• Title/Summary/Keyword: Heating Curve

Search Result 220, Processing Time 0.022 seconds

Design of Low-Melting Metal Fuse Elements of Current Sensing Type Protection Device for Large Capacity Secondary Battery Protection System (대용량 이차전지 보호 시스템용 전류 감지 동작형 보호소자의 저융점 금속 가용체 설계)

  • Kim, Eun Min;Kang, Chang yong
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.31 no.6
    • /
    • pp.427-432
    • /
    • 2018
  • High-capacity secondary batteries can cause explosion hazards owing to microcurrent variations or current surges that occur in short circuits. Consequently, complete safety cannot be achieved with general protection that is limited to a mere current fuse. Hence, in the case of secondary batteries, it is necessary for the protector to limit the inrush current in a short circuit, and to detect the current during microcurrent variations. To serve this purpose, a fuse can be employed for the secondary battery protection circuit with current detection. This study aims at designing a protection device that can stably operate in the hazardous circumstances associated with high-capacity secondary batteries. To achieve the said objective, a detecting fuse was designed from an alloy of low melting point elements for securing stability in abnormal current states. Experimental results show that the operating I-T and V-T characteristic constraints can be satisfied by employing the proposed current detecting self-contained low melting point fuse, and through the resistance of the heating resistor. These results thus verify that the proposed protection device can prevent the hazards of short circuit current surges and microcurrent variations of secondary batteries.

A Study on Composition and Dosimetry of the $CaSO_4$ Phosphors ($CaSO_4$ 열형광체의 조성과 선량측정에 관한 연구)

  • Lee, Duek-Kyu
    • Journal of radiological science and technology
    • /
    • v.21 no.1
    • /
    • pp.59-64
    • /
    • 1998
  • [ $CaSO_4$ ] thermoluminescent phosphors was made by sintring the $CaSO_4$ after doping the transition elements Tm, Pd, Dy, V, Mo, Zr. The maximum Peaks are found in the measured $CaSO_4$(Tm, Pd, Dy, V, Mo, Zr) TL glow curve at $130^{\circ}C,\;110^{\circ}C,\;140^{\circ}C,\;100^{\circ}C$, and $120^{\circ}C$ when the heating rate is $5^{\circ}C/sec$. The activation energy of the main peak has been estimated by the peak shape method. The estimated activation energies are 1.02eV, 1.32eV, 1.12eV, 0.80eV, and 1.17eV, respectively. The thermoluminescence process in $CaSO_4$(Tm, Pd, Dy, V, Mo, Zr)are found to the 2nd order when the main peak of the glow curve is analyzed by peak shape method. The dose responses of $CaSO_4$(Tm, Pd, Dy, V, Mo, Zr) phosphors are linear within $4{\times}10^{-4}{\sim}1Gy$ of X-rays.

  • PDF

Design of Fuse Elements of Current Sensing Type Protection Device for Portable Secondary Battery Protection System (휴대용 이차전지 보호 시스템용 전류 감지 동작형 보호소자의 퓨즈 가용체 설계)

  • Kang, Chang-Yong;Kim, Eun-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.12
    • /
    • pp.1619-1625
    • /
    • 2018
  • Portable electronic devices secondary batteries can cause fire and explosion due to micro-current change in addition to the situation of short-circuit inrush current, safety can not be secured with a general operation limited current fuse. Therefore, in secondary battery, it is necessary for the protector to satisfy both the limit current type operation in the open-short-circuit inrush current and the current detection operation characteristic in the micro current change situation and for this operation, a fuse for the current detection type secondary battery protection circuit can be applied. The purpose of this study is to design a protection device that operates stably in the hazardous situation of small capacity secondary battery for portable electronic devices through the design of low melting fuse elements alloy of sensing type fuse and secures stability in abnormal current state. As a result of the experiment, I-T and V-T operation characteristics are satisfied in a the design of the alloy of the current sensing type self-contained low melting point fuse and the resistance of the heating resistor. It is confirmed that it can prevent accidents of short circuit over-current and micro current change of secondary battery.

