• Title/Summary/Keyword: Heat-Regeneration

Search Result 115, Processing Time 0.023 seconds

Uncontrolled Regeneration Characteristics of SiC DPFs using DPF Test Rig (DPF 테스트 리그를 이용한 SiC DPF의 이상연소 특성)

  • Oh, Kwang-Chul;Lee, Chun-Hwan;Cho, Taik-Dong
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.80-86
    • /
    • 2008
  • Uncontrolled regeneration characteristics of two different type SiC DPFs(diesel particulate filters) were investigated by DPF test rig devised to facilitate DPF evaluation, especially for regeneration and MSL(maximum soot loading) test similar to engine dynamometer test. In order to estimate the limits of maximum filter temperature and temperature gradient causing filter fracture, such as crack or whitening, the temperature distributions inside the filter were measured by thermocouples. The maximum filter temperature was observed near the rear plane of central filter region due to heat accumulation by exothermic reaction of PM but the maximum temperature gradient occurred at the boundary of high filter temperature. These two parameters induced the different SiC DPFs to fracture with different modes, whitening and crack.

An Experimental Study on Effects of Soot Loading and Mass Flow Rate on Pressure Drop and Heat Transfer in Catalyzed Diesel Particulate Filter (촉매 코팅 DPF의 soot loading과 유량 변화에 따른 압력강하 및 열전달에 관한 실험적 연구)

  • Cho, Yong-Seok;Noh, Young-Chang;Park, Young-Joon;Kim, Duk-Sang
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.15 no.3
    • /
    • pp.72-78
    • /
    • 2007
  • A diesel particulate filter causes progressive increase in back pressure of an exhaust system due to the loading of soot particles. To maintain the pressure drop caused by DPF under proper level, a regeneration process is mandatory when excessive loading of soot is detected in the filter. It is a major reason why the relation between the amount of soot and the pressure drop in a DPF becomes crucial. On the other hand, pressure drop varies with not only the soot loading but also conditions of exhaust gas such as mass flow rate. Therefore, the relation among them becomes complicated. Furthermore, the characteristics of heat transfer in a DPF is another crucial parameter in order for the filter to avoid thermal crack during regeneration period. This study presents characteristics of pressure drop under various conditions of soot loading and mass flow rate in catalyzed diesel particulate filter. This study also shows characteristics of heat transfer in DPF when high temperature gas flows into the filter. Experiments reveal that the soot loading and mass flow rate affect characteristics pressure drop independently. Experiments also indicate that the amount of coating material has little influence on pressure drop with changes in soot loading and mass flow rate. However, increased catalyst coating may lead to the improved heat transfer which is efficiency to reduce thermal stress of the filter.

Experimental Investigation on the Performance of Small-Sized Dehumidification Rotor for Residential Use (가정용 소형 제습로터의 성능에 대한 실험적 연구)

  • Han, Ji-Chao;Kim, Nae-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2344-2349
    • /
    • 2015
  • In Korea, summer is hot and humid, and air-conditioners consume too much electricity due to large amount of latent heat. Simultaneous usage of dehumidifier may reduce the latent heat and save the electricity. In this study, dehumidification performance was measured in a constant temperature and humidity chamber for a small-sized dehumdification rotor made of inorganic fiber impregnated with metallic silicate. Variables were rotor speed, room temperature, regeneration temperature, room relative humidity and frontal velocity to the rotor. Results showed that there existed optimum rotor speed (1.0 rpm), and optimum regeneration temperature ($100^{\circ}C$). Above the optimum rotor speed, incomplete regeneration is responsible for reduced dehumidification. Above the optimum regeneration temperature, increased temperature difference between regeneration and dehumidification process is responsible for reduced dehumidification. The amount of dehumidification also increases with the increase of relative humidity, dehumidification temperature and flow velocity into the rotor.

