구동장치 및 열교환기 변경에 따른 냉매가열식 열펌프의 성능특성 (Performance of a Refrigerant Heating Type Heat Pump by Changing of Driving Devices and Heat Exchangers)

  • 박윤철;김상혁;김지영
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.49-56
    • /
    • 2008
  • When the outdoor air temperature decreased less than the freezing temperature, frost forms at the surface of heat exchangers and it makes the performance degradation of a heat pump system. In this study, a heat pump system has been developed which has a refrigerant heating device as an auxiliarly heating equipment. To reduce power consumptions of the system, a liquid pump, rather than a compressor, was used to drive refrigerant in the heat pump cycle. Ratio of refrigerant mass flow between a refrigerant heating heat exchanger(GHX) and a outdoor plate heat exchanger(PHX) was varied and the system performance was measured and analyzed. As results, when the refrigerant flow rate to the GHX was decreased, the system performance is decreased due to heat absorption capability restriction of the GHX and small variation of the power consumption in the compressor. The effect on the evaporating and condensing pressure by the distribution ratio of the refrigerant to the each heat exchanger is small compare to the effect by the frequency change in the compressor. When the compressor was replaced by the liquid pump, the capacity of the system decreased a little, however the power consumption decrease approximately 80% compare with the power used in the compressor.

지역난방 중온수 펌프의 현장 성능평가를 위한 열역학적 측정법 적용 (Aplication of the Thermodynamic Measurement Method for On-site Performance Evaluation of Hot Water Pumps Used in District Heating)

  • 박철규;유호선
    • 플랜트 저널
    • /
    • 제17권1호
    • /
    • pp.50-57
    • /
    • 2021
  • 수력학적 효율측정 방법만으로는 펌프시스템 부속장치들의 개별효율 및 펌프 자체효율을 명확하게 산출해내기 매우 어렵다. 이에 본 연구에서는 국내 최초로 지역난방 중온수용 펌프시스템에 최신 열역학적 펌프 효율측정방법을 도입, 수력학적 방법과의 효율 병행측정 결과를 검토하였고, 그 결과 기존 수력학적 펌프효율 측정방법만으로는 데이터 불확실성이 높은 반면, 열역학적 및 수력학적 방법 병행측정 데이터를 적용한 펌프 및 유체커플링 효율값은 상호보완적 역할수행에 의해 펌프성능 측정방법의 신뢰성 및 적정성이 검증되는 의미 있는 결과를 도출할 수 있었다. 또한, 지역난방시스템에 열역학적 펌프효율 측정방법을 적용한 결과, 최대 120 ℃ 고온 환경에도 불구, 매우 안정적인 데이터 측정 및 측정장비의 내구성이 검증되는 등 열역학적 측정방법의 신뢰성을 검증할 수 있었다.

3D프린터를 이용한 겨울철 대류난방기구의 온도 성층화 해결을 위한 무동력 서큘레이터 디자인에 관한 연구 (The A Study on the Non-powered Circulator to Solve the Temperature Stratification of a Convection Heating Device during Winter Using 3D Printer)

  • 강희라
    • 디지털융복합연구
    • /
    • 제19권6호
    • /
    • pp.285-292
    • /
    • 2021
  • 최근 코로나19 사태로 캠핑 문화가 급속하게 많은 사람들에게 관심을 받고 있다. 많은 캠퍼들이 겨울철 사용하는 대류난방기구는 온도 성층화 문제를 가지고 있다. 이를 해결하기 위해 다양한 동력 서큘레이터가 활용되고 있다. 몇 가지 무동력 서큘레이터도 판매가 되고 있으나, 서큘레이터의 방향이 대류난방기구와 직각으로 디자인되어 있어 실제 공기 순환의 역할을 제대로 하지 못하고 있다. 이러한 문제점을 해결하고자 3D 프린터를 이용하여 대류난방기구의 방향과 같은 무동력 서큘레이터를 디자인하였다. 펠티어소자와, 세라믹페이퍼 등을 이용하여 무동력으로 전기를 만들어 냈으며, HTPLA-CF 필라멘트를 이용하여 열에 강하게 제작하였다. 3D 프린터를 이용하여 원가를 절감할 수 있었으며, 다양한 대류난방기구의 크기에 맞게 제작 할 수 있는 장점이 있다. 본 연구는 효율적인 대류순환을 통해 온도 성층화 문제를 해결할 수 있는 하나의 방법을 제시한다. 또한 3D 프린터를 이용하여 보다 저렴하게 제품을 제작하는 것이 본 연구의 목적이다.

