• 제목/요약/키워드: Heater plate

검색결과 114건 처리시간 0.019초

작동유체가 양방향성 태양열 열다이오드의 열성능 변화에 미치는 영향 분석 (Effect of Working Fluids on the Thermal Behavior of a Bi-directional Solar Thermal Diode)

  • 고영주;이헌주;천원기;;임상훈
    • 한국태양에너지학회 논문집
    • /
    • 제28권1호
    • /
    • pp.9-17
    • /
    • 2008
  • An experimental investigation has been carried out to study the effects of different working fluids on the behavior and thermal performance of a hi-directional thermodiode. The thermodiode was made up of two rectangular loops mounted between a collector plate and a radiator plate. Rotatable joints between the horizontal and inclined segments of the loops enable easy alteration of the direction of heat transfer. The loops and the tank were filled with a working fluid for effective heat transfer when the thermodiode was forwarded biased. Six different working fluids were tested with thermal conductivity values ranging from 0.1 to $0.56W/m-^{\circ}C$, thermal expansion coefficient values ranging from $1.8\;{\times}10^{-4}$ to $1.3\;{\times}\;10^{-3}\;K^{-1}$, and kinematic viscosity values ranging from $0.65\;{\times}\;10^{-6}$ to $100\;{\times}\;10^{-6}\;m^2/s$. Especially, mixtures of $Al_2O_3$ (30nm Particle) in deionized water have been tested for the volumetric ratios of 0.01, 0.02, 0.03, 0.1, 0.2%. Each experiment was carried out after the loop was filled with a working fluid for effective heat transfer and the thermodiode was forwarded biased. The solar thermodiode was heated by a radiant heater consisting of 20 halogen lamps that generated a heat flux of about $1000\;W/m^2$ on the collector surface. Results are given in terms of temperature development in different parts of the loop as heat is delivered from its hot end to the surrounding atmosphere by the radiator made of copper plates.

고진공하에서의 위성체 부품의 오염측정에 관한 연구 (A Study on the contamination measurement of spacecraft components under High Vacuum Environment)

  • 이상훈;서희준;문귀원;최석원
    • 한국진공학회지
    • /
    • 제11권2호
    • /
    • pp.87-96
    • /
    • 2002
  • 위성체가 작동하는 우주환경인 고진공상태에서는 위성체의 부품에서 발생 할 수 있는 outgassing으로 인해 위성체가 오염되어 위성체의 성능이 저하될 수 있으며, 특히 이차면경(second surface mirror) 및 광학렌즈 등을 오염시킴으로써 위성체 본연의 임무수행 실패라는 결과를 초래할 수도 있다. 따라서 지상에서 위성체의 부품에 대해 고온($85^{\circ}C$ 이상)과 고진공($5.0\times10^{-3}$ Pa 이하)의 상태를 모사하여 오염물질을 제거함으로써 outgassing의 발생을 막고, 아울러 오염근원을 검출할 수 있는 vacuum bake-out 시험이 필수적이라 할 수 있다. 이를 위해서 한국항공우주연구원 우주시험동에 설치된 bake-out 챔버를 이용하여 위성체 부품 중에서 SAR(Solar Array Regulator)와 MLI(Multi Layer Insulator)를 예를 들어 오염측정에 관한 연구를 수행하였다. 항공우주연구원의 bake-out 챔버는 rotary vacuum pump와 booster pump를 이용하여 5.0 Pa의 저진공을 형성하고, 2대의 cryopump를 이용하여$5.0\times10^{-3}$ Pa 이하의 고진공을 생성하게 된다. 또한 $180^{\circ}C$까지의 고온을 모사하기 위하여 챔버 shroud 안쪽에 ceramic 재질로 된 heater가 $30^{\circ}$간격으로 총 48개를 설치되어 있으며, 온도제어는 PID(Proportional Integral Differential) 제어 방식이 이용되었다. Vacuum bake-out 시험시에는 RGA(Residual Gas Analyzer)를 이용하여 각종 오염물질을 검출할 수 있고, TQCM(Thermoelectric Quartz Crystal Microbalance)을 사용하여 발생하는 오염물질의 방출률(outgassing rate)을 측정한다. 또한 필요시에는 IR/UV Spectrometer를 이용하여 witness plate에 흡착된 오염물질의 성분을 분석하여 위성체 부품으로의 적합성을 판단한다. SAR의 bake-out에서는 TQCM 측정결과 오염물질이 시간에 따라 감소추이는 보이지만 꾸준히 배출되고 있는 경향을 나타내고, RGA 분석결과 그 성분이 고분자 화합물로 추정되어 위성체 부품으로 사용하기에는 적절하지 못할 것으로 판단하였다. MLI의 bake-out에서는 RGA 및 witness plate를 이용한 오염측정 결과 특이한 오염물질을 발견할 수 없었다.

