• Title/Summary/Keyword: Heat wave

Search Result 738, Processing Time 0.027 seconds

An Experimental Investigation on the Airside Performance of Fin-and-Tube Heat Exchangers Having Sinusoidal Wave Fins (사인 웨이브 휜-관 열교환기의 공기측 성능에 관한 실험연구)

  • Kim, Nae-Hyun;Cho, Jin-Pyo;Yoon, Baek
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.4
    • /
    • pp.355-367
    • /
    • 2004
  • The heat transfer and friction characteristics of the heat exchangers having sinusoidal wave fins were experimentally investigated. Twenty-nine samples having different waffle heights (1.5 mm and 2.0 m), fin pitches (1.3mm to 1.7mm) and tube rows (one to three) were tested. Focus was given to the effect of the waffle configuration (herringbone or sinusoidal) on the heat transfer and friction characteristics. Results show that the sinusoidal wave geometry provides higher heat transfer coefficients and friction factors than the herringbone wave geometry, and the difference increases as the number of row increases. The i/f ratios of the herringbone wave geometry, however, are larger than those of the sinusoidal wave geometry. Compared to the herringbone wave geometry, the sinusoidal wave geometry yielded a weak row effect, which suggests a superior heat transfer performance at the fully developed flow region. Possible explanation is provided considering the flow characteristics in wavy channels. Within the present geometric range, the effect of the waffle height on the heat transfer coefficient was not prominent. The effect of the fin pitch was also negligible. Existing correlations highly overpredicted both the heat transfer coefficients and friction factors. A new correlation was developed using the present data.

Computational Simulation of Heat flow phenomena in Newly Designed Heat Sinks (뉴 디자인된 히트싱크의 열 유동 현상 컴퓨터 시뮬레이션)

  • Lim Song Chul;Choi Jong Un;Kang Kae Myung
    • Korean Journal of Materials Research
    • /
    • v.14 no.11
    • /
    • pp.775-779
    • /
    • 2004
  • For improvement of heat dissipation performance, heat analysis is conducted on the newly designed heat sinks under two convection conditions by using computational fluid dynamics(CFD). Three types of heat sink, plate, wave and top vented wave, are used, and convection conditions are the variations of gravity direction at natural convection and of fan location at forced convection. The results of analysis showed that the heat resistances of top vented wave heat sink were $0.17^{\circ}C$/W(forced convection) and $0.48^{\circ}C$/W(natural convection). In the case of natural convection, gravity direction affected heat flow change, and protection against heat performance was superior in case of z-axis gravity direction. Under the forced convection, all the heat sinks revealed superior thermal characteristics in the fan position of z-axis rather than y-axis. In this study, it was observed that the top vented wave type heat sink showed the best ability of heat radiation comparing with the others.

Characteristics of Heat wave Mortality in Korea (우리나라 폭염 인명피해 발생특징)

  • Kim, Do-Woo;Chung, Jea-Hak;Lee, Jong-Seol;Lee, Ji-Sun
    • Atmosphere
    • /
    • v.24 no.2
    • /
    • pp.225-234
    • /
    • 2014
  • Analysis of the cause of death (Statistics Korea) showed that heat wave caused 442 deaths (21 per a year) from 1991 to 2011 in Korea. The number of summer heat-related deaths (heat disorders) increased exponentially as heat wave prolonged. In 1994 when the extreme heat wave prevailed, there were 92 heat-related deaths. Seasonally, heat-related deaths occurred most frequently in early August when air temperature is highest for a year, but it is frequent as well in late July when air temperature increases rapidly after withdrawal of Changma. The frequency of deaths by age has begun to increase from 40s and more than half of total deaths were occurred in the elderly (${\geq}60$). Except retired elderly, the most vulnerable group (job and age) was the elderly agricultural workers and the next was the jobless people in 40 s~50 s, assumed as homeless people. The most vulnerable regions were Hapcheon-gun, Uiryong-gun, and Sanchen-gun, which are inland rural area in Gyeongsang-do where the heat wave occurs most frequently in Korea. The heat-related death rate increased rapidly when air temperature exceeded $33^{\circ}C$ in both of the urban and rural area. Interestingly, the heat-related death were observed in the relatively lower temperature in the cities ($29^{\circ}C$), as compare to the rural area ($31^{\circ}C$).

