• Title/Summary/Keyword: Heating Device

Search Result 478, Processing Time 0.029 seconds

An Experimental Study on the Performance of Heat Pump Air Conditioner according to Frequency Modulator for Cooling and Heating (주파수변조장치를 이용한 열펌프식 공기조화기의 냉방-난방에 관한 실험적 연구)

  • Lee, Dae Woo;Cho, Jin Ho
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.1 no.3
    • /
    • pp.203-209
    • /
    • 1989
  • This paper is an experimental study on the pleasantly suitable cool/warm air conditioning system in order to minimize the energy consumption by attaching the electronic-controlled device to the heat pump air conditioning system.While the cool/warm air conditioning, the air temperatures in the entrance and exit of the indoor heat exchangers should be checked and when the surface of heat exchanger is reached to the dew point temperature, a speed of the compressor is to be automatically controlled by anti-dewing system in order to minimize the energy consumption.At the result of this study, the energy consuming amount is saved about 5% more than that of the conventional air conditioning system by prevent unnecessary dew forming.

  • PDF

Performance Variation of the Air Curtain for Various Discharge Angles in Feating Space (난방공간에서 에어커튼의 토출각도 변화에 따른 성능 변화)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.57-63
    • /
    • 2010
  • Air curtains are widely used for gates of shopping mall, warehouse, cold stores and refrigerated display cabinets. The purpose of the air curtain is to reduce the infiltration of outdoor air and heat loss from the air conditioning space to ambient air. The discharge angle of air curtain is very important as the sealing efficiency is affected by it. This paper presents a performance of single jet air curtain in heating space when the discharge angle of nozzle changes. A numerical simulation is used to study the influence of various parameters on the efficiency of the downward-blowing air curtain device which is installed inside of the wall above the door. The performance of the air curtain is evaluated by sealing efficiency which provides the assessment of the energy savings. A condition of discharge angle that has the highest sealing efficiency is proposed.

Fabrication and Characteristics of Hot-Film Type Micro-flowsensors integrated with RTD (측온저항체 온도센서가 집적화된 발열저항체형 마이크로 유량센서의 제작 및 특성)

  • 정귀상;홍석우
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.13 no.7
    • /
    • pp.612-616
    • /
    • 2000
  • This paper describes on the fabrication and characteristics of hot-film type micro-flowsensors integrated with Pt-RTD(resistance thermometer device) and micro-heater on the Si membrane in which MgO thin-film was used as medium layer in order to improve adhesion of Pt thin-film to SiO$_2$layer. The MgO layer improved adhesion of Pt thin-film to SiO$_2$layer without any chemical reactions to Pt thin-film under high annealing temperatures. Output voltages increased due to increase of heat-loss from sensor to external. The output voltage was 82 mV at $N_2$flow rate of 2000 sccm/min heating power of 1.2 W. The response time($\tau$:63%) was about 50 msec when input flow was stepinput

  • PDF

Development of electric surgical machine by LC series resonance (LC 직렬공진에 의한 전기 수술기 개발)

  • Lee, Oh-Keol;Kim, Tae-Woo;Song, Ho-Shin
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.153-157
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows, Therefore, this treatise developed electricity living body formation operation appliance by home production, Ultra high frequency eruption circuit used LC circuit, and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current. This developed product could microscopic operation fewer than 1 [mm]. This development technology is considered by do metallic surface heat treatment, melting, welding, induction heating device and that can apply to domestic animals surgical operation and so on.

  • PDF

Development of skin surgical machine by series resonance method (직렬공진에 의한 피부 수술기 개발)

  • Lee, Oh-Keol;Kim, Sang-Ju
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05a
    • /
    • pp.127-132
    • /
    • 2002
  • Electricity living body formation operation appliance is using most imports until present. And, because electricity living body formation operation appliance is too expensive, it becomes burden to buy in small scale hospital. Also, problem that economical damage by income is added follows. Therefore, this treatise developed electricity living body formation operation appliance by home production. Ultra high frequency eruption circuit used LC circuit. and output frequency is possible to 8 [MHz], and output voltage amplified maximum 800 [V]. This operation appliance could display size of fixed current. This developed product could microscopic operation fewer than 1 [mm]. This development technology is considered by do metallic surface heat treatment, melting, welding, induction heating device and that can apply to domestic animals surgical operation and so on.

