• Title/Summary/Keyword: Heating Characteristics

Search Result 2,423, Processing Time 0.03 seconds

DEVELOPMENT OF HYPER INTERFACIAL BONDING TECHNIQUE FOR ULTRA-FONE GRAINED STEELS

  • Kazutoshi Nishimoto;Kazuyoshi Saida;Jeong, Bo-young;Kohriyama, Shin-ichi
    • Proceedings of the KWS Conference
    • /
    • 2002.10a
    • /
    • pp.776-780
    • /
    • 2002
  • This paper describes the concept and the characteristics of hyper interfacial bonding developed as a new concept joining process for UFG (ultra-fine grained) steel. Hyper interfacial bonding process is characterized by instantaneous surface melting bonding which involves a series of steps, namely, surface heating by high frequency induction, the rapid removing of heating coil and joining by pressing specimens. UFG steels used in this study have the average grain size of 1.25 ${\mu}{\textrm}{m}$. The surface of specimen can be rapidly heated up and melted within 0.2s. Temperature gradient near heated surface is relatively steep, and peak temperature drastically fell down to about 1100K at the depth of 2~3mm away from the heated surface of specimen. Bainite is observed near bond interface, and also M-A (martensite-austenite) islands are observed in HAZ. Grain size increases with increasing heating power, however, the grain size in bonded zone can be restrained under 11 ${\mu}{\textrm}{m}$. Hardened zone is limited to near bond interface, and the maximum hardness is Hv350~Hv390.

  • PDF

Experimental Study on the Performance Characteristics of a Simultaneous Heating and Cooling Heat Pump System at Each Operating Mode (동시냉난방 열펌프 시스템의 운전모드별 성능특성에 관한 실험적 연구)

  • Kang, Hoon;Lee, Sun-Il;Joo, Young-Ju;Chung, Hyun-Joon;Kim, Yong-Chan;Choi, Jong-Min
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.10
    • /
    • pp.679-686
    • /
    • 2007
  • The cooling load in winter season is significant in many commercial buildings and hotels because of the usage of office equipments and the high efficiency of wall insulation. The development of a multi-heat pump that can cover heating and cooling simultaneously for each indoor unit is required. In this study, a 4-room simultaneous heating and cooling heat pump system was designed and its performance was measured at each operating mode. The system used R-410A and adopted variable speed compressor. The problems on the designed system were analyzed and defined. In addition, the solutions of the problems were suggested to improve system efficiency and to obtain the stable operation.

Heating and Cooling Performance Characteristics of a Water-to-Water Heat Pump with R452B Refrigerant (R452B 냉매 적용 물대물 지열원 히트펌프 유닛의 냉난방 운전 성능 특성)

  • Choi, Youn Sung;Kang, Hee Jeong;Kim, Eun Oh
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.13 no.4
    • /
    • pp.14-20
    • /
    • 2017
  • Refrigerant having high global warming potentials will be phased out due to environmental protection issues. R410A has been widely used in geothermal heat pump. However, it has a little high GWP by 2088 value. One of the recommended substitute for R410A refrigerant is R452B which having a GWP by 698 value. In this paper, the heating and cooling performance of the water-to-water geothermal heat pump unit with R452B was experimentally investigated. The performance of the heat pump adopting R452B was also compared with the system applying R410A. The heating and cooling capacity of R452B heat pump system showed a slightly lower values within 2% comparing with R410A system. However, the R452B system's coefficient of performance was enhanced by 5.2% and 13.7% at heating and cooling mode, respectively.

Field Measurements and CFD Simulations of Indoor Thermal Environments in the Assembly Hall (대형 강의실의 실내 열환경 실측 및 컴퓨터시뮬레이션 비교 연구)

  • Yoon, JaeOck
    • KIEAE Journal
    • /
    • v.4 no.3
    • /
    • pp.179-186
    • /
    • 2004
  • The evaluation of the indoor environment of the Assembly Hall in the University, which is designed to be a large space, requires efficient design of its heating system that takes into consideration natural convection and the characteristics of the occupant's spaces. Indoor thermal environment was measured in the field and simulated with CFD code. The estimations of temperature distribution and indoor airflow distribution must be carried out simultaneously, as the thermal stratification is induced by natural convection flows. In order to simulate the even distribution of factors affecting the indoor environment, including temperature and airflow, Phoenics is used. The turbulent flow model adopted is the RNG k- model. The inlets and outlets of the air-conditioning systems, material and thermal properties, and the size of the test room ($35m{\times}18m{\times}10m$) are used for the simulation. Since the Assembly Hall is symmetric, half of the space is simulated. A Cartesian grid is used for calculation and the number of grids are respectively $60{\times}45{\times}35$. The results of the computer simulation during winter conditions are compared with the measurements at the typical points in the assembly hall with the heating system. After evaluating the results of the computer simulations, the methods of the heating system and layout are suggested.