Heat flow Analysis of Heat Sink Using the Computational Simulation (전산모사를 이용한 히트싱크의 열 유동 해석)

  • Lim Song Chul;Chang Si Young;Kim Hyon Tae;Lee Dong Heon;Kang Kae Myung
    • Korean Journal of Materials Research
    • /
    • v.14 no.7
    • /
    • pp.522-528
    • /
    • 2004
  • Heat analysis of the plate type and wave type heat sink were carried out by using computational simulation. The heat resistance and air flow of two heat sink models were analysed according to natural and forced convection condition and positions of fan. When a fan was at the position of z-axis and y-axis in forced convection, the heat resistances of plate type heat sink were $0.17^{\circ}C/W$, and $0.28^{\circ}C/W$ respectively. In the case of wave type heat sink, they were $0.18^{\circ}C/W$ and $0.53^{\circ}C/W$. As the air flow velocities were averagely $0.386\;m/s\~3.269\;m/s$, air flow velocity of plate type heat sink was faster than that of wave type. In this experiment, it was observed that the plate type heat sink showed a good ability of heat radiation comparing with wave type one.

Thermal Analysis of Heat Sink Models using CFD simulation (CFD를 이용한 히트싱크의 열 해석)

  • Lim, Song-Chul;Lee, Myung-Ho;Kang, Kae-Myung
    • Korean Journal of Materials Research
    • /
    • v.15 no.12
    • /
    • pp.829-832
    • /
    • 2005
  • Thermal analysis of new designed heat-sink models was carried out according to the natural ana the forced convection using computational fluid dynamics(CFD). Heat resistance of wave type, top vented wave type and plate type of heat sink was compared with each other As the direction of fin and air flow are vertical(z-axis), it is shown that radiant heat performance of all of heat sinks was superior than other experimental conditions. Especially, the heat resistance of top vented wave heat sink was $0.17^{\circ}C/W$(forced convection) and $0.48^{\circ}C/W$(natural convection). The radiant heat performance of heat sink was increased with increasing the height of fin and the width of fin pitch.

A Definition of Korean Heat Waves and Their Spatio-temporal Patterns (우리나라에 적합한 열파의 정의와 그 시.공간적 발생패턴)

  • Choi, Gwang-Yong
    • Journal of the Korean Geographical Society
    • /
    • v.41 no.5 s.116
    • /
    • pp.527-544
    • /
    • 2006
  • This study provides a definition of heat waves, which indicate the conditions of strong sultriness in summer, appropriate to Korea and intends to clarify long term(1973-2006) averaged spatial and temporal patterns of annual frequency of heat waves with respect to their intensity. Based on examination of the Korean mortality rate changes due to increase of apparent temperature under hot and humid summer conditions, three consecutive days with at least $32.5^{\circ}C,\;35.5^{\circ}C,\;38.5^{\circ}C,\;and\;41.5^{\circ}C$ of daily maximum Heat Index are defined as the Hot Spell(HS), the Heat Wave(HW), the Strong Heat Wave(SHW), and the Extreme Heat Wave(EHW), respectively. The annual frequency of all categories of heat waves is relatively low in high-elevated regions or on islands adjacent to seas. In contrast, the maximum annual frequency of heat waves during the study period as well as annual average frequency are highest in interior, low-elevated regions along major rivers in South Korea, particularly during the Changma Break period(between late July and mid-August). There is no obvious increasing or decreasing trend in the annual total frequency of all categories of heat waves for the study period However, the maximum annual frequencies of HS days at each weather station were recorded mainly in the 1970s, while most of maximum frequency records of both the HW and the SHW at individual weather stations were observed in the 1990s. It is also revealed that when heat waves occur in South Korea high humidity as well as high temperature contributes to increasing the heat wave intensity by $4.3-9.5^{\circ}C$. These results provide a useful basis to help develop a heat wave warning system appropriate to Korea.

