• 제목/요약/키워드: Heat-source analysis

검색결과 822건 처리시간 0.031초

암모니아-물 랭킨사이클의 증발기에서의 엑서지 및 엔트랜시 성능 특성 해석 (Performance Characteristics Analysis of Evaporator in Ammonia-Water Rankine Cycle Based on Exergy and Entransy)

  • 김경훈;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.621-628
    • /
    • 2019
  • The use of the ammonia-water zeotropic mixture as a working fluid in the power generating system has been considered as a proven technology for efficient recovery of low-grade heat sources. This paper presents a thermodynamic performance analysis for ammonia-water evaporator using low-grade heat source, based on the exergy and entransy which has been recently introduced as a physical quantity to describe the heat transfer ability of an object. In the analysis, effects of the ammonia mass fraction and source temperature of the binary mixture are investigated on the system performance such as heat transfer, effectiveness, exergy destruction, entransy dissipation, and entransy dissipation based thermal resistance. The results show that the ammonia mass concentration and the source temperature have significant effects on the thermodynamic system performance of the ammonia-water evaporator.

저온열원 활용을 위한 암모니아-물 재생 랭킨사이클의 엑서지 해석 (Exergy Analysis of Regenerative Ammonia-Water Rankine Cycle for Use of Low-Temperature Heat Source)

  • 김경훈;고형종;김세웅
    • 한국수소및신에너지학회논문집
    • /
    • 제23권1호
    • /
    • pp.65-72
    • /
    • 2012
  • Rankine cycle using ammonia-water mixture as a working fluid has attracted much attention, since it may be a very useful device to extract power from low-temperature heat source. In this work, the thermodynamic performance of regenerative ammonia-water Rankine cycle is thoroughly investigated based on the second law of thermodynamics and exergy analysis, when the energy source is low-temperature heat source in the form of sensible energy. In analyzing the power cycle, several key system parameters such as ammonia mass concentration in the mixture and turbine inlet pressure are studied to examine their effects on the system performance including exergy destructions or anergies of system components, efficiencies based on the first and second laws of thermodynamics. The results show that as the ammonia concentration increases, exergy exhaust increases but exergy destruction at the heat exchanger increases. The second-law efficiency has an optimum value with respect to the ammonia concentration.

공기열원 2중히트싱크 열펌프의 성능해석 (Performance Analysis of Heat Pump System with Air Source Evaporator and Single Unit Dual Sink Condenser)

  • 우정선;이세균;이재효;박효순
    • 태양에너지
    • /
    • 제18권4호
    • /
    • pp.11-22
    • /
    • 1998
  • Floor panel heating system using hot water is the primary heating system of domestic residential building. This paper presents the results of performance analysis of the heat pump system with air source evaporator and single unit dual sink(SUDSk) condenser. The heat exchanger combines two separated condensers into a single condenser and the object of the SUDSk condenser is to release energy to dual sinks, i.e. air for air heating system and water for panel heating system in one single unit. Simulation program is developed for single unit dual source(SUDS) SUDSk heat pump system and some experimental data are obtained and compared with simulation results. Differences of heating capacity and COP in dual source operating mode are 7% and 8% respectively. Simulation results are in good agreement with test results. Therefore, developed program is effectively used for design and performance prediction of dual source dual sink heat pump system with SUDS evaporator and SUDSk condenser.

  • PDF

자계 분포시 열유동 현상 분석을 통한 결합계 해석 (The coupling field analysis of a thermal transfer phenomenon by an magnetic field)

  • 손락원;장광용;배재남;김승주;최승길;이주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.862-863
    • /
    • 2007
  • In this article, we researched the characteristics of heat transfer of the bimetal for over-current protection device. Bimetal consists of two metals which have a different thermal expansion coefficient. To analyze the heat transfer characteristics, by using a bimetal which has a single metal, we analyzed the temperature distribution when bimetal acts a switch. As usual, heat source is applied to the bimetal. But, in the over-current protection switch, the current become heat source. So, by using the current as source, we performed the magnetic analysis and thermal analysis together.

