• 제목/요약/키워드: Heating Panel

검색결과 185건 처리시간 0.025초

태양에너지를 이용한 열-전기 동시생산을 위한 PV-Solarwall 단위모듈 성능평가 연구 (The Performance Evaluation Study of PV-Solarwall Unit Module Solar Thermal-Electric Energy)

  • 김용환;조일식;이의준;현명택;강은철
    • 한국태양에너지학회 논문집
    • /
    • 제25권3호
    • /
    • pp.69-75
    • /
    • 2005
  • The PV-Solarwall system has been introduced as a promising alternative to harness solar energy for both heating applications and electricity generation simultaneously. The system comprises a PV solar panel(for electricity generation). In addition, the solarwall incorporates a fan strategically located behind the PV panel to bring the warm and fresh air from the solarwall into the room. Because of its location and convective cooling principle, the fan also serves to reduce the operating temperature of the PV panel thereby increasing its efficiency. So this PV-Solarwall system holds much promise for saving heating and electricity costs compared with a PV system without solarwall. In particular, by controlling the tilt angle of the entire PV-Solarwall system between $0^{\circ}$(horizontal) and $90^{\circ}$(vertical), the performance of the system can be further evaluated. It is expected that the range of tilt angle PV-Solarwall between $40^{\circ}$ and $50^{\circ}$ will improve the output of the system.

PDP용 배기로내 열전달 현상에 관한 해석 (The Analysis of the Heat Transfer Characteristic in a PDP Ventilation Chamber)

  • 박형규;정재동;김찬중;이준식;박희재;조영만;조해균;박득일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.385-391
    • /
    • 2000
  • An analysis of the heat transfer in a PDP ventilation chamber has been conducted to investigate the required heat curve and temperature uniformity of the panels. Firstly, experiment in a test chamber has been carried out and compared with the unsteady 3D numerical simulation. Reasonable agreement was found, which suggested that the employed numerical model had its credibility in an actual PDP ventilation process. On this ground, tact-type heating/cooling system was analyzed. The panel temperature was more uniform in the $40^{\circ}C$ tact-type system than in the $80^{\circ}C$ one. Comparison of full simulation of a cart and simplified simulation of one panel shows the panel pitch, which is closely related to a production rate, can be also predicted.

  • PDF

PSC 풍도슬래브에 부착된 내화패널의 내화특성에 관한 실험연구 (Experimental Study on the Fire Proofing Characteristic of Fire Resistance Panel that it attaches to PSC Airpit-Slab)

  • 이두성;배정;최헌;민인기
    • 대한토목학회논문집
    • /
    • 제33권2호
    • /
    • pp.465-473
    • /
    • 2013
  • 본 연구에서는 터널에서 발생되는 화재로부터 구조물을 보호하기 위해 내화패널이 부착된 프리캐스트 PSC 슬래브의 내화성능을 조사하기 위해 내화실험이 수행되었다. 내화실험은 독일의 RABT(Richtlinien fur die Ausstatung und den Betrieb von stra${\beta}$entunneln) 화재시간-온도곡선을 적용하여 내화성능을 평가하는 것으로 하였다. ITA(2004)에서 제시하는 기준에 따라 내화성능 시험을 수행한 결과, 콘크리트의 손상을 판단하는 위치인 t=0mm의 최대온도는 $367^{\circ}C$로서 손상한계온도 $380^{\circ}C$(ITA 2004)이하였으며, 철근의 손상을 판단하는 위치인 t=25mm의 최대온도는 $239^{\circ}C$로서 손상 한계온도인 $250^{\circ}C$이하로 나타났다. 실험결과로부터, 25mm두께의 내화패널이 부착된 프리스트레스 슬래브 시험체는 내화성능을 가진 것으로 입증되었다.

강화폴리에스테르튜브(XL 튜브)에 진동형 히트 파이프를 결합한 고성능 난방 패널의 성능에 관한 연구 (A Study on the highly efficient ondol system combined the strengthen polyethylene pipe with pulsating heat pipe)

  • 김창희;김종수;우재호;공상운
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.578-583
    • /
    • 2008
  • Korea which has change of clear season is using unique heater by the name of On-dol being invented since ancient times. Floor-heating device has no radiator, and generates no noise and dust. It can obtain satisfied heating sense than other heating system in low room temperature. And also it is a pleasant system that equals bottom and top temperature in a room. The purpose of this study is to develop the Floor-heating device using pulsating heat pipe. It propose floor-heating device using pulsating heat pipe of the dry process which alternative polyethylene pipe(low XL pipe) that is used widely to existent floor heating system and produce pilot Experiment and analyzed operation condition and performance of most suitable. In this study, main purpose is to develop floor-heating system using pulsating heat pipe by finding an optimum working condition according to changing ratio and evaluating a performance.

  • PDF

플라즈마 디스플레이 패널의 MgO막 부식 특성에 관한 연구 (The Study of erosion characteristics for MgO layer in plasma display panel)

  • 신재화;정동효
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.72-74
    • /
    • 2002
  • In this paper, we showed the erosion characteristics of MgO protector layer releated to lifetime of plasma display panel(PDP). We observed MgO erosion characteristic as a functions of deposition conditions. In RIE condition of Xe gas, the lowest erosion rate appears in the conditions of no heating, bias voltage -30V and pressure 5mtorr. In general. as deposition rate increases, erosion rate decreases.

