• Title/Summary/Keyword: Heat-cool test

Search Result 49, Processing Time 0.018 seconds

The Effects of Heat Transfer Characteristics of Fibers on the Warm/Cool Touch of Insulating Nonwovens (섬유의 열전달 특성이 보온용 부직포의 접촉온냉감에 미치는 영향)

  • Kim, Hee-Sook
    • Korean Journal of Human Ecology
    • /
    • v.8 no.1
    • /
    • pp.125-134
    • /
    • 1999
  • The purpose of this study was to investigate the effects of heat transfer characteristics of fibers on the Qmax of insulating nonwovens. The effects of fiber type, moisture content, washing cycles on the Qmax were observed. The correlations between Qmax measured by KES-F7 system and subjective warm/cool touch perception test was analyzed. The results obtained were as followed: 1. Heat transfer characteristics of fibers effected on the Qmax of insulating nonwovens. 2. Moisture transport properties of fibers effected considerably on the Qmax of nonwovens and the increasing rate of Qmax by increasing moisture content was much higher at wool than polyester. 3. As a result of subjective perception test, subjective warm/cool touch and wettness of wool nonwoven was increased obviously by increasing moisture content. 4. At the same moisture content, wool nonwoven showed higher subjective cool touch and wetness than polyester. 5. In the physical properties of nonwovens, thickness was the most effective factor on the Qmax of insulating nonwovens.

  • PDF

Study on Long-term Deterioration Properties of Porcelain Insulators with Aluminous System (알루미나계 자기애자의 장기 피로특성에 관한 연구)

  • Han, Se-Won;Cho, Han-Goo;Lee, Dong-Il;Cho, In-Hyuk
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.562-563
    • /
    • 2005
  • In case of aged porcelain, the failure in basic performance tests happened in cool-heat tests. Based on this characteristic, we studied the method predicting failure phenomena through more severe accelerated cool-heat ageing and accelerating thermal mechanical performance tests. Test results indicated that the thermal stress by temperature gradient was more severe parameter than thermal stress by quenching cycles within a category of standard or accelerating methods. And there is no the deterioration of statistic strength, but the deterioration of strength according to accelerating tests is serious.

  • PDF

Study on Performance and Aging Test of Porcelain Insulators for Transmission Line (송전용 자기재 애자의 성능평가 및 가속열화시험)

  • 한세원;조한구;박기호;이동일;최인혁
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.9
    • /
    • pp.842-850
    • /
    • 2003
  • The suspension insulators are subjected to harsh environments in service for a long time. The long-term reliability of tile insulators is required for both mechanical and electrical performances. This study describes some basic performance tests and accelerated aging test by cool-heat cycling methods and thermal mechanical performance test methods on alumina porcelain insulators (new and aged) used for transmission line in KOREA. There was no fail in electrical and mechanical performance tests such as a high voltage strength, a flashover voltage, and an impact strength in all samples. But in the case of accelerating aging tests which have above 9$0^{\circ}C$ temperature gradient, fracture phenomena was happened by a thermal shock in tile aged sample(sample A) with low alumina porcelain body. It was indicated that sample A was more severely aged than other samples. According to results of HRB test and microstructural analysis, it was reasoned that insulator bodies with the matrix reinforced with alumina crystalline phase have advantages over the suppression of crack advance. And cool-heat aging and mechanical thermal ageing tests shows that a temperature gradient is more effective to accelerating than a cycling number.

Ablation Characteristics of Bovine Liver According to Cool-Tip Temperature of RFA Equipment (고주파 열치료 장비의 Cool-Tip 온도에 따른 소간의 소작 특성)

