• Title/Summary/Keyword: Heated effluent water

Search Result 9, Processing Time 0.021 seconds

A Three-Dimensional Numerical Model of Thermal Discharge for Different Type of Effluent (배수방식에 따른 온수 방류의 3차원 수치모의)

  • Lee, Jin-Woo;Lee, Seung-Oh;Kim, Chang-Wan;Cho, Yong-Sik
    • 한국방재학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.387-390
    • /
    • 2007
  • The mixing characteristics of heated water discharged from different types of effluents are simulated using a commercial software, Flow-3D model. In order to verify the model, the comparison of numerical results with the experimental data are conducted for each type of effluent, the submerged and surface overfall. It is observed that the numerical results show a reasonable agreement with the experimental data. Based on this study the application to the heated water discharge problem in the field can be expected as a further study and it can be the fundamental data when determining the type of effluent in a powerplant.

  • PDF

ANALYSIS OF THE MIXING BEHAVIOR OF THE HEATED WATER FROM THERMAL DIFFUSER

  • Seo Il Won;Jeon Tae Myoung;Son Eun Woo;Kwon Seok Jae
    • Water Engineering Research
    • /
    • v.6 no.1
    • /
    • pp.1-15
    • /
    • 2005
  • The numerical model, FLUENT, was employed to investigate the effect of the heated water discharged from the diffuser of Boryung Power Plant. Temperature patterns of the thermal effluent discharged from two proposed types of the diffusers was evaluated for maximum flood and maximum ebb tide. The hydraulic model experiments were also performed in the reduced scale of 1/150 to verify the numerical simulation results. The buoyant jets discharged from the diffusers were found to be significantly affected by the ambient flows beyond the region where the effluent momentum was dissipated. Both the numerical and experimental results showed that the area of the excess isotherm for Type 1 diffuser was larger than that for Type 2 diffuser. Type 2 diffuser system was observed to be a more effective diffuser design than Type 1 diffuser system based on the temperature reduction and excess isotherm obtained from the numerical simulation in the ambient flows.

  • PDF

Heat Pump System Using Heated Effluent of Thermal Power Generation Plant as a Heat Source (해수를 이용한 화력발전소 폐열회수 히트펌프 시스템)

  • Ryou, Y.S.;Kang, Y.K.;Kim, Y.H.;Jang, J.K.;Kim, J.G.;Lee, H.M.;Kang, G.C.;Nah, K.D.;Huh, T.H.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.190-190
    • /
    • 2011
  • In South Korea the gross generation and heated effluent of power generation plant was 259 TWh and 4.73 billion tons in 2008. And then the waste heat from power generation was 388 TWh. It shows that the efficiency of thermal power generation plant is about 40%. Therefore to reduce $CO_2$ emission from thermal power generation plant, the energy of this heated effluent must be reused to heat buildings or farm facilities. In South Korea horticultural facilities of about 25% are heated in winter season. Total area of greenhouses which are heated is about 13,000 ha. Total heat amount needed to warm greenhouse of 13,000 ha in winter season is only 3.4% of total waste heat from power generation plant. In this study a heat pump system was designed to reuse the waste heat from power generation. Especially new heat exchanger was developed to recover the thermal energy from waste water and this model considered anti-corrosion against sea water and low cost for economic feasibility. This heat recovery system was installed in mango growing greenhouse around thermal power generation plant in Seogwipo-city, Jeju Special Self-Governing Province. The result of preliminary test shows that the heating cost of about 90% is saved as compared to boiler using tax free light oil as a fuel.

  • PDF

Thermal Effluent through Extruded Side Channel

  • Yoon, Tae-Hoon;Yook, Woon-Soo;Yi, Young-Kon
    • Korean Journal of Hydrosciences
    • /
    • v.6
    • /
    • pp.67-79
    • /
    • 1995
  • The reattachment of buoyant efflluent to a shore in a crossflow is investigated experimentally. The effluent is prodeced by discharging heated water through a projected side channel into a confined crossflow of the same depth. In the projecting effluent, the size of recirculating region, which is formed by deflected thermal plume on the lee of the effluent, tends to increase, but the maximum temperature decreases in the direction of the crossflow and it has more uniform transverse spreading compared to non-projected type. The heat flux across the crossflow is found to be independent of the projceted length of the side channel under relatively high buoyancy flux on the contrary to low buoyancy flux. The reattachment of th effluent can be specified by both velocity ratio and densimetric Froude number, whereas only the velocity ratio is governing factor to the reattachment of the effluent in the case of non-projecting type.

