• Title/Summary/Keyword: Heat source length

Search Result 100, Processing Time 0.024 seconds

Ground Air Heat Exchanger Design and Analysis for Air Source Heat Pump (공기열원 히트펌프를 위한 공기식 지중 열교환기(GAHX) 설계 및 분석 연구)

  • Lee, Kwang-Seob;Lyu, Nam-Jin;Kang, Eun-Chul;Lee, Euy-Joon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.12 no.2
    • /
    • pp.1-6
    • /
    • 2016
  • A ground air heat exchanger (GAHX), also called earth air heat exchanger is a useful technology to be integrated with other renewable energy technologies. In this study, ground-air heat exchanger system for the air source heat pump is introduced. The purpose of this study is to design the volumetric flow rate and the length of GAHX system. A GAHX length model equation has been developed and used for calculation. GAHX thermal efficiency are recommended as 75% and 85% in order to optimize pipe length. $2,750m^3/h$, $2,420m^3/h$ of volumetric flow rate on 88.3m, 111.7m length are suggested for providing 7.5kW thermal capacity. And the number of path is recommended more than two to minimize pressure drop. For future study, advanced model equation study with ground thermal behavior and a more efficient GAHX design will be considered.

Natural Convection in a Rectangular Enclosure with Heat Sources at the Bottom (밑면에 열원이 존재하는 밀폐공간에서의 자연대류)

  • Kwon, Y.I.;Kim, S.J.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.3 no.3
    • /
    • pp.197-205
    • /
    • 1991
  • A numerical study has been performed to investigate two dimensional natural convection heat transfer in a rectangular enclosure with heat sources of constant temperature at the bottom. Calculations were made for various dimensionless heat source lengths, W/L=0.1-0.5, and positions of heat sources at $Gr=2.57{\times}10^6$, Pr=0.71 and Ks/Kf=28.98. For various positions of heat sources, the maximum local Nusselt numbers generally show X=0.81-0.85 at the bottom and X=0.23 at the top. For various dimensionless heat source lengths, the maximum local Nusselt numbers at the bottom show W/L=0.4 for one heat source, W/L=0.2 for two heat sources with fixed centers, W/L=0.5 for two heat sources with moved centers. Finally the maximum heat transfer at the bottom exhibits in condition of W/L=0.4 for two heat sources with moved centers.

  • PDF

A Study on the Characteristics of Natural Convection in a Partially Opened Enclosure with a Heat Source (발열체와 부분 열림 수직벽을 갖는 사각 공간내 자연대류 특성 해석)

  • Shim, Dong-Sik;Kang, Bo-Seon;Cha, Dong-Jin;Ju, Won-Jong
    • Proceedings of the KSME Conference
    • /
    • 2000.04b
    • /
    • pp.322-327
    • /
    • 2000
  • Natural convection heat transfer in an enclosure with an opening in the right vertical wall and a heat source at the bottom surface is investigated using a holographic interferometric technique. The effects of the opening length, divider length attached to the top wall, and heater temperature on the temperature distribution are examined. The openging length as well as the divider length greatly affects the degree of inflow and outflow of air. With a small opening, the opening doesn't affect much the upward warm air flow resulting in the symmetric temperature distribution. On the other hand, with the increase of the opening length, the inward cold flow moves the upward flow to the left direction. With the increase of the divider length, temperature in the lower region of enclosure becomes higher for the small opening and lower for the large opening.

  • PDF

A Study on the Characteristics of Natural Convection in a Partially Opened Enclosure with a Heat Source (발열체와 부분 열림 수직벽을 갖는 사각 공간 내 자연대류 특성 해석)

  • Sim, Dong-Sik;Gang, Bo-Seon;Cha, Dong-Jin;Ju, Won-Jong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.24 no.12
    • /
    • pp.1588-1595
    • /
    • 2000
  • Natural convection heat transfer in an enclosure with an opening in the right veritcal wall and a heat source at the bottom surface is investigated using a holographic interferometric technique. The effects of the opening length, divider length attached to the top wall, and heater temperature on the temperature distribution are examined. The opening length as well as the divider length greatly affects the degree of inflow and outflow of air. In the case of small opening length, the opening doesnt affect much the upward warm air flow resulting in the symmetric temperature distribution .The upward flow in hindered by the divider resulting in the decrease of heat transfer from the heater region to the upper region. The longest divider shows the highest temperature in the lower region of enclosure. In the case of large opening length, the inward cold flow moves the upward flow to the left direction. Among the cases of different divider length, the case of H(sub)d=0.25H shows the highest temperature in the lower region of enclosure.

