• Title/Summary/Keyword: Heat pipe heat exchanger

Search Result 239, Processing Time 0.027 seconds

Analysis of Pressure Drop for Combining Junctions in Gas-Liquid Two-Phase Flows (기액 2상 유동에서 합지관에서의 압력강하에 대한 해석)

  • 김철환;하삼철;김은필;김경천
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.9
    • /
    • pp.870-878
    • /
    • 2000
  • An experimental study and a modeling are peformed to investigate the pressure drop of combining junctions in two-phase flows. Experiments on tripod geometry used in a condenser or an evaporator, are conducted with inlet mass fluxes from 200 to$ 400 kg/m^2$s, and pipe diameters of 7 m and 9.52 m. The working fluid is R22. The result shows that the pressure drop increases as the quality does, but the effect of the increase of the pressure decreases when the diameter of a pipe increases. When the mass flux increases, the pressure drop linearly does. Furthermore, when the pipe diameter decreases, the pressure drop has a quadratic increase.

  • PDF

Performance of Heat Pump Water Heater with Dual Condenser (2단 응축 히트펌프 온수시스템의 사이클 해석 및 성능분석)

  • Ryou, Y.S.;Kim, Y.J.;Kang, G.C.;Paek, Y.;Yun, J.H.;Kang, Y.G.;Lee, H.M.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.423-429
    • /
    • 2006
  • The heat pump water heater developed in this research consisted of one evaporator, one compressor, 1st condenser, 2nd condenser, one expansion valve, one water tank, one recirculation circuit and etc. The performance of heat pump water heater was tested and analyzed. The quantities of output water changed linearly from 2380 to $660{\ell}/h$, and the output water temperature changed curvedly from 29.9 to $44.5^{\circ}C$ when the opening rate of recirculation valve changed from 0 to 100%. The COP of heat pump water heater increased from 3.0 to 3.8 when the quantities of output water changed from 660 to $2380{\ell}/h$. When the temperature distributions of water tank were measured during 50 minutes after turning on the heat pump, the temperature stratification by the level appeared apparently. When the inlet water temperature changed from 30 to$50^{\circ}C$, the output energy of heat pump hardly changed. The surface area of double pipe heat exchanger changed from 0.429 to $6.254m^2$ when the compressor capacity increased from 1.0 to 50.0 PS.

Heat Pipe Heat Exchanger (히트파이프 열교환기)

  • 이영수;이기우
    • Journal of the KSME
    • /
    • v.35 no.9
    • /
    • pp.805-815
    • /
    • 1995
  • 히트파이프에 관한 연구는 구미, 일본 등 선진 각국뿐만 아니라, 중국, 독립국가연합 및 동구권 에서도 다년간 활발하게 진행되어 왔다. 석유파동 이후 에너지 절약을 위한 노력의 결과로 폐 열회수 장치가 많이 개발되면서 히트파이프를 전열소자로 사용한 폐열회수 장치가 상당히 늘어나 이에 소요되는 히트파이프의 생산량도 급격한 신장세를 나타내고 있다. 이는 히트파이프 자체가 응답성이 좋고, 구조가 간단하며, 전열성이 뛰어난 장점으로 인하여 많은 연구가 이루어졌기 때 문이라 하겠다.그 응용분야는 인공위성으로부터 폐열회수용 열교환기, 전기장치 전자소자의 냉각, 음향기기의 냉각, 태양열과 지열의 유효이용, 플라스틱 금형의 냉각, 공작기계의 주축냉각, 포장 기계, 주방기기, 전력케이블의 냉각, 엔진 및 브레이크의 냉각 등 응용분야가 광범위하여 급격 하게 발전하고 있다. 그러나 국내에서는 히트파이프와 관련된 학술적인 연구결과가 발표되고 있을 뿐, 체계적이며 지속적인 연구가 수행되지 못하고 있다. 또한 산업계에서도 관련제품의 대 부분을 수입에 의존하고 있으며, 일부 제작업체에서는 제품이 나오고 있으나 축적기술결여로 그 성능면에 있어서 보증이 어려워 업계의 연구개발에 대한 노력이 절실히 요구되고 있다.