Thermal stress intensity factor solutions for reactor pressure vessel nozzles

  • Jeong, Si-Hwa;Chung, Kyung-Seok;Ma, Wan-Jun;Yang, Jun-Seog;Choi, Jae-Boong;Kim, Moon Ki
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2188-2197
    • /
    • 2022
  • To ensure the safety margin of a reactor pressure vessel (RPV) under normal operating conditions, it is regulated through the pressure-temperature (P-T) limit curve. The stress intensity factor (SIF) obtained by the internal pressure and thermal load should be obtained through crack analysis of the nozzle corner crack in advance to generate the P-T limit curve for the nozzle. In the ASME code Section XI, Appendix G, the SIF via the internal pressure for the nozzle corner crack is expressed as a function of the cooling or heating rate, and the wall thickness, however, the SIF via the thermal load is presented as a polynomial format based on the stress linearization analysis results. Inevitably, the SIF can only be obtained through finite element (FE) analysis. In this paper, simple prediction equations of the SIF via the thermal load under, cool-down and heat-up conditions are presented. For the Korean standard nuclear power plant, three geometric variables were set and 72 cases of RPV models were made, and then the heat transfer analysis and thermal stress analysis were performed sequentially. Based on the FE results, simple engineering solutions predicting the value of thermal SIF under cool-down and heat-up conditions are suggested.

Evaluation of Thermal Processes for Canned Marine Products (3) Canned Minced Hen-Clams in Brine and Canned Smoked Baby-Clams in Oil (수산물 통조림의 살균조건에 관한 연구 (3) 개량조개 세절 보일드 통조림 및 바지락 훈제 기름담금 통조림)

  • PARK Yeung-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.4
    • /
    • pp.306-312
    • /
    • 1984
  • In the present study, in succession to the previous reports, the sterilizing values ($F_0$) of the thermal processes for the canned minced hen-clams in brine and the canned smoked baby-clams in oil were determined ana discussed. The heat penetration tests were carried out three times with three cans at a time for each canned product. The thermocouple was setted on the can so as the tip of the applicaotor fixed on the position a little below the geometrical center of the can. The test cans were placed in the middle layer of the crate in which the same canned products were loaded with, and test cans were arranged to the front, the middle and the rear in the retort. The heat penetration curve obtained for the canned minced hen-clams in brine showed a broken logarithmic heating curve, while that of the canned smoked baby-clams in oil showed a simple logarithmic heating curve. The calculated $F_0$ values for the canned minced hen-clams in brine were 47.79 for No. 2 can, 52.99 for Ne. 7 can. and 45.21 for No. 2 tuna can, respectively. And the $F_0$ value for th canned baby-clams in oil packed into No. 3B square can was 14.12. Additionally, the nomographs represent the relationship between $F_0$ vlaues and B values (process time including $42\%$ of come-up time) for the each canned product were constructed.

  • PDF

Evaluation of Thermal Processes for Canned Marine Products (1) Canned Boiled Sea-mussel in Brine and Canned Smoked Sea-mussel in Oil (수산물통조림의 살균조건에 관한 연구(1) 홍합 보일드 통조림 및 홍합 훈제 기름담금 통조림)

  • PARK Young-Ho
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.17 no.3
    • /
    • pp.159-164
    • /
    • 1984
  • The present studies were conducted to evaluate the sterilizing efficiency of the thermal processes for the canned sea-mussel products, such as canned boiled sea-mussel in brine (packed into No. 1 flat can) and canned smoked sea-mussel in oil (packed into No. 3B square can), with the purpose of deciding the adequacy of the processes. Heat penetration was tested three times with three cans at a time for each canned product. The tip of the applicator was fixed on the position a little below the geometrical center of the can. The test cans were placed in the middle layer of the basket in which the same canned products were loaded with, and the test cans were arranged to the front, the middle and the rear in the retort. The heat penetration curve of the canned boiled sea-mussel in brine showed a broken logarithmic heating curve while that of the canned smoked sea-mussel in oil showed a simple logarithmic heating curve. The calculated $F_0$ value for the canned boiled sea-mussel in brine was 25.33 and the canned smoked sea-mussel in oil was 13.84. Additionally, the nomographs represents the relationship between $F_0$ values and B values(process time including $42\%$ of come-up time) for the canned sea-mussel products were constructed.

