• Title/Summary/Keyword: Heating Condition

Search Result 1,304, Processing Time 0.028 seconds

A Study on Phase Transformation and Microstructure Control of $Al_2O_3$ ($Al_2O_3$의 상전이 및 그에 따른 미세구조 제어에 관한 연구)

  • 신상현;오창섭;최성철
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.6
    • /
    • pp.553-560
    • /
    • 1997
  • A fine $\alpha$-Al2O3 powder was prepared by sol-gel process for membrane application. And it was carried out by adding 1.5wt% $\alpha$-Al2O3 powders(mean size : 87 nm) as seeds to the prepared sols and by controlling the heating schedule (the heating rate and the soaking time) to prevent the microstructural change, which occured during $\theta$-to $\alpha$Al2O3 phase transformation. The seeded $\alpha$-Al2O3 particles acted as the heterogeneous nucleation sites for the $\alpha$-Al2O3 nucleation during the transformation of $\theta$- to $\alpha$-Al2O3 and resulted in increasing the driving force of phase transformation to activate the formation of $\alpha$-Al2O3 phase at 82$0^{\circ}C$. By $\alpha$-Al2O3 seeding and controlling of heating condition the phase transformation of $\theta$- to $\alpha$-Al2O3 was accomplished at low temperature and the grain growth process was depressed. Therefore, the unsupported membrane could be fabricated in $\alpha$-Al2O3 . The average diameter of pores in the fabricated membrane was 7 nm and the porosity was 47%.

  • PDF

A Study on the Establishment of Optimum Design Conditions and Economic Evaluation for Rot Water Heating Solar Energy System (태양열(太陽熱) 급탕(給湯)시스템의 최적설계(最適設計) 조건(條件)의 설정(設定)과 경제성(經濟性) 평가(評價)에 관한 연구(硏究))

  • Lee, Young-Soo;Lee, Ki-Woo
    • Solar Energy
    • /
    • v.6 no.1
    • /
    • pp.47-59
    • /
    • 1986
  • This paper presents the establishment of optimum design conditions and economic evaluation for solar hot water system. The aim of this study is to present thermal performance of solar heating systems and to determine their performance as a function of collector size, storage capacity, tilting of collector and other factors. By analyzing its performance under the various conditions, optimum design of solar heating system can be obtained. System performance are obtained monthly and yearly basis respectively. At the same time the economics of various systems are evaluated. For the computer simulation Mokpo, Kangnung, Chupungnyong and Seoul are selected for particular installation places. As a result, the optimal design condition of solar heating system considering the following factors such as installation angle of collector, capacity of storage tank, collector size in each place can be obtained as follows; (1) Installation angle of collector Tilt = lattitude (2) Capacity of storage tank Solar domestic hot water system : $45\;1/m^2$ Multifamily solar domestic hot water system : $35\;1/m^2$ (3) Collector size i) Solar domestic hot water system Seoul & Chupyungyong area : $11.52\;m^2$ Mokpo area : $8.64\;m^2$ ii) Multifamily solar domestic hot water system Seoul, Chupyungyong & Mokpo area : $345.6\;m^2$ Kangnung area : $259.2\;m^2$

  • PDF

Heating and Cooling Load according to the Climatic Conditions of Foreign Cities (해외 주요 도시의 기후특성에 따른 최대공조부하 요소별 분석)

  • An, Seung-Hyun;Kim, Jong-Ho;Lee, Jung-Hun;Lee, Sang-Yup;Song, Doo-Sam
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.5
    • /
    • pp.81-87
    • /
    • 2014
  • According to the domestic construction business will continue stagnant, many domestic construction companies are expanding their business into foreign countries. As results, building design guidelines including HVAC design for foreign countries considering the regional climate conditions are needed. Also, green building design strategies to minimize the heating and cooling load are key issue to win a contract in construction business in the world. In this study, peak heating and cooling loads were calculated for the representative cities in the world : Seoul, St. Petersburg, Singapore and Mecca. The analyzed building was a typical high-rise office building and the building envelope properties, indoor heat gain, residence and operating schedules were same in all cases. Only the weather conditions were different by cases.

