and to find out rational and efficient method of management. 552 girl students and 72 home economics teachers in cities and counties in Kangwon-do were asked to answer the answer-sheet prepared. The result of this study is summerized as follows. 1. Most of the respondent regard the characters and objects of Home Economics as a matter of basic education, education for life, and education for the wholeman, but they neglect the aspect of education for a course of this subject. 2. Among the contents of Home Economics, students are much interested in the Unit of preparing table, especially in cooking. Most of the teachers teach the cooking unit with only explanation without practice because of the lack of material and human resources. 3. Students have desire to do cooking practice, but the extent of application of their real life appears to be low. 4. It appears to be necessary that boy students as well as girl students should learn Home Economics as an education for preparation for managing housework. 5. Home Economics teachers are mostly satisfied with their teaching profession. But teachers who have been teaching for 3 or 5 years appear not to be satisfied with it. 6. Although Home Economics teachers can teach Cooking practice Unit with confidence, they usually do it with theory rater than with practice, and they evaluate it after practicing, but most of them do not add the result to the student’s grade. 7. They use most of the cookers fixed on the standard list of High School Cooking Practice appliances, but they seldom use electric heating cookers.

  • PDF

Thermal Performance Analysis of Hybrid heat Supply System for Zero Carbon Green Home (제로카본 그린홈 구현을 위한 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.53-59
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000kcal/hr, a $0.15m^3$ hot water storage tank for space heating, a evacuated tubular solar collector $3.74m^2$ of aperture area at the $20^{\circ}$ install angle, a $0.3m^3$ hot water storage tank. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

Mineralogical Characterization and Thermal Behaviours of Kaolins from the Southern Parts of Korea (한반도 남부지역에서 산출되는 카올린광물의 고온영역에서의 광물학적 특성 연구)

  • Lee, Su-Jeong;Moon, Hi-Soo
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.269-279
    • /
    • 1996
  • Dehydroxylation and mullitization of primary and secondary kaolins were investigated in order to compare and understand the differences in thermal behaviours by DTA and TG up to $1,100^{\circ}C$. Chemical analyses and EPMA of the samples revealed nearly ideal unit-cell formulae of kaolins. The weight losses of dickite and halloysite are 14% and 12.5% on the average, respectively. The activation energies of dehydroxylation of kaolin minerals were calculated according to Kissinger's approach which uses various heating rates in DTA to estimate the activation energy of thermal reactions. The activation energies of dehydroxylation of halloysites from Daemoung and Buksam mines are about $163kJmor^{-1}$ (white), $168kJmor^{-1}$ (pink), and $176kJmor^{-1}$ respectively. The activation energies of dickites collected from Sungsan and Ogmae mines are about $166kJmor^{-1}$ and $387kJmor^{-1}$. The asymmetric shape of endothermic peak in DTA, the relative intensities of OH-stretching bands in FTIR spectroscopy and the existence of residual XRD peaks of the samples which were heated at $550^{\circ}C$ for 2 hours indicate that Sungsan dickite may be more disordered than Ogmae dickite. The new phase formed in thermally treated samples in the range of $900^{\circ}C$ to $1,100^{\circ}C$ was identified as mullite by XRD on the basis of disappearing of the characteristic peaks of kaolins and increasing of amorphous background upon heat treatment. On further heating, loss of more water from dehydroxylate resulted in the formation of mullite and the characteristic X-ray diffraction patterns of mullite began to appear at about $900{\sim}1,000^{\circ}C$ in kaolins.

  • PDF

A Study on the Brewing in "The Hong's Zu Bang Moon" ("홍씨주방문"의 양조에 관한 분석적 고찰)

  • 손정렬;김성미;이성우
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.1 no.1
    • /
    • pp.17-29
    • /
    • 1991
  • The Hong's-Zu-Bang-Moon, although it is not know when and by whom it was written, is estimated to have written in the middle of 1800, but has not been published yet. In general, other cooking books in Yi's Dynasty were on the cooking methods of a variety of foods. But the book deals solely with brewing, which is the trait of it. The book comprises a total of 36 items, among which So-Gog-Ju wine was excluded because only a part of it was recorded. Another item deleted, written vaguely and difficult to understand was, on a closer analysis of its content, 'Song-Soon-Ju wine'. According to the analysis of this book, the cereals used for brewing were 59 percent of regular rice and 41 percent of sticky rice including other 12 kinds of special materials. As for the processes, the precesses using Jee-Ae-Bop was dominant. The processing technique whose special words and expressions were analyzed in this study, were divided into 18 preparation methods, 45 processing ones, and 7 heating ones. The temperature processing whose expressions were analyzed here were divided into 6 cooking processes, 7 medium ones and 3 heating ones. The measurement unit of 'Doe' was most often used. It tried to show relatively accurate measurements but showed just approximate ones. There were 19 kinds of brewing utensis. Urns were most often used, but it was impossible to discern and kind. As for the tast of the wines, the writer showed his subjective expressions. The margianal point in this study is that it was very difficult to interpret the book. The closing up of twings of on azaled over the urn had no scientific base but said something of korean folkways at that times.

  • PDF

Pre-Analysis Study on Ground Source Heat Pump System in Building with RETScreen (RETScreen을 활용한 건물에서의 지열 히트펌프 시스템 적용 사전 분석연구)

  • Kim, Yu Jin;Lee, Kwang-Seob;Lee, Euy-Joon;Kang, Eun-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.40 no.2
    • /
    • pp.1-10
    • /
    • 2020
  • Korea government published renewable energy obligation policy that public building must be supplied some part of total consumption energy (2019: 27%, 2020: 30%). RETScreen is freely available global energy tool that developed by Canadian National Energy Laboratory to quantify energy saving to compare conventional system. This program can be performed energy modeling, cost analysis, greenhouse gas emission analysis and financial analysis. In this study, GSHP (Ground source heat pump) heating and cooling system were studied for the energy deliverly and ROI (Return On Investment) in an office building. Three cases were studied according to the number of HP (Heat pump) units for the 1,000㎡ office building located in Daejeon. Results indicated that the energy delivery of the case 1 (1 HP unit) covered 57% of the office building heating and cooling energy consumption. The case 2 (2 HP units) covered 87.8% and the case 3 (3 HP units) covered 96.8% of the office building energy consumption. The ROI of the case 1 indicated 7.9 years. While 8.2 years for the case 2 and 9.7 years for the case 3.