• Title/Summary/Keyword: Heat room

Search Result 1,161, Processing Time 0.029 seconds

A Study on Bedquilts During Sleeping on Ondol in Winter (겨울철 온돌난방에서의 이불에 관한 연구)

  • Kweon, Soo Ae;Lee, Soon Won
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.2
    • /
    • pp.291-299
    • /
    • 1993
  • In this study, bedclimate was investigated depending on three bedquilts used on ondol in winter. The environmental room condition and the ondol surface temperature were maintained $20{\pm}1^{\circ}C$, $50{\pm}3%R$. H and $30{\pm}1^{\circ}C$, respectively. The materials of the experimental quilts were not different from each other. But the weights of cotton filler were 1.5, 3.0, and 4.5kg for the bedquilts. Two healthy young women were subjected for seven hour's sleep with two replications for this study. The results are as follows. 1) The range of temperature under the mattress was higher($38.5{\sim}43.2^{\circ}C$) than that of the temperature on the mattress($32.4{\sim}37.0^{\circ}C$) or that of the temperature inside the bedquilts($30.2{\sim}34.5^{\circ}C$). The humidity inside the bedquilts was 40~73%R.H. 2) The range of bedclimate which subjects feel comfortable were $33.6{\sim}37.1^{\circ}C$ on the mattress, $30.2{\sim}33.6^{\circ}C$, 42~67%R.H. inside the bedquilts. At this range, the mean skin temperature of the subjects was was $34.7{\sim}35.6^{\circ}C$. 3) When there was heating, the weight of mattress increased due to evaporation by heat from below, while wehght of other bedding increased. 4) The lower limbs are noted to be a good representative for the prediction of the skin temperature during sleep. 5) The thicker the bedquilt, the warmer and more humid the bedquilt, which induce frequent body movement during sleep, hence inferior comfort properties of bedquilts.

  • PDF

Performance Evaluation of the Capillary Tube Radiant Floor Cooling & Heating System (모세유관 바닥복사 냉·난방 시스템의 성능평가)

  • Seo, Yu-jin;Kim, Taeyeon;Leigh, Seung-bok
    • KIEAE Journal
    • /
    • v.12 no.4
    • /
    • pp.89-95
    • /
    • 2012
  • At present, many countries are trying to reduce green gas emissions to mitigate the effects of these gases on climate change. Year after year, there have been efforts to cut energy use for heating and cooling. Heating and cooling systems, common in all forms of housing, are increasing due to the constant supply of new housing resulting from improvements in economic growth and the quality of life. Thus, studies related to the design of cooling and heating systems to improve energy efficiency are expanding. Among the new designs, radiant floor cooling and heating systems which use capillary tubes are becoming viable means of reducing energy use. Radiant floor cooling and heating systems which use capillary tubes are creative and sustainable systems in which cool and hot water is circulated into capillary tube which has small diameter. In this study, the cooling and heating performance of this type of capillary tube system is investigated in an experimental study and a simulation using TRNSYS. The results of the experimental study show that under a peak load, a capillary tube radiant floor cooling system using geothermal energy can achieve desired indoor temperature without an additional heat source. The set room air temperature is maintained while the floor surface temperature, PMV and PPD remain within the comfort range. Also, this system is more economic than a packaged air conditioner system due to its higher COP. The results of the simulation show that the capillary tube radiant floor heating system maintains set temperature more stable than a PB pipe radiant floor heating system due to its lower supply temperature of hot water. In terms of energy consumption, the capillary tube radiant floor heating system is more efficient than the PB pipe radiant floor heating system.

Evaluation of Toughness Degradation of 1Cr-1Mo-0.25V Steel by Electrical Resistivity (전기비저항을 이용한 1Cr-1Mo-0.25V강의 인성열화도 평가)

  • Nahm, S.H.;Yu, K.M.;Kim, A.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.18 no.1
    • /
    • pp.10-16
    • /
    • 1998
  • Remaining life of turbine rotors with a crack can be assessed by the fracture toughness of the aged rotors at service temperature. DC potential drop measurement system was constructed in order to evaluate material toughness nondestructively. Test material was 1Cr-1Mo-0.25V steel used widely for turbine rotor material. Seven kinds of specimen with different degradation levels were prepared according to isothermal aging heat treatment at $630^{\circ}C$. Electrical resistivity of test material was measured at room temperature. It was observed that material toughness and electrical resistivity decreased with the increase of degradation. The relationship between fracture toughness and electrical resistivity was investigated. Fracture toughness of a test material may be determined nondestructively by electrical resistivity.