  • Choi, Young-Jae;Kim, Jeong-Koo
    • Journal of radiological science and technology
    • /
    • v.38 no.2
    • /
    • pp.155-161
    • /
    • 2015
  • This study confirmed the correlation between the change of the cooling water in internal cooling system and the size of the ablation site of bovine liver in RF heat treatment equipment. The bovine liver was resection with $4{\times}4{\times}4cm^3$ in 2cm cool-tip and with $6{\times}6{\times}6cm^3$ in 3cm cool-tip for the experiments. Area and perimeter of the ablation site for bovine liver were measured by Freehand techniques of MRI. It showed area and perimeter decreased during cool-tip temperature rises 6 and 12 minutes ablation using a 2cm and 3cm cool-tip. The correlation of cool-tip temperature and area and perimeter was statistically significant the result are shown(p=.000). The measurements of area and perimeter were more accurate with MRI in actual measurements and MRI for ablation range. The statistical results using Paired sample T-test was also significant(p=.038). The ablation range of bovine liver decreased according as cooling water temperature increases in RF heat treatment equipment for reason of carbonization occurred due to does not accurately pass the RF energy. Therefore, it is considered the effect of RF heat treatment would be increased if the temperature of the cooling water consistently maintain the low temperature in order to reduce the generation of carbide at RF heat treatment and RF energy is delivered accurately.

A Study of Hair Damage by Magic Straight Perm

  • Lim, Sun-Nye
    • Applied Microscopy
    • /
    • v.42 no.3
    • /
    • pp.129-135
    • /
    • 2012
  • In this study, the changes in hair quality before and after Magic straight perm have been evaluated through a hair damage measurement method. For this, a healthy high school student's (age18 years) wavy hair was selected and permed on the left and right sides. Then, the changes caused by physical methods which were applied during the fl at iron-based Magic straight perm were evaluated based on the hair damage measurement method before and after the Magic straight perm. According to the protein release test after the Magic straight perm, 1.26% in average and 0.14% was observed in Cool Magic straight perm sample. In a field emission scanning electron microscopy (FE-SEM) test, saw teeth-shaped partial desquamation of cuticle cells and impurities were observed in the warm-treated hair sample. In atomic force microscope (AFM), line-profile is a method to represent roughness data on hair. According to analysis on 3-dimensional (3D) images, the hair with Cool Magic straight perm was lower than the hair with Warm Magic perm in terms of the color change of 3D images. In addition, vertical changes were observed in the hair with Cool Magic perm. As a result, irregular surface roughness was observed. This study proposed a method to minimize hair damage by cooling down the heat with the cool hair straightener as soon as the Warm Magic was finished.

Application of Miniature Heat Pipe for Notebook PC Cooling (노트북 PC CPU 냉각용 소형 히트파이프 Packaging 연구)

  • Moon, Seok-Hwan;Hwang, Gunn;Choy, Tae-Goo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.6
    • /
    • pp.799-803
    • /
    • 2001
  • Miniature heat pipe(MHP) with woven-wired wick was used to cool the CPU of a notebook PC. The pipe with circular cross-section was pressed and bent for packaging the MHP into a notebook PC with very limited compact packaging space. A cross-sectional area of the pipe is reduced about 30% as the MHP with 4mm diameter is pressed to 2mm thickness. In the present study a performance test has been performed in order to review varying of operating performance according to pressed thickness variation and heat dissipation capacity of MHP cooling module that is packaged on a notebook PC. New wick type was considered for overcoming low heat transfer limit when MHP is pressed to thin-plate. The limiting thickness or pressing is shown to be within the range of 2mm∼2.5mm through the performance test with varying the pressing thickness. When the wall thickness of 0.4mm is reduced to 0.25mm for minimizing conductive thermal resistance through the wall of heat pipe, heat transfer limit and thermal resistance of MHP were improved about 10%. In the meantime, it is shown that the thermal resistance and heat transfer limit for the MHP with central wick type are higher than those of MHP with existing wick types. The results of performance test for MHP cooling modules with woven-wired wick to cool a notebook PC shows the stability as cooling system since T(sub)j(Temperature of Processor Junction) satisfy a demand condition of 0∼100$\^{C}$ under 11.5W of CPU heat.

Development of Cooling System for Thermal Management and Water Balance in Fuel Cell Vehicle (연료전지 차량의 열 및 물 균형 유지를 위한 냉각 시스템 개발)

  • Kim, Seong-Kyun;Lee, Seung-Yong;Kim, Chi-Myung;Park, Yong-Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.113-117
    • /
    • 2006
  • This paper Is for development of cooling module in order to maintain heat and water balance in fuel cell vehicle. Thermal management system for fuel cell is disadvantage because the temperature of coolant is lower than that of ICE and heat duty of radiator is higher. By CFD simulation, cool ing module was developed for water balance of system. Hot chamber test and hot area/high altitude test on cool ing module was completed.

