• Title/Summary/Keyword: Heating Condition

Search Result 1,304, Processing Time 0.026 seconds

Constructability of a Waterproofing Sheet Joint Combining an Aluminum Thin-film and Viscosity Layer Using a High-frequency Inductive Heating Apparatus (고주파 유도가열 장치를 이용한 알루미늄 박판 점착 복합방수시트 조인트부의 시공성)

  • Chang, Sang Mook;Kim, Yun Ho;Choi, Sung Min
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Engineers in the construction field have been using bonded waterproofing sheets in an attempt to resolve the imbalance in the quality, the risk of fire, safety of workers, and environmental pollution, as well as to eliminate separate use of organic adhesives on the surface of concrete. Recently, self-laminated waterproofing sheets have been developed. The purpose of this research is to find an appropriate processing speed according to the changes in physical properties, and visual observation of the waterproofing sheets laminated by the aluminum thin-film and viscosity layer that can be attached through self-adhesiveness on the surface of concrete and waterproofing sheets. Therefore, this research is conducted using a physical performance test. Based on the result of the test, when the high-frequency inductive heating apparatus was used, an improved adhesion and bonding stability effect were confirmed after the anti-hydrostatic pressure and bond strength in the temperature condition, and the surface observation in the processing speed condition.

A Case Report of Postpartum Disease Induced by Inadequate Postpartum Care (잘못된 산후관리로 인한 산후질환 1례 보고)

  • Lee, Jin-Moo;Lee, Chang-Hoon;Cho, Jung-Hoon;Jang, Jun-Bock;Lee, Kyung-Sub;Kim, Eun-Sook
    • The Journal of Korean Obstetrics and Gynecology
    • /
    • v.20 no.3
    • /
    • pp.238-245
    • /
    • 2007
  • Purpose: In postpartum period, women are very weak and liable to various diseases. So postpartum care is very important. But excessive heating and sweating cause postpartum diseases. Methods: The patient in this case, 37 years-old female was in Kyunghee University East-West neo medical center for 8days(27th/Oct/2006 - 3rd/Nov/2006). Her chief complains when she was admitted in the hospital were sweating, chilling, and mild dizziness. These symptoms were caused by excessive heating and sweating. We thought that her condition was deficiency of Qi. After giving her the therapies with herb medicine, acupuncture and moxibustion, her symptoms got almost disappeared and her condition got better. Results: After the oriental medical treatment, the clinical symptom of postpartum disease was improved. Conclusion: This case study shows that excessive heating and sweating cause postpartum diseases and the oriental medical therapy is effective in treating postpartum disease. And the guideline of postpartum care is needed.

  • PDF

Power Control Method for FB-SRC IH Cooktop System Considering Limited Switching Frequency Range Condition (가용 동작 주파수 범위를 고려한 FB-SRC 기반 IH 쿡탑 시스템의 전력 제어 방안)

  • Hwang, Yun-Seong;Lee, Joo-Seung;Kang, Seung-Hyun;Kwon, Man-Jae;Jang, Eunsu;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.27 no.3
    • /
    • pp.256-264
    • /
    • 2022
  • The frequency power control method (FCM) which has a wide operating frequency range is adopted for induction heating (IH) cooktops. When FCM is applied to the full-bridge series resonant converter (FB-SRC) based IH system, high-frequency switching of the inverter is required compared to the half-bridge SRC (HB-SRC)-based IH system. Therefore, the switching loss of the inverter increases, and applying FCM under the condition that the inverter operating frequency range is limited is difficult. Therefore, this paper proposes a control strategy with the phase shift power control method considering that limited frequency conditions are presented. Loss analysis following the control method is performed through simulation and mathematical analysis. In addition, the validity of the proposed control strategy is verified by analyzing the heating performance following the control method through the test results of the 3,200[W] prototype.

Experimental Study on Heating Performance by Operation Combination of Heat Pump with 3 Indoor-Units (3실 열펌프의 운전조합에 대한 난방성능 실험연구)

  • Kim, Ju-Hyung;Kim, Ki-Young;Kwon, Young-Chul;Park, Seung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4197-4203
    • /
    • 2013
  • In order to investigate the heating performance of multi-heat pump applying an inverter compressor, the experiment on heat pump with 3 indoor units was performed under the heating standard and heating low-temperature conditions. The performance data of heat pump with 3 indoor units were measured by the multi-psychrometric calorimeter. The operation characteristics and the behavior of the refrigerant cycle of the heat pump with 3 indoor units were understood from the heating capacity, heating COP, and P-h diagram by indoor-unit combination. The present experimental results show that the operating load and performance of the multi-heat pump depends on the indoor-unit combination. The heating capacity and heating COP of the low temperature condition were smaller than those of the standard one. Also the refrigerant cycles on indoor-unit combination were analyzed by using P-h diagram.

An Experimental Study on the Fluidization and Heat Transfer Characteristics in the Gas-Solid Fluidized Bed Furnace (기일고(氣一固) 유동층노내(流動層爐內) 유동화(流動化) 및 전열특성(傳熱特性)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Choi, Gug-Gwang;Park, Jong-Suen
    • Solar Energy
    • /
    • v.9 no.3
    • /
    • pp.55-63
    • /
    • 1989
  • In this paper, the fluidization characteristics of the magnesia fluidized bed and the heat transfer characteristics with the specimen (SM55C) plunged in the bed have been investigated. To characterize the fluidization, the minimum fluidizing velocities and the relation ships between bed voidage and fluidization rate and obtained. To characterize heat transfer, the experiments for finding heating time transfer effect have been carried out by varying the magnesia particles sizes. optimum heating condition in the magnesia fluidized bed is obtained.