  • PDF

Development of a Commercial-scale RDF Boiler with Chain type Stoker (실증규모 체인스토커식 RDF전용보일러 개발)

  • Choi, Yeon-Seok;Kim, Byung-Gil;Roh, Nam-Sun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2009.06a
    • /
    • pp.813-816
    • /
    • 2009
  • A commercial-scale RDF boiler that its burning capacity is 400 kg-RDF/hr and steam production capacity is 2 ton/hr. It has a chain type stoker and waste heat recovery system. Heat exchanger is vertical water-pipe so that soot blowing and removal is convenient during operation. Dry scrubber, bag filter and activated carbon tower have been installed for the reduction of air pollutant gases and dust. Analysing data of pollutants from stack such as $SO_x$. $NO_x$ and dioxin shows so good results that the boiler system could comply the regulated emission limits.

  • PDF

Study on Condensing Pressure Drop of Hydrocarbon Refrigerants (탄화수소계 냉매의 응축 압력강하에 관한 연구)

  • Kim, Jae-Dol;Choi, Jun-Hyuk;Jeong, Seok-Kwon;Yoon, Jung-In;Lee, Ho-Saeng
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.218-224
    • /
    • 2006
  • Experimental results for pressure gradient of HCs refrigerants R-290. R-600a. R-1270 and HCFC refrigerant R-22 during condensing inside horizontal double pipe heat exchangers are presented. The test sections which have the tube inner diameter of 10.98mm. and the tube inner diameter of 8mm are used for this investigation. Hydrocarbon refrigerants have higher pressure drop than R-22 in both test sections with the diameters of 12.70mm and 9.52mm. Pressure drop increased with the increase of the mass flux. These results form the investigation can be used in the design of heat transfer exchanger using hydrocarbons as the refrigerant for the air-conditioning systems

Development of risk assessment framework and the case study for a spent fuel pool of a nuclear power plant

  • Choi, Jintae;Seok, Ho
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1127-1133
    • /
    • 2021
  • A Spent Fuel Pool (SFP) is designed to store spent fuel assemblies in the pool. And, a SFP cooling and cleanup system cools the SFP coolant through a heat exchanger which exchanges heat with component cooling water. If the cooling system fails or interfacing pipe (e.g., suction or discharge pipe) breaks, the cooling function may be lost, probably leading to fuel damage. In order to prevent such an incident, it is required to properly cool the spent fuel assemblies in the SFP by either recovering the cooling system or injecting water into the SFP. Probabilistic safety assessment (PSA) is a good tool to assess the SFP risk when an initiating event for the SFP occurs. Since PSA has been focused on reactor-side so far, it is required to study on the framework of PSA approach for SFP and identify the key factors in terms of fuel damage frequency (FDF) through a case study. In this study, therefore, a case study of SFP-PSA on the basis of design information of APR-1400 has been conducted quantitatively, and several sensitivity analyses have been conducted to understand the impact of the key factors on FDF.

Evaluation of Heat Exchange Rate in Horizontal Slinky and Coil Type Ground Heat Exchangers Considering Pitch Interval (피치 간격에 따른 수평 슬링키형과 코일형 지중 열교환기의 열효율 평가)

  • Yoon, Seok;Lee, Seung-Rae;Kim, Min-Jun;Kim, Woo-Jin;Go, Gyu-Hyun;Jeon, Jun-Seo
    • Journal of the Korean Geotechnical Society
    • /
    • v.30 no.7
    • /
    • pp.55-61
    • /
    • 2014
  • The need of geothermal energy is constantly increasing for economical and environmental utilization. Horizontal ground heat exchangers (GHEs) can reduce installation cost and increase efficiency. There are many kinds of GHEs, and it is known that slinky and spiral coil type GHEs show high thermal performance. Therefore, this paper presents experimental results of heat exchange rates in horizontal slinky and spiral coil type GHEs installed in a steel box whose size is $5m{\times}1m{\times}1m$. Dried Joomunjin standard sand was filled in a steel box, and thermal response tests (TRTs) were conducted for 30 hours to evaluate heat exchange rates by changing different pitch spaces of horizontal slinky and spiral coil type GHEs. As a result, spiral coil type GHE showed 30~40% higher heat exchange rates per pipe length than horizontal slinky type GHEs. Furthermore, long pitch interval (Pitch/Diameter=1) showed 200~250% higher heat exchange rates per pipe length than short pitch interval (Pitch/Diameter=0.2) in both spiral coil and horizontal slinky type GHEs, respectively.

