3실형 인버터 열펌프 시스템의 냉방성능 측정 (Cooling Performance Measurement of a 3 Room Type Inverter Heat Pump System)

  • 정광진;최영돈;장효환;송재복;박윤철
    • 설비공학논문집
    • /
    • 제13권6호
    • /
    • pp.431-439
    • /
    • 2001
  • Recently, multi-room type heat pump system has aroused much attention, because it can achieve much reduction of installation cost and space as well as energy saving in companion with the single room type heat pump system. In the present study, performance characteristics of a 3 room type inverter driven heat pump system, which is widely spread in Japanese market, are measured.. In the single room operation, performances of a heat pump system such s the difference of compressor outlet and inlet pressures and the mass flowrate may increase with the increase of cooling capacity so that COP of the system decrease with the increase of cooling capacity. However, in the 2 room operation, mass flowrate and COP of the total system increase markedly as compared with the single room operation.

  • PDF

환기구를 가진 실내공간에서 복사 및 대류열전달의 비교 연구 (The Comparison Study of Radiative and Convective Heat Transfer in a Room Air Ventilation)

  • 정효민;정한식;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제21권3호
    • /
    • pp.229-235
    • /
    • 1997
  • The comparison of radiative and convective heat transfer in a room air ventilation is investi¬gated by a numerical simulation. The room air temperature distributions with radiation are appeared more uniform than without radiation at Gr= 1460 and Re=50. The mean Nusselt number in the radiative heat transfer shows less value than convective heat transfer. The total mean Nusselt number is found Wall 1> Wall 3${\fallingdotseq}$Wall 2 7 Wall 4.

  • PDF

단열재 개선을 통한 PKG-A Water Jet Room 온도저감 연구 (A Study on the Internal Temperature Reduction of PKG-A Water-jet-room by Substituting Heat Insulation Materials)

  • 정영인;최상민
    • 품질경영학회지
    • /
    • 제47권3호
    • /
    • pp.425-435
    • /
    • 2019
  • Purpose: The purpose of this study was to resolve the Naval ship's Local Operation Panel(LOP) malfunction problems which caused by overheating in summer season and dispatching to equatorial regions. Methods: Instead of using dual type heat insulation materials(consist with ceramic wool and glass wool), aerogel heat insulation materials were used for decreasing heat emissions from gas-turbine heat waste steam pipes passing water-jet- room. Experiment and Computational analysis of heat flow were conducted to analyze the internal room temperature changes. Results: The results of this study are as follows; The aerogel heat insulation materials suppress heat emission more efficiently than dual type insulation materials. The cold surface temperature of insulation was far more decreased and internal room, LOP surface temperature also showed significant results too. Conclusion: The substituted heat insulation materials appeared remarkable performance in decreasing room temperature that it could be used for suppressing the LOP overheatings and malfunctions.

동력객차 동력실 내부의 열유체 유동의 수치 시뮬레이션 (A Numerical Simulation of Heat and Fluid Flow in the Motor Block Room of a Motorized Car)

  • 김학범;허재경;이기열
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.589-594
    • /
    • 1998
  • Heat and fluid flow in the motor block room of a motorized car is numerically simulated. The motorized car, composed of a motor block room and a passenger room, supplies additional Power to achieve the design speed. A motor block, a transformer, and a fan are equipped in the motor block room. Flow phenomena in the ducts on the motor block and power transformer are investigated. Also, the three dimensional heat and fluid flow in the motor block room is simulated to give a qualitative information of the flow characteristics.

  • PDF

온돌난방공간(溫突暖房空間)의 내표면(內表面) 대류열전달특성(對流熱傳達特性)에 관(關)한 연구(硏究) (Convection Heat-Transfer Characteristics of Ondol-Heated Room)

  • 손장열;안병욱
    • 설비공학논문집
    • /
    • 제3권5호
    • /
    • pp.376-385
    • /
    • 1991
  • The purpose of this paper is to propose basic data on convection heat-transfer coefficients in Ondol-heated room. Surface temperatures and several temperatures around each inside surface of wall, floor and ceiling composed of heating room are measured vertically in Ondol-heated model rooms, and the vertical temperature profiles could be expressed by nonlinear equation models. Also, the convection heat transfer phenomena are analysed from the nonlinear equation models. In the results, the convection heat-transfer coefficients of Ondol heated space are suggested by the term of temperature difference between each wall surface and room air temperature and by the relationship between Nusselt number and Rayleigh number of dimensionless numbers.