  • PDF

A Study on the Strength Properties and the Temperature Curve of Winter Concrete According to the Difference of Curing Method in Mock-up Test (실물부재시험에서의 양생방법 차이에 따른 한중콘크리트외 온도이력 및 강도특성에 관한 연구)

  • Kim, Young-Jin;Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon
    • Journal of the Korea Concrete Institute
    • /
    • v.15 no.4
    • /
    • pp.541-548
    • /
    • 2003
  • This study is to investigate the temperature curve and development of compressive strength due to the curing conditions and to evaluate the optimum curing condition of test specimens showing the same development of strength to that of real structures in cold weather. The results of temperature curve with curing conditions in mock-up tests showed the trend of decrease plain concrete with insulation form, plain concrete with heating, concrete with accelerator for freeze protection, and control concrete in turn. The strength development of plain concrete of inside and outside of shelter showed the very slow strength gains due to early freezing, but that of concrete with accelerator for freeze protection showed the gradual increase of strength with time. From this, it is clear that accelerator for freeze protection has the effects of reducing the freezing temperature and accelerating the hardening under low temperature. Strength test results of small specimens embedded in members and located in insulation boxes at the site are similar to that of cores drilled from the members at the same ages, thus it is clear that these curing methods are effective for evaluation in-place concrete strength.

Heat Penetration Characteristics and Keeping Quality of Retort Pouched Curry (레토르트 파우치 카레의 전열특성 및 품질안정성)

  • Koo, Bon-Youl;Park, Seong-Joon;Byeon, You-Ryang;Son, Se-Hyeong
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.63-68
    • /
    • 1993
  • Heat penetration characteristics of retort pouched curry were studied to determine optimal sterilization conditions. Heating curve of retort pouched curry showed a simple logarithmic curve. The $f_h$ value (min.) of solid part in retort pouched curry was 1 min. higher than that of liquid part. $f_h$ value (min.) and $j_h$ value (heating lag factor) ranged from 8.3 min. to 12 min. and 1.0 to 1.17 respectively with increasing the ratio of solid to liquid and viscosity. $f_h$ value (min.) and $j_h$ value were significantly increased from 7.4 min. to 12.6 min. and 1.0 to 1.14 respectively with increasing thickness of the pouch from 11 to 15 mm. The low and medium volatile aroma components of retort pouched curry decreased during sterilization, which increased the high volatile aroma components. The retort pouched curry processed at $120^{\circ}C$, for 24 min. with $F_o$, value of $8{\sim}9$ could keep up a desirable quality without any remarkable deterioration.

  • PDF

Study on the Internal Temperature of Flame Resistant Treated Wood Exposed to a Standard Fire (표준화재에 노출된 방염처리 목재의 내부온도에 관한 연구)

  • Kim, Hwang-Jin
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.14-18
    • /
    • 2018
  • The earlier studies on the fire resistance performance of woods used as building materials have focused on confirming combustion characteristics of fire retardant or flame resistant treated wood. In this paper, to confirm internal temperature changes closely related to pyrolysis of woods exposed to the flame, heating experiments were conducted in a heating furnace according to the standard heating temperature curves after Douglas-fir, which is widely used as structural materials, was treated with a flame resistant solution and flame retardant paint. As a result of the experiment, it was confirmed that the thermal diffusion inside the wood has decreased when the wood was treated with the flame resistant solution. However, in high temperature, the flame resistant effect could not be expected due to the peeling of the coating in the case of the flame resistant paint treated wood. Therefore, it can be considered that it is more effective to use the flame resistant solution which penetrates in to the inside of the wood than flame resistant paint which forms the coating on the surface of the wood in order to enhance the flame resistance effect on the thick wood.

Evaluation for Noise Reduction of the HVAC by Modification of CAM Curve (CAM 곡선 개선에 의한 차량용 공조기의 소음 저감 평가)

  • Jeong, J.E.;Jung, C.Y.;Seo, B.J.;Jeong, U.C.;Oh, J.E.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.787-797
    • /
    • 2011
  • The noise in a vehicle is an important factor for customers purchasing a car. Particularly, reduction of the noise that is generated from HVAC(heating, ventilation and air conditioning) is very important since it has considerable effects on interior noise. In general, identification of noise source is crucial to reduce noise level. The complex acoustic intensity method is widely used to obtain the accurate measurement and identification of noise source. Therefore, in the previous study, noise source of HVAC was identified through experimental approach using the complex acoustic intensity method. In this study, we are intended to confirm reduced level of noise by comparing the result between before and after modification of cam curve that is based on identified noise source of HVAC. It is found out that noise source of HVAC are motor and cam area using the complex acoustic intensity method in the previous study. We performed experiments to compare noise level between before and after modification of cam curve. Especially, it can be seen that complex acoustic intensity method using both active and reactive intensity is vital in devising a strategy for comparison to noise level. Also, the vector flow of acoustic intensity was investigated to identify sound intensity distributions and energy flow in the near field of HVAC.