• Title/Summary/Keyword: Heating Condition

Search Result 1,304, Processing Time 0.026 seconds

Optimization of Liquid Desiccant Cooling Cycle (액체 제습식 냉방 사이클의 최적화)

  • Kim, Seon-Chang;Kim, Young-Lyoul;Lee, Sang-Jae;Jeon, Dong-Soon;Choi, Jaug-Hyeon;Kwon, Hyeok-Min;Lee, Chang-Jun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.673-678
    • /
    • 2009
  • This paper presents the optimization process of liquid desiccant cooling cycle using LiCl aqueous solution as a working fluid. Operating conditions and design factors for heat exchangers were optimized by response surface method. As a result, we obtained the 7.297 kW of cooling capacity and 0.788 of COP at optimized condition. Effect of $dT_{hw}$ on system performances was also examined. As $dT_{hw}$ increases, the cooling capacity increases and COP decreases.

  • PDF

A Study on the Riskiness of Dust Explosion of Feed-Stuff (가축사료의 분진폭발 위험성에 관한 연구)

  • 이창우;함영민;김정환;현성호
    • Fire Science and Engineering
    • /
    • v.12 no.2
    • /
    • pp.61-68
    • /
    • 1998
  • According to the results for the thermodynamic stability of feed-stuff dust, there are little change of initiation temperature of heat generation and heating value for used particle size. But initiation temperature of heat generation decreased with high heating rate whereas decomposition heat increased with particle size. Using the supporting gas, O2, initiation temperature of heat generation decreased remarkably than using the inert gas, N2, and heating value increased as twenty times under the same condition. When the ignition energy is given from the outside, used fine particle which can float in the air easily reacted tremendously with oxygen. Average maximum explosion pressure was 6.88 Kgf/$\textrm{cm}^2$ for 80/100 mesh.

  • PDF

Characterizing Animal-fats Biodiesel as Heating Fuel for Agricultural Hot Air Heater (농업용 온풍난방기에서 동물성바이오디젤의 연소특성)

  • Kim, Youngjung;Park, Seokho;Kim, Chungkil;Kim, Yeoungjin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.115-115
    • /
    • 2011
  • Biodiesel (BD) was made from animal-fats reacting with methanol and potassium hydroxide in the laboratory. The biodiesel made in the laboratory was sent to K-petro, the government agency, to inspect the quality of animal-fats biodiesel, of which generally the quality was acceptable for heating oil for agricultural hot air heater. Kinematic viscosity and calorific values of the biodiesels were measured. BD20(K), kerosene based biodiesel, showed 18cSt at $-20^{\circ}C$. It seems that BD100 can not be suitable for heating fuel under some temperature. As BD content increased calorific value decreased, up to 40,000J/g for 100% BD, while light oil calorific value was 45,567J/g, showing difference of 5,567J/g, about 12% difference. Several different fuels, BD20, BD50, BD100 and light oil, were prepared and tested for fuel combustion qualities for agricultural hot air heater and their combustion performances were compared and analyzed. Flame dimensions of biodiesels and light oil were almost same shape at the same combustion condition in the burner of the hot air heater. Generally $CO_2$ amounts of BDs are greater than light oil. But,the differences are so small that it is hard to tell there was significant difference existed between the BDs combustion and light oil.

  • PDF

The Study of Aerodynamic Heating Characteristics for the Design of Nose Shapes of Space Launcher (발사체 선두부의 공력가열현상 특성연구)

  • Choi, Won;Kim, Kyu-Hong;Lee, Kyung-Tae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.30 no.6
    • /
    • pp.14-20
    • /
    • 2002
  • The aerodynamic heating at a nose cone is predicted under the KSR-III flight conditions. An equilibrium reacting gas condition is applied. The parametric study is performed with Mach number of 4.9, 10.2 and 15 and for the following nose shapes of hemisphere, cut cylinder and parabola. AUSMPW+ and shock aligned grid technique are used to provide the best aerodynamic solutions. In addition, the composite material of a nose cone is discussed in the viewpoint of a thermal safety.