  • PDF

Evaluation of the Wear Comfort of Women's Fitted Sports T-shirts Made from Cool-Touch Fabrics (냉감 소재를 활용한 밀착형 여성 스포츠 상의의 착용쾌적성 평가)

  • Kim, Soyoung;Choi, Jiyoung;Lee, Heeran;Hong, Kyunghi
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.41 no.5
    • /
    • pp.929-938
    • /
    • 2017
  • This research investigated the effects of cool touch fabrics on thermo-regulating physical properties and subjective evaluation using a 3D fitted women's T-shirts in wear test. Qmax, clothing microclimate, microclimate wettedness, thermogram and subjective vote were observed during rest-right after an exercise-rest protocol. As a result, there was no single determining physical variable to explain the reasons of cool sensations of T-shirts made of cool touch fabric across the entire protocol. Qmax could partly predict a wear sensation at the initial stage when only insensible perspiration was presented. Simultaneous observation of temperature/humidity gradient understand from the inside to the outside of the clothing layer or microclimate wettedness calculated using vapor pressure were helpful to figure out the performance of cool touch fabric, especially at the later stage of the protocol when sweating was excessive. It was especially difficult to connect thermo-regulating physical variables to the subjective evaluation during transient conditions such as 'right after exercise' stage. It is necessary to measure the amount of heat and moisture transferred from the skin to the outside of clothing along with the physical properties measured in this study to understand the detailed mechanisms of why a cool sensation is evoked from tight fitting T-shirts made of newly developed cool touch fabrics.

Total Enclosed Type Traction Motor Development and Test for Rolling Stock (철도차량용 전폐형 견인전동기 개발 및 시험)

  • Kim, Jung-Chul;Kim, Bong-Chul;Park, Yeong-Ho;Han, Jeong-Soo
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.3032-3036
    • /
    • 2011
  • Cooling type of traction motor for EMU in domestic is mostly an open type. Its system is a cooling air entered through air inlet cool down a traction motor and an hot air by traction motor get out air outlet. It is easy to cool it down but hard to maintain it. To improve an ability of maintenance, a total enclosed type traction motor is already developed and used in abroad, not an opne type. So we developed a total enclosed type traction motor which will be used in domestic and abroad EMU. We tried to reduce a weight and a size compared with the abroad one. In contrast with open type traction motors which cool off inside of motors, total enclosed motors cool down by cooling exterior frame of motors. In this case, cooling fins or air fan blowing to the exterior of motors are applied. The total enclosed type traction motor developed by us have two housing to block the foreign substance into inner of a motor and have two cooling fan to easy to reduce a heat happened at a coil. In this paper, design of a cooling structure of the total enclosed traction motor developed twice and performance verification through test will be discussed.

  • PDF

An experimental study on the cooling performance of carbon dioxide heat pump system for fuel cell vehicles (연료전지 자동차용 이산화탄소 열펌프 시스템에서의 냉방 성능에 관한 실험적 연구)

  • Kim Sungchul;Park Minsoo;Kim Min Soo;Hwang Inchul;Noh Youngwoo;Park Moonsoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.378-383
    • /
    • 2005
  • This experimental study presents the results of the cooling performance test of a $CO_2$ heat pump system for fuel cell vehicles. The experimental facility provides the cool ing and heating environment for cabin and heat releasing component. The test loop is designed to target the cooling capacity of 5kW and its coefficient of performance (COP) of 2.2. The cooling performance of the heat pump system is strongly dependent on the refrigerant charge and the degree of superheat. We carried out basic experiments to obtain optimum refrigerant charge and the degree of superheat level at the internal heat exchanger outlet. The heat pump system for fuel cell vehicles is different from that of engine-driven vehicles, where the former has an electricity-driven compressor and the latter has the belt-driven (engine-driven) compressor. In the fuel cell vehicle, the compressor speed is an independent operating parameter and it is controlled to meet the cooling/heating loads. Experiments were carried out at cooling mode with respect to the compressor speed and the incoming outdoor air speed. The results obtained in this study can provide the fundamental cool ing performance data using the $CO_2$ heat pump system for fuel cell vehicles.

  • PDF