• 제목/요약/키워드: Heater plate

검색결과 114건 처리시간 0.031초

Development of Induction Heater Hot Water System using New Active Clamping Quasi Resonant ZVS PWM Inverter

  • Kwon, Soon-Kurl;Mun, Sang-Pil
    • 조명전기설비학회논문지
    • /
    • 제22권11호
    • /
    • pp.23-29
    • /
    • 2008
  • This paper presents a new conceptual electromagnetic induction eddy current based stainless steel plate spiral type heater for heat exchanger or dual packs heater in hot water system boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, an active clamping quasi-resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle of zero voltage soft commutation with PWM is developed and demonstrated for a high efficient induction heated hot water system and boiler in the consumer power applications. This consumer induction heater power appliance using active clamping soft switching PWM high frequency inverter is evaluated and discussed on the basis of experimental results.

Numerical Analysis of Vertical Plate Absorber for Optimal Design

  • Yoon, Jung-In;Moon, Choon-Geun;Phan, Thanh-Tong
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제28권2호
    • /
    • pp.252-262
    • /
    • 2004
  • A model of simultaneous heat and mass transfer process in absorption of refrigerant vapor into a lithium bromide solution of water-cooled vertical plate absorber. which was considered to the change of refrigerant vapor pressure along the plate width direction. was developed to evaluate the compactness of plate absorber and supply basis data for optimal design of plate absorber. The effects of plate interval as well as the effect of capacity for one piece of plate absorber on plate absorber size such as plate height. plate heating area and plate absorber volume have been investigated. It is confirmed that there is exist an optimal plate interval minimizing plate absorber volume. And the smaller capacity for one piece of plate absorber. the smaller plate absorber volume is obtained.

지적복합재료를 이용한 온라인 모니터링시스템 개발 (Development of On-Line Monitoring System using Smart material)

  • 이진경;박영철;이상필;박이현
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 춘계학술대회
    • /
    • pp.67-71
    • /
    • 2003
  • A hot press method was used to create the optimal fabrication condition for a Shape Memory Alloy(SMA) composite. The bonding strength between the matrix and the reinforcement within the SMA composite by the hot press method was more increased by cold rolling. In this study, the objective was to develop an on-line monitoring system in order to prevent the crack initiation and propagation by shape memory effect in SMA composite. Shape memory effect was used to prevent the SMA composite from crack propagation. For this system an optimal AE parameter should be determined according to the degree of damage and crack initiation. When the SMA composite was heated by the plate heater attached at the composite, the propagating cracks could be controlled by the compressive force of SMA.

  • PDF

수소가스 감지용 가연성 가스센서 제작을 위한 요소기술 개발 (Development of Core Technologies for Integrating Combustible Hydrogen Gas Sensor)

  • 윤의중;박형식;이석태;박노경
    • 한국전기전자재료학회논문지
    • /
    • 제20권3호
    • /
    • pp.228-233
    • /
    • 2007
  • Core technologies for integrating hydrogen gas sensor were investigated. In this study, the thermally isolated micro-hot-plate with areas of $100{\times}100-260{\times}260{\mu}m^2$ was fabricated by utilizing surface micromachining technique that provides better manufacturing yield than bulk micromachining counterpart. The optimum design of the sensor was peformed by analyzing the thermal profile of the structure obtained from a ANSYS simulator. The 400-nm-thick polysilicon films doped with phosphorus, the 300-nm-thick aluminum films, and the 200-nm-thick $SnO_2$(or ZnO)films were used as the micro-heater material, the temperature sensor material, and the gas sensitive material, respectively. The experimental results show that the developed gas sensors can detect $H_2$ concentration as low as 1 ppm.