The Analysis of Physicochemical and Sensory Characteristics in Brown Stock - Comparison of Traditional Method and High-Pressure Extracted Method - (갈색 육수의 이화학적 및 관능적 특성 분석 - 전통 방식과 고압 가열 방식 비교 -)

  • Choi, Soo-Keun;Jang, Hyuk-Rae;Rha, Young-Ah
    • Culinary science and hospitality research
    • /
    • v.14 no.3
    • /
    • pp.196-209
    • /
    • 2008
  • This study was conducted to mass-produce brown stock optimized by using a high-pressure heating extractor and to use brown stock as a material for developing various products. For these purposes, we attempted to produce standardized brown stock by extracting brown stock using a high-pressure heating extractor and compared it with brown stock extracted by the traditional method in terms of general elements and mechanical and sensory characteristics. With regard to how to prepare optimal brown stock, the best brown stock was that extracted seven times repeatedly by the traditional method, but the method had a large economic loss in terms of material consumption and took a long time in extraction. Thus, considering time and labor, it was concluded that extraction at 120$^{\circ}C$ for 15 hours using a high-pressure heating extractor is the optimal extraction condition in terms of economic efficiency and quality. The results of this study are expected to be useful as a practical material for making brown stock production process more convenient, applying cooks' traditional cooking techniques to mass production, maintaining standardized superior quality and taste, and improving shelf life.

  • PDF

Effect of the Exhaust Heat from Micro Gas Turbine on the Performance Characteristics of the Absorption Chiller (마이크로가스터빈 배열부하가 배가스흡수식 냉온수기의 성능에 미치는 영향)

  • Choi Kyoung-Shik;Sohn Wha-Seung;Kim HyoungSik;Rhim Sang-Kyu;Hur Kwang-Beom
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.2
    • /
    • pp.158-162
    • /
    • 2006
  • Micro gas turbine (MGT) has received attention recently as a small-scale distributed power source. Due to many advantages such as their small size, low maintenance cost and minimal vibrations during operation, they are expected to become widespread in a wide range of applications. The exhaust heat emitted by the MGT is in the form of an exhaust gas that is about $270^{\circ}C$ which is an extremely clean gas. Korea Gas Corporation (KOGAS) has researched performance characteristics of a cogeneration system combining 28kW class MGT and 13 USRT class absorption hot and chilled water generator in the local condition. The present results of this study can be summarized as follows: (1) in heating mode, the total efficiency of cogen. system is about $65\%$ and heating capacity is 33kW at 25kW MGP power (2) in cooling mode, COP is about 0.6 at 22kW MGT power.

Optimization Design of Liquid Desiccant Cooling System (액체 제습식 냉방 시스템의 최적 설계)

  • Jeon, Dong-Soon;Lee, Sang-Jae;Kim, Seon-Chang;Kim, Young-Lyoul;Lee, Chang-Jun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.7
    • /
    • pp.419-428
    • /
    • 2010
  • This paper presents the optimization process of liquid desiccant cooling system using LiCl aqueous solution as a working fluid. Operating conditions(mass flow rate, conditioner outlet concentration, difference concentration) and design factors for heat exchangers(difference temperature of the district heating water, leaving temperature difference of the conditioner, leaving temperature difference of the regenerator, air temperature difference of the conditioner, air temperature difference of the regenerator) were optimized by response surface method. As a result, we obtained the 7.297 kW of cooling capacity and 0.788 of COP at optimized condition. Effect of difference temperature of hot water on system performances was also examined. As difference temperature of the district heating water increases, the cooling capacity increases and COP decreases.