A Study for Flow-rate Balancing when the System Resistance Changes in the Control of the Radiant Floor Heating System (온돌난방제어 시 시스템저항 변화에 따른 유량 밸런싱에 관한 연구)

  • Choi, Jeong-Min;Lee, Kyu-Nam;Ryu, Seong-Ryong;Kim, Kwang-Woo;Yeo, Myoung-Souk
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.129-134
    • /
    • 2005
  • The behavior of whole system is affected by a minor change of system in the hydronic radiant floor heating system. Under partial load condition, the change of system resistance causes overflow of supply water. This unexpected effect is the cause of several problems in the heating system. In this study, we find some factors were validated with several computer simulations. After validation of this result, several conceptual solutions are evaluated to prevent overflow.

  • PDF

Study on the Effect of Induction Heating with Alloying Elements for the Pre-Heat Treated Steel of 100kgf/$mm^2$ Tensile Strength (100Kgf/$mm^2$급 선조질강의 합금원소에 따른 유도가열효과에 관한 연구)

  • Park, J.T.;Ahn, S.T.;Kwon, D.H.;Seo, J.H.;Kang, N.H.;Youn, D.J.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.40-43
    • /
    • 2009
  • This study is for investigating the effect of induction heating with various alloy elements to manufacture the pre-heat treated steels of 100kgf/$mm^2$ for cold heading. For four kinds of steels, the condition of induction heating (especially, induction tempering) were observed, and their microstructure and tensile and compressive properties were investigated. The middle carbon steel and the low carbon Cr-Mo steel are needed the higher Grange-Baughman tempering parameter than that of the low carbon Cr steel to obtain 100kgf/$mm^2$ tensile strength. For accomplishing the pre-heat treated steel of 100kgf/$mm^2$ tensile strength having advanced cold heading. It is needed that the pre-heat treated steel is manufactured by induction quenching and tempering with the low carbon alloy steel to have the high ratio of ferrite and the fine globular cementite simultaneously.

  • PDF

The Effect of Oxidation Heat Treatment on Porcelain to Metal Bond Strength (도재용착주조관용 비귀금속 합금의 사전 열처리가 도재-금속의 결합 강도에 미치는 효과)

  • Kim, C.Y.;Nam, S.Y.
    • Journal of Technologic Dentistry
    • /
    • v.19 no.1
    • /
    • pp.37-42
    • /
    • 1997
  • The interfacial bond strengh and microstructural analysis of pre-heat treated porcelain-fusedmetal(PFM) were investigated using a mechanical three-point bending tester and scanning electron microscope(SEM). Four kinds of heat treated samples were prepared as follows ; A: Heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating ${\to}1850^{\circ}F$, hold 3min under vacuum, B: heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating${\to}1850^{\circ}F$ under vacuum conditon, C: heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating${\to}1850^{\circ}F$, holding 3min in the air, repeat same heat treatment process under vacuum condition, D: heating $1200^{\circ}F{\to}1600^{\circ}F$, holding 1min, reheating${\to}1850^{\circ}F$, holding 1min in the air. The three-point bening test result shows that the interfacial bond strength of specimen B and C were higher than that of A and D. The SEM study indicate that Specimen C shows the highest surface density.

  • PDF

Performance and Heat transfer Characteristics of Louver Fin-tube Heat Exchanger for Simultaneous Cooling/Heating Heat Pump (동시 냉난방 히트펌프용 루버핀-관 열교환기 성능 및 전열특성 실험연구)

  • Kwon, Young-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.6
    • /
    • pp.1337-1342
    • /
    • 2007
  • An experimental study has been performed to investigate the performance and heat transfer characteristics of the heat exchanger for simultaneous cooling/heating heat pump. The heat transfer performance was measured using an air-enthalpy calorimeter and a constant temperature water bath, to obtain the performance evaluation and analysis of a fined tube heat exchanger. Six finned tube heat exchangers with louver fin were tested under a heating condition. Air-side heat transfer and friction were presented in terms of j-factor and f-factor. The heat transfer coefficient increased with decreasing the fin pitch, j-factor and f-factor on the fin pitch and the number of tube rows decreased with increasing Reair.

