• Title/Summary/Keyword: Heating Characteristics

Search Result 2,424, Processing Time 0.036 seconds

Component Characteristics of Each Extract Prepared by Different Extract Methods from By-products of Glycyrrhizia uralensis (추출 조건을 달리한 감초부산물 추출물의 성분 특성)

  • 강명화;박춘근;차문석;성낙술;정혜경;이제봉
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.30 no.1
    • /
    • pp.138-142
    • /
    • 2001
  • Solid contents, free sugars, phenlic compounds and glycyrrhizin of extracts obtained from by-products of Glycyrrhizia uralensis by three different methods, i.e., shaking, heating, and static methods, were determined. Solid contents of extracts obtained by shaking, heating and static method were 15.6%, 15.0% and 5.3%, respectively. Phenolic compound contents of them were 11.33 mg/100 mL, 11.21 mg/100mL and 10.15 mg/100 mL. Main free sugars in the extracts from the by-products of G. uralensis were fructose, glucose, sucrose, and maltose. Glycyrrhizin content of the extracts from the by-products of G. uralensis were 2.79%, 3.54% and 0.63%, respectively. Extract obtained by the shaking methods had an ability of donating electron to DPPH. The relative antioxidant effects of th extract obtained from the shaking method showed 70% inhibitory effect of peroxidation on egg yolk lecithin.

  • PDF

Development of Micro Cooling System for Telecommunication System using Oscillating Heat Pipe (진동 세관형 히트파이프를 이용한 통신 기기용 마이크로 냉각시스템의 개발)

  • Ha, Soo-Jung;Bae, Nae-Soo;Park, Chul-Min;Kim, Jung-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1499-1505
    • /
    • 2003
  • Rapid development of electronic technology requires small size, high density packaging and high power of electronic devices. So, in this paper, characteristics on oscillating heat pipe according to operating conditions(environment temperature, charging ratio of working fluid, inclination) based on experimental study was investigated. From the experimental results, $25^{\circ}C$environment temperature), R-141b(working fluid)40%(charging ratio) was best performace at others of inclination angle and The top heating mode of OCHP performed 80% efficiency of the bottom heating mode.

  • PDF

Temperature Distribution of a Low Temperature Heat Pipe with Multiple Heaters for Electronic Cooling

  • Noh, Hong-Koo;Song, Kyu-Sub
    • ETRI Journal
    • /
    • v.20 no.4
    • /
    • pp.380-394
    • /
    • 1998
  • A numerical study has been performed to predict the characteristics on the transient operation of the heat pipe with multiple heaters for electronic cooling. The model of the heat pipe was composed of the evaporator section with four heaters, insulated transport section, and the condensor section with a conductor which is cooled with uniform heat flux condition to surrounding. The governing equations and the boundary conditions were solved by the generalized PHOENICS computational code employing the finite volume method. Two test cases are investigated in present study; Case 1 indicates that the 1st and 2nd heaters among four heating sources are heated off, while the 3rd and 4th heaters are heated on. Case 2 is the inverse situation switched from heating location of Case 1. The results show that the transient time to reach the steady state is shorter for Case 1 than for Case 2. Especially, the temperature difference of the heater during switching operation is relatively small compared to the maximum allowable operating temperature difference in electronic system. Hence, it is predicted that the heat pipe in present study operates with thermally good reliability even for switching the heaters.

  • PDF

A Study on Performance Characteristics of Heat Exchanger for Heat Pump with R410A Refrigerant (R410A 냉매를 사용한 열펌프용 열교환기의 형상에 따른 성능특성 연구)

  • 정규하;박윤철;오상경
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.340-348
    • /
    • 2004
  • The air and refrigerant side heat transfer performances are key parameters to improve heat transfer efficiency of the heat exchanger including the fan performance. Design of the fins, treatment of the tube inside, tube diameter and tube array effect heat transfer performance of the heat exchanger. The heat exchanger is used as a condenser at cooling mode and used as an evaporator at heating mode in the heat pump system. The heat pump system uses R410A as the refrigerant. The heat exchangers are consisted with 7 mm diameter tubes with slit-type fins. The study was conducted with variation of arrangement of the refrigerant path and air flow rate and refrigerant pressure drop and heat transfer rate were measured with a code tester. The capacity of the 3 path heat exchanger is more efficient than 2 or 4 path heat exchangers in heating or cooling modes.

Long term drag reduction experiments of surfactant solutions in a pilot-scaled system (Pilot규모에서 계면활성제용액의 장기 마찰저항감소에 관한 연구)

  • Park, S.R.;Lee, S.N.;Moon, S.H.;Yoon, H.K.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.9 no.3
    • /
    • pp.401-409
    • /
    • 1997
  • The long term drag reduction characteristics of Habon-G solution were investigated in the KIER pilot-scaled district heating simulation system. Test runs were implemented for 30 days without interruption. Pressure drop, flow rate and power consumption of surfactant (Habon-G) solution were regularly observed and compared with those of plain water. The experimental results suggest that the surfactant can be effectively applied to the DH transmission system for considerably long period wthout significant loss of its drag reduction capability even though the concentration of the additive may gradually decrease in the first stage of the experiment because of absorption.

