• 제목/요약/키워드: Heat transformer

검색결과 121건 처리시간 0.032초

일체형 주상용 몰드 변압기의 덕트에 따른 열해석 특성 연구 (The Thermal Analysis of Pole Mount Mold Transformer with One-body Molding by Duct Condition)

  • 조한구;이운용;박영두
    • 한국전기전자재료학회논문지
    • /
    • 제17권3호
    • /
    • pp.348-352
    • /
    • 2004
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and ow loss, but it needs some cooling method because heat radiation between each winding is difficult. The life of transformer is significantly dependent on the thermal behavior in windings. Many transformer designers have calculated temperature distribution and hot spot point by finite element method(FEM) to analyze winding temperature rise. In this paper, The thermal analysis of pole mount mold transformer with one body molding by duct condition is investigated and the test result of temperature rise is compared with simulation data.

100kVA 주상용 몰드 변압기의 온도분포 해석 (The Temperature Distribution Analysis of Mold transformer)

  • 조한구;이운용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.125-129
    • /
    • 2004
  • The mold transformers have been widely used in underground substations in large building and have some advantages in comparison to oil-transformer, that is low fire risk, excellent environmental compatibility, compact size and high reliability. In addition, the application of mold transformer for outdoor is possible due to development of epoxy resin. The mold transformer generally has cooling duct between low voltage coil and high voltage coil. A mold transformer made by one body molding method has been developed for small size and low loss, but it needs some cooling method because heat radiation between each winding is difficult. The life of transformer is significantly dependent on the thermal behavior in windings. Many transformer designers have calculated temperature distribution and hot spot point by FEM(finite element method) to analyze winding temperature rise. In this paper, the temperature distribution and thermal stress analysis of 100kVA pole cast resin transformer for power distribution are investigated by FEM program.

  • PDF

부하변화에 대한 변압기 진동 분석 (Transformer Vibration Analysis for a variation of Load)

  • 강창구;곽희로;정찬수;조국희;권혁승
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1993년도 추계학술발표회논문집
    • /
    • pp.103-106
    • /
    • 1993
  • This paper describes the modeling of winding vibration for a variation of load and temperature. The structural changes in transformer windings due to heat cause the change of vibration patterns. The vibration signals were detected by the accelerometer on the transformer windings. The real values were compared with estimated value using least-squares method, vibration model was cstablished and with this model, error compared with original signal was less than -50[db]. These results could be applied to diagnosis of incipient failures of the power transformers.

  • PDF

펄스 변압기를 이용한 비접지 MOSFET의 게이트 구동 회로 설계 (Design of the gate drive circuit for floating MOSFET using the pulse transformer)

  • 박종연;이봉진
    • 산업기술연구
    • /
    • 제27권B호
    • /
    • pp.15-20
    • /
    • 2007
  • This paper presents the new design method for the gate driver circuit of the floating MOSFET by using the pulse transformer. Each parameters of the proposed circuit are delivered by the numerical calculation method. By considering inner characteristics of MOSFET, the gate driver makes to increase the efficiency of the power conversion and decrease operating heat. Computer simulations and to experimental results for a Buck Converter are presented in order to validate the proposed method.

  • PDF

고-기 화학열변환기의 최적설계 및 성능해석에 관한 연구 (A Study on the Optimal Design and Performance Analysis of the Solid-Gas Chemical Heat Transformer)

  • 최승훈;이세일;백일현;최익수
    • 공업화학
    • /
    • 제8권5호
    • /
    • pp.729-736
    • /
    • 1997
  • 산업폐열을 활용하기 위해 금속염화물-암모니아계 화학열변환기를 설계하고 1kW-1hr 용량의 장치개발을 하였다. 이는 $170^{\circ}C$ 열원을 $210^{\circ}C$ 이상으로 승온시키는 화학열펌프 시스템으로서, 효율적인 화학반응기의 설계를 위하여 필요한 반응물의 양과 반응물의 조건 등을 산출하는 정적계산과 동적모사를 수행하였다. 모사결과 열교환면적이나 반응기내 염의 양 등의 변수에 따라 시스템의 온도와 출력이 변함을 알 수 있었고 또한 반응물질의 양과 겉보기밀도 및 장치구조의 영향을 고찰하고 최적조건을 결정할 수 있었다. 4단계 작동사이클에 따라 운전한 결과 온도 및 출력의 실험치는 모사치와 비교하여 양호한 결과를 얻었으며 이 화학열변환기는 일정온도로 승온시킬 수 있는 특징으로 인해 앞으로 산업공정에서 배출되는 폐열원을 활용할 수 있는 시스템으로서의 가능성을 확인하였다.