  • PDF

Effectiveness of Ventilation Control in a Dry Room with a Heat and Moisture Source

  • Lee, Kwan-Soo;Lim, Kwang-Ok;Ahn, Kang-Ho;Jung, Young-Sick
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제9권4호
    • /
    • pp.1-9
    • /
    • 2001
  • The temperature and moisture distributions in a dry room with a heat and moisture source -i.e., workers- are studied numerically by using a standard $k-\varepsilon$ turbulence model. In order to evaluate the effectiveness of heat and moisture ventilation inside the room, the heat removal capacity and the moisture exhaust efficiency are introduced. The effectiveness of ventilation control is analyzed by evaluating the temperature and humidity distributions in the room quantitatively. It is found that the mean absolute humidity inside the room is almost constant regardless of the models and the heat generation rates in this study range. This results from the fact that the moisture generation by the workers was relatively small. Through the modification of the design, 40% improvement in critical decay time was achieved.

  • PDF

데이터센터의 합리적인 환경제어를 위한 장비 발열기준에 대한 연구 (A Study on a Heat-load of IT Equipments for the Thermal Environment Control in the Data Center)

  • 조진균;홍민호;정차수;김병선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2006년도 하계학술발표대회 논문집
    • /
    • pp.938-943
    • /
    • 2006
  • The primary purpose of a computer room of data center and associated infrastructure is to support the operation of critical IT equipment. Traditionally, most owners of large critical data centers have been more than willing to accept a reasonable amount of computer room worker discomfort if necessary to support critical IT systems. All electrical equipment produces heat, which must be removed to prevent the equipment temperature from rising to an unacceptable level. Most information technology equipment and other equipment found in a data center or network room is air-cooled. Sizing a cooling system requires an understanding of the amount of heat produced by the equipment contained in the enclosed space, along with the heat produced by the other heat sources typically encountered.

  • PDF

열펌프-잠열축열시스템을 이용한 온돌의 난방특성 (Heating Characteristics of Ondol using Heat Pump-Latent Heat Storage System)

  • 김명헌;송현갑
    • 태양에너지
    • /
    • 제20권3호
    • /
    • pp.1-9
    • /
    • 2000
  • In these days the hot water circulating Ondol using the fossil fuel boiler is the heating system for the most of the Korean residents. Then it is installed without the heat storage medium in the Ondol heating layer, but the Korean traditional Ondol had been composed with the heat storage medium. The Ondol room without heat storage medium could not be comfortable because the room air temperature is not only changed unstably but also it has a defect too much fuel consumption. Therefore in this study the heat pump-latent heat storage Ondol as the new type of Ondol system was developed to solve these problems mentioned above, and the COP of the heat pump (Coefficient Of Performance), the latent heat storage characteristics in the new type of Ondol system and the temperature variation in the Ondol room with the ambient temperature were analyzed.

  • PDF

일정 열유속의 열원을 갖는 사각공간의 혼합대류 열전달 (Heat transfer of Mixed convection in rectangular space with constant heat flux)

  • 조대환
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제23권4호
    • /
    • pp.552-558
    • /
    • 1999
  • Ventilation of the marine engine room is very important for the health of the workers as well as the normal operation of machines. To find proper ventilation conditions of this engine room numerical simulation with a standard k-$\varepsilon$model was carried out. In the present study the marine engine room is considered as a closed space with a heat source and forced ventilation ducts. The injection angle of air supply is found to be important. Injection with a downward angle depresses recirculation flow causing a strong stream in the wider space of the room Ventilation and removal of the released heat are promoted with this pattern, There is a possibility of local extreme heating at the upper surface of the engine when supply and exhaust ports of air are in bilateral symmetry.

  • PDF

다수의 열원을 가지는 공간에서의 환기 조건에 따른 열환경 해석 (Thermal Environment Analysis of a Room in Accordance with Ventilation Condition with Multi-Heat Sources)

  • 김재중;손영갑;장석원;유동수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집B
    • /
    • pp.199-204
    • /
    • 2000
  • This paper reports a thermal environmental analysis of a room in accommodated with multi-heat sources according to ventilation condition. Two case modification have been investigated to obtain the lower temperature distribution in the room. The temperature distribution of the original room were found about $25{\sim}35^{\circ}C$. As a result, the use of, three ventilating fans and two electric fans are useful for room ventilation respectively, and using two electric fan is more recommendable in side of economical efficiency.

  • PDF