  • PDF

비접촉식 열 공구를 이용한 미세 형상 가공에서의 열 영향부에 대한 수치적 모사에 관한 연구 (A study on numerical analysis of heat affected zone in detailed shape processing using Non-contact hot tool)

  • 김효찬;안동규;이상호;양동열
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.569-572
    • /
    • 2003
  • In VLM-ST process, the fine detailed shape processing process is needed due to the use of thick sheets for layers. The developed process perform the fine detailed shape processing in VLM-ST parts using non-contact hot tool. To predict the heat-affected zone and temperature distribution of VLM-ST parts in detailed shaping, the heat flux from the tool to the surface was calculated for the finite element analysis by modeling the tool as a heat source of radiation. The dominant process parameters such as the radiated heat input, the tool speed, and the gap between the tool tip and the foam sheet (tool height) were considered in the analysis. The results showed a good agreement with the experiments.

  • PDF

레이저보조가공에서 중첩열원에 관한 해석 연구 (Analysis of Overlapping Heat Zones in Laser-Assisted Machining)

  • 백종태;이춘만
    • 한국정밀공학회지
    • /
    • 제32권12호
    • /
    • pp.1023-1029
    • /
    • 2015
  • Laser-assisted machining (LAM) is one of the most effective methods for enhancing the machinability of difficult-to-cut materials, such as titanium alloys and various ceramics, and has been studied by many researchers. LAM is a method that facilitates machining by softening a workpiece using a laser heat source. The advantages of the LAM process are decreases in tool wear, cutting force, and surface roughness. However, when the material is over-heated, melting or burning can occur. This study analyzed the heat source distribution with regard to overlapping of preheating on the laser heating path with an acute angle, a right angle and obtuse angles. Then, a power reduction method was proposed to reduce the melting and burning of the workpiece.

GTA 오버레이 용접부의 열유동 해석을 위한 용접열원 모델링 (Welding Heat Source Modeling for Heat Flow Analysis of GTA Overlay Welding)

  • 김용래;채현병;김재웅
    • Journal of Welding and Joining
    • /
    • 제31권4호
    • /
    • pp.62-66
    • /
    • 2013
  • Overlay welding is carried out to improve the corrosion resistance, wear resistance and heat resistance on the surface of the chemical plant and steelmaking plant structures. In overlay welding, control of the bead size and the temperature distribution of weldment are particularly important because that is directly connected to the improvement of quality and productivity. The aim of this study is to model the welding heat source that is very useful to analyze the bead size and temperature distribution of weldment. To find the welding heat source model, numerical analyses are performed by using FE software MSC-marc.

동특성 시뮬레이션을 이용한 공기, 지열 및 지하 저수조 열원 소형 열펌프의 경제성 분석 (Economical Analysis of a Small Capacity Heat Pump utilizing Heat Sources of Air, Geothermal and Underground Water Tank using Dynamic Simulation)

  • 양철호;김영일;정광섭
    • 한국지열·수열에너지학회논문집
    • /
    • 제8권4호
    • /
    • pp.17-23
    • /
    • 2012
  • Due to reinforcement of international environment regulation and high oil prices, interest in renewable energy is growing. Countries participating in UNFCCC are continuously putting efforts in reducing greenhouse gas after enforcing Kyoto Protocol into effect on Feb, 2005. Energy used in buildings, which relies heavily on fossil fuel accounts for about 24% of total energy consumption. In this study, air, geothermal and water source heat pump systems for an 322 $m^2$ auditorium in an office building is simulated using TRNSYS version 17 for comparing energy consumptions. The results show that energy consumptions of air, geothermal and water source heat pumps are 14,485, 10,249, and 10,405 kWh, respectively. Annual equal payments which consider both initial and running costs become 5,734,521, 6,403,257 and 5,596,058 Won. Thus, water source heat pump is the best economical choice.

모드해석과 관측기를 이용한 1차원 온도분포의 실시간 예측 (Real Time Estimation in 1-Dimensional Temperature Distribution Using Modal Analysis and Observer)

  • 안중용;박영민;정성종
    • 대한기계학회논문집B
    • /
    • 제25권2호
    • /
    • pp.195-201
    • /
    • 2001
  • An inverse heat conduction problem(IHCP) arises when unknown heat fluxes and whole temperature field are to be found with temperature measurements of a few points. In this paper, observers are proposed as solution algorithm for the IHCP. A 1-dimensional heat transfer problem is modeled with modal analysis and state space equations. Position of the heat source is estimated through test heat inputs and the autocorrelation among a few of temperature data. The modified Bass-Gura method is used to design a state observer to estimate the intensity of heat source and the whole temperature field of a 1-dimensional body. To verify the reliability of this estimator, analytic solutions obtained from the proposed method are compared.