A Study on the temperature Distributions at the Vicinity of a Very Fast Moving Heat Source (매우 빠르게 움직이는 열원 주위의 온도분포에 관한 연구)

  • Cho, Chang-Joo;Juhng, Woo-Nam;Lee , Yong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.8
    • /
    • pp.162-169
    • /
    • 1999
  • Fourier heat conduction law becomes invalid for the situations involving extremely short time heating, very low temperatures and fast moving heat source(or crack), since the wave nature of heat propagation becomes dominant. For these conditions, the modified heat conduction equation with the finite propagation speed of heat in the medium could be applied to predict heat flux and temperature distributions. In this study, temperature distributions at the vicinity of a very fast moving heat source are investigated numerically. Thermal fields are characterized by thermal Mach numbers(M) defined as the ratio of moving heat source speed to heat propagation speed in the solid. In the transonic and supersonic ranges($M{\ge}1$), thermal shocks are shown, which separate the heat affected zone from the thermally undisturbed zone.

  • PDF

Numerical method of hyperbolic heat conduction equation with wave nature (파동특성을 갖는 쌍곡선형 열전도방정식에 관한 수치해법)

  • 조창주
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.22 no.5
    • /
    • pp.670-679
    • /
    • 1998
  • The solution of hyperbolic equation with wave nature has sharp discontinuties in the medium at the wave front. Difficulties encounted in the numrtical solution of such problem in clude among oth-ers numerical oscillation and the representation of sharp discontinuities with good resolution at the wave front. In this work inviscid Burgers equation and modified heat conduction equation is intro-duced as hyperboic equation. These equations are caculated by numerical methods(explicit method MacCormack method Total Variation Diminishing(TVD) method) along various Courant numbers and numerical solutions are compared with the exact analytic solution. For inviscid Burgers equa-tion TVD method remains stable and produces high resolution at sharp wave front but for modified heat Conduction equation MacCormack method is recommmanded as numerical technique.

  • PDF

The Hazard Viz-platform for the Establishment of Heatwave Response Strategies (폭염 대응전략 수립을 위한 폭염위험도 시각화 플랫폼)

  • Kim, Miyun
    • Journal of Korea Multimedia Society
    • /
    • v.23 no.5
    • /
    • pp.683-699
    • /
    • 2020
  • Recently, the earth's highest temperature is rising due to severe climate change and heat wave. In addition, due to the increase of elderly population over 65, the number of heat patients is also increasing. In particular, the elderly who live alone in poor living environments, the lower income group, and the socially disadvantaged, such as children and pregnant women, are exposed to the dangers of heat waves, so the government's practical measures are urgently needed. In this study, we will build a visualization platform for each level of heat wave and provide the necessary countermeasure solution according to the heat wave risk. "The Hazard Visualization Platform for Heatwave" provide not only simple information, but also a customized safety service for citizens to prevent heatwaves, respond to heatwaves, and utilize heat wave information.

Investigation of Operation and Improvement for Heat Watch Warning System to Provide Health-Weather Information (보건기상정보 제공을 위한 폭염특보 운영현황 및 개선방안 조사)

  • Hwang, Mi-Kyoung;Kang, Yoon-Hee;Kim, Sungmin;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.28 no.2
    • /
    • pp.277-285
    • /
    • 2019
  • Heat watch warning systems are operating in Korea and several other countries (China, the United Kingdom, France, the United States, Germany, Australia, and Japan). The heat wave indices used in this system are the heat index, perceived temperature, the wet bulb globe temperature, and the daily maximum temperature. To improve the heat wave advisory and warning system, some suggestions have been made. The meteorological-health index (i.e., indirect index), has especially been proposed in previous studies. This information should be provided not only to vulnerable groups (seniors, infants, and children), but also to outdoor workers who may be particularly exposed to heat waves. In addition, to have sufficient preemptive response times, the need for an extension of the heat watch warning period was suggested. Finally, the subdivision of administrative units and risk stages was proposed.