마이크로터빈의 열회수 성능시험 (Test of Heat Recovery Performance of a Microturbine)

  • 전무성;이종준;김동섭;장세동
    • 대한기계학회논문집B
    • /
    • 제32권8호
    • /
    • pp.629-635
    • /
    • 2008
  • Recently, microturbines have received attention as a small-scale distributed power generator. Since the exhaust gas carries all of the heat release, the microturbine CHP (combined heat and power) system is relatively compact and easy to maintain. Generating hot water or steam is usual method of heat recovery from the microturbine. In this work, a heat recovery unit producing hot water was installed at the exhaust side of a 30 kW class microturbine and its performance characteristics following microturbine power variation was investigated. Heat recovery performance has been compared for different operating conditions such as constant hot water temperature and constant water flow rate. In particular, the influence of water flow rate and hot water temperature on the recovered heat was analyzed.

히트파이프를 이용한 온풍난방기 배기열회수 시스템의 열회수 특성 (Heat Recovery Characteristics of the Exhaust Heat Recovery System with Heat Pipe Unit Attached to the Hot Air Heater in the Greenhouse)

  • 강금춘;김영중;유영선;백이;이건중
    • Journal of Biosystems Engineering
    • /
    • 제26권5호
    • /
    • pp.441-448
    • /
    • 2001
  • Hot air heater with light oil combustion is used as the most common heater for greenhouse heating in the winter season. However, exhaust gas heat discharged to atmosphere through chimney reaches up to 10~20% of total heat capacity of the oil burred. In order to recover the heat of this exhaust gas and to use for greenhouse heating, the heat pipe type exhaust heat recovery system was manufactured and tested in this experiment. The system consisted of a heat exchanger made of heat pipes, ø15.88${\times}$600mm located in the rectangular box of 675(L)${\times}$425(W)${\times}$370(H)mm, an air suction fan and air ducts. The number of heat pipe was 60, calculated considering the heat exchange amount between exhaust gas and air and heat transfer capacity of a heat pipe. The working fluid of heat pipe was acetone because acetone is known for its excellent heat transfer capacity. The system was attached to the exhaust gas path. According to the performance test it could recover 53,809 to 74,613kJ/h depending on the inlet air temperature of 12 to -12˚at air flow rate of 1.100㎥/h. The temperature of the exhaust gas left the heat exchanger dropped to 100$^{\circ}C$ from 270$^{\circ}C$ after the heat exchange between the suction air and the exhaust gas.

  • PDF

전열교환 환기시스템의 외기변화에 따른 성능평가 및 에너지평가를 통한 운전방안에 관한 연구 (A Study on Operating Method by Energy Evaluation and Performance Evaluation of Heat Recovery Ventilator According to Outdoor Conditions)

  • 김광현;이정재
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.57-64
    • /
    • 2008
  • Recently, regulation of ventilator installation and its details has been revised and the establishment of heat recovery ventilator in newly built apartments has been obligated. This study was done to offer the method of operation and design of heat recovery ventilator to save energy by measuring its efficiency and comparing with the results of experiment. This paper confirmed that it is desirable to operate heat recovery ventilator by using "by-pass mode" within $60{\sim}80%$ scope of the difference indoor absolute humidity in spring and autumn and outdoor absolute humidity and heat recovery ventilator of energy saving effect is better than constant air volume system.

전열교환기가 설치된 기류전환형 히트펌프의 동계운전성능에 관한 실험적 연구 (An Experimental Study on the Operating Performance of an Air Shift type Heat Pump with Heat Exchanger)

  • 장영근
    • 설비공학논문집
    • /
    • 제22권8호
    • /
    • pp.567-572
    • /
    • 2010
  • Air shift type heat pump is combined heat recovery ventilator and refrigerator, and it is installed an air shifter changing air flow. And so it is an perfect AHU(Air Handling Unit) capable to cooling, heating, ventilation and heat recovery. Therefore, an experimental study has been carried out to investigate the operating performance in winter for this system. An experimental data are room temperature, inlet/outlet temperature of condenser, evaporator and heat exchanger. They have been measured as the variation of outdoor temperature. The results, in case of rising above freezing, the air shift type heat pump system is operated normally, and the heating COP is 3.0~4.2 by varying outdoor temperature from $-3^{\circ}C$ to $15^{\circ}C$.

반도체 클린룸용 외기공조시스템의 수분무 가습을 이용한 에너지절감에 관한 연구 (A Study on Energy Reduction in an Outdoor Air Conditioning System for Semiconductor Manufacturing Cleanrooms Using Water Spray Humidification)

  • 송원일;김기철;유경훈;신대건;태경응;김용식;박덕준
    • 한국입자에어로졸학회지
    • /
    • 제13권2호
    • /
    • pp.65-77
    • /
    • 2017
  • In recent large-scale semiconductor manufacturing cleanrooms, the energy consumption in outdoor air conditioning (OAC) systems to heat, humidify, cool and dehumidify outdoor air(OA) represents about 40~50 % of the total cleanroom power consumption required to maintain cleanroom environment. Therefore, the assessment of energy consumption in outdoor air conditioning systems is essential for reducing the outdoor air conditioning load for a cleanroom. In the present study, an experiment with an outdoor air flow rate of $1,000m^3/h$ was conducted to compare the energy consumption in steam humidification, simple air washer, exhaust air heat recovery type air washer and dry cooling coil(DCC) return water heat recovery type air washer OAC systems. Besides, a numerical analysis was carried out to evaluate the annual energy consumption of the aforementioned four OAC systems. It was shown that the simple air washer, exhaust air heat recovery type air washer and DCC return water heat recovery type air washer OAC systems using water spray humidification were more energy-efficient than the steam humidification OAC system. Furthermore the DCC return water heat recovery type air washer OAC system was the most energy-efficient.

