• 제목/요약/키워드: Heating Device

검색결과 478건 처리시간 0.026초

기폭용 퓨즈의 RF 감도 특성 (A Characteristics of RF Sensitivity for a Firing Fuse)

  • 간종만;권준혁
    • 한국전자파학회논문지
    • /
    • 제15권6호
    • /
    • pp.573-578
    • /
    • 2004
  • 전기 기폭장치(EED, electroexplosive device)는 브리지 와이어, 추진제, 리드 핀 및 금속관으로 구성되었고, 기폭신호가 인가되면 브리지와이어의 발열에 의해 추진제를 점화시킨다. 또한 고출력 통신기나 레이더에서 방사되는 전자파에 의해 EED는 예기치 않은 기폭이 발생할 수 있어, EED에 대한 EMC 설계 및 시험관련 군사규격서를 제정하여 적용하고 있다. 본 논문은 항공기에 대한 전기체 EMC 시험평가를 수행할 때, 항공기에 설치 된 EED 대신에 사용할 기폭용 퓨즈의 RF 감도 특성을 기술하였다 RF 기폭수준은 전송선로 이론을 활용하여 예측하였고, 군사규격서에 규정된 DC 감도와 RE 감도를 측정하였다.

Investigation of Cooling Effect of Flow Velocity and Cooler Location in Thermal Nanoimprint Lithography

  • Lee, Woo-Young;Lee, Ki Yeon;Kim, Kug Weon
    • 반도체디스플레이기술학회지
    • /
    • 제11권4호
    • /
    • pp.37-42
    • /
    • 2012
  • Nanoimprint lithography (NIL) has attracted broad interest as a low cost method to define nanometer scale patterns in recent years. A major disadvantage of thermal NIL is the thermal cycle, that is, heating over glass transition temperature and then cooling below it, which requires a significant amount of processing time and limits the throughput. One of the methods to overcome this disadvantage is to improve the cooling performance in NIL process. In this paper, the performance of the cooling system of thermal NIL is numerically investigated by SolidWorks Flow Simulation program. The calculated temperatures of nanoimprint device were verified by the measurements. By using the analysis model, the effects of the change of flow velocity and cooler location on the cooling performance are investigated. For the 6 cases (0.1 m/s, 0.5 m/s, 1 m/s, 3 m/s, 5 m/s, 10 m/s) of flow velocity and for the 6 cases of distances (50 mm, 40 mm, 30 mm, 20 mm, 10 mm, 1 mm) of cooler location, the heat conjugated flow analyses are performed and discussed.

공조공간에서 수평토출형 에어커튼의 차단 성능 (Isolation Performance of the Single-Sided air Curtain in Air-Conditioned Space)

  • 성순경
    • 설비공학논문집
    • /
    • 제24권11호
    • /
    • pp.806-812
    • /
    • 2012
  • Air curtains are widely used in commercial and public buildings to replace solid doors where traffic of people is predicted. At doorways where the solid door is open continuously or intermittently, an air curtain may be installed in order to reduce the flow of heat and moisture from the enclosed space to the outside. The purpose of this paper is to predict isolation performance of the single-sided air curtain when the wind is blowing. For the study, a numerical simulation is used to find the influence of various jet velocities on the efficiency of the single-sided air curtain device which is mounted at the side of the doorway. The isolation performance of the single-sided air curtain is evaluated by sealing efficiency which provides the assessment of the infiltration air ratio. According to the result of this study, the single-sided air curtain has lower sealing efficiency than downward-blowing air curtain. Therefore, for energy conservation in heating space, the single-sided air curtain is not recommended because of its low effectiveness.

밀폐형 지중열교환기 설계를 위한 지중 유효열전도도 데이터베이스 구축 (Construction of Ground Effective Thermal Conductivity Database for Design of Closed-Loop Ground Heat Exchangers)

  • 최재호;손병후;임효재
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.776-781
    • /
    • 2008
  • A ground heat exchanger in a GSHP system is an important unit that determines the thermal performance of a system and its initial cost. The Size and performance of this heat exchanger is highly dependent on the thermal properties. A proper design requires certain site-specific parameters, most importantly the ground effective thermal conductivity, the borehole thermal resistance and the undisturbed ground temperature. This paper is part of a research project aiming at constructing a database of these site-specific properties, especially ground effective thermal conductivity. The objective was to develop and evaluation method, and to provide this knowledge to design engineers. To achieve these goals, thermal response tests were conducted using a testing device at nearly 150 locations in Korea. The in-situ thermal response is the temperature development over time when a known heating load imposed, e.g. by circulating a heat carrier fluid through the test exchangers. The line-source model was then applied to the response test data because of its simplicity. From the data analysis, the range of ground effective thermal conductivity at various sites is $1.5{\sim}4.0\;W$/mK. The results also show that the ground effective thermal conductivity varies with grouting materials as well as regional geological conditions and groundwater flow.

  • PDF

경피흡수제형의 in vitro 약물방출실험을 위한 연속확산 장치의 개발 (Development of Automated Diffusion Cell for Determining In Vitro Drug Release from Transdermal Device)

  • 변영로;최영권;정서영;김영하
    • 약학회지
    • /
    • 제34권3호
    • /
    • pp.161-165
    • /
    • 1990
  • An automated, simple, and reliable method was developed for determining in vitro drug release rate from transdermal delivery dosage forms. The patch is held in position in the heating block by sandwiching it between the middle plate and the bottom plate of diffusion cell. The dissolution profile of the commercially available transdermal scopolamine patch was determined over a 72-h period, and the results were compared with those obtained with other methods; paddle-over-disk method, reciprocating method, and diffusion cell method. It was demonstrated that the flow-through method is equivalent in terms of release rate profile and accumulated released drug amount over the lifetime of the dosage form tested. Also this method is simple, reliable and reproducible. Therefore, this technique can be used in a quality control for assuring product uniformity.