Hwangnyeonhaedok-tang Extracts Ameliorates Atopic Dermatitis via Epidermal Lipid Barrier Regeneration in NC/Nga Mouse (황련해독탕의 피부지방장벽개선을 통한 Th2 분화조절이 아토피피부염 완화에 미치는 효과)

  • Son, Seong Han;Ahn, Sang Hyun;Park, Sun-Young;Kim, Kibong
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.32 no.3
    • /
    • pp.90-99
    • /
    • 2018
  • Objectives Hwangnyeonhaedok-tang is a Korean herbal medical treatment that removes toxic heat, fever and inflammation. The purpose of this study was to investigate the effect of Hwangnyeonhaedok-tang treatment on the relief of atopic dermatitis (AD) through regeneration of skin lipid barrier. Methods Male NC/Nga mice (20 g, 6 week age) were used. Each 10 mice were allocated to the control group (Ctrl), the AD-induced with no treatment group (AE), and the group which induced AD after administering Hwangnyeonhaedok-tang extract (HT). To induce AD-like skin lesions, sodium dodecyl sulfate (SDS) (Sigma-Aldrich, USA) was rubbed on the back of each mouse to remove the lipid lamella of the stratum corneum, and Dermatophagoides (D.) farinae crude extract was applied. HT group was orally administered Hwangnyeonhaedok-tang after induction of AD. IL-4 IL-13, $p-I{\kappa}B$, iNOS, Sudan Black B (SB), loricrin, and filaggrin were observed to confirm the effect. Results In HT group, AD skin score was decreased by 46%. The cytokine IL-4 and IL-13, which can identify Th2 differentiation, was reduced by 73% and 58% each. Anti-inflammatory effects were observed in $p-I{\kappa}B$ and iNOS by 69% and 54%, respectively. Finally, SB showed that the regeneration of the lipid layer and the increase of the regeneration power of loricrin and filaggrin were increased by 437% and 464%, respectively. Conclusions From the study result, we observed that Hwangnyeonhaedok-tang treatment alleviates AD by decreasing skin score, reducing Th2 differentiation, inducing anti-inflammatory, and increasing skin lipid barrier regeneration. Thus, Hwangnyeonhaedok-tang treatment would be considered as an effective AD relieving treatment.

The Establishment of Tumor Necrosis Factor Receptor-associated Protein1 (TRAP1) Transgenic Mice and Severe Fat Accumulation in the Liver of TRAP1 Mice during Liver Regeneration

  • Im, Chang-Nim;Zheng, Ying;Kim, Sun Hye;Huang, Tai-Qin;Cho, Du-Hyong;Seo, Jeong-Sun
    • Interdisciplinary Bio Central
    • /
    • v.5 no.4
    • /
    • pp.9.1-9.7
    • /
    • 2013
  • Introduction: Tumor necrosis factor receptor-associated protein 1 (TRAP1) is a mitochondrial heat shock protein (HSP), which belongs to HSP90 family. It plays important roles in regulating mitochondrial integrity, protecting against oxidative stress, and inhibiting cell death. Recent studies suggest that TRAP1 is linked to mitochondria and its metabolism. In this study, we established TRAP1 transgenic mice and performed partial hepatectomy (PH) on wild-type (WT) and TRAP1 transgenic mice to investigate the function of TRAP1 during liver regeneration. Results and Discussion: We found that TRAP1 was highly expressed in liver as well as kidney. In addition, liver regeneration slightly decreased together with increased fatty liver and inflammation at 72 hr after PH in TRAP1 transgenic mice compared with WT control group mice. Concomitantly, we observed decreased levels of p38 protein in TRAP1 transgenic mice compared with WT control group mice. These results suggest that TRAP1 plays a critical role in liver energy balance by regulating lipid accumulation during liver regeneration. Conclusions and Prospects: To our knowledge, we reported, for the first time, that liver regeneration slightly reduced together with increased fat accumulations after PH in TRAP1 transgenic mice compared with WT control group mice. Concomitantly, we observed decreased levels of p38 protein in TRAP1 transgenic mice compared with WT control group mice. Overexpression of TRAP1 might affect liver regeneration via disturbing mitochondrial function leading to fatty liver in vivo.

