• Title/Summary/Keyword: Heater Unit

Search Result 75, Processing Time 0.027 seconds

Evaluation of Apartment Cooling System by Multi-Criteria Decision Making Analysis (다기준 의사결정 분석에 의한 공동주택의 냉방시스템 평가)

  • Kang, Byoung-Min;Cho, Jin-Hwan;Kim, Young-Il;Chung, Kwang-Seop
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.8
    • /
    • pp.580-586
    • /
    • 2011
  • In this study, 3 cooling systems of apartment which are air-cooled air conditioner with indoor unit, water-cooled air conditioner with indoor unit and small capacity absorption chiller-heater with FCU have been evaluated by Multi-Criteria Decision Making Analysis. Weights of 7 selected factors which are economics, space, billing, constructability, human comfort, visibility and reliability are determined by expert group of 30 system designers and 30 construction engineers. Final weights were derived for 101 and 166 $m^2$ apartments. Analysis shows that small capacity absorption chiller-heater with FCU is the most favorable system for apartment cooling system.

Non-invasive Transcutaneous pCO2 Gas Monitoring System for Arterial Blood Gas Analysis

  • Bang, Hyang-Yi;Kang, Byoung-Ho;Eum, Nyeon-Sik;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.311-316
    • /
    • 2011
  • Monitoring the carbon dioxide concentration in arterial blood is vital for the evaluation and prevention of pulmonary disease. Yet, domestic pure arterial blood carbon dioxide sensor technologies are not being developed, instead all sensors are imported. In this paper, we develop a real time monitoring system for arterial blood partial pressure of carbon dioxide($pCO_2$) gas from the wrist by using a carbon micro-heater. The micro-heater was fabricated with a thickness of 0.3 ${\mu}m$ in order to collect the carbon dioxide under the skin. The micro-heater has been designed to perform temperature compensation in order to prevent damage to the skin. Two clinical trials of the system were undertaken. As a result, we demonstrated that a portable, transcutaneous carbon dioxide analysis($TcpCO_2$) device produced domestically is possible. In addition, this system reduced the analysis time significantly. Carbon films could reduce the unit price of these sensors by replacing the gold film used in foreign models. Also, we developed a real time monitoring system which can be used with optical biosensors for medical diagnostics as well as gas sensors for environmental monitoring.

The Design of an Automatic System for Dairy Cattle Breeding I - The Choice of Temperature Sensor for Body Temperature Measuring - (낙농의 자동화 시스템 구성 I - 체온 감지 온도센서의 선정 -)

  • 김형주;정길도;한병성;김용준;김동원;김명순
    • Journal of Biosystems Engineering
    • /
    • v.23 no.1
    • /
    • pp.83-90
    • /
    • 1998
  • In this paper the automatic system for dairy cattle has been desisted such as body temperature measuring unit, feed supplying unit and temperature control unit. Since e disease is strongly related to the body temperature of cattle, early detection of the abnormal temperature would prevent the severe problems which nay occur in dairy farms. An electronic component AD590J is used as temperature sensor for the system, The device is highly robust against the noise since the output signal is the current so it can be applied to a long distance sensing The resolution of signal is 0.1$^{\circ}C$ and the current is 10㎷ Also 12-bit A/D converter is desisted fir interfacing the sensor with a one-chip microprocessor. A temperature measuring experiment using the developed system has been done for measuring the temperature of human beings and the system was proven to be useful for measuring the body temperature of dairy cattle properly. A geared AC motor is used for the feed supplying unit The heater and fm are used as temperature control unit. The feed supplying unit and temperature control unit are well operating in the laboratory experiment.

  • PDF

Fabrication and characteristics of micro-machined thermoelectric flow sensor (실리콘 미세 가공을 이용한 열전형 미소유량센서 제작 및 특성)

  • Lee, Young-Hwa;Roh, Sung-Cheoul;Na, Pil-Sun;Kim, Kook-Jin;Lee, Kwang-Chul;Choi, Yong-Moon;Park, Se-Il;Ihm, Young-Eon
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.1
    • /
    • pp.22-27
    • /
    • 2005
  • A thermoelectric flow sensor for small quantity of gas flow rate was fabricated using silicon wafer semiconductor process and bulk micromachining technology. Evanohm R alloy heater and chromel-constantan thermocouples were used as a generation heat unit and sensing parts, respectively. The heater and thermocouples are thermally isolated on the $Si_{3}N_{4}/SiO_{2}/Si_{3}N_{4}$ laminated membrane. The characteristics of this sensor were observed in the flow rate range from 0.2 slm to 1.0 slm and the heater power from 0.72 mW to 5.63 mW. The results showed that the sensitivities $(({\partial}({\Delta}V)/{\partial}(\dot{q}));{\;}{\Delta}V$ : voltage difference, $\dot{q}$ : flow rate) were increased in accordance with heater power rise and decreasing of flow rate.