  • PDF

국내 에너지제로하우스 비교를 통한 요소기술 특성 및 표준 모델 제시에 관한 연구 (Suggestion of the Characteristics of Element Technology and the Standard Model through the Comparison of Domestic Zero-energy Houses)

  • 이충국;이정철;김상수;서승직
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권2호
    • /
    • pp.27-35
    • /
    • 2012
  • Five zero energy house models developed in Korea for the purpose of the energy performance were compared and analyzed in the study. The standard passive house model applying common technology and efficient energy performance elements was proposed. Standard passive house 5 models have been developed commonly aiming at 100% energy saving, applying high-performance and high-efficiency exterior thermal insulation, using 3 low-e coated window system, and targeting average 0.65 ACH to enhance privacy. Energy recovery ventilators and dry and cold radiant heating floor has been partially applied. Eco-design techniques such as the awning device, heat insulating door, using natural light have been used. Solar and geothermal systems as the application of renewable energy technologies have been commonly applied. And fuel cells were applied to a partial model. The standard model based on common technical elements and average performance of each element and obtained from five model analysis has been proposed in the study.

Carbon fiber 후막형 열전센서 소자를 이용한 적외선 체열진단 (The Method of Thermograph using Thermoelectric Sensor Device in the Carbon fiber Thick Films)

  • 송민종;김명훈;유성미;이호식;이원재;박춘배;최운식;김태완
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1-2
    • /
    • 2008
  • Thick films of Carbon fiber were prepared by a heating element of plan shape made in Darin co.. We have investigated surface morphology of the specimen depending on second heat-treatment temperatures. X-ray diffraction patterns of Carbon fiber thick films show that the specimen heat treated below $600^{\circ}C$ was an amorphous phase and the one heat treated above $1100^{\circ}C$ forms a poly-crystallization. Scanning electron microscope(SEM) image of Carbon fiber thick films of the specimen heat treated in between 900 and $1100^{\circ}C$ shows a grain growth. At $1100^{\circ}C$, the specimen stops grain-growing and becomes a poly-crystallization.

  • PDF

최초로 헤테로 원자를 포함하는 폴리(9,9-스파이로 바이플루오렌) 유도체의 합성과 그들의 광학적, 유기전계발광특성 (First Examples of Poly(9,9-spiro bifluorene) Derivatives Containing Heterotoms : Syntheses, Optical, and Electroluminescent Properties)

  • 김명종;이지훈;박종욱
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 하계학술대회 논문집 Vol.9
    • /
    • pp.465-465
    • /
    • 2008
  • Conjugated polymers have attracted much scientific and technological research interest during the past few decades because of their potential use such as polymer light-emitting diodes (PLEDs).1,2 Particularly, lots of phenylene-based polymers such as polyfluorene and its derivatives have been synthesized because of their high photoluminescence quantum efficiencies and thermal stabilities. However, troublesome long wavelength emission in polymer film of polyfluorenes on heating during device formation or operation has been the crucial problem for practical applications. The source of the long wavelength emission was initially believed to be solely due to excimer emission as a result of polymer aggregation. It has also recently been correlated with emissions from ketonic defects in the fluorene units. Many efforts have been made to reduce the tendency to red-shifted emission. Here, we report for the first time the design and synthesis of novel 9,9-spiro bifluornene-based polymers containing heteroatoms such as N, S in its molecular skeleton. Especially, the 9,9-spiro bifluornene-based polymers containing N atom showed stable blue electroluminescence, which did not show spectral change upon thermal annealing.

  • PDF

Ag-sheath Bi-2223 고온 초전도 선재 AC 손실 해석에 따른 설계 및 제작 (The Design and Manufature by Analysis of AC Loss of high temperature supercondutor wire of Ag-sheath Bi-2223)

  • 장미혜;추용;이준영;고태국
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 A
    • /
    • pp.349-352
    • /
    • 1998
  • In future superconducting electrical machines and device. AC loss in the superconducting windings are one of the most impotent design paramenters. This paper descriptions a series of Characteristic of a high-Tc superconducting Bi-Pb-Sr-Ca-Cu-O Ag-sheathed filament. In the case simulation and design to reduce ac loss is considered the filament number, twitch pith number and diameter of filament. A filament sample with Tc of 78K is made by $835^{\circ}C$ sintering for 50h and $0.33^{\circ}C$/min heating rate in an atmosphere. The experiment observations are compared with self-field loss and AC losses of Bi-Pb-Sr-Ca-Cu-O filament at 77K in following environments ; (i)AC external parallel magnetic field in different frequencies. And an analytical expression of the loss the derivation of transposition from an optimum condition was derived for the external AC magnetic field, theoretical predictions were found to coincide with the experimental observations.

  • PDF

Performance evaluation of bubble pump used on solar water heating system

  • Xuesong, Li;Park, Gi-Tae;Kim, Pil-Hwan;Chung, Han-Shik;Jeong, Hyo-Min
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.416-422
    • /
    • 2007
  • The application analysis of bubble pump on the domestic solar water heater system is presented. The system investigated in this study is a passive device, self pumping and self regulating. It was test to use the bubble pump on solar water heater system. The test experiment has been taken on the existed vacuum tube about the efficiency, working fluid temperature and pressure and circulated power. In order to check the working temperature and working pressure effectively, the bubble pump was test separated from the solar water heater. The equipment consists of the bubble pump, heater and heat exchanger. The main structure of bubble pump was design depend on the character of two phase flow. The complete system was instrumented to measure pressures, temperatures and their relationship with the solar radiation intensity. The theory analysis of design bubble pump has been given and the experiment result analysis has been included in the paper.

  • PDF