• 제목/요약/키워드: Heat transfer loss

검색결과 469건 처리시간 0.029초

정적혼합기술 응용 열교환기의 압력손실 및 열전달 특성 (Pressure Loss and Heat Transfer Characteristics of Heat Exchanger Using Static Mixing Technology)

  • 박상규;양희천;전준철
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권1호
    • /
    • pp.65-72
    • /
    • 2006
  • Heat transfer augmentation in heat exchangers has received much attention in recent years, mainly due to energy efficiency and environmental considerations. Many active and Passive techniques are currently being employed in heat exchangers, with some inserts providing a cost-effective and efficient means of augmenting heat transfer. The Purpose of this paper is to determine the pressure loss and heat transfer characteristics of a heat exchanger using static mixing technology. Experimental measurements were taken on two set-ups: a single tube heat exchanger and a shell-tube heat exchanger with two static mixing inserts. It was concluded that the static mixing inserts resulted in an increase in the pressure loss and heat transfer characteristics as can be expected.

마이크로핀관과 평활관에서의 증발열전달과 압력손실 특성 (Evaporation heat transfer and Pressure loss in micro-fin tubes and a smooth tube)

  • 장세환;정시영;홍영기
    • 설비공학논문집
    • /
    • 제11권2호
    • /
    • pp.215-223
    • /
    • 1999
  • Evaporation heat transfer coefficient and pressure loss were measured for three different micro-fin tubes and a smooth tube. The experiments were carried out with R-22 over a wide range of vapor Quality, mass velocity and heat flux. Heat transfer coefficient of the tube with slightly modified fin shape was found to be higher than that of the commercial reference tube by 60%. The improvement of heat transfer has been achieved without noticeable increase of pressure loss. Heat transfer coefficient was increased with increasing quality, refrigerant mass flux, and heat flux. However, the effect of refrigerant mass flux and heat flux was not great. Heat transfer coefficient at bottom was lower than that at top of the tube in low quality region, which suggested the existence of stratification in the micro-fin tube. Pressure drop was linearly increased with increasing refrigerant quality and was proportional to about square of mass flux.

  • PDF

압력 변화 모사를 통한 초소형 연소기에서의 열손실 예측 모텔 개발 (Development of Model for Heat Loss from a Micro Combustor Using Pressure Simulation)

  • 최권형;권세진;이대훈
    • 대한기계학회논문집B
    • /
    • 제27권1호
    • /
    • pp.39-45
    • /
    • 2003
  • As the size of a combustor decreases to a MEMS scale, heat loss increases and becomes a dominant effect on the performance of the devices. Existing models, however, are not adequate to predict the heat transfer and combustion processes in such small scales. In the present study, a semi-empirical model to calculate heat loss from a micro combustor is described. The model derives heat transfer coefficients that best fits the heat loss characteristics of a micro combustor that is represented by transient pressure record after combustion is completed. From conservation of energy equation applied to the burned gas inside the combustor, a relationship between pressure and heat transfer is reduced. Two models for heat transfer coefficients were tested; a constant and first order polynomial of temperature with its coefficients determined from fitting with measurements. The model was tested on a problem of cooling process of burnt gas in a micro combustor and comparison with measurements showed good agreements. The heat transfer coefficients were used for combustion calculation in a micro vessel. The results showed the dependence of flame speed on the scale of the chamber through enhanced heat loss.

수직관내 유리알-물 유동의 압력손실 및 열전달 성능 (Pressure Loss and Heat Transfer Characteristics of the Glass Beads-Water Flow in a Vertical Tube)

  • 김내현;김정식;이윤표
    • 설비공학논문집
    • /
    • 제8권4호
    • /
    • pp.550-560
    • /
    • 1996
  • Recently, fluidized bed heat exchangers with circulating liquid are widely used in a number of places-chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

수직관내 유리알-물 유동의 압력손실 및 열전달 성능 (Pressure Loss and Heat Transfer Characteristics of the Glass Bead - Water Flow in a Vertical Tube)

  • 김내현;김정식;이윤표
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 1996년도 춘계학술발표회 초록집
    • /
    • pp.121-131
    • /
    • 1996
  • Recently, circulating liquid fluidized bed heat exchangers are widely used in a number of places - chemical, process, food concentration, waste water treatment facilities, etc. In a circulating heat exchanger, solid particles circulate with the liquid, thereby increase the heat transfer and reduce the fouling potential of the heat exchanger. In this study, glass beads were circulated through a vertical tube. The pressure loss and the heat transfer coefficient were measured. At low flow velocities, glass beads enhanced the heat transfer considerably. The enhancement increased as the volume fraction of the glass beads increased. It also increased as the particle diameter increased. The pressure loss showed a similar trend. From the observed particle behavior near tube wall, a possible explanation of the trend is provided.