Heating Behavior of Silicon Carbide Fiber Mat under Microwave

  • Khishigbayar, Khos-Erdene;Seo, Jung-Min;Cho, Kwang-Youn
    • Journal of the Korean Ceramic Society
    • /
    • v.53 no.6
    • /
    • pp.707-711
    • /
    • 2016
  • A small diameter of SiC fiber mat can produce much higher heat under microwave irradiation than the other types of SiC materials. Fabrication of high strength SiC fiber consists of iodine vapor curing on polycarbosilane precursor and heat treatment process. The curing stage of polycarbosilane fiber was maintained at $150-200^{\circ}C$ in a vacuum condition under the iodine vapor to fabricate a high thermal radiation SiC fiber. The structure and morphology of the fibers were characterized by Fourier transform infrared (FTIR) spectroscopy, thermogravimetric analysis (TG) and scanning electron microscopy (SEM). In this study, the thermal properties of SiC fiber mats under microwave have been analyzed with an IR thermal camera and its image analyzer. The prepared SiC fiber mats radiated high temperature with extremely high heating rate up to $1100^{\circ}C$ in 30 seconds. The fabricated SiC fiber mats were not oxidized after the heat radiation process under the microwave irradiation.

Performance of the Cooling and Heating of Heat Pump Using Non-azeotropic Refrigerant Mixtures (비공비혼합냉매를 이용한 열펌프의 냉난방성능에 관한 연구)

  • 박기원;오후규
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.4
    • /
    • pp.53-61
    • /
    • 1994
  • An experimental study on heat pump cycle systematizing characteristics for non-azeotropic refrigerant mixtures of R-22+R-114 was reported. Data were obtained under steady state condition at the ranges of parameters, 550- 2, 170kcal/h, 670-2, 990kcal/h, 24-71kg/h, and 0-1, for as cooling capacity, heating capacity, mass 25, 50, 75, and 100 per cent of R-22 by weight fraction for R-22+R-114 mixtures. The results shown that the C.O.P of the 50wt% of R-22 mixture was considerably larger than for pure R-22 and other weight fraction of R-22 mixtures, but the compression power of the 25wt% of R-22 was lower than that of the pure R-22 and the other weight fraction of R-22 mixtures. The hightest value of cooling capacity was obtained at the conditions of evaporating temperature 5.deg.C and R-22 50wt% mixture. In general, with an increase in the R-22 weight fraction for fixed values of the other parameter, the cooling capacity increased at first, obtained a maximum, and then decreasd. This verified the importance of accurate weight fractions od refrigerant mixtures in the heat pump cycle.

  • PDF

Direct Numerical Simulation of Strongly-Heated Internal Gas Flows with Large Variations of Fluid Properties (유체의 물성치변화를 고려한 수직원형관내 고온기체유동에 관한 직접수치모사)

  • Bae, Joong-Hun;Yoo, Jung-Yul;Choi, Hae-Cheon;You, Jong-Woo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.11
    • /
    • pp.1289-1301
    • /
    • 2004
  • Direct numerical simulation (DNS) of strongly-heated air flows moving upward in a vertical tube has been conducted to investigate the effect of gas property variations on turbulence modification. Three heating conditions(q$_1$$^{+}$=0.0045, 0.0035 and 0.0018) are selected to reflect the experiment of Shehata and McEligot (1998) at the inlet bulk Reynolds numbers of 4300 and 6000. At these conditions, the flow inside the heated tube remains turbululent or undergoes a transition to subturbulent or laminarizing flow. Consequently, a significant impairment of heat transfer occurs due to the reduction of flow turbulence. The predictions of integral parameters and mean profiles such as velocity and temperature distributions are in excellent agreement with the experiment. The computed turbulence data indicate that a reduction of flow turbulence occurs mainly due to strong flow acceleration effects for strongly-heated internal gas flows. Thus, buoyancy influences are secondary but not negligible especially for turbulent flow at low heating condition. Digital flow visualization also shows that vortical structures rapidly decay as the heating increases.s.