  • PDF

An Experimental Study on the Mechanical Behavior of High-Strength Concretes Subjected to High Temperature (고온을 받은 고강도 콘크리트의 역학적 특성에 관한 실험적 연구)

  • Yang, Keun-Hyeok;Hong, Seong-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.05b
    • /
    • pp.25-28
    • /
    • 2005
  • The experimental results on the mechanical behavior of high-strength concretes subjected to high temperature were presented. Main variables were heating temperature, heating continuance time, and cooling condition. The compressive strength properties of high strength concrete(HSC) varied differently with temperature than those of normal strength concrete(NSC). HSC had higher rates of strength loss than NSC in the temperature range of between $20^{circ}C$ and $400^{circ}C$. Especially, HSC exploded in $400^{circ}C$ of high temperature.

  • PDF

Soldering Process of Au Bump using Longitudinal Ultrasonic (종방향 초음파를 이용한 Au 범프의 솔더링 공정)

  • 김정호;이지혜;유중돈;최두선
    • Journal of Welding and Joining
    • /
    • v.22 no.1
    • /
    • pp.65-70
    • /
    • 2004
  • A soldering process with longitudinal ultrasonic is conducted in this work using the Au bump and substrate. Localized heating of the solder is achieved and the stirring action due to the ultrasonic is found to influence the bond strength and microstructure of the eutectic solder The acceptable bonding condition is determined from the tensile strength. Since the multiple bonds can be formed simultaneously with localized heating, the proposed ultrasonic soldering method appears to be applicable to the high-density electronic package.

Effects of Heating on Hydroxyl Radical-Generated Toxicity in Mouse Forebrain Tissue Culture

  • Lee, Jeong-Chae;Lim, Kye-Taek
    • Toxicological Research
    • /
    • v.14 no.3
    • /
    • pp.301-306
    • /
    • 1998
  • This experiment was carrid out to know the effects of heating and serum on hydroxyl radicals in embryonic mouse forebrain (cerebrum) culture. The heating to mouse embryonic cerebrum cells in culture was done in a water bath at 43${\circ}C$ for 60min. After that, two supernatants were prepared at 20 hrs and 48 hrs respectively after heat treatment to the brain cells. To find out the heating effects on neuron cells, mouse cerebrum cells (13 embryonic day) were cultured in hydroxyl radical generation system composed of 20mU/ml glucose oxidase (GO system), using condition of normal culture media (MEM, 5% serum, 5% $CO_2$or supernatant prepared after heating at 43${\circ}C$ for 60 min in a water bath. Supernatant prepared at 20 hrs after heat treatment had a greater protective effects against hydroxyl radical than supernatant prepared at 48 hrs after heat treatment . Otherwise, the protective effect of serum against hydroxyl radicals in the cultured brain cells is higher than that in the heat treatment. These results indicated that serum in culture media reduced cytotoxicity of hydroxyl radicals in mouse forebrain culture, also that heat treatment showed the protective effects against hydroxyl radicals generated with 20mU/ml GO system in mouse forebrain culture.

  • PDF

The Effects of Chicken Leg Bone Extract on Antioxidative Properties under Different Heating Condition

  • Cheng, Fu-Yuan;Wan, Tien-Chun;Huang, Chao-Wei;Tominaga, Kana;Lin, Liang-Chuan;Sakata, Ryoichi
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.21 no.12
    • /
    • pp.1815-1820
    • /
    • 2008
  • The aim of this study was to extract chicken leg bone, which is a by-product of industrial poultry processing, using different heating temperatures (80, 90 and $100^{\circ}C$) and durations (5, 10 and 15 min). The pH value, soluble protein content, peptide content and antioxidative properties, including superoxide anion scavenging ability, 1, 1-diphenyl-2-picrylhydrazyl (DPPH) free radical scavenging ability, reducing capacity and inhibitory activity of linoleic acid peroxidation, were measured. The results showed no significant differences (p>0.05) in pH value among all treatments. Decreased soluble protein content and peptide content were observed in chicken leg bone extract obtained under higher heating temperatures (90 or $100^{\circ}C$) and longer heating durations (10 or 15 min). In antioxidative properties, the extracts which were heated at 90 or $100^{\circ}C$ for 15 min exhibited significantly higher superoxide anion scavenging ability, DPPH free radical scavenging ability, reducing capacity and inhibitory activity of linoleic acid peroxidation (p<0.05).

Heating Performance of a Ground Source Multi-Heat Pump for a Greenhouse (지열원 멀티 열펌프 시스템의 시설원예 적용 난방성능 특성 실증 연구)

  • Kang, Shin-Hyung;Choi, Jong-Min;Moon, Je-Myung;Kwon, Hyung-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.6
    • /
    • pp.337-344
    • /
    • 2010
  • Good plant-growth conditions can be achieved by means of using greenhouses. One of the main issues in greenhouse cultivation is energy savings through the development of high efficient heating and cooling system. GSHPs are one of the recommended systems to cope with this pending need. The aim of this study is to investigate the heating performance of ground source multi-heat pump system installed in a greenhouse under part load conditions. Daily average heating COP of the heat pump unit was very high by at least 7.4, because of relatively large condenser, evaporator, and mass flow rate through ground loop heat exchanger. However, the system COP, overall heating coefficient of the performance of the system with heat pump unit and GLHX, decreased drastically due to relatively large power consumption of circulating pump under part load condition. It is suggested that the technology to enhance the performance of the ground source multi-heat pump system for a greenhouse under part load conditions should be developed.