Influence of Heating Rate and Temperature on Carbon Structure and Porosity of Activated Carbon Spheres from Resole-type Phenolic Beads

  • Singh, Arjun;Lal, Darshan
    • Carbon letters
    • /
    • v.10 no.3
    • /
    • pp.181-189
    • /
    • 2009
  • Activated carbon spheres (ACS) were prepared at different heating rates by carbonization of the resole-type phenolic beads (PB) at $950^{\circ}C$ in $N_2$ atmosphere followed by activation of the resultant char at different temperatures for 5 h in $CO_2$ atmosphere. Influence of heating rate on porosity and temperature on carbon structure and porosity of ACS were investigated. Effect of heating rate and temperature on porosity of ACS was also studied from adsorption isotherms of nitrogen at 77 K using BET method. The results revealed that ACS have exhibited a BET surface area and pore volume greater than $2260\;m^2/g$ and $1.63\;cm^3/g$ respectively. The structural characteristics variation of ACS with different temperature was studied using Raman spectroscopy. The results exhibited that amount of disorganized carbon affects both the pore structure and adsorption properties of ACS. ACS were also evaluated for structural information using Fourier Transform Infrared (FTIR) Spectroscopy. ACS were evaluated for chemical composition using CHNS analysis. The ACS prepared different temperatures became more carbonaceous material compared to carbonized material. ACS have possessed well-developed pores structure which were verified by Scanning Electron Microscopy (SEM). SEM micrographs also exhibited that ACS have possessed well-developed micro- and meso-pores structure and the pore size of ACS increased with increasing activation temperature.

The Relationship between Energy Consumption and Factors Affecting Heating and Cooling

  • Park, Kwon Sook;Kim, Seiyong
    • Architectural research
    • /
    • v.19 no.1
    • /
    • pp.7-11
    • /
    • 2017
  • Energy consumption in university building has steadily increased over the last decade, and a strong upward trend in recent years. This study was undertaken to analyze the relationship between energy consumption and their affecting factors, six academic buildings were considered. The factors limited to heating and cooling, which is the main end use (nearly 60 per cent of total energy consumption in university buildings), encompassing system and operating schedules (user activity) and area use. To understand how to building is used, operated and managed, walk-through assessment was conducted as well as interview with university staff. The results show that the energy consumption of the humanities building was somewhat smaller than the consumption of the science and engineering building, and its range was from $31.26kgoe/m^2$ to $23.52kgoe/m^2$, depending on heating and cooling system and area use. And the energy consumption of the science and engineering building was related to operating schedules (user activity) as well as laboratory equipment characteristics. More analysis on a larger number of buildings is required in the future, including building form and material performance level to generalize the significant factors influencing building energy consumption.

Study on applicability of RDF in Municipal Waste Landfill Site (생활폐기물매립장에서의 RDF 적응가능성에 대한 연구)

  • Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.18 no.10
    • /
    • pp.1181-1187
    • /
    • 2009
  • Results for application of RDF(Refuse Derived Fuel) to selected wastes in metropolitan and small and medium cities are as follows. The physical characteristics of waste are paper, plastic, food waste, and so on. The proximate analysis in P city showed 20.2% of moisture, 71% of combustible material, and 8.8% of ash on annual average. That in G city showed 31.6% of moisture, 59.5% of combustible material, and 8.9% of ash. Ultimate analysis in P city showed 52.04% of carbon, 7.02% of hydrogen, 28.80% of oxygen, 0.66% of nitrogen, and 0.09% of sulfur. Heating value was 3,363 kcal/kg. Ultimate analysis in G city showed 50.85% of carbon, 6.56% of hydrogen, 29.86% of oxygen, 0.79% of nitrogen, and 0.12% of sulfur. Heating value in the G city was somewhat lower than that in the P city with 2,632 kcal/kg. Thus, application of RDF in metropolitan city was more effective than that in small and medium cities. Heating value in mixture for the P city was lower than that in waste of the volume rate waste charge system alone by 143 kcal/kg. In proximate analysis, moisture, and combustible material were likely to be more adequate to RDF.

