• Title/Summary/Keyword: Heat-Bridge

Search Result 182, Processing Time 0.034 seconds

A Study on Hydration Heat and Dry Shrinkage of High Durability / Strength Concrete for the Bridge Slab of Express Railway (고속철도 교량상판 슬래브용 고내구/고강도 콘크리트의 수화열 및 건조수축 특성 개선연구)

  • 박정준;백상현;정재헌;박경재;윤원기;엄태선
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.725-728
    • /
    • 1999
  • The bridge slab of express railway was designed for high strength concrete (design strength 400kgf/$\textrm{cm}^2$). In case the slab is made with the concrete using type I cement, used much amount of cement can cause cracks through concrete by hydration heat or dry shrinkage. In this study we targeted to solve above problems using type III cement. We could decrease the cement ratio in concrete using type III cement than type I cement. The concrete using type III cement showed good workability and compressive strength, and showed better properties in hydration heat and dry shrinkage than that using type I cement

  • PDF

The Mechanical Properties of Concrete Using Blended Super Low Heat Cement (혼합형 초저발열 시멘트를 사용한 콘크리트의 물성-현수교 앵커리지 콘크리트 대상-)

  • 송용순;강석화;손명수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.341-344
    • /
    • 1999
  • In the case of the offshore concrete structures like the anchorage block of a suspension bridge of Kwangan Grand Road, there is a need of the concrete which has low heat of hydration and good resistance for sea-water attack. In this study, the blended super low heat cement which satisfies that requirement was developed and several tests were carried out. The concrete using the blended super low heat cement showed lower adiabatic temperature rise than 3$0^{\circ}C$ and good early strength. Also, its passed charge(coulomb) to resist chloride ion penetration was very low.

  • PDF

Temperature Distribution and It's Contribution to Self-equilibrium Thermal Stress in Bridge (교량 단면 내 온도분포에 따른 자체평형 열응력 해석)

  • Kwak, Hyo-Gyoung;Kwon, Se-Hyung;Ha, Sang-Hee
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.24 no.5
    • /
    • pp.531-542
    • /
    • 2011
  • The time-dependent temperature distribution across the section in bridges is determined on the basis of the three-dimensional finite element analyses and numerical time integration in this study. The material properties which change with time and thermal stress of concrete are taken into account to effectively trace the early-age structural responses. Since the temperature distribution is nonlinear and depends upon many material constants such as the thermal conductivity, specific heat, hydration heat of concrete, heat transfer coefficients and solar radiation, three representative influencing factors of the construction season, wind velocity and bridge pavement are considered at the parametric studies. The validity of the introduced numerical model is established by comparing the analytical predictions with results from previous analytical studies. On the basis of parametric studies for four different bridge sections, it is found that the creep deformation in concrete bridges must be considered to reach more reasonable design results and the temperature distribution proposed in the Korean bridge design specification need to be improved.

Experimental Research for Seismic Performance of Circular Hollow R.C. Bridge Pier (원형중공 콘크리트 교각의 내진성능에 대한 실험적 연구)

  • 한기훈;이강균;정영수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.671-676
    • /
    • 1999
  • Because of relatively heavy dead weight of concrete itself and unavoidable heat of massive concrete in bridge piers, circular hollow columns are widely used in Korean highway bridges. Since the occurrence of 1995 Kobe earthquake, there have been much concerns about seismic design for various infrastructures, inclusive of bridge structures. It is, however, understood that there are not much research works for nonlinear behavior of circular hollow columns subjected to earthquake motions. The ultimate of this experimental research is investigate nonlinear behavior of circular hollow reinforced concrete bridge piers under the quasi-static cyclic load, and then to enhance their ductility by strengthening the plastic hinge region with glassfiber sheets. It is concluded from quasi-static tests for 7 bridge piers that energy dissipation capacity and curvatures for a given displacement ductility factor $\{\mu}=frac{\Delta}{\Delta_y}$are about 20% higher for the seismically designed columns and about 70% higher for the retrofitted piers than the nonseismically designed columns in a conventional way.

  • PDF

A Study on the Heat Source Equation for the Thermal Effect Analysis of Guss Asphalt Pavement (구스 아스팔트의 열 영향 해석을 위한 열원방정식에 관한 연구)

  • Park, Hyun-Woong;Lee, Wan-Hoon
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.3
    • /
    • pp.96-102
    • /
    • 2019
  • The study of thermal effect on the structure is carried out in the case of Guss asphalt which is paved at the temperature of $240^{\circ}C$ or higher in the bridge pavement of the steel deck bridges. However, studies on the heat source data applicable to numerical analysis are insufficient, the temperature load is used as a joint load. In this study, the heat source equations that can be directly loaded on the plate elements, although limited, are presented using the measured temperature data in the Guss asphalt pavement and its validity is confirmed by a brief numerical analysis.