  • PDF

Heat Exchanger Design of a Heat Pump System Using the Heated Effluent of Thermal Power Generation Plant as a Heat Source for Greenhouse Heating (화력발전소의 온배수를 열원으로 이용하는 시설원예 난방용 히트펌프 시스템의 열교환기 설계기준 설정)

  • Ryou, Young Sun;Kang, Youn Ku;Jang, Jae Kyung;Kim, Young Hwa;Kim, Jong Goo;Kang, Geum Chun
    • Journal of Bio-Environment Control
    • /
    • v.21 no.4
    • /
    • pp.372-378
    • /
    • 2012
  • This study was carried out in order to determine the optimum length of a roll type PE pipe heat exchanger employed in the water-to-water heat pump system using the waste heat of the heated effluent flowed out from thermal power generation plants as a heat source. And the heat pump system of 30 RT for an experimental test was designed and manufactured. And also PE pipes were employed to recover the waste heat from the heated effluent. The inside diameter of PE pipe heat exchanger was 20 mm, the thickness was 2 mm and the diameter of a roll was 1,000 mm. And from the results of this study, we found that the optimum length of PE pipe heat exchanger was 75 m per the heat pump capacity of 1.0 RT (3.51 kW) and then the heating COP of heat pump system was 3.8.

Hematological Characteristics of Olive Flounder (Paralichthys olivaceus) in Culture Farm Influenced by Heated Effluent Water from a Power Plant in Summer (여름철 온배수 수역에 인접한 양식장 넙치(Paralichthys olivaceus)의 혈액 성상)

  • Chang, Young-Jin;Hur, Jun-Wook;Chin, Pyung
    • Journal of Aquaculture
    • /
    • v.15 no.4
    • /
    • pp.267-273
    • /
    • 2002
  • Effect of heated water from a power plant in summer on hematological characteristics of flounder (Paralichthys olivaceus) were investigated. Hematocrit level fluctuated between 15.7 and 16.3% in control farm, but it significantly increased to 17.7% in the high-WT farm. The corresponding values for hemoglobin concentration were 9.9~18.0 $g/㎗$ for the control farm and 6.2~19.4 $g/㎗$ for the exposed farm. The plasma cortisol remained between 0.6 and 2.8 ng/$ml$ in the former but significantly decreased 317.1 to 3.3 ng/$ml$ in the later. The plasma glucose also decreased from 36.5~46.0 to 23.5~36.5 mg/$dl$. Plasma osmolality decreased from 551.5~597.0 to 391.0~466.5 mOsm/kg.

Study on Effects of Seawater Fouling on a Plate-Frame Heat Exchanger (해수 파울링이 판형 열교환기 성능에 미치는 영향에 대한 고찰)

  • Heo, Jaehyeok;Lee, Dong-Won;Kim, Min-Hwi;Baik, Wonkeun;Yun, Rin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.8
    • /
    • pp.391-400
    • /
    • 2017
  • Understanding of seawater fouling characteristics is critical in designing a heat exchanger adapted in an effluent utilization system for a power plant. We reviewed three types of fouling mechanisms of general, biological, and crystallizing for a plate-frame heat exchanger, to be used for heat exchanging with heated effluent from a power plant. Also, mathematical models for each type of seawater fouling were suggested. Actual thermal resistance calculated from seawater fouling models were compared and implemented in designing a plate-frame heat exchanger. The bio-fouling model revealed the largest thermal resistance and the highest number of plates for a plate-frame heat exchanger under the same heat load. Overall heat transfer coefficient and pressure drop of a plate-frame heat exchanger under fouling conditions was lower by 58 percent and higher by 2.85 times than those under clean conditions, respectively.