  • PDF

A Study on Characteristics of PV Generation System in the Southwest Seaside Island (서남해안 도서지역 태양광 발전소의 발전 특성)

  • Moon, Chae-Joo;Jin, Ou-Sam;Jung, Sang-Weon;Kwak, Wang-Shin;Song, Sung-Geun;Kim, Eui-Sun
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1116-1117
    • /
    • 2008
  • 본 연구는 서남 해안의 섬 지역에 설치된 태양광 발전소의 발전 특성을 측정하고 분석한 것이다. 발전소의 총 발전 용량은 806.4kWp 이고 고정식과 추적식이 복합적으로 시설되어 있다. 일사량을 측정하고 인버터의 효율을 분석하였으며 전력 계통을 분석하였다. 인버터의 측정 및 분석결과 인버터는 효율이 평균 94.5%였고, 전력 계통의 분석은 파형 분석과 상 불평형 분석, 고조파 분석을 실시하였다. 주파수 분석결과 전압은 THD가 2%, 전류는 1.5%로 양호하게 나타남을 확인하였다.

  • PDF

A Study on the Temperature Control System Design of Heat Pipe for Alternative Heating (대체 난방용 히트파이프 온도 제어 시스템 설계에 관한 연구)

  • Yoon S.A.;Shu J.S.;Cho K.J.;Cha I.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.908-912
    • /
    • 2003
  • The waste heat recovery system using heat pipe was tested for the consideration of developing the high-efficiency waste heat recovery technology. Heat pipe, a effective device that can quickly transfer large amounts of heat energy using the phase change of the working fluid and the characteristics of Electric Heater Bars used for alternative heating system are introduced In this paper. In order to increase energy efficiency, the system which controls the status of electric heater bars and the temperature of heat pipe installed has developed.

  • PDF

Comparative Analysis of the Parabolic and Hyperbolic Heat Conduction and the Damped Wave in a Finite Medium (유한한 평판에서 포물선형 및 쌍곡선형 열전도 방정식과 파동 방정식의 비교 해석)

  • Park, S.K.;Lee, Y.H.
    • Journal of Power System Engineering
    • /
    • v.3 no.3
    • /
    • pp.14-21
    • /
    • 1999
  • The wave nature of heat conduction has been developed in situations involving extreme thermal gradients, very short times, or temperatures near absolute zero. Under the excitation of a periodic surface heating in a finite medium, the hyperbolic and parabolic heat conduction equations and the damped wave equations in heat flux are presented for comparative analysis by using the Green's function with the integral transform technique. The Kummer transformation is also utilized to accelerate the rate of convergence of these solutions. On the other hand, the temperature distributions are obtained through integration of the energy conservation law with respect to time. For hyperbolic heat conduction, the heat flux distribution does not exist throughout all the region in a finite medium within the range of very short times(${\xi}<{\eta}_l$). It is shown that due to the thermal relaxation time, the hyperbolic heat conduction equation has thermal wave characteristics as the damped wave equation has wave nature.

  • PDF

A Study of Heat Transfer Phenomena in a Sensor Tube of a Mass Flow Controller (질량흐름 제어기의 센서 튜브에서 열전달현상에 관한 연구)

  • Lee, S.K.;Kim, Y.S.
    • Journal of Power System Engineering
    • /
    • v.7 no.3
    • /
    • pp.35-39
    • /
    • 2003
  • In this paper, the heat transfer phenomena in the sensor tube of a mass flow controller(MFC) were studied by experiments. In the sensor tube of MFC, the difference of temperature between inlet and outlet was necessary for calculating the mass flow rate. Therefore, the relations of flow rate, generated heat by heating wire, sensor location and tube thickness were investigated to find the optimized condition. Based on this study, static and dynamic characteristics of sensor can be used for mass flow controller.

  • PDF

An Experimental Study on the Defect Detection for the Steam Heating Drum Journal (증기 가열 드럼 저널부의 결함 검출에 대한 실험적 연구)

  • Suh, Nam-kyu;Chang, Tae-Hyun;Lee, Jae-do
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.7 no.1
    • /
    • pp.69-82
    • /
    • 2004
  • Recently, in the food, paper, steel and plastic industries, plate or sheet type products have been produced by the rolling drum. Steam heating drums are introduced into plastic products facilities in order to keep the density, microstructure, and strength of material uniformly. The drum journal can not help being concentrated by stresses due to the bending and torsion. Especially the drum, heated by high pressure steam, might be exposed in the steam leakage accident. First of all, the stresses on the steam drum journal are to be analyzed, and a case study proper to the subject was performed with a scraped journal, in order to investigate the failure characteristics as well as the initiation and propagation of fatigue cracks, and most probable circumstances of crack initiation. As the result of this study, it is suggested that newly installed drum journal be thoroughly inspected at the next periodic maintenance intervals for evidence of cracking, the microstructure examination and hardness measurements to prevent steam drum from the failure accident.

  • PDF