• 제목/요약/키워드: Heating Unit

검색결과 498건 처리시간 0.027초

전력선 통신(PLC)을 이용한 난방기기 제어 및 원격제어 시스템의 개발에 관한 연구 (A Study on the development of Heating Facility Control and Remote Control System using Power Line Communication (PLC))

  • 김용태;신관우;이윤섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 합동 추계학술대회 논문집 정보 및 제어부문
    • /
    • pp.65-67
    • /
    • 2001
  • PLC (Power Line Communication) is the communication method using the existing power line installed in houses and offices to convert and transmit high frequency communication signal from tens of KHz to tens of MHz, and receive the filtered signal using high frequency filter. The advantage of PLC is that PLC uses the existing power line installed in houses and offices so it does not require separate power line. Easy and convenient access using electric outlets is another advantage of PLC. However, PLC has some disadvantages such as limited transmission power, high load interference and noise, variable signal attenuation, characteristic of impedance selective possibility of frequency property. This study designed the boiler temperature control system by unit using the modem designed on the basis of technology used for PLC modem, and designed remote control system using internet. After conducting experiments with those two systems, it was possible to control stably. By commercializing this product, we can avoid unnecessary heating of separate temperature control unit, and save the cost according1y, and it is possible to control on a remote site using internet in a more convenient way.

  • PDF

최근 3년간 수입 유연탄 분석 및 연소열성능 해석을 활용한 석탄화력 발전소 탄종 경제성 평가 연구 (Economic Evaluation of Coals Imported in Last 3 Years for Power Plant Based on Thermal Performance Analysis)

  • 백세현;박호영;고성호
    • 한국연소학회지
    • /
    • 제18권3호
    • /
    • pp.44-53
    • /
    • 2013
  • In this study, the economic evaluation for imported coals was conducted for power plant based on thermo-dynamical performance analysis. The number of coal types considered was 1,755 imported by five power generation companies in Korea during the 2010-2012. The higher heating value (HHV) of the coals ranged 4,000-6,500 kcal/kg, mostly sub-bituminous. The 1D thermo-dynamical performance modeling was performed for a 500 MWe standard power plant using PROATES code. It was founded that the low rank coals had negative effects on the plant efficiency mainly due to the increased heat loss by moisture, hydrogen and flue gas. Based on the performance analysis, the economic performance of the coals was evaluated. The apparent price of low-rank coals tended to be significantly lower than design coal; for example, the unit price of coal with a HHV of 4,000 kcal/kg was 57% of the reference coal having 6,080 kcal/kg. Considering the negative effects leading to a decrease in the thermal performance, heating value compensation, and increased parasite load, the corrected unit cost for the coal with 4,000 kcal/kg was 90.7% of the reference coal. Overall, the cost saving by imported coals was not high as expected.

Alternative Strategies to Central Heating Ventilation and Air Conditioning

  • Shrestha, Pramen P.;Prgada, Mythili
    • 국제학술발표논문집
    • /
    • The 9th International Conference on Construction Engineering and Project Management
    • /
    • pp.401-407
    • /
    • 2022
  • Central heating, ventilation and air conditioning (HVAC) is one of the largest consumers of energy in the residential sector. This project explores the use of multiple HVAC units and/or Zoning in a single residence to reduce energy loads. The energy consumption data of a detached single-family home using two HVAC units, one primary for the main house and a secondary HVAC for a casita, was collected for the same month for two consecutive years, along with details related to the outdoor temperature and the square footage being air-conditioned by each HVAC. A regression algorithm was trained using the above details to find the relation between the parameters. Next, based on the occupancy and usage patterns, the HVAC was redesigned assuming more area under the secondary HVAC unit. The trained algorithm was then used to make energy usage predictions for the revised primary HVAC area, with the assumption that the secondary HVAC unit was turned off. The results were compared with existing energy usage data. It was determined that there were significant energy savings in the second scenario. It is expected that this study and its findings will help future research projects explore more ideas as alternatives to central HVAC, in improving the economic viability of existing options, and in developing a savings calculation tool that will help consumers make informed decisions on their best alternatives to central HVAC.