열펌프를 이용한 슬러리 돈분뇨 증발건조처리시스템 개발 (Development of Heat Pump Use Slurry Pig Manure Evaporation Drying System)

  • 김현태;최홍림
    • Journal of Biosystems Engineering
    • /
    • 제30권1호
    • /
    • pp.32-37
    • /
    • 2005
  • This study was conducted the slurry pig manure treatment by condensation drying of liquid from the slurry manure with a heat-pump and electric heater combined with air flow channel system. The system was designed as liquid and solid matters separation of slurry manure, and it can doing continuous input of slurry manure from a pig house, and it can operated year round use for pig farms. The separation of liquid and solid matters from slurry manure needed the prevention of solid accumulation in the system. The system was designed as closed space from outside air space for maximized evaporation of liquid and the condensation of liquid from slurry manure. The system can be operated the pig slurry manure treatment regardless of seasons in a yew. The separated evaporation water from the pig slurry manure by the heat-pump was satisfactorily pure water that can be used as washing water in livestock farms. The system can applicate to about 100 heads of pig, and the proper area of evaporation plate system was considered around $10\;m^2$. The input electrical energy of about 15 kWh which the cost equal to 250,000 won per month.

표면 연소기의 연소진동음의 발생조건 (Onset condition of the combustion-driven sound in a surface burner)

  • 권영필;이주원;이동훈
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.221-228
    • /
    • 1997
  • A strong combustion-driven sound from a surface burner made of a perforated metal fiber plate for premixed gas was investigated to clarify the physical mechanism of its generation. A simple model was developed for the acoustic power generation in terms of the heat transfer response function and the acoustic impedance of the burner. The acoustic impedance of the perforated metal fiber placed on the open exit was measured and the heat release response of the burner to the oscillating flow associated with the acoustic disturbance was expressed in terms of a response function. It was found that the power is generated by the heat release in response to the downstream particle velocity, in contrast to the upstream velocity in the case of the Rijke oscillation driven by a heater placed in the lower half of a columm with upstream flow. The measured frequencies of the oscillation were in agreement with the estimated resonance frequencies and their excitation was varied with the combustion conditions. For the same fuel rate, the excited frequency increases with the air ratio if it is low but decreases with the ratio if not so low. Such frequency characteristics were explained by assuming a heat release response function with a time constant and it was shown that the excited frequency decreases as the time constant increases.

  • PDF

콜로니 픽킹 로봇 시스템의 개발 (II) - 로봇 시스템의 성능실험 - (Development of Robot System for Colony Picking (II) - Performance test of the robot system -)

  • 이현동;김기대;나건영;이영규
    • Journal of Biosystems Engineering
    • /
    • 제28권5호
    • /
    • pp.449-456
    • /
    • 2003
  • A robot system was developed to pick desired colony. This robot system consisted of an image acquisition process which acquires the image information of colony, an illumination device which irradiates the object once when it gets the image of it, a picking head, a replicating head, a bed for fixing well-plates, and a sterilization device of sterilizing pin stained with colony. Picking pins were washed in an ultrasonic wave washing for takes ten seconds. Picking pins were dipped for sterilizing in alcohol for ten seconds. The time for resterilizing picking pins in a heater was five seconds. This performance test resulted 100% success rate for both the colony picking and the colony replication process. Considering the procedure in which 8 pins were smeared by colony, picked on a well plate, and sterilized as one cycle, the system could carry out one cycle in 110 seconds. It took about 138 minutes to pick around 600 colonies.

배플수에 따른 원통다관형 열교환기 성능에 관한 실험 적 연구 (An Experimental Study of Shell and Tube Heat Exchanger Performance with Baffle Spacing)

  • 이육형;김순영;박명관
    • 대한기계학회논문집B
    • /
    • 제25권12호
    • /
    • pp.1748-1755
    • /
    • 2001
  • The shell and tube heat exchangers were introduced to apply to a big capacity condenser and a high pressure feed water heater for power plant in the beginning of 1990s. Design and manufacturing technology fur shell and tube heat exchangers have been developed until now. But it is very difficult to calculate the expected performance characteristics of the shell and tube heat exchanger, because there are many design parameters to be considered according to internal structure and the shell side heat transfer mechanism complicately related to the design parameters. Design parameters to be considered in the design stage of shell and tube heat exchanger are shell and tube side fluids, flow rate, inlet and outlet temperature, physical properties, type of heat exchanger, outer diameter, thickness, length of tube, tube arrangement, tube pitch, permissive pressure loss on both sides, type of baffle plate, baffle cutting ratio. The propose of study is an analysis TEMA(Tubular Exchanger Manufacturers Association) E shell and tube heat exchanger performance with changing a number of baffles(3, 5, 7, 9, 11) and tubes(16, 20) and determined optimal baffle spacing.

