• Title/Summary/Keyword: Heating Characteristics

Search Result 2,423, Processing Time 0.037 seconds

Cooling and Heating Performance Evaluation of a Ground Source Heat Pump (지열원 열펌프의 냉.난방 성능 평가)

  • Sohn, Byong-Hu;Cho, Chung-Sik;Shin, Hyun-Joon;An, Hyung-Jun
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2117-2122
    • /
    • 2004
  • The main objective of the present study is to investigate the performance characteristics of a ground source heat pump (GSHP) system with a 130 m vertical 60.5 mm nominal diameter U-bend ground heat exchanger. In order to evaluate the performance analysis, the GSHP system connected to a test room with 90 $m^2$ floor area in the Korea Institute of Construction Technology ($37^{\circ}39'$ N, $126^{\circ}48'$ E) was designed and constructed. This GSHP system mainly consisted of ground heat exchanger, indoor heat pump and measuring devices. The cooling and heating loads of the test room were 5.5 and 7.2 kW at design conditions, respectively. The experimental results were obtained from July to January in cooling and heating season of $2003{\sim}2004$. The cooling and heating performance coefficients of the system were determined from the experimental results. The average cooling and heating COPs for the system were obtained to be 4.82 and 3.02, respectively. The temperature variations in ground and the ground heat exchanger surface at different depths were also measured.

  • PDF

Performance Analysis of the Horizontal Ground Source Heat Pump for Greenhouse (시설원예용 수평형 지열 히트펌프 시스템의 성능분석)

  • Park, Yong-Jung;Kang, Shin-Hyung
    • Proceedings of the SAREK Conference
    • /
    • 2007.11a
    • /
    • pp.447-452
    • /
    • 2007
  • Greenhouses should be heated during nights and cold days in order to fit growth conditions in greenhouses. Ground source heat pump(GSHP) or geothermal heat pump system(GHPs) is recognized to be outstanding heating and cooling system. Horizontal GSHP system is typically less expensive than vertical GSHP system but requires wide ground area to bury ground heat exchanger(GHE). In this study, a horizontal GSHP system with thermal storage tank was installed in greenhouse and investigated as performance characteristics. In the daytime, heating load of greenhouse is very small or needless because solar radiation increases inner air temperature. The results of study showed that the heating coefficient of performance of the heat pump ($COP_h$) was 2.9 and the overall heating coefficient of performance of the system($COP_{sys}$) was 2.4. Heating energy cost was saved 76% using the horizontal GSHP system with thermal storage tank.

  • PDF

A Study on the Thermal Analysis of Induction Hooting Cooker with Finite Element Method (유한요소법에 의한 IH-Cooker의 열해석에 관한 연구)

  • Oh, Hong-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.17 no.1
    • /
    • pp.80-85
    • /
    • 2003
  • Recently, induction heating cooker(IH-Cooker) is very interested for high efficiency, the quickness of heating time and the convenient regulation of heating spot. In this paper, we proposed the magneto-thermal analysis of an induction heating cooker(IH-Cooker) as an efficient design, and analyzed the magnetic fold intensity inside the axisymmetric shaped cooker using three-dimensional axisymmetric finite element method(Flux2D) and the effectual heat source was obtained by ohmic losses from eddy currents induced in the cooker. Also, we presented the temperature characteristics of the IH-Cooker according to input frequency and relative permeability in stainless parts and in aluminum parts.

Study on the Performance of Heat Pump Using Non-azeotropic Refrigerant Mixtures R-22+R-114 (비공비혼합냉매 R-22+R-114를 이용한 열펌프의 성능에 관한 연구)

  • 박기원;구학근;오후규
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2131-2137
    • /
    • 1993
  • This study, examines the performance and the heat pump cycle systematizing characteristics for non-azeotropic refrigerant systems. In order to conduct such an examination, the cycle characteristics of heat pumps for pure R-22, R-114, and their mixtures were experimentally investigated. The results show that cooling/heating capacities for the mixtures was more suited at the evaporating temperature of $5^{\circ}C$ than that of $0^{\circ}C$, $-5^{\circ}C$, and $-10^{\circ}C$. The C.O.P of the 50 wt% mixtures was considerably higher than for pure R-22, and the compression power of the 25 wt% was as much as 60% lower than that of pure R-22. Even small fractional mixture variations can lead to significant changes in the characteristics of the heat pump cycle. This experiment verified the importance of accurate weight fractions of refrigerant mixtures.

Control of Pore Characteristics of Porous Glass in the $ZrO_2.SiO_2$ System Prepared by the Sol-Gel Method (졸-겔법으로 제조한 $ZrO_2.SiO_2$다공질유리의 세공제어)

  • 신대용;한상목
    • Journal of the Korean Ceramic Society
    • /
    • v.30 no.6
    • /
    • pp.485-491
    • /
    • 1993
  • Porous glass in the ZrO2.SiO2 system containning up to 30mol% zirconia were prepared by the sol-gel method from metal alkoxides and their pore characteristics with reaction parameters were investigated. The gels were made by hydrolyzing and condensation of the mixed metla alkoxides and were converted into the porous glass by heating up to $700^{\circ}C$. As a results, the mean pore radius became larger with increasing contents of HCl, H2O and hydrolysis temperature, and an alcohol with a large molecular weight for making the porous glass. In the case of 20ZrO2.80SiO2 porous glass with heated at $700^{\circ}C$, HCl and H2O content was 0.3mol and 4mol, the specific surface area was 284$m^2$/g, average mean pore radius was about 19.4$\AA$, porosity was 22.55% and pore characteristics depended on heating temperature.