EFFECT OF HEAT TREATMENT ON NUTRITIONAL VALUE OF WINGED BEAN (Psophocarpus tetragonolobus) AS COMPARED TO SOYBEAN I. CHEMICAL CHARACTERISTICS OF TREATED WINGED BEAN

  • Mutia, R.;Uchida, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.6 no.1
    • /
    • pp.19-26
    • /
    • 1993
  • The effect heat treatment (autoclave) on nutritional value of winged bean as compared to soybean has been investigated. The winged bean and soybean were obtained from local cultivar grown in Indonesia. The beans were autoclaved at $120^{\circ}C$ for 15, 30, 45, 60 or 90 minutes, respectively before being ground for chemical analysis. Trypsin inhibitors of winged bean and soybean decreased (p < 0.05) along with decreasing of urease activity as heating time increased from 0 to 90 minutes. Heat treatment significantly (p < 0.05) reduced protein solubility in 0.2% potassium hydroxide of winged bean as well as soybean. In vitro protein digestibility was significantly (p < 0.05) improved by heating treatment (15 to 60 min of autoclaving), however, excessive heating (90 min of autoclaving) decreased the digestibility of winged beans. Excessive heating had adverse effect on lysine, cystine and methionine contents of winged beans. The results of this study suggested that autoclaving at $120^{\circ}C$ within 45 minutes should be adequate to remove protease inhibitors and could improve protein digestibility of winged beans.

Drying Characteristics of Plating Sludge by Microwave (마이크로파 가열에 의한 도금슬러지 건조특성)

  • 문경환;손종렬;김덕찬
    • Journal of environmental and Sanitary engineering
    • /
    • v.13 no.1
    • /
    • pp.9-15
    • /
    • 1998
  • Microwave heating and drying processes have been well established in various industrial applications. Feasibilities of successful application of microwave drying to many material have been shown on the laboratory or pilot-plant scale. The microwave drying behavior of plating sludge are considered in this paper. The plating sludge containing 70%, 80% and 90% water exposed to microwave power at 2,450 MHz, 700W. An experimental microwave drying apparatus was designed and constructed to monitor weight loss during drying. By studying the drying characteristic curve, the moisture in sludge was almost classified into two categories : free moisture and intestinal moisture. And the critical moisture contents at which the drying rate ceases to be constant were from 10.1 to 10.5%. A simple drying model is proposed which may be used to describe drying behavior of plating sludge. The constant rate and the falling rate periods in microwave drying were addressed separately. From the eqation of constant rate period the drying rate constants decreased exponentially with increasing depth. Microwave heating compared with conventional heating offered higher heating rates from 9 to 16 times. Therefore, microwave drying process can be effective in removing moisture from plating sludge.

  • PDF

Characteristics of Drawing and Concurrent Spot Welding of Overlapped Aluminum Plates with Copper Electrodes Inserted in Heated Dies (가열된 금형에 삽입된 구리전극에 의한 중첩된 알루미늄 합금판재의 드로잉성형 동시 점용접 특성)

  • Kim, T.H.;Jin, I.T.
    • Transactions of Materials Processing
    • /
    • v.26 no.3
    • /
    • pp.174-180
    • /
    • 2017
  • In this study, a new spot welding with electric resistance heated dies is suggested for the spot welding of non-ferrous metal plates for drawing and concurrent spot welding. This welding method involves two heating processes such as heating by conduction of electric resistance heated dies and heating by resistance between contacted surfaces of two plates by welding current induced to copper dies for the fusion of contacted metal. This welding process has welding variables such as current induced in heated and copper dies, the inner diameters of heated dies, and edge shape of the copper dies. Experimental conditions for each current should be established to get successful welding strength. The welding strength could reach to the desired value in industrial fields under the following conditions of contact diameters of heated dies in this case of overlapped aluminum5052 plates with 0.3-mm thickness: inner and outer diameters of 5.0 and 16mm, respectively; diameter of copper dies, 5.0mm; heating current, 6.8kA in heated steel dies; welding current, 8.6 kA in copper dies.