주변 온도보상이 필요 없는 열선식 풍속 센서 시스템 (Hot Wire Wind Speed Sensor System Without Ambient Temperature Compensation)

  • 성준규;이근우;정회경
    • 한국정보통신학회논문지
    • /
    • 제23권10호
    • /
    • pp.1188-1194
    • /
    • 2019
  • 유체의 흐름을 측정하는 여러 방법 중 열선 풍속 센서는 유체의 열전달에 의해 속도나 온도를 측정하는 장치로 비정상 속도 및 난류 속도 성분을 측정하는데 유용하다. 하지만 열선 풍속 센서는 외부의 환경 요인에 민감하며, 주변 온도, 습도, 신호 잡음 등에 의해 정확도가 떨어지는 단점이 있다. 이런 단점을 보완하는 방법으로 온도 보상 회로를 추가하는 기술이 나오고 있지만 가격 경쟁력을 갖출 수 없는 상황이다. 이를 해결하기 위해 본 논문에서는 온도 보상이 필요 없는 풍속 감지 센서에 대해 연구를 진행하였다. 열선식 풍속 센서는 외부 환경 요인 중에서도 주변 온도에 매우 취약하다. 주변 온도로는 전자 회로에 의한 발열의 영향이 가장 크게 미치고 있으며, 이를 개선하는 방법으로 발열체에 보조 발열체를 추가로 장착하여 보조발열체와 발열체의 일정한 온도차를 제어하는 것이다. 이와 같이 기존 기술에 비해 복잡하지 않은 방법으로 동등한 성능을 확보할 수 있다는 것을 확인할 수 있었다.

New Solid-phase Crystallization of Amorphous Silicon by Selective Area Heating

  • Kim, Do-Kyung;Jeong, Woong-Hee;Bae, Jung-Hyeon;Kim, Hyun-Jae
    • Journal of Information Display
    • /
    • 제10권3호
    • /
    • pp.117-120
    • /
    • 2009
  • A new crystallization method for amorphous silicon, called selective area heating (SAH), was proposed. The purpose of SAH is to improve the reliability of amorphous silicon films with extremely low thermal budgets to the glass substrate. The crystallization time shortened from that of the conventional solid-phase crystallization method. An isolated thin heater for SAH was fabricated on a quartz substrate with a Pt layer. To investigate the crystalline properties, Raman scattering spectra were used. The crystalline transverse optic phonon peak was at about 519 $cm^{-1}$, which shows that the films were crystallized. The effect of the crystallization time on the varying thickness of the $SiO_2$ films was investigated. The crystallization area in the 400nm-thick $SiO_2$ film was larger than those of the $SiO_2$ films with other thicknesses after SAH at 16 W for 2 min. The results show that a $SiO_2$ capping layer acts as storage layer for thermal energy. SAH is thus suggested as a new crystallization method for large-area electronic device applications.

형상기억합금을 이용한 열박음 공구홀더 개발 (Development of Shrink-Fit Tool Holder using Shape Memory Alloys)

  • 신우철;노승국;김병섭;박종권
    • 한국생산제조학회지
    • /
    • 제19권6호
    • /
    • pp.889-894
    • /
    • 2010
  • Conventional shrink-fit tool holders have positive features, such as high accuracy, high strength, high stiffness and low sensitivity to centrifugal forces, but they require heavy investments for heating and cooling equipment. Generally the heating equipment has to heat the tool holder up to $200{\sim}300^{\circ}C$ for tool changes. This paper introduces a novel shrink-fit tool holder that is able to unclamp a tool at $40{\sim}50^{\circ}C$. This feature makes it possible to switch between the clamped and unclamped states by using a simple device, which has lower power, smaller size and lower cost than the heating equipment of the conventional shrink-fit tool holders. The proposed shrink-fit tool holder is able to expand its tool hole by using the shape memory alloys which are integrated in the tool holder body. Performances of the SMA shrink-fit tool holder were evaluated experimentally. The experimental results confirm that the proposed tool holder is feasible in aspects of clamping/unclamping operations, clamping force and repeatability of tool setup.