  • PDF

세라믹 분말을 이용한 오일 기지 나노유체의 열적거동 평가 (Evaluation of Thermal Behavior of Oil-based Nanofluids using Ceramic Nanoparticles)

  • 최철;유현성;오제명
    • 한국전기전자재료학회논문지
    • /
    • 제20권7호
    • /
    • pp.587-593
    • /
    • 2007
  • Oil-based nanofluids were prepared by dispersing spherical and fiber shaped $Al_2O_3$ and AlN nanoparticles in transformer oil. Two hydrophobic surface modification processes using oleic acid (OA) and polyoxyethylene alkyl acid ester (PAAE) were compared in this study. The dispersion stability, viscosity and breakdown voltage of the nanofluids were also characterized. $(Al_2O_3+AlN)$ mixed nanofluid was prepared to take an advantage of the excellent thermal conductivity of AlN and a good convective heat transfer property of fiber shaped $Al_2O_3$. For $(Al_2O_3+AlN)$ particles with 1 % volume fraction in oil, the enhancement of thermal conductivity and convective heat transfer coefficient was nearly 11 % and 30 %, respectively, compared to pure transformer oil. The nanofluid, containing $Al_2O_3+AlN$, successfully lowered the temperature of the heating element and oil itself during a natural convection test using a prototype transformer.

활선중 절연유 분석을 통한 유입변압기 건전성 평가 방법에 관한 연구 (A Study on the Health Evaluation Method of Oil-immersed Transformer through Analysis of Insulating Oil)

  • 신연진;임재용
    • 한국안전학회지
    • /
    • 제38권6호
    • /
    • pp.1-8
    • /
    • 2023
  • The health state of the oil transformer is evaluated by the age of use and the state of internal defects. Mineral Oil, used as an insulator for oil transformers, creates specific gases and compounds through chemical reactions caused by heat, moisture, and partial discharge inside the transformer. It is possible to determine the aging and defect of the transformer through these gases and compounds. So, it is an important indicator to evaluate the health of a transformer. In this study, factors for assessing the health of transformers were hierarchically categorized, and key factors for each hierarchy were selected for design weighting. These weights were determined through surveys conducted with experts in the fields of transformer design, operation, and quality. For the health of a transformer, defect-related factors are approximately three times more important than factors related to aging. Additionally, defect-related factors showed a higher weighting for gases generated at high temperatures. Furthermore, Furan was determined to have a high weight, directly associated with insulating paper aging. Based on these findings, a health index was proposed, and a comparative analysis was conducted by categorizing 40 operational transformers into normal and comparison groups to evaluate and validate it.

전력용 변압기의 온도상승 예측을 위한 전자계-열계 결합해석기법 연구 (A Study of Coupled Electromagnetic-Thermal Field Analysis for Temperature Rise Prediction of Power Transformer)

  • 안현모;김민수;송재성;한성진
    • 전기학회논문지
    • /
    • 제60권10호
    • /
    • pp.1838-1845
    • /
    • 2011
  • This paper deals with coupled electromagnetic-thermal field analysis for thermal fluid analysis of oil immersed power transformer. Electric power losses are calculated from electromagnetic field analysis and are used as input source of thermal field analysis based on computational fluid dynamics(CFD). Particularly, In order to accurately predict the temperature rise in oil immersed power transformer, the thermal problem should be coupled with the electromagnetic problem. Moreover, to reduce analysis region, the heat transfer coefficient is applied to boundary surface of the power transformer model. The coupling method results are compared with the experimental values for verifying the validity of the analysis. The predicted temperature rises show good agreements with the experimental values.

상태감시용 센서를 내장한 배전용 변압기 및 데이터 처리장치 개발 (Development of Distribution Transformer with Condition Monitoring Sensors and Data Processing Unit)

  • 정준홍;유남철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.201_202
    • /
    • 2009
  • This paper presents a design methodology of a distribution transformer with condition monitoring sensors and its data processing unit. The proposed distribution transformer includes various type of condition monitoring sensors such as load current/voltage, temperature and heat aging of insulating oil. The data processing unit is installed at the distribution transformer site. It integrates sensed data and transmits these to a central server system. The proposed distribution transformer and its data processing unit will help an on-line condition monitoring system for distribution transformers.

  • PDF

고효율 나노절연유 제조 및 변압기에의 적용 (Preparation of High-Efficient Oil-based Nanofluids and It's Application to the Transformer)

  • 유현성;최철;오제명
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.31-32
    • /
    • 2007
  • Oil-based nanofluids are prepared by dispersing spherical and fiber-shaped $Al_2O_3$ and AlN nanoparticles in transformer oil. Two hydrophobic surface modification processes are compared in this investigation. It is obvious that the combination of nanoparticle, surfactant and surface modification process is very important for the dispersity of nanofluids. For ($Al_2O_3$+AIN) particles with 1% volume fraction, the enhancement of thermal conductivity and convective heat transfer coefficient is nearly 11% and 30%, respectively, compared to pure transformer oil. The cooling effect of ($Al_2O_3$+AlN)-oil nanofluids on the heating element and oil itself is confirmed by a natural convection test using a prototype transformer.

  • PDF