  • PDF

The PTCR Characteristics of the Laminated SMD-Type PTC Thermistor as a Function of the Heat Treatment Conditions (적층 SMD형 PTC 써미스터의 열처리 조건에 따른 PTCR 특성 변화)

  • Lee, Mi-Jai;Jang, Jae-Woon;Lim, Tae-Young;Park, Seong-Chul;Song, Jun-Baek;Han, Cheong-Hwa
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.5
    • /
    • pp.432-437
    • /
    • 2012
  • Electrical properties of the laminated SMD-type PTC thermistor for microcircuit protection were investigated as a function of calcination and sintering temperature. $BaTiO_3$ with $Y_2O_3$ and $MnO_2$ were calcined at 1000 to $1150^{\circ}C$ for 2h and the laminated SMD-type PTC thermistor was sintered at 1350 to $1400^{\circ}C$ for 2h in a reduced atmosphere (1% $H_2/N_2$). Sintered density of the sample was dependent on the calcination and sintering temperature. Electrical properties of the sintered samples were strongly dependent on the densities of samples. For the samples with density below 4.6 g/$cm^3$, the insulator characteristics were observed, while PTC jump characteristics (R150/R30) were disappeared for the sample with density above 5.05 g/$m^3$. Optimal PTC characteristics were obtained for the sintered samples with density of 5.05 g/$m^3$. The laminated SMD-type PTC thermistor prepared by calcination at $1100^{\circ}C$ for 2h and sintering at $1270^{\circ}C$ for 2h showed the room temperature resistivity of $11{\Omega}{\cdot}cm$ and PTC jump characteristics of $10^2$ order.

Noise Analysis and Reduction Methods of the All-in One Window Ventilation System (창호일체형 환기장치의 소음분석 및 저감방안)

  • Park, Chan-Jae;Haan, Chan-Hoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.32 no.1
    • /
    • pp.43-55
    • /
    • 2013
  • The window ventilation system based on the heat recovery device was developed which make air ventilation possible without opening the windows. However, mechanical and aerodynamic noises were come to pass which annoyed people in rooms. In the present study, noise of new window ventilation system was measured in both general room and anechoic chamber. Also, the noise path was detected to find cause of noise generation and vulnerable area of the device. Sound absorptive and insulation materials were applied to mitigate the noise. Finally, an alternative noise control method was suggested which can satisfy with the indoor noise standards. As a result, it was shown that the cause of noise was the low transmission loss in the ventilation system. As a result, it was shown that the main noise source of the ventilation system was the blower and the major cause of noise was the low transmission loss of the ventilation system. It is also concluded that the noise levels complies with the noise standards of 40 dBA when 2 mm rubber sheet is applied inside the ventilation system.

Change of Mechanical Properties of Injection-Molded Glass-Fiber-Reinforced Plastic (GFRP) According to Temperature and Water Absorption for Vehicle Weight Reduction (차량 경량화를 위한 사출성형 유리섬유강화플라스틱의 온도 및 수분 흡수에 따른 기계적 물성 변화)

  • Chun, Doo-Man;Ahn, Sung-Hoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.2
    • /
    • pp.199-204
    • /
    • 2013
  • Owing to the global energy crisis, studies have strongly focused on realizing energy savings through vehicle weight reduction using light metal alloys or polymer composites. Polymer composites afford many advantages including enabling the fabrication of complex shapes by injection molding, and glass and carbon fibers offer improved mechanical properties. However, the high temperature in an engine room and the high humidity during the rainy season can degrade the mechanical properties of the polymer. In this study, the mechanical properties of injection-molded glass-fiber-reinforced polymer were assessed at a temperature of $85^{\circ}C$ and the maximum moisture absorption conditions. The result showed a 23% reduction in the maximum tensile strength under high temperature, 30% reduction under maximum moisture absorption, and 70% reduction under both heat and moisture conditions. For material selection during the design process, the effects of high temperature and high humidity should be considered.

A Study on the Isomerization Reactions of Tricyclopentadiene Derivatives Using Aluminum Chloride(AlCl3) Catalyst(I) (알루미늄클로라이드 촉매를 이용한 Tricyclopentadiene 유도체의 이성화 반응 연구(I))

  • Jo, Hyun-Hye;Kwon, Tae-Soo;Park, Chang-Sun;Han, Jeong-Sik
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.16 no.2
    • /
    • pp.17-24
    • /
    • 2012
  • Tetrahydrotricyclopentadiene(below THTCPD) isomer is a good candidate materials for the high performance liquid fuel component because of its high density and heat of combustion value. The object of this study was to find out the proper reaction condition to improve the fluidity of THTCPD which is solid state at room temperature. Therefore, we have carried out isomerization reactions using aluminum chloride in the varying reaction condition such as reaction temperature and solvents. The results showed that when using aluminum chloride catalyst, THTCPD isomerization reaction was more active in the polar halogenated reaction media such as dichloromethane(methylene chloride: MC), 1,2-dichloroethane(ethylene chloride: EC) and chloroform than in non-polar hydrocarbon media such as n-Hexnae and toluene and was effected by reaction temperature variation.