  • PDF

건물의 개구부 크기에 따른 외벽 수열온도분포에 관한 연구 (A Study on the External Wall Heating Temperature Distribution According to Opening Size in Building)

  • 정의인;홍상훈;김봉주
    • 한국건축시공학회지
    • /
    • 제20권3호
    • /
    • pp.261-267
    • /
    • 2020
  • 본 연구는 공동주택의 화재 및 화재확산에 의한 피해의 예방과 대응마련을 위해 실내화재 조건에 대한 정확한 데이터 확보를 목적으로 실물화재실험을 재현하였다. 실험조건으로 개구부 크기를 다르게 하여 외벽 수열온도를 측정 및 분석하였으며, 다음과 같은 결과를 도출하였다. 개구부 크기를 2,000mm, 1,600mm, 1,400mm로 실험하였을 때, 플래시오버는 각각 630초, 505초, 510초에서 일어났으며, 총 가열시간은 개구부 크기에 따라 815초, 713초, 721초로 나타났다. 개구부 크기에 의한 외벽 최고 수열온도는 2,000mm에서 282.4℃, 1,600mm에서 382.9℃, 1,400mm에서 423.8℃로 나타나 개구부의 크기가 작아질수록 화재확산에 의한 외벽의 수열온도는 높아지는 것으로 나타났다.

콤팩트형 태양열/지열히트펌프 하이브리드 냉난방 및 급탕 시스템 개발 및 성능분석 (The Development and Performance Analysis of Compact Type Solar Thermal/Ground Coupled Heat Pump Hybrid System for Heating, Cooling and Hot water)

  • 백남춘;정선영;윤응상;이경호
    • 한국태양에너지학회 논문집
    • /
    • 제32권5호
    • /
    • pp.59-67
    • /
    • 2012
  • In this study,the compact type solar thermal and ground coupled heat pump hybrid system for space heating/cooling and hot water supply has been developed. This hybrid system was installed in Zero Energy Solar House(ZeSH) in KIER for the demonstration. The thermal performance and operational characteristics of this hybrid system were analysed especially. The results are as follows. (1) This hybrid system was designed in order to address the existing disadvantages of solar thermal/ground coupled heat pump system. For this design, all parts except solar collector and ground coupled heat pump were integrated into a single product in a factory. The compact type unit includes two buffer tanks, an expansion tank, pumps, valves, a controller, etc. This system has an advantage of easy installation with simple plumbing work even in narrow space. (2) The thermal charging and discharging time of the buffer tanks and its characteristics by ground coupled heat pump, and heat pump COP according to geo-source temperature and buffer storage temperature have been studied. This system was found to meet well to the heat load without any other auxiliary heating equipment. (3) The operating hours of the ground coupled heat pump as a backup device of solar thermal can be reduced significantly by using solar heat. It was also found that the minimum heating water supply setting temperature and maximum cooling water supply setting temperature make an influence on the heat pump COP. The lower heating water and the higher cooling water temperature, the higher COP. In this respect, the hybrid system's performance can be improved in ZeSH than conventional house.

터널 라이닝 표면에 부착된 발열체로 인한 내부 온도 변화의 실험적 연구 (Experimental Study on Internal Temperature Change Induced by Heating Element Attached to Tunnel Lining Surface)

  • 진현우;황영철
    • 한국지반환경공학회 논문집
    • /
    • 제18권11호
    • /
    • pp.35-40
    • /
    • 2017
  • 한랭지역에 건설된 터널은 낮은 기온으로 인하여 콘크리트 라이닝 배면의 동결이 발생하게 되며, 콘크리트 라이닝의 손상을 발생시켜 터널구조물의 내구성을 감소시킨다. 터널 라이닝 배면 지반의 동결을 억제시키기 위하여 터널 라이닝 표면에 발열체를 부착하고 일정시간 동안 발열시켜 콘크리트 라이닝 내부의 온도변화를 측정하였다. 냉동챔버를 제작하여 현장현황을 모사하고 발열체는 탄소나노튜브(CNT, Carbon Nano Tube) 재료를 플레이트로 제작하여 표면에 부착하고 전기공급을 통해 발열시켰다. 발열체를 발열시킴에 따라 콘크리트 라이닝의 내부 위치별 온도변화 분포를 측정하였으며, 외기온도 및 발열온도의 유지시간에 따른 영향을 분석하였다.