Carbon fiber 후막형 열전센서 소자를 이용한 적외선 체열진단 (The Method of Thermograph using Thermoelectric Sensor Device in the Carbon fiber Thick Films)

  • 송민종;동경래;김창복;최성관;박용순
    • 대한디지털의료영상학회논문지
    • /
    • 제12권2호
    • /
    • pp.145-150
    • /
    • 2010
  • Thick films of carbon fiber were prepared by a heating element of plan shape made in Darin co., We have investigated surface morphology of the specimen depending on heat-treatment temperatures. Scanning electron microscope(SEM) image of carbon fiber thick films of the specimen heat treated shows a grain growth at $1200^{\circ}C$ and becomes a poly-crystallization at $1350^{\circ}C$. The variation of resistivity at the thermally annealed specimen above $600^{\circ}C$ depends on type of the substrates. It may be due to a variation of film thickness and a difference of interfacial phenomena. A heating element of features was affected significantly by skin blood and quantity of heat of the body physiological function. After radiation of farinfrared for plate heating element, the function of biometric physiological is considered of skin blood flow and calorie which greatly affects on individuals. Electromagnetic wave was not influence on the body.

  • PDF

A Study on Magnetic Cure System Depending on Dominant Direction of Meridian using Heating Diagnosis Method

  • Kim, Byoung-Hwa;Lee, Hie-Soung;Lee, Woo-Cheol;Han, Gueon-Sang;Won, You-Seub;Sagong, Seok-Jin;Ahn, Hyun-Sik;Kim, Do-Hyun
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -3
    • /
    • pp.1776-1779
    • /
    • 2002
  • In this paper, we measured the heating time on the key measuring point of the meridian of the human body's left and right by using heating machine. Then, based on the fuzzy theory, this study diagnosed the each meridian's strength and weakness, After that, both the strengthening and weakening stimulus of magnetic field was applied to the dominant direction to find out how the degree of strength and weakness of the meridian changed. Ultimately, the magnetic therapy that can stimulate the magnetic field at the time of diagnosis and thereby balancing the interactive of a five system has been materialized. For the stimulation of magnetic field, a stimulating device which can change the direction and time on a specific part of the key measuring points has been developed and used. The therapeutic method is as follows. first, the strength and weakness of the meridian has been determined. Second, both the extremely weak meridian of Yin(Shade) and Yang(Shine), and the extremely strong meridian of Yin and Yang were adjusted by applying appropriate ascending and descending stimuli respectively.

  • PDF

박막시험편용 고온 크리프 시험기의 설계 및 제작 (Design and Construction of a High Temperature Creep Tester for Thin Film Specimens)

  • 고경득;이상신;강기주
    • 대한기계학회논문집A
    • /
    • 제31권2호
    • /
    • pp.253-259
    • /
    • 2007
  • A new material tester has been developed to measure mechanical properties of thin film specimens at high temperature. It is useful for observing oxide film growth or local deformation on the surface, and for measuring creep strength. Main characteristics of the tester is as follows; First, high temperature is achieved by Joule heating generated by electricity passing through the specimen, which does not need to enclose the specimen by a furnace or a heating chamber. The exposed specimen enables one to observe the surface during the test. Because the overall size of the test rig is compact, the whole test rig can be placed in a chamber for environmental controlled tests. The loading device is from a level scales. Not only static load with fixed counter weight, but also variable load by moving counter weight controlled remotely can be applied for an ordinary creep test and creep-fatigue test, respectively. The detail of the construction, operation principle, and the specification are described. And also, an example of test result obtained using the creep tester is presented.

미세 와이어의 전단에 관한 연구 (A study on the shearing of the straightened micro-wire)

  • 신용승;홍남표;김병희;김헌영;김웅겸
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 금형가공,미세가공,플라스틱가공 공동 심포지엄
    • /
    • pp.175-180
    • /
    • 2005
  • In this study, we have developed a novel wire straightener which uses the direct heating method (DHM) fer straightening the micro wire. Also, we have developed a shearing device for cutting the micro wire. In order to avoid the surface oxidization, we supplied the inert gas(Ar) during the heating process and examined the effect of gas flow rate. The effects of the tension and the current applied to the tungsten micro wires were also thoroughly studied. From various experiments and analyses, we could obtain fine straightness $(\approx1\;{\mu}m/1000\;{\mu}m)$ and roundness $(<{\pm}2{\mu}m\;/100{\mu}m)$ when the tension is $500\~~600gf$ and the current is about 1.5A. for burrfree cutting, counter-punch method which two cutters moving contrary was used. The cutting blade has various U-groove angle where upper $10^{\circ}$, $mid:25^{\circ}$, lower $0^{\circ}$. After the shearing process, we confirmed the shearing section.

  • PDF