Effect of Inclination Angle and Size of Heated Surface on Pool Boiling CHF

  • Yang, Soo-Hyung;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1999년도 춘계학술발표회요약집
    • /
    • pp.155-155
    • /
    • 1999
  • Pool boiling critical heat flux (CHF) have been investigated using plate type test sections with different widths (3 cm & 4 cm) and lengths (10 cm, IS cm & 20 cm) under various incli- nation angles. As the inclination angle increases from $0^{\circ}$ (horizontally facing downward plate) to $30^{\circ}$, CHF sharply increases. After that angle, CHF gradually increases with the increase of the inclination angle. There must be a transition angle between $0^{\circ}$ and $30^{\circ}$, at which the CHF increase rate remarkably changes. According to the comparison of present and previous ex- periments, the transition angle may be affected by heater size and increase with the increase of heater size. The size effect of heated surface on CHF is noticeable in the L15 & L20 series and W4 series; however, it seems to be difficult to find the size effect in L10 series and W3 series.

  • PDF

Effect of a vertical guide plate on the wind loading of an inclined flat plate

  • Chung, Kung-Ming;Chou, Chin-Cheng;Chang, Keh-Chin;Chen, Yi-Jun
    • Wind and Structures
    • /
    • 제17권5호
    • /
    • pp.537-552
    • /
    • 2013
  • Wind tunnel experiments were performed to study the wind loads on an inclined flat plate with and without a guide plate. Highly turbulent flow, which corresponded to free-stream turbulence intensity on the flat roof of low-rise buildings, was produced by a turbulence generation grid at the inlet of the test section. The test model could represent a typical solar collector panel of a solar water heater. There are up-stream movements of the separation bubble and side-edge vortices, more intense fluctuating pressure and a higher bending moment in the turbulent flow. A guide plate would result in higher lift coefficient, particularly with an increased projected area ratio of a guide plate to an inclined flat plate. The value of lift coefficient is considerably lower with increased free-stream turbulent intensity.

고자장, 저온 환경의 UHV surface magneto-optical Kerr effect 장비 구축 및 Fe/Cr(001)계의 자성특성 연구

  • 박용성;오용록;홍지상;김원동;황찬용
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2009년도 제38회 동계학술대회 초록집
    • /
    • pp.400-400
    • /
    • 2010
  • 우리는 기본 진공 $10^{-11}\;Torr$의 UHV surface magneto-optical Kerr effect (SMOKE) 시스템을 quarter-wave plate를 사용하였던 기존의 방식에서 PEM (photo elastic modulator)를 사용하는 방식으로 장비의 기능을 향상시켰다. 기존 quarter-wave plate를 사용하는 방식의 경우 Kerr signal을 구하기 위해 편광자와 검광자를 수직으로 두어 광량을 0으로 만들어야 한다. 그러나 금속의 경우 대부분 가시광선 영역에서 큰 반사율 때문에 측정되는 광량이 편광자와 검광자를 거치면서 넓은 각도 범위에서 최소값을 갖기 때문에 정확한 영점을 잡는 데 한계가 있다. 이러한 단점을 해결하기 위하여 우리는 PEM을 이용한 위상변조방식을 사용하였다. 위상변조 방식은 Kerr signal과 관계된 양을 PEM을 이용하여 50 kH ($1{\omega}$)와 100 kH ($2{\omega}$)의 진동 주파수에 공조시키고 이를 Lock-in-amplifier를 사용하여 탐지하기 때문에 좋은 sensitivity를 얻을 수 있을 뿐 아니라 Kerr ellipticity와 Kerr rotation을 동시에 측정할 수 있다. 자화에 필요한 전자석은 순철로 된 코어를 제작하여 챔버에 부착하였고 10 A에서 최대 7 kOe의 고자장을 얻을 수 있어 포화자화가 큰 물질에 대해서도 필요한 자성영역까지 측정이 가능하게 하였다. 또 저온 측정을 위해 SMOKE 샘플 홀더를 개조하여 액체 질소를 이용하여 100 K 근방의 영역에서 온도를 제어할 수 있도록 저온 장치를 구성하였다. 여기에서 샘플 근처에 위차한 e-beam heater가 장착된 고온 부분과 액체 질소 냉각, 온도감지를 위한 센서, cartridge heater가 장착된 저온 부분을 sapphire plate로 분리하여 저온용 cartridge heater의 파손을 최소화하였다. 이러한 SMOKE 시스템을 구성한 후에 우리는 Fe/Cr(001)시스템의 자성특성에 대해 연구하였다. Fe/Cr 시스템은 Fe/Cr/Fe의 exchange coupling이나 bulk Cr의 복잡한 자성 특성 때문에 주목을 받아왔다. 이 연구에서 우리는 저온 및 상온에서 Cr(001) 단결정 위에 증착된 Fe 박막의 자성 특성을 보고한다.