Effect of Manganese Vanadate Formed on the Surface of Spinel Lithium Manganese Oxide Cathode on High Temperature Cycle Life Performance

  • Kim, Jun-Il;Park, Sun-Min;Roh, Kwang Chul;Lee, Jae-Won
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.9
    • /
    • pp.2573-2576
    • /
    • 2013
  • Rate capability and cyclability of $LiMn_2O_4$ should be improved in order to use it as a cathode material of lithium-ion batteries for hybrid-electric-vehicles (HEV). To enhance the rate capability and cyclability of $LiMn_2O_4$, it was coated with $MnV_2O_6$ by a sol-gel method. A $V_2O_5$ sol was prepared by a melt-quenching method and the $LiMn_2O_4$ coated with the sol was heat-treated to obtain the $MnV_2O_6$ coating layer. Crystal structure and morphology of the samples were examined by X-ray diffraction, SEM and TEM. The electrochemical performances, including cyclability at $60^{\circ}C$, and rate capability of the bare and the coated $LiMn_2O_4$ were measured and compared. Overall, $MnV_2O_6$ coating on $LiMn_2O_4$ improves the cyclability at high temperature and rate capability at room temperature at the cost of discharge capacity. The improvement in cyclability at high temperature and the enhanced rate capability is believed to come from the reduced contact between the electrode, and electrolyte and higher electric conductivity of the coating layer. However, a dramatic decrease in discharge capacity would make it impractical to increase the coating amount above 3 wt %.

An Experimental and Numerical Analysis on Performance Comparison of a Trigeneration Desiccant System and Conventional Air-conditioning System (Trigeneration 제습공조시스템과 일반공조시스템의 성능 비교 실험 및 수치해석)

  • Kim, Hyoung-Tae;Chae, Jungmin;Cho, Young-Ah;Park, So-jin;Song, Geun-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.32-37
    • /
    • 2018
  • Recently, the distributed power generation market using natural gas is expected to expand gradually according to the government's future energy conversion policy. Distributed power generation means small power generation source near the power demand site, which has the advantage of reducing the construction costs of the transmission and distribution infrastructure, operating cost and power loss. A typical example of distributed generation using natural gas is the trigeneration system. In this study, we conducted a basic study on the performance analysis of trigeneration desiccant system for dehumidifying / cooling / heating in the air conditioner room by using the cold and engine waste heat energy generated in the trigeneration system. It shows that the system efficiency increases and the energy consumption decreases as the temperature difference between the inlet and outlet of the trigeneration system increases compared with the general air conditioning system.

Developing of Functional Sport Underpants using Infrared Thermal Image Analysis (열적외선 영상분석을 이용한 기능성 스포츠 팬티 개발)

  • Lee, Joong-Sook;Yang, Jeong-Ok;Lee, Bom-Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.25 no.2
    • /
    • pp.231-240
    • /
    • 2015
  • Objective : This study is for providing data about men's functional sport underpants. It provides the fundamental data of biomechanics by measuring and analyzing the functionality of various underpants using infrared thermal image camera. Method : Then author drew a conclusion based on the final analysis of 965 questionnaire survey results about issues on men's functional sport underpants after discarding invalid questionnaires, as following. Change in body temperature while wearing functional underpants compared to general briefs or boxer pants showed lower temperature by approximately 1~2 degrees Celsius. In the case of general underpants, wearer sweats and feels hotter due to the friction of penis, scrotum and thigh. However functional sport functional underpants improved this issue with ergonomic 3D design by putting penis towards the lower part of the abdomen(below the navel) while putting the scrotum comfortably on the testicles, which enables to make room between the penis, scrotum and thigh of a wearer. Results : This was analyzed to lower the temperature of penis and scrotum. The survey results about the quality of functional underpants showed that 78% of the respondents felt comfortable while driving; 68.5% replied that frictional heat decreased while working out; 78.7% felt less sweat and humidity; 81.7% replied as highly wearable and comfortable; 77.1% replied functional sport underpants were the most comfortable in routine lives or in workout times. Putting all such results together, it is possible to conclude that functional sport is an excellent product. Conclusion : This can be evaluated as an excellent functional sport underpants, towards the penis abdomen (under the navel) in 3D human engineering design, by the scrotum to wearing to be easier to scrotum of pocket, the penis and scrotum and thighs were separated and analyzed with a function that will lower the body temperature of the penis and scrotum.