Laser Preheating Method for Three-Dimensional Laser Assisted Milling (3차원 레이저 보조 밀링을 위한 레이저 예열 방법에 관한 연구)

  • Oh, Won-Jung;Lee, Choon-Man
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.32 no.12
    • /
    • pp.1031-1037
    • /
    • 2015
  • Laser assisted machining (LAM) is an effective method with which to effectively process difficult-to-cut materials. Simple machining processes, such as turning and linear tool paths, have been studied by many researchers. But, there are few research efforts on LAM workpieces using threedimensional shapes because of difficulties controlling the laser heat on workpieces with inclined angles or curved surfaces. Two methods for machining three-dimensional workpieces are proposed in this paper. The first is that the heat source shape and laser focal length are maintained using an index table. Second, a rotary type laser module is controlled using an algorithm to move the laser heat source in all directions. This algorithm was developed to control the rotary type laser module and the machine tool simultaneously. These methods are verified by a CATIA simulation.

Operating characteristics of a heat pipe with two heat sources (두개의 열원이 부착된 히트파이프의 동작 특성)

  • Park, Jong-Heung;No, Hong-Gu;Lee, Jae-Heon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.3
    • /
    • pp.303-315
    • /
    • 1998
  • Numerical and experimental studies on a heat pipe with two heat sources have been performed to investigate the operating characteristics. Numerical analysis was performed based on the cylindrical two-dimensional incompressible laminar flow for the vapor space and the conjugate heat transfer for the entire heat pipe. Experimental study with a 0.45 m length copper-water heat pipe was also performed to validate the numerical modeling for the heat input range from 29 W to 47 W on each heater. As results, the temperature profiles at the outer wall for the single active heat source as well as the temperature profiles for the switching operation between two heat sources are suggested. Due to the axial conduction, it is found that the temperature drop between the evaporator and the condenser appears small when the heat source closer to the condenser is turned on. For the switching operation in the present study, the transient time is about 700s and the temperatures at the locations of both heat source are same in 130s after switching.

A Study on Horizontal Ground Source Heat Pump Systems (수평형 지열원 히트펌프 시스템에 관한 연구)

  • Park, Yong-Jung;Kim, Kyoung-Hoon
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.160-165
    • /
    • 2006
  • Ground source heat pump (GSHP) or geothermal heat pump systems (GHPs) are recognized to be outstanding heating and cooling systems. Most of GSHP systems installed and studied in korea are vertical GSHP systems. A horizontal GSHP system was installed in greenhouse and investigated for the performance characteristics. The results of the study showed that the heating coefficient of performance of the heat pump was 3.64 and the overall heating coefficient of performance of the system was 3.31. The pumping power was obtained as 28.0 W/kW and the required ground heat exchanger length was 53.3 m/kW of rejection heat of condenser. The heat extraction rate was, on average, 14.58 W/m of ground heat exchanger length and trench length is 27.7 m/kW of rejection heat of condenser.

Optimization of an Annular Fin with Variable Pipe Inside Radius in the Heat Exchanger of Ground Source System (지열시스템의 열교환기에서 원 관 내부 반경이 변하는 환형 핀의 최적화)

  • Kang, Hyung-Suk
    • New & Renewable Energy
    • /
    • v.5 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Optimization of a rectangular profile annular fin with variable pipe inside radius is presented. This optimum procedure is based on fixed fin height and is made by using variables separation method. The optimum heat loss, corresponding optimum fin length and optimum fin efficiency are presented as a function of pipe inside radius, fin half height, inside fluid convection characteristic number and ambient convection characteristic number. One of results shows that the optimum fin length increases linearly with increase of pipe inside radius for fixed fin height and fin base radius.

  • PDF

Evaluation of Spreading Thermal Resistance in Symmetrical Four-Heat Generating Electronic Components (4개 대칭배열 발열 전자소자에서의 확산 열저항 산정)

  • Kim Yun-Ho;Kim Seo-Young;Rhee Gwang-Hoon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.8
    • /
    • pp.664-671
    • /
    • 2006
  • We propose the correlation to predict the spreading thermal resistance on a plate with symmetrical four heat sources. The correlation transforms four heat sources to a single equivalent heat source and then the spreading thermal resistance can be obtained with the existing equation for a single heat source. When the four heat sources are mounted on a square base plate, the correlation is expressed as a function of the heat source size, the length of base plate, the plate thermal conductivity and the distance between heat sources. Compared to the results of three-dimensional numerical analysis, the spreading thermal resistance by the proposed correlation is in good agreement within 10 percent accuracy.

Effect of the Design Parameters of Geothermal Heat Exchanger Design Length (설계변수가 수직밀폐형 지중열교환기 설계길이에 미치는 영향)

  • Min, Kyong-Chon;Choi, Jae-Ho
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.7 no.2
    • /
    • pp.10-15
    • /
    • 2011
  • A ground loop heat exchanger for the ground source heat pump system is the core equipment determining the thermal performance and initial cost of the system The length and performance of the heat exchanger is dependent on the ground thermal conductivity, the operation hours, the ground loop diameter, the grout, the ground loop arrangement, the pipe placement and the design temperature. The result of this simulation shows that higher thermal conductivity of grouting materials leads to the decrease length of geothermal heat exchanger from 100.0 to 84.4%.