Thermodynamic Performance Analysis of Regenerative Organic Flash Cycle (재생 유기플래시 사이클의 열역학적 성능 해석)

  • Kim, Kyoung Hoon;Kim, Man Hoe
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.9
    • /
    • pp.589-596
    • /
    • 2016
  • Recently organic flash cycle (OFC) has been proposed which is a vapor power cycle where heat addition occurs with the working fluid remaining in the liquid state. This study proposes a modified OFC with regeneration and carries out thermodynamic performance analysis of the system utilizing low-temperature heat source in the form of sensible energy. Effects of working fluid and flash temperature are systemically investigated on the system performance such as net power production and thermal efficiency. Results show that the net power production has a peak value with respect to the flash temperature but the thermal efficiency increases with the flash temperature. The regenerative system shows higher thermal efficiency compared to the original OFC and improved potential for recovery of low-temperature heat sources.

DNS of turbulent heat transfer in a concentric annulus (동심 환형관 내 난류 열전달의 직접 수치 모사)

  • Chung Seo Yoon;Sung Hyung Jin
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.827-830
    • /
    • 2002
  • A direct numerical simulation is performed for turbulent heat transfer in a concentric annulus at $Re_{Dh}=8900\;and\;Pr=0.71$ for two radius ratios ($R_{1}/R_{2}=0.1\;and\;0.5$) and $q^{\ast}=1.0$. Main emphasis is placed on the transverse curvature effect on near-wall turbulent thermal structures. Near-wall turbulent structures close to the inner and outer walls are scrutinized by computing the lower-order statistics. The fluctuating temperature variance and turbulent heat flux budgets are illustrated to confirm the results of the lower-order statistics. The present numerical results show that the turbulent structures near the outer wall are more activated than those near the inner wall, which may be attributed to the different vortex regeneration processes between the inner and outer walls.

  • PDF

Performance Characteristics of the Desiccant Cooling System in Various Outdoor and Load Conditions (외기조건에 따른 제습냉방시스템의 성능 특성)

  • Lee, Dae-Young;Chang, Young-Soo
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.623-628
    • /
    • 2009
  • Desiccant based air conditioning system offers a promising alternative to conventional one using vapour compression refrigeration for energy saving and greenhouse gas reduction. It is a heat driven cycle which has high potential for the use of low grade heat source such as the waste heat from the cogeneration plant or the solar thermal energy. In this study, the cooling performance of a desiccant cooling system incorporating a regenerative evaporative cooler was characterized in various operation conditions through numerical simulation. The cooling capacity and COP were evaluated at various outdoor conditions, regeneration temperatures, and supply flow rates. Based on the performance characteristics, the optimal control scheme was discussed to minimize the cooling cost at part load condition.

  • PDF

Study Characteristics in Packed Tower of Liquid Desiccant Solar Cooling System Using Counter Flow Configuration

  • Rahmanto, R. Hengki;Choi, K.H.;Agung, B.;Sukmaji, I.C.
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.168-174
    • /
    • 2009
  • High water vapour content in air can cause a number of problems as for human or surrounding materials. For human a high water vapour can create physiological stress, discomfort, and also can encourage ill health. While, the cause for the environment is can accelerate the corrosion of metals, accelerate the growth of spores and mould, can reduce the electrical resistance of insulators and etc. Desiccant systems have been proposed as energy saving alternatives to vapor compression air conditioning for handling especially the latent load and also sensible load. Use of liquid desiccants offers several design and performance advantages over solid desiccants, especially when solar energy is used for regeneration. The liquid desiccants contact the gas inside the packed tower of liquid desiccant solar cooling system and the heat transfer and mass transfer will occur. This thesis is trying to study the characteristics inside the packed tower of dehumidifier systems. This characteristics consist of mass transfer rate, heat transfers rate, human comfort and energy that consume by the system. Those characteristics were affected by air flow rates, air temperature and humidity, and desiccant temperature and all that variation will influence the performance of the systems. The results of this thesis later on can be used to determine the best performance of the systems.

  • PDF