반도체 클린룸용 배기 열회수식 에어와셔 시스템의 에너지절감에 관한 수치해석 (Numerical Analysis on Energy Reduction of an Exhaust-Air-Heat-Recovery Type Air Washer System for Semiconductor Manufacturing Clean Rooms)

  • 송근수;김형태;유경훈;손승우;신대건;김영일
    • 설비공학논문집
    • /
    • 제22권10호
    • /
    • pp.697-703
    • /
    • 2010
  • In recent semiconductor manufacturing clean rooms, air washers are used to remove airborne gaseous contaminants from the outdoor air introduced into a clean room. Meanwhile, there is a large amount of exhaust air from a clean room. From an energy conservation point of view, heat recovery is useful for reducing the outdoor air conditioning load required to maintain a clean room. Therefore it is desirable to recover heat from the exhaust air and use it to cool or heat the outdoor air. In the present study, numerical analysis was conducted to evaluate the recovered heat of an exhaust air heat recovery type air washer system, which is the key part of an energy saving outdoor air conditioning system for semiconductor clean rooms. The present numerical results showed relatively good agreement with the available experimental data.

300 kW급 소형 열병합발전기용 배열회수 시스템의 실증운전 성능분석에 관한 연구 (Observation Studies on Field Operation of a Exhausted Heat Recovery System for a 300 kW Class Small Gas Engine Cogeneration System)

  • 김민성;백영진;박성룡;나호상
    • 설비공학논문집
    • /
    • 제22권4호
    • /
    • pp.248-257
    • /
    • 2010
  • An exhausted heat recovery system for a small gas engine cogeneration plant was investigated. The system was designed and built in a 300 kW class cogeneration demonstrative system. The basic performance was tested depending on load variation, and installed to a field site as a bottoming heat and power supply system. The exhaust gas heat exchangers (EGHXs) in shell-and-tube type and shell-and-plate type were tested. The entire efficiency of the cogeneration system was estimated between 85 to 90% under the 100% load condition, of which trend appears higher in summer due to the less thermal loss than in winter. Power generation efficiency and thermal efficiency was measured in a range of 31~33% and 54~57%, respectively.

R245fa 냉매를 이용한 배열회수 히트펌프 시스템 성능에 관한 실험적 연구 (Experimental Study on the Performance of Heat Recovery Heat Pump System using R245fa Refrigerant)

  • 김현택;김용찬;차동안;권오경
    • 설비공학논문집
    • /
    • 제28권10호
    • /
    • pp.408-413
    • /
    • 2016
  • The objective of this study is to investigate the performance of a heat recovery heat pump dryer using a R245fa refrigerant experimentally. In this study, the main components of the heat pump dryer were an evaporator, a compressor, a condenser, and an expansion valve. As a result, when the amount of refrigerant varied from 15 kg to 16 kg, the hot air outlet temperature in the condenser and the heat transfer rate were almost kept constant. Therefore, the amount of refrigerant at 16 kg was considered to be a suitable amount in the heat pump. As the air inlet velocity varied from 0.5 m/s to 1.5 m/s, the highest temperature in the condenser could be obtained when the air inlet velocity was 0.5 m/s. The heat transfer rate, system (COP), and hot air outlet temperature were 5.6 kW, 3.4, and $102.5^{\circ}C$, respectively, when the bypass ratio and water temperature were 0% and $60^{\circ}C$.

창호통합형 배열회수 환기시스템의 열성능 및 경제성 평가 (An Analysis on Thermal Performance and Economic of Heat Recovery Ventilation System Integrated with Window)

  • 성욱주;조수;송규동
    • 설비공학논문집
    • /
    • 제24권8호
    • /
    • pp.646-655
    • /
    • 2012
  • This study is intended to analyze the thermal performance and evaluate the applicability about non-duct type heat recovery ventilation system integrated with window. Eventually, economic analysis of the system is conducted according to building energy saving ratio of it. As results of the thermal performance, the U-factor of the window conducted on the basis of KS F 2278 appears to $1.8W/m^2K$, and the effective heat exchange efficiency of the ventilator conducted on the basis of KS B 6879 appears 49.95% for cooling, 66.89% for heating. In the applicability evaluated by TRNSYS 16, the caes of applying the heat recovery ventilator integrated with window is found to reduce the cooling or heating load by 2.9% or 13.5% than the non-ventilator case. The results of economic analysis taking a side of consumer is verified as the payback is 3 years, and the accumulated earning is 1,408,133 won in terms of '600,000 won/unit' for initial cost, 10 years for useful life of the system.

30,000CMH급 폐열회수열교환기 겨울철 성능실험 결과 (Experiment Results of 30,000 CMH class Heat Exchangers for Wasted Heat Recovery in Winter)

  • 하병용;임홍석;김동규;금종수;정석권;정용현;김근오;명진필
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.83-86
    • /
    • 2009
  • The field of the large volume heat exchanger for wasted heat recovery ventilation system is being expanded enormously seeing as the fact that the quantity of reducing energies are huge due to the large volume heat exchanger for wasted heat recovery system at large buildings and factories, which consume large amount of energies while it has been arising huge amount of losses in Korea because of the lack of technology.