  • PDF

반사판을 이용한 고정식 집광형 복합 Panel에 대한 연구 (A study on the fixed-concentrating hybrid panel using reflector)

  • 김완태;김규조;김승환;허창수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.352-355
    • /
    • 2000
  • Although for its great amount and cleanness solar energy has been studied a lot as a substitute one, it is limitedly being utilized in heating water and partly in special usage for high cost of installing solar cell in Korea. Consider domestic shortage of natural energy resources and environmental issue by the Climate Agreement treated in 1994, it is urgently needed to study the practical application of solar energy as a substitute one. Therefore in order to increase the efficiency of solar cell and decrease its price, this study treats the course of designing and manufacturing the panel that connects sunlight by fixing reflector.

  • PDF

샌드위치 패널의 열적 손상에 의한 부식 형상에 관한 연구 (A study on the shapes of thermal corrosion in sandwich panel)

  • 김현동
    • 한국화재조사학회지
    • /
    • 제3권1호
    • /
    • pp.43-46
    • /
    • 2003
  • In this experimental report, We introduce an idea of thermal corrosion in sandwich panel. In brief, Because the structures of sandwich panel are easily collapsed by thermal damage caused by a fire, it is very difficult to investigate a point and origin of fire. Therefore, If the shapes of thermal corrosion are reconstructed according to change of temperature and lapse time by experiment in sandwich panel, it is very simple task that fire scene investigators search for a point and origin of fire. As a result, we present the difference of thermal corrosion between samples which are applied heat by many-sided variable, such as temperature, heating time, lapse time, humidity, and others.

  • PDF

T-103 훈련기의 환기와 난방 시스템 개선에 관한 연구 (A Design and Application of the Ventilating and Heating System of T-103 Trainer Aircraft for Improvement)

  • 정대한
    • 한국군사과학기술학회지
    • /
    • 제16권3호
    • /
    • pp.277-284
    • /
    • 2013
  • In this paper, the ventilating and heating system of T-103 trainer aircraft were investigated and redesigned to improve its poor performance. The ventilation system of the trainer was designed to increase the mass flow rate of fresh air by using air intake valves. The flow-in air through the air intake valve is supplied to the cabin by the ram effect of aircraft and the propeller. And the additional heating system was installed to improve the temperature of the cabin inside. The wasted heat from the exhaust gas of the engines was used as heat source of the additional heating system by installing an heat exchanger around the exhaust nozzle. The additional fresh air and the heated air enter the cabin via two ducts mounted under the instrument panel and behind the pedal in the cabin. The additional ventilating and heating system can be controlled by the first pilot and the secondary pilot individually using the control knob equipped separately. After mounting the additional ventilating and heating system, evaluations such as inspection of parts and component, ground run-up test, in-flight test, user test, etc. were conducted. The result of the tests was sufficient to meet the requirements of the manuals, and the pilots were satisfied with the additionally mounted systems.

LCD with Tunable Viewing Angle by Thermal Modulation of Optical Layer

  • Gwag, Jin-Seog;Lee, You-Jin;Han, In-Young;Yu, Chang-Jae;Kim, Jae-Hoon
    • Journal of Information Display
    • /
    • 제10권1호
    • /
    • pp.19-23
    • /
    • 2009
  • In this paper, we review the proposed liquid crystal display (LCD) with a tunable viewing angle consisting of a conventional liquid crystal display (LCD) panel and a thermally variable retardation layer (TVRL) characterized by uniformly aligned LC film with transparent indium-tin-oxide electrodes for Joule heating. In the TVRL, nematic phase is transitioned into isotropic by Joule heating. The numerical calculation showed that the intrinsic wide viewing angle was achieved at the isotropic phase of the TVRL by Joule heating, whereas the narrow viewing angle was obtained at the nematic phase of the TVRL. The simulated and experimental results of the proposed LCD show continuous and symmetrical viewing angle characteristics by tuning the retardation of TVRL using Joule heating. The structure of the viewing angle control proposed here is adoptable to all LCD modes with wide viewing angle characteristics.

시설포도 농가의 가온시기 변화에 미치는 요인 분석 (Analysis of Factors for Heating Period Changes among Greenhouse Grape Farms)

  • 최돈우;임청룡
    • 한국산학기술학회논문지
    • /
    • 제18권10호
    • /
    • pp.209-214
    • /
    • 2017
  • 본 연구에서는 한 칠 FTA 이후 시설포도 재배농가들이 가온시기를 늦추는 요인을 알아보기 위해 2004년부터 2016년까지 작형 변화 패널 데이터를 이용하여 분석하였다. 패널로지스틱모형에 대한 분석결과 시설포도 재배면적에 대한 추정계수는 0.0002로 10% 유의수준에서 통계적으로 유의한 것으로 나타났고, 포도 수입량에 대한 추정계수는 1.4258로 1% 유의수준에서 통계적으로 유의한 것으로 나타났으며, 지역더미에 대한 추정계수는 0.808로 5% 유의수준에서 통계적으로 유의한 것으로 나타났다. 이것은 재배면적이 많은 농가일수록, 포도 수입량이 증가할수록, 상대적으로 추운 중북부지역일수록 가온시기를 뒤로 미루게 될 확률이 증가하는 것으로 나타났다. 정부에서는 포도의 수입량 증가로 인한 시설포도농가의 피해를 줄이기 위해 FTA 피해보전직접지불 폐업지원을 하고 있어 시설포도농가의 피해를 다소나마 줄일 수 있지만, 이것은 궁극적인 대책이 되지는 않을 것이다. 포도 소비변화에 적절하게 대응하기 위해서는 품종 갱신, 가온비용 절감을 위한 농자재 지원, 비닐하우스 시설현대화를 통한 에너지 효율 증대 및 비용 절감 등의 다양한 지원책이 필요할 것이다.