  • PDF

Thermal Design of IGBT Module with Respect to Stability (IGBT소자의 열적 안정성을 고려한 방열설계)

  • Lee Joon-Yeob;Song Seok-Hyun
    • Proceedings of the KIPE Conference
    • /
    • 2002.11a
    • /
    • pp.205-208
    • /
    • 2002
  • Thermal design is required with considering thermal stability to verify the reliability of electric power device with using IGBT. Numerical analysis is performed to analyzed the change in thermal resistance with respect to the various thermal density of heating element. Correlations between thermal resistance and heat generation density are established. With using these correlations, performance curve is composed with respect to the change in thermal resistance of cooling conditions for natural convection and forced convection. Thermal fatigue is occurred at the Inside and outside of IGBT by repeated heat load. The crack is occurred between base plate and ceramic substrate for the inside. When the crack length is 4mm, the failure is occurred. Therefore, Thermal design method considering thermal density, thermal fatigue resistance is presented on this study and it is expected to thermal design with considering life prediction.

  • PDF

Process Design Biogas Plant of the Farm Scale livestock excretions (농가형 축산분뇨 처리를 위한 바이오가스화 공정 설계)

  • Cho, Hyun-Seob
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05a
    • /
    • pp.128-131
    • /
    • 2010
  • Recently, environmental pollution by livestock excretion is gathering strength as livestock industry is advanced on a large scale. Bio-gas is generated more than about 70 precent if remove impurities in the course of extracting bio-gas to use livestock excretion. In this paper, we developed a device that can use it in heating after extracting bio-gas from livestock excretion collected in livestock farmhouse and can supply electricity by using generator developed in itself. Also, because this system is epoch-making no discharge system to solve smear of existing method, it is expected that we have effects to prevent environmental pollution and get alternation energy and burden on the institution to treat livestock excretion of a pig breeder is solved, if use it.

  • PDF

A study on the operation efficiency protection circuit of the power supply (전원장치의 동작효율 보호회로에 관한 연구)

  • Jeong, Seong-Yun;Choi, Hyun-Su;Baek, Jong-Ok;Ahn, Tae-Young
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.93-94
    • /
    • 2014
  • Recently, According to increase of power demand, it was increased a demand that switching power supply have characteristic of low-loss and high-efficiency. So increase of using device, the failure rate increases and service life problem arises. Even though normal circuit protection is applied in designing stage, it is often hard to identify the cause of malfunction in certain cases such as fatigued power supply due to over-running, malfunctions of main elements or over heating. This report will cover experimental results with the prototype we made, that monitors the efficiency of switching power supply and that protects a circuit when it drops below the standard value.

  • PDF

Thermal characteristic of PRAM with top electrode (상부전극에 따른 상변화 메모리의 발열 특성)

  • Choi, Hong-Kyw;Jang, Nak-Won;Kim, Hong-Seung;Lee, Seong-Hwan;Mah, Suk-Bum
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.97-98
    • /
    • 2007
  • In this paper, we analyzed the reset current variation of PRAM device with top electrode using the 3-D finite element analysis tool. As thickness of phase change material thin film decreased, reset current caused by phase transition highly increased. Joule's heat which was generated at the contact surface of phase change material and bottom electrode of PRAM was given off through top electrode to which was transferred phase change material. As thermal conductivity of top electrode decreased, heating temperate was increased.

  • PDF

Establishment of an Equivalent Circuit Model and Analysis of Impedance Matching Characteristics of RF-Heating System in Hanbit Magnetic Minor Device (한빛 자기거울 장치의 고주파 가열 시스템에 대한 등가회로 모델 정립 및 정합 특성 분석)

  • Lee, Jong-Kyu;Yoon, Nam-Sik;Park, Byeong-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.568-569
    • /
    • 2005
  • 한빛 자기거울 장치는 고온 플리즈마 물성을 연구하기 위한 장치로서 플러즈마 밀도 형성을 위한 slot 형 안테나 고주파 가열 시스템이 중앙 진공용기에 설치되어 있다. 본 연구에서는 이러한 고주파 전송선로, 임피던스 정합 network. 장치 임피던스를 포함하는 한빛 장치의 고주파 가열 시스템에 대하여 기존에 정립된 고주파 가열 이론[1]을 기반으로 하여 이론적인 해석만으로 구성된 회로모델을 완성하였다. 임피던스 정합 소자 값들은 임피던스 정합 조건으로 결정함으로써 다양한 장치 및 플라즈마 변수들의 함수로 표현하여 그 의존성을 조사하였다.

  • PDF