Valuable Organic Liquid Fertilizer Manufacturing through $TAO^{TM}$ Process for Swine Manure Treatment

  • Lee, Myung-Gyu;Cha, Gi-Cheol
    • Journal of Animal Environmental Science
    • /
    • v.9 no.1
    • /
    • pp.45-56
    • /
    • 2003
  • $TAO^{TM}$ System is an auto-heated thermophilic aerated digestion process using a proprietary microbe called as a Phototropic Bacteria (PTB). High metabolic activity results in heat generation, which enables to produce a pathogen-free and digested liquid fertilizer at short retention times. TAO$^{TM}$ system has been developed to reduce a manure volume and convert into the liquid fertilizer using swine manure since 1992. About 100 units have been installed and operated in Korean swine farms so far. TAO$^{TM}$ system consists of a reactor vessel and ejector-type aeration pumps and foam removers. The swine slurry manure enters into vessel with PTB and is mixed and aerated. The process is operated at detention times from 2 to 4 days and temperature of 55 to $65^{\circ}C$. Foams are occurred and broken down by foam removers to evaporate water contents. Generally, at least 30% of water content is evaporated, 99% of volatile fatty acids caused an odor are removed and pathogen destruction is excellent with fecal coliform, rotavirus and salmonella below detection limits. The effluent from TAO$^{TM}$ system, called as the "TAO EFFLUX", is screened and has superb properties as a fertilizer. Normally N-P-K contents of screened TAO Efflux are 4.7 g/L, 0.375 g/L and 2.8 g/L respectively. The fertilizer effect of TAO EFFLUX compared to chemical fertilizer has been demonstrated and studied with various crops such as rice, potato, cabbage, pumpkin, green pepper, parsley, cucumber and apple. Generally it has better fertilizer effects and excellent soil fertility improvement effects. Moreover, the TAO EFFLUX is concentrated through membrane technology without fouling problems for a cost saving of long distance transportation and a commercialization (crop nutrient commodity) to a gardening market, for example.

  • PDF

Effect on Digestion Efficiency by Adding Microbial Agent in Mesophilic Two-stage Anaerobic Digester (중온2단혐기성소화조에 미생물제재 주입시 소화효율에 미치는 영향)

  • Jung, Byung-Gil;Kim, Seok-Soon;Kang, Dong-Hyo;Sung, Nak-Chang;Choi, Seung-Ho;Lee, Hee-Pom
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.11 no.3
    • /
    • pp.75-86
    • /
    • 2003
  • In the near future, the capacity of conventional anaerobic digester is thought to be insufficient because of the increase of the total solids from expansion of intercepting sewer, sewage quantity and direct input of night soil from near apartment districts. The objectives of this study was to investigate the improvement of digestion efficiency using microbial agent(Bio-dh). The system was a pilot-scale, two-staged, anaerobic sludge digestion system. The first-stage digester was heated and mixed. The agitation velocity of the first-stage digester was 120rpm. The second-stage digester was neither heated nor mixed. The Digestion temperature was kept at $35{\pm}1^{\circ}C$ The detention time of digester was 19 days. The dosage of sewage sludge and microbial agent were $0.65m^3/day$ and $0.5{\ell}/day$, respectively. The experiments was run for 25days. Three times a week, $COD_{Mn}$ and SS of effluent, TS, VS, and biogas production rate were measured. Temperature, pH, and alkalinity were measured daily. The results were as follows ; Without microbial agent, digestion efficiencies ranged 46.0%~50.9%(mean=48.6%), with microbial agent(Bio-dh), digestion efficiencies ranged 52.8%~57.3%(mean=54.2%). Consequently, microbial agent(Bio-dh) increased the sludge digestion efficiency about 12%. Also, Without microbial agent, the mean concentration of $COD_{Mn}$ and SS of second-stage digester effluent were 1,639mg/L, 4,888mg/L respectively. With microbial agent, the mean concentration of $COD_{Mn}$ and SS of second-stage digester effluent were 859mg/L, 2,405mg/L respectively. Consequently, microbial agent(Bio-dh) increased the removal efficiency of $COD_{Mn}$ and SS about 47.6% and 50.8%, respectively.

  • PDF