지하역사 공기조화기용 축류형 사이클론 클러스터의 수치해석적 성능 평가 연구 (Numerical Study of Axial-flow Cyclone Cluster for Subway Station HVAC system)

  • 김명준;김호중;김진관;권순박;김태성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.757-761
    • /
    • 2009
  • Axial-flow cyclone separator cluster can be used for a dust removal device inside a heating, ventilation, and air conditioning(HVAC) system of subway station. In this study, 3-dimensional computational fluid dynamics(CFD) analysis was performed to compare single unit axial-flow cyclone with couple unit axial-flow cyclone cluster. It is shown that the performance of cyclone separator is not influenced by number of single units but influenced by ability of single unit.

  • PDF

9.9MW급 바이오매스 열병합발전 타당성 연구 (The Feasibility Analysis of 9.9 MW Biomass Cogeneration System)

  • 최재영;설용건
    • 신재생에너지
    • /
    • 제10권2호
    • /
    • pp.40-47
    • /
    • 2014
  • This study is intended to analyze the appropriate scope for 9.9MW biomass cogeneration, feasibility and sensitivity according to changing market situation. In the study, the heat load is classified into three types to predict heat sales and find out the appropriate scope of thermal business that is operated in CHP 34.42 Gcal/h, PLBwg 70 Gcal/h of cogeneration. the feasibility is estimated based on internal rate of return (IRR) and net present value(NPV). the sensitivity is analyzed in terms of biomass fuel cost, unit price of heating cost, investment cost, SMP unit price and REC unit price.

열소자 온열요법시 VX-2 hepatoma내의 온도 변화에 대한 연구 (Temperature distribution in VX-2 hepatoma heated with thermoseed hyperthermia)

  • 최일봉;박용휘
    • Radiation Oncology Journal
    • /
    • 제12권3호
    • /
    • pp.295-300
    • /
    • 1994
  • It was the purpose of present study to develop a new thermoseed for heating deep-seated tumors and assessment of the effect of magnetic control on thermoseeds. Aqueous suspension of iron micro spheres (Ferropolysaccharide) was injected directly into the VX-2 hepatoma and heated with 1.2 MHz inductive radiofrequency unit. Aqueous thermoseed suspension was delivered to the tumor by simple percutaneous injection. The limitation of the thermoseed heating method is the positional change of thermoseed particles in the tumor after implantation. The thermoseed particles could enter the systemic blood circulation and cause a severe embolization of a critical organ. To minimize this limitation, we have used the magnetic control after loading the thermoseed in the tumor, W hen ferropolysaccharides were exposed to a strong magnetic field, they magnetized and subsequently exerted a magnetic force on each other, forming larger aggregates of particles. The size of aggregated Particles were too big to enter the systemic blood circulation. Thus, unlike other thermoseed method, we hold the thermoseed particles stationary in the tumor. The temperature of the injected site and immediate vicinity elevated by $4-5^{\circ}C$. The temperature of the surrounding normal hepatic tissue elevated by $1-2^{circ}C$ only. The heating effect within the tumor was variable depending on the density of ferromagnetic aqueous suspension. Our results suggest that inductive heating of tumor injected with ferropolysaccharide solution offers the possibility of effective heat delivery to the defined tumor volume, which is difficult to heat with other heating devices.

  • PDF

9% Nickel강이 적용된 Type-B LNG 연료탱크 선상가열의 물성 변화에 관한 연구 (A Study on the Variation of Physical Properties of Line-heated for Type-B LNG Fuel Tank with 9% Nickel Steel Plate)

  • 최경신;이지한;홍지웅;정원지
    • 한국기계가공학회지
    • /
    • 제19권7호
    • /
    • pp.89-97
    • /
    • 2020
  • Container vessels continue to grow in size, led by global shipowner. Large ships can be loaded more cargo at a time, reducing the cost of transportation per teu. this eventually leads to economies of sale, in which the production cost per unit decreases with increasing output. in accordance with the 70th Convention of the Marine Environment Protection Committee of the International Maritime Organization, as of January 1, 2020, MARPOL Annex VI Regulation 14.1.3 will be effective. All vessels must be meet these criteria to reduce Sox emissions and reduce NOx emissions by reducing the content of manned sulfur oxides from 3.5% to less than 0.5%, otherwise IACS Member States Entry to the port is denied. in order to do that need to LNG storage tank. in this study characteristic of the material after line heating (600℃,700℃,800℃,900℃) of 9% Ni steel used in the manufacture of LNG fuel tank of ship were verified using by mechanical test. In the heating method by line heating. The initial properties of steel are changed by variables such as temperature, time, speed. The experimental data of line heating presented in this paper confirmed that the initial change of 9% Ni steel could be minimized.