  • PDF

Effect of Air-earth Heat Exchange System on Growth of Leafy Lettuce in Greenhouse (온실내 잉여에너지 이용을 위한 지중 열교환 시스템의 상추 재배 효과)

  • Paek, Yee;Jeon, Jong-gil;Yun, Nam-kyu;Kang, Geum-Choon;Lee, Si-Young
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.4
    • /
    • pp.71-76
    • /
    • 2011
  • Earth to air heat exchangers made by iron, aluminium, copper and poly-ethylene pipe for single greenhouse heating were experimented and blowers. Earth to air heat exchanger was installed by pipelines in earth tube at 70cm depths and air blower was the heating capacity 3kW/h, As the result, Temperature difference due to temperature history of the inlet and outlet air on the various type in earth tube in greenhouse showed that air temperature at the various type in earth tube, comparison tube were make no difference respectively. Under the experimental condition, heat fluxes and heating load were showed 6,800Kcal/h, 19,699kcal/h generally yield of Lactuca Sativa cultured during days of sowing 90day in greenhouse using copper pipe was 170% incleased.

Development of Micro-Ceramic Heater for Medical Application (의료용 소형 세라믹스 히터 소자의 개발)

  • Lee, Seung-Min;Lee, Kwang-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.219-229
    • /
    • 2022
  • In this study, we propose a miniaturized micro-ceramic heater device. After screen-printing a silver paste between pre-sintered two aluminum oxide plates to integrate a heating circuit, the device was fabricated through a low-temperature sintering process. In order to configure the optimal heating circuit integration condition, the output current evaluation and heating test were performed according to the number of screen prints of the silver paste at various voltages. A silver paste-based heating circuit printed with a line width of 200 ㎛ and a thickness of 60 ㎛ was successfully integrated on a pre-sintered alumina substrate through a low-temperature sintering process. In the case of the 5 times printed device, the thermal response showed a response rate of 18.19 ℃/sec. To demonstrate feasibility of the proposed device in the medical field, such as bio-tissue suturing and hemostasis, a voltage was applied to pig tissue in the device to test tissue change due to heat generated from the device. These results show the possibility that the proposed small ceramic heater could be used in the medical field based on its excellent temperature response.

Control of Root-Knot Nematode(Meloidogyne incognita Chitwood) by Root Zone Warming System (지중가온시설을 이용한 고구마뿌리흑선충 방제)

  • 신용습;연일권;최성국;최부술;이우승
    • Journal of Bio-Environment Control
    • /
    • v.7 no.2
    • /
    • pp.139-143
    • /
    • 1998
  • This experiment was conducted to investigate the effect of soil heating on control of root-knot nematode(Meloidogyne incognita Chitwood) by root zone warming system. Root zone was warmed by hot water flowing through pipe set at 35cm depth from the ridge The lowest soil temperatures at 20cm depth were set at 3$0^{\circ}C$, 4$0^{\circ}C$, $50^{\circ}C$ and non-warming. under soil submerging condition and non-submerging condition. Soil heating was done for 5 days(120 hours) from Aug. 1 to Aug. 5. The root-knot nematode juvenile densities of 4$0^{\circ}C$ under submerging condition. and $50^{\circ}C$ under non-submerging condition were 0 which was expected lower than the economic injury level. The contents of OM P$_2$ $O_{5}$, Ca Mg and EC in soil were decreased by root zone warming The EC was considerably lowered under submerging condition.

  • PDF