Research on Thermal Performance by Different Fins in a Solar Air Heater (태양열 공기난방기에서 핀의 형상에 따른 열전달 성능 평가)

  • Choi, Hwi-Ung;Hong, Boo-Pyo;Yoon, Jung-In;Son, Chang-Hyo;Choi, Kwang-Hwan
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.85-91
    • /
    • 2013
  • It is essential to reduce the amount of fossil fuel because facing with the natural problem such as a global warming. To achieve this goal, many of interests in the use of renewable energy is growing. Especially, as one of these renewable energy systems, a solar air heater invention has been conducted for enhancing the efficiency of solar air heater. According to this trend, scale-down sized experiment apparatus was constructed and performed for searching a proper fin and confirming the heat transfer performance by fin shape on constant heat condition to enhance efficiency of solar air heater. In this experiment, heat gain, convection heat transfer coefficient, number of transfer units, Nusselt number, Reynold's number, friction factor, performance factor were investigated in order to evaluate the thermal characteristics based on the real data obtained. By comparison with the each fin performance, a zigzag shape keeping a right angle to the plate had the highest value among them.

Heat Recovery Characteristics of the Exhaust Heat Recovery System with Heat Pipe Unit Attached to the Hot Air Heater in the Greenhouse (히트파이프를 이용한 온풍난방기 배기열회수 시스템의 열회수 특성)

  • Kang, K. C.;Kim, Y. J.;Ryou, Y. S.;Baek, Y.;Rhee, K. J.
    • Journal of Biosystems Engineering
    • /
    • v.26 no.5
    • /
    • pp.441-448
    • /
    • 2001
  • Hot air heater with light oil combustion is used as the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat capacity of the oil burred. In order to recover the heat of this exhaust gas and to use for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The system consisted of a heat exchanger made of heat pipes, ø15.88${\times}$600mm located in the rectangular box of 675(L)${\times}$425(W)${\times}$370(H)mm, an air suction fan and air ducts. The number of heat pipe was 60, calculated considering the heat exchange amount between exhaust gas and air and heat transfer capacity of a heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/h depending on the inlet air temperature of 12 to -12˚at air flow rate of 1.100㎥/h. The temperature of the exhaust gas left the heat exchanger dropped to 100$^{\circ}C$ from 270$^{\circ}C$ after the heat exchange between the suction air and the exhaust gas.

  • PDF

Study on the development of small-scale hydrogen production unit using steam reforming of natural gas (천연가스 개질 방식 중소형 고순도 수소제조 장치 개발 연구)

  • Seo, Dong-Joo;Chue, Kuck-Tack;Jung, Un-Ho;Park, Sang-Ho;Yoon, Wang-Lai
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.720-722
    • /
    • 2009
  • This work is mainly focused at developing the hydrogen production unit with the capacity of 20 $Nm^3/h$ of high purity hydrogen. At present steam reforming of natural gas is the preferable method to produce hydrogen at the point of production cost. The developed hydrogen production unit composed of natural gas reformer and pressure swing adsorption system. To improve the thermal efficiency of steam reforming reactor, the internal heat recuperating structure was adopted. The heat contained in reformed gas which comes out of the catalytic beds recovered by reaction feed stream. These features of design reduce the fuel consumption into burner and the heat duty of external heat exchangers, such as feed pre-heater and steam generator. The production rate of natural gas reformer was 41.7 $Nm^3/h$ as a dryreformate basis. The composition of PSA feed gas was $H_2$ 78.26%, $CO_2$ 18.49%, CO 1.43% and $CH_4$ 1.85%. The integrated production unit can produce 21.1 $Nm^3/h$ of high-purity hydrogen (99.997%). The hydrogen production efficiency of the developed unit was more than 58% as an LHV basis.

  • PDF

The Numerical Simulation of Fluid Flow in an Automotive HVAC module by using Commercial Code (상업용 코드를 이용한 차량용 HVAC module의 유동에 관한 전산모사)

  • KIM H. B.;HONG S. R.;CHUNG D. S.
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2003.08a
    • /
    • pp.194-199
    • /
    • 2003
  • The studying is to analyze characteristic of air flow and is used to design in an automotive HVAC module. The RNG k-e turbulence model with the Upwind Difference convection scheme and an unstructured hybrid mesh with arbitrary matching method were applied to the simulation. The comparing air flow characteristic of the basic HVAC module and total HVAC module with blower were discussed in the paper.

  • PDF

A Study on the User Required Unit Space in Elderly Housing -Special Reference to Yoodang Village (거주자 요구에 의한 유료 양로 시설의 단위 공간 계획 방향에 관한 연구-유당마을을 중심으로-)

  • 오혜경
    • Korean Institute of Interior Design Journal
    • /
    • no.3
    • /
    • pp.85-90
    • /
    • 1994
  • The purpose of this study was to present design direction of a unit plan in elderly housing. In order to perform the above purpose, this study was organized into two sections. First, literature review to understand the relationship between late adulthood development and housing environment, unit plan of elderly housing and design needs. Second, questionnaire and field survey research to seek a design direction of unit plan. Statistics were frequency, percentage, mean and crosstabulated analysis. The major findings were summerized as follows ; 1) The size of ideal single room was 20.4$m^2$-28.5$m^2$, and the minimum size for the couple was 28.5$m^2$. 2) The entrance of each room must not be faced each other, in case of the corridor type building like YooDang village. 3) Spare heater which can be turned on anytime was requested in bathroom especially for wintertime or whenever elderly need more heat. 4) The minimum size of closet was 1.5m per single room and the ideal size of it is over 1.8m. 5) The platform ondol type bed was ideal type bed was ideal for Korean elderly.

  • PDF