  • PDF

선박연료 가열용 250KW급 판형 IoT 전기히터의 기초연구 (Basic Study on 250KW-class IoT Electric Heater for Ship Fuel Heating)

  • 장성철
    • 사물인터넷융복합논문지
    • /
    • 제7권3호
    • /
    • pp.63-68
    • /
    • 2021
  • 국내의 전기히터 제조업체에서는 기존 제품의 효율을 향상시키는 기술 개발에 집중하고 있다. 선박 연료용 전기히터는 그 크기가 크고 소형화/고효율화에 대한 난이도가 높아 아직까지 기술개발을 시도하는 기업은 많지 않은 실정이다. 기존의 전기히터는 선박 엔진 연료의 유동경로가 단조롭기 때문에 가열매체의 열교환 튜브와의 접촉시간이 매우 짧아 가열 효율이 낮은 구조이며, 관형으로 제작되어 있기 때문에 가열효율과 무관하게 부피가 매우 크게 제작되므로 가열장치의 설치공간을 확보해야 한다. 이로인해 해외 선진사에서 적용하고 있는 관형 전기히터 장치는 내부의 특정부분이 손상되었을때 관형 가열기를 모두 분해하여야 하고, 열교환 튜브가 손상된 경우에는 열교환 튜브를 모두 분해해야 하므로 유지와 보수에 어려움이 있다. 본 연구에서는 250kW 용량급 판형 전기히터 가열기를 통해 시간당 10ton의 선박 엔진 연료를 가열할 수 있고, 최대온도를 150℃까지 설정할 수 있는 판형 전기히터에 대한 기초연구를 수행하였다.

추기노즐 충격판 주변의 급수가열기 동체 감육에 대한 유동해석 (A Flow Analysis in the surroundings of the Impingement Baffle of the Extracting Nozzle for Shell Wall Thinning of a Feedwater Heater)

  • 정선희;김경훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.2977-2982
    • /
    • 2007
  • Feedwater heaters of many nuclear power plants have recently experienced severe wall thinning damage, which will increase as operating time progresses. Several nuclear power plants in Korea have experienced wall thinning damage in the area around the impingement baffle - installed downstream of the high pressure turbine extraction steam line - inside number 5A and 5B feedwater heaters. At that point, the extracted steam from the high pressure turbine is two phase fluid at high temperature, high pressure, and high speed. Since it flows in reverse direction after impinging the impingement baffle, the shell wall of the number 5 high pressure feedwater heater may be affected by flow-accelerated corrosion. This paper describes the comparisons between the numerical analysis results using the FLUENT code and the down scale experimental data which effect on disclosing of the shell wall thinning of the high pressure feedwater heaters by porous plate.

  • PDF

Development of Induction Heated Hot Water System using Soft Switching PWM High Frequency Inverter

  • Lee, Jong-Kurl;Mun, Sang-Pil;Park, Man-Kyu;Nakaoka, Mustsuo
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2008년도 춘계학술대회 논문집
    • /
    • pp.325-328
    • /
    • 2008
  • This paper presents a new conceptual electromagnetic induction eddy current-based stainless steel plate spiral type heater for heat exchanger or dual packs Heater in hot water system boiler steamer and super heated steamer, which is more suitable and acceptable for new generation consumer power applications. In addition, an active clamped quasi resonant PWM high frequency inverter using trench gate IGBTs power module can operate under a principle of zero voltage soft commutation with PWM is developed and demonstrated fora high efficient induction heated hot water system and boiler in the consumer power applications This consumer induction heater power appliance using active clamp soft switching PWM high-frequency inverter is evaluated and discussed on the basis of the simulation and experimental results.

  • PDF