A Study on the Thermal Bridge Reduced Stiffeners for the Reduction of Window Overall Hear Transfer Coefficient (창문 열관류율 저감을 위한 열교 저감형 보강재 연구)

  • Jang, Hyok-Soo;Kim, Young-Il;Chung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.71-80
    • /
    • 2015
  • Steel stiffener is required for reinforcing the structure of the window frame made of versatile but weak PVC material. Steel stiffener however becomes a source of greater heat loss and frequently plays a role of thermal bridge due to its high thermal conductivity. To maintain thermal resistance similar to PVC frame, steel stiffener is perforated to reduce the effective heat transfer area. To compensate the structural strength of the steel stiffener which is weakened by the perforation, the thickness is increased. Increase in thickness will also increase the thermal heat resistance. Five samples which are PVC frame, PVC frame + original steel stiffener, PVC frame + 30% perforated steel stiffener, PVC frame + 50% perforated steel stiffener, PVC frame + 65% perforated steel stiffener are modeled and simulated for 2nd moment of area and thermal resistance. Therm/window version 6.3 is used for thermal analysis. The results show that among the five samples analyzed, PVC frame + 65% perforated steel stiffener best satisfies both structural strength and thermal resistance.

Thermal Analysis of Wall/Floor Intersections in Building Envelope

  • Ihm, Pyeongchan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.12 no.2
    • /
    • pp.97-107
    • /
    • 2004
  • Wall/floor intersection is important parts of a building envelope system. These intersections can be sources of thermal bridging effects and/or moisture condensation problems. This paper provides a detailed analysis of the thermal performance of wall/floor intersection. In particular, two-dimensional steady-state and transient solutions of the heat conduction within the wall/floor joint are presented. Various insulation configurations are considered to determine the magnitude of heat transfer increase due to wall/floor joint construction.

Thermal Bridge and Heat Transfer Analysis for Each Part in Residential Building According to Construction of Wood-based Finishing Material (목질 마감재 구성에 따른 주거용 건축물 부위별 열교 및 전열성능 분석)

  • Seo, Jungki;Jeong, Su-Gwang;Kim, Sumin
    • Journal of the Korean Wood Science and Technology
    • /
    • v.45 no.3
    • /
    • pp.343-359
    • /
    • 2017
  • Many researches and policies have been carried out for saving energy in buildings. However, there are a few studies of thermal characteristics of wood-based materials that have been widely used as structural materials and finishing materials in buildings. In this study, thermal bridging areas were found to investigate thermal performance of residential building using non wood-based materials and wood-based materials. And heat transfer analysis of 16 case studies according to composition of structural materials and finishing materials was conducted. Also in this experiment, Physibel Trisco was used as the heat transfer analysis simulation tool, which conforms to the calculation method of ISO 10211. Analytical modeling was also carried out according to the ISO 10211, and the boundary temperature conditions were set at room temperature $20^{\circ}C$ and outdoor temperature $-11.3^{\circ}C$ (Seoul standard) according to the energy saving design standard in South Korea. Applied structures are classified according to the cases of concrete structure with non wood-based finishing materials, concrete structure with wood-based finishing materials and wood structure. Analyzed building elements were divided into a wall, a roof, an interlayer floor and a bottom floor. As a result, it can be confirmed that the thermal bridge of the concrete structure and wood structure were caused by the geometrical and material causes. In addition, the structural thermal bridge was caused in the discontinuity of the insulation in the concrete structure. Also it was confirmed that the linear heat transfer coefficient of the wall decreases when the wood-based materials are applied to the concrete structure.

A CASE REPORT FOR CONSTRUCTION OF FIXED BRIDGE BY ONE PIECE CASTING TECHNIQUES (One Piece Casting법에 의한 Fixed Bridge)

  • Kim, In-Chul;Kim, Kwang-Nam
    • The Journal of the Korean dental association
    • /
    • v.10 no.12
    • /
    • pp.809-812
    • /
    • 1972
  • This present paper is concerned with four unit fixed bridge construction by one piece casting technique in the case of missing of upper left second premolar and first molar. The authors had good clinical results with following advantages. 1. The complete bridge can be delivered to the patient for two appointments. 2. The laboratory procedures for solder joint are not necessary. 3. A one piece casting can be properly shaped without weak joints. 4. The casting can be heat-treated to insure an ideal molecular structure. 5. Porcelain veneers can be applied without weakening or melting solder joints.

  • PDF