Performance Characteristics of Refrigeration and Air Conditioning System Using Hydrocarbon Refrigerants (탄화수소계 냉동공조 시스템의 성능특성에 관한 실험)

  • 이호생;이근태;김재돌;윤정인
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.28 no.5
    • /
    • pp.728-734
    • /
    • 2004
  • Environmentally friendly refrigerants with zero ozone layer depletion potential are required to be used in refrigerators and air conditioners due to the difficulties related to ozone layer depletion and global warming. A rigorous study for the system performance with new refrigerants having zero ozone layer depletion potential is inevitable before adopting that as a new fluid. The HFC(Hydrofluorocarbon) potential has been recommended as alternatives. In this paper. system performance in the heat pump facilities were studied using R-290, R-600a. R-1270 as an environment friendly refrigerant. R-22 as a HCFC's refrigerant. The experimental apparatus has been set-up as a conventional vapor compression type heat Pump system. The test section is a horizontal double pipe heat exchanger. A tube diameter of 12.70mm with 1.315mm wall thickness is used for this investigation. The test results showed that the COP of hydrocarbon refrigerants were superior to that of R-22 and the maximum increasing rate of COP was found in R-1270. The refrigeration capacity of hydrocarbon refrigerants were higher than that of R-22. The compressor work was obtained with the maximum value in R-1270 and the minimum one in R-22.

The development of ultrasonic transmitter to enhance the efficiency of heat transfer rate in boiler (보일러내 열 전달 효율 개선을 위한 초음파발신기 개발)

  • Heo, Pil-Woo;Lee, Yang-Lae;Lim, Eui-Su;Koh, Kwang-Sik
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.95-101
    • /
    • 2003
  • Ultrasonic transmitter used for scale prevention in boiler or heat exchanger is composed of the magnetostrictive material which transforms electric energy into ultrasonic wave and the horn which amplifies generated ultrasonic wave and transfers it into medium loaded. In this paper, we have performed the shape design for magnetostrictive material and analyzed a few type of horns which amplify generated ultrasonic wave and found each solution theoretically. Final length of the horn has been determined by measuring the sound pressure in medium between theoretical value and experience data. At last we have given the results of our study for the effects of ultrasonic wave irradiated by manufactured ultrasonic transmitter on preventing scale deposition on test pipe under the similar condition to boiler.

Experimental Study on Drag Reduction Effects of New Non-Ionic Surfactants

  • Tae, Choon-Sub;Cho, Sung-Hwan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.14 no.4
    • /
    • pp.147-155
    • /
    • 2006
  • The drag reduction (DR) and heat transfer efficiency reduction (ER) of non-ionic surfactant were investigated as a function of fluid velocity, temperature, and surfactant concentration. An experimental apparatus consisting of two temperature controlled water storage tanks, pumps, test specimen pipe and the piping network, two flow meters, two pressure gauges, a heat exchanger, and data logging system was built. From the experimental results, it was concluded that existing alkyl ammonium surfactant (CTAC Cethyl Trimethyl Ammonium Chloride) had DR of $0.6{\sim}0.8$ at $1,000{\sim}2,000ppm$ concentration with fluid temperature ranging between $50{\sim}60^{\circ}C$. However, the DR was very low when the fluid temperature was $70{\sim}80^{\circ}C$. The new amine oxide and betaine surfactant(SAOB Stearyl Amine Oxide + Betaine) had lower DR at fluid temperatures ranging between $50{\sim}60^{\circ}C$ compared with CTAC. However, with fluid temperature ranging between $70{\sim}80^{\circ}C$ the DR was $0.6{\sim}0.8$ when the concentration level was $1,000{\sim}2,000ppm$.