  • PDF

VM열펌프의 2차해석 (A Second-Order Analysis of VM Heat Pumps)

  • 최연석;정은수
    • 설비공학논문집
    • /
    • 제8권2호
    • /
    • pp.208-218
    • /
    • 1996
  • Performance of a VM heat pump is considerably affected by various losses, such as enthalpy dump, reheat loss, pumping loss, conduction loss and shuttle loss. A second-order analysis model of VM heat pumps, which allows consideration of the major losses, was presented. Actual heat transfer rates for heat exchangers were calculated from the heat transfer rates obtained by the adiabatic analysis and various losses. New effective temperatures of heat exchangers were calculated from the actual heat transfer rates and the mean heat transfer coefficients until there was no appreciable change in the effective temperatures. Effects of design parameters, such as phase angle, swept volume ratio, regenerator length and speed on heating capacity, cooling capacity and COP were shown.

  • PDF

엔진 냉각 시스템 개선에 관한 연구 (A Study on Improvement of Engine Cooling System)

  • 김문헌;오병욱
    • 한국자동차공학회논문집
    • /
    • 제2권2호
    • /
    • pp.103-116
    • /
    • 1994
  • In this study the behavior of engine cooling loss and overall heat transfer coefficient were studied experimentally using naturally aspirated engine and turbo charged engine. Using turbo charging, heat dissipation was increased because of the density of the mixture was increased with increment of inlet air flow rate. Therefore, cooling loss of turbo charged engine is larger than naturally aspirated engine. As taking the measurement of surface temperature of combustion chamber, gas heat transfer coefficient was calculated and found that it has greatly affected to overall heat transfer coefficient. The empirical formula of overall heat transfer coefficient established in order to predict of engine cooling loss and express only as a function of mean piston velocity.

  • PDF

구동 조건 변화에 따른 동기 전동기의 성능 손실 및 내부 열전달 특성 (Performance Loss & Heat Transfer Characteristics of Synchronous Motors under Various Driving Conditions)

  • 최문석;엄석기
    • 한국자동차공학회논문집
    • /
    • 제21권3호
    • /
    • pp.165-173
    • /
    • 2013
  • Core loss has a major effect on heat generation in synchronous motors with surface-mounted permanent magnets (SPMs). It is essential to perform heat transfer analysis considering core loss in SPM because core loss is seriously affected by torque and speed of motors. In the present study, mechanical loss, core loss and coil loss are evaluated by measuring input and output energies under various driving conditions. For a better understanding heat transfer paths in synchronous motors, we developed a lumped thermal system analysis model. Subsequently, heat transfer analysis has been performed based on acquired energy loss, temperature data and thermal resistance with three types of SPM. It is shown that the torque constants decrease by Max. 10% as speed increase. At the rated torque, the core loss is Max. 10.9 times greater than the coil loss and the hysteresis loss of magnets is dominant in total loss.

MEMS 로 제작된 마이크로 채널에서의 3 차원 열전달 해석 (3D simulation of Heat transfer in MEMS-based microchannel)

  • 최치웅;허철;김동억;김무환
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.1870-1875
    • /
    • 2007
  • The microchannel heat sink is promising heat dissipation method for high heat flux source. Contrary to conventional circular channel, MEMS based microchannel had rectangular or trapezoidal cross-sectional shape. In our study, we conducted three dimensional conjugate heat transfer calculation for rectangular shape microchannel. First, we simulated that channel was completely drained with known heating power. As a result we obtained calibration line, which indicates heat loss was function of temperature. Second, we simulated single phase heat transfer with various mass flux, 100-400 $kg/m^2s$. In conclusion, the single phase test verified that the present heat loss evaluation method is applicable to micro scale heat transfer devices. Heat fluxes from each side wall shows difference due to non-uniform heating. However those ratios were correlated with supplied total heat. Finally, we proposed effective area correction factor to evaluate appropriate heat flux.

  • PDF

냉장고 가스켓 형상 변화에 따른 냉장고 열손실 저감 효과 (The Effect of Gasket Shape on Heat Loss Reduction in a Refrigeration)

  • 하지수;정광수;김태권;김경호;김석로
    • 설비공학논문집
    • /
    • 제21권5호
    • /
    • pp.305-310
    • /
    • 2009
  • The amount of heat loss of a refrigerator through the gasket is nearly 30% of total refrigerator heat loss. In this paper, quantitative evaluation analysis of heat loss through gasket is established with numerical heat transfer analysis. Extending the gasket shape to protect the heat loss from the gasket, power consumption is measured by using real refrigerator in a temperature and humidity chamber and suggest the gasket shape to reduce the heat loss. From the present result of the numerical simulation of heat transfer and experiment with varying gasket shape, we are able to reduce the heat loss about 20-40% by using extended gasket and the power consumption can be reduced about 5%.