  • PDF

A Study on Electro-Optical Characteristics of the TN Cell Photoaligned on the Ν-(phenyl)maleimide Surface using the UVLPH Photodimerization Method (Ν-(phenyl)maleimide 표면에 UVLPH 광중합법을 이용한 광배향 TN 셀의 전기광학특성에 관한 연구)

  • 황정연;김준영;김태호;서대식;김영식
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.15 no.8
    • /
    • pp.731-735
    • /
    • 2002
  • Electro-optical (EO) performances for the twisted-nematic (TN)-liquid crystal display (LCD) photoaligned with linearly polarized UV exposure on the poly[4- (fluorocinnamate) phenylmaleimide](PFCPMI) surfaces using a new photodimerization method were investigated. For a new UVLPH (UV linearly polarized during heating) photodimerization method, the photopolymer layers were exposed by linearly polarized UV dichroic polarizer without a specific UV filter during heating at $150^{\circ}C$. The Voltage-transmittance (V-T) curve without backflow bounce in the photoaligned TN-LCD with UV exposure on the PFCPMI surface for 10 min using the UVLPH photodimerization method was observed. For response time measurement, the transmittance characteristics of the photoaligned TN-LCD using the UVLPH photodimerization method on the photopolymer surface was better than that of the photoaligned TN-LCD using the UVLP photodimerization method under a room temperature.

Eating Qualities of Frozen Cooked Rice on the Thawing Condition (해동조건에 따른 냉동밥의 밥맛 비교)

  • 오명숙
    • Journal of the Korean Home Economics Association
    • /
    • v.35 no.2
    • /
    • pp.147-157
    • /
    • 1997
  • It attempted to determine the effect of various thawing methods, such as pressure cooking, conventional cooking, microwave heating and thawing at room temperature, on the quality of frozen cooked rice using Nongan variety of rice. These effects were analysed at three different periods-after 10 days, 30 days and 90 days. It conducted a physico-chemical analysis(moisture content, dehydration rates, color value and texture) and sensory evaluation o the frozen-thawed cooked rice. The study showed that there were no significant differences on the frozen-thawed cooked rice. The study showed that there were no significant differences on the quality characteristics of frozen-thawed cooked rice during the storage of 90 days. However, the thawing method of pressure cooking caused high moisture content and decrease in hardness on the cooked rice, the desirability for the rice didn't diminish compared with the cooked rice just after cooking. the quality characteristics of the cooked rice after frozen-thawing by conventional cooking and microwave heating were similar with that of the cooked rice just after cooking. thawing at room temperature caused a significant decrease in quality characteristics.

  • PDF

Characteristics analysis of time sharing type high frequencyinverter using serial-parallel resonant (직.병렬공진을 이용한 시분할형고주파 인버터의 특성해석)

  • 조규판;이경호;노채균;배영호;심광렬
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.173-178
    • /
    • 2000
  • The time sharing type high frequency inverter using serial-parallel resonant to give VVVF function in the inverter used as power source of induction heating at high frequency is presented in this paper. This proposed inverter can reduce distribution of the switching current because of using the current of serial resonant circuit to the input current of the parallel one. The analysis of the proposed circuit is generally described by using the normalized parameters. Also, according to the calculated characteristics value, a method of the circuit design and operating characteristics of the inverter is proposed. In addition, this paper proves the validity of theoretical analysis through Simulation. This proposed inverter show that it can be practically used in future as power source system for induction heating application, DC-DC converter etc.

  • PDF

A Case Study on The Reduction and Examination for Noise and Vibration of Backpass Heat Surface in the Power Plant Boiler (발전용 보일러의 후부 전열면 소음진동 저감에 관한 사례 연구)

  • Lee, Gyoung-Soon;Lee, Tae-Hoon;Moon, Seung-Jae;Lee, Jae-Heon
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.642-647
    • /
    • 2008
  • The boiler structure is determined by combustion characteristics and construction costs in the combustion chamber of a large commercial boiler. The heat transfer in boiler is composed of the radiation and the convection. The convective heat transfer has happened to back-pass heating surface. The combustion gas sequentially passes through the reheater tube, 1st economizer tube, and 2nd economizer tube. In case of being lowered in boiler height, we have to install additional tube bundle in back-pass heating surface for increasing the heat transfer of boiler, which causes the noise and vibration from combustion gas. When the combustion gas passes through the back-pass tube bundle in specified load of commercial boiler, this paper analyzes the acoustic characteristics between vortex-shedding frequency and natural frequency in tube bundle cavity. The case study reduce the resonance by changing natural frequency characteristics of tube-bundle cavity using a way to install ant-noise baffle in the direction of combustion gas flow.

  • PDF

공동주책의 에너지소비와 이산화탄소 배출특성

  • 이윤규;이강희
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.9
    • /
    • pp.868-877
    • /
    • 2001
  • This study is to present the typical energy consumption criteria and $CO_2$ exhaust rate in multi-family housing complex by analyzing the energy consumption characteristics. The contents and methodology of this study are as follows; -Examining the documents of maintenance accounts, investigate the cost and its items expended by the annual maintenance in multi-family housing complex. -Survey each consumption of energy sources, maintenance area, location of multi-family housing complex, heating type, and so forth. -After classifying with heating type of multi-family housing complex investigated, Scrutinize the energy consumption by each source. -Analyze the characteristics of energy consumption and $CO_2$ exhaust through multiple regression analyses of maintenance property. -Suggest the typical energy consumption criteria (Mcal/$m^2$.year, Mcal/house.year) and $CO_2$ exhaust rate (kg-c/$m^2$.year, Kg-c/house.year) in multi-family housing complex. the results will come into basic data for estimating energy consumption in multi-family housing complex according to maintenance characteristics.

  • PDF