공기순환구조를 갖는 축열지붕의 열전달해석 (Analysis of Heat Transfer of Thermal Storage Roof with the Air Circulation System)

  • 신우철;박석현;백남춘
    • 한국태양에너지학회 논문집
    • /
    • 제21권1호
    • /
    • pp.33-42
    • /
    • 2001
  • The paper discusses the modelling of the thermal storage roof with the air circulation system. In this system, the fully glazed absorber plate is put on the top of the conventional pitch roof made of massive concrete and acts as a solar air heater. Solar radiation collected into absorber is stored in the roof structure by radiation and convection so that it reduces the nighttime heating load through the roof. Another part of the energy is also transmitted to internal air drawn into the channel and is then introduced Into the room. To analysis the system, the energy balance equations are developed and are solved using a finite difference method. The calculation results show a good agreement with the measured ones obtained from our experiments. From the results, it is seen that the thermal storage roof with the air circulation system reduces significantly the conductive heat loss compared with that for the conventional roof and has the instantaneous solar collection efficiency of about 30%.

  • PDF

A Temperature-Controllable Microelectrode and Its Application to Protein Immobilization

  • Lee, Dae-Sik;Choi, Hyoung-Gil;Chung, Kwang-Hyo;Lee, Bun-Yeoul;Pyo, Hyeon-Bong;Yoon, Hyun-C.
    • ETRI Journal
    • /
    • 제29권5호
    • /
    • pp.667-669
    • /
    • 2007
  • This letter presents a smart integrated microfluidic device which can be applied to actively immobilize proteins on demand. The active component in the device is a temperature-controllable microelectrode array with a smart polymer film, poly(N-isopropylacrylamide) (PNIPAAm) which can be thermally switched between hydrophilic and hydrophobic states. It is integrated into a micro hot diaphragm having an integrated micro heater and temperature sensors on a 2-micrometer-thick silicon oxide/silicon nitride/silicon oxide (O/N/O) template. Only 36 mW is required to heat the large template area of 2 mm${\times}$16 mm to $40^{\circ}C$ within 1 second. To relay the stimulus-response activity to the microelectrode surface, the interface is modified with a smart polymer. For a model biomolecular affinity test, an anti-6-(2, 4-dinitrophenyl) aminohexanoic acid (DNP) antibody protein immobilization on the microelectrodes is demonstrated by fluorescence patterns.

  • PDF

전기보온압력밥솥 체결 구조물의 선형 및 비선형 구조 해석 (Linear and Nonlinear Structural Analysis for the Assembled Structures of Pressure Rice Cooker)

  • 이승표;김광석;고병갑
    • 한국산학기술학회논문지
    • /
    • 제10권3호
    • /
    • pp.493-499
    • /
    • 2009
  • 전기보온압력밥솥 체결 구조물은 오븐, 상부 가열판, 체결 링으로 구성된다. 전기보온압력밥솥은 압력이 작용하기 때문에 안전성 검토가 반드시 필요하다. 본 연구에서는 체결 구조물에 대하여 설계적 관점과 파손적 관점에서 구조 해석을 수행하였다. 설계적 관점에서 체결 구조물에 대한 선형 해석을 수행하였고, 파손적 관점에서 체결 링에 대한 비선형 해석을 수행하였다. 이들 해석을 통하여 전기보온압력밥솥 체결 구조물의 안전도를 평가하는 방법을 제시하였다.

단독주택용 태양열/지열 융복합시스템의 태양열 급탕성능 평가 (An Evaluation of the Solar Thermal Performance of the Solar/Geo Thermal Hybrid Hot Water System for a Detached House)

  • 백남춘;한승현;이왕제;신우철
    • 설비공학논문집
    • /
    • 제27권11호
    • /
    • pp.581-586
    • /
    • 2015
  • In this study, an analysis was performed on the performance of the solar water heating system with geo-thermal heat pump for a detached house. This system has a flat plate solar collector ($8\;m^2$) and a 3 RT heat pump. The heat pump acts as an auxiliary heater of the solar water heating system. These systems were installed at four individual houses with the same area of $100\;m^2$. The monitoring results for one year are as follows. (1) The average daily operating time of the solar system appeared to be 313 minutes in spring (intermediate season), and 135 minutes and 76 minutes in winter and summer respectively. The reason for the short operating time in summer is the high storage temperature due to low water heating load. The high storage temperature is caused by a decrease in collecting efficiency as well as by overheating. (2) The geothermal heat pump as an auxiliary heater mainly operates on days of poor insolation during the winter season. (3) Despite controlling for total house area, hot water consumption varies greatly according to the number of people in the family, hot water usage habits, etc. (4) The yearly solar fraction was 69.8 to 91.5 percent, which exceeds the maximum value of 80% as recommended by ASHRAE. So the solar collector area of $8\;m^2$ appeared to be somewhat greater for the house with an area of $100\;m^2$. (5) The observed annual efficiency of solar systems was relatively low at 13.5 to 23.6%, which was analyzed to be due to the decrease in thermal efficiency and the overheating caused by a high solar fraction.