• 제목/요약/키워드: Heat pack

검색결과 84건 처리시간 0.027초

하이브리드/전기 자동차 배터리 냉각 시스템의 냉각수 유동 특성이 냉각 성능에 미치는 영향에 대한 해석적 연구 (Effect of Coolant Flow Characteristics in Cooling Plates on the Performance of HEV/EV Battery Cooling Systems)

  • 오현종;박성진
    • 한국자동차공학회논문집
    • /
    • 제22권3호
    • /
    • pp.179-185
    • /
    • 2014
  • Average temperature and temperature uniformity in a battery cell are the important criteria of the thermal management of the battery pack for hybrid electric vehicles and electric vehicles (HEVs and EVs) because high power with large size cell is used for the battery pack. Thus, liquid cooling system is generally applied for the HEV/EV battery pack. The liquid cooling system is made of multiple cooling plates with coolant flow paths. The cooling plates are inserted between the battery cells to reject the heat from batteries to coolant. In this study, the cooling plate with U-shaped coolant flow paths is considered to evaluate the effects of coolant flow condition on the cooling performance of the system. The counter flow and parallel flow set up is compared and the effect of flow rate is evaluated using CFD tool (FLUENT). The number of counter-flows and flow rate are changed and the effect on the cooling performance including average temperature, differential temperature, and standard deviation of temperature are investigated. The results show that the parallel flow has better cooling performance compared with counter flow and it is also found that the coolant flow rate should be chosen with the consideration of trade-off between the cooling performance and pressure drop.

고속 충전을 위한 이차전지모듈 냉각시스템 기술 개발 (Development of Secondary Battery Module Cooling System Technology for Fast Charging)

  • 강석준;김미주;성동길;오미영;배준수
    • 전기화학회지
    • /
    • 제25권3호
    • /
    • pp.119-124
    • /
    • 2022
  • 하이브리드 자동차 및 전기 자동차(하이브리드 및 전기자동차)용 배터리 팩은 고용량 대면적 셀을 적용하기 때문에 배터리 셀의 평균 온도는 중요한 관리 기준이 된다. 최근에는, 배터리 충전시간을 줄이기 위한 고속 충전 기술이 요구되고 있으며, 이에 따른 셀과 전장부품의 발열로 인해 배터리 팩 성능 및 수명의 저하가 발생한다. 따라서, 고속 충전에 따른 배터리 팩의 성능저하를 방지하기 위해 효과적인 배터리 냉각시스템이 필요하다. 본 연구에서는 파우치형 고속 충전용 배터리 셀 적용 냉각시스템 및 모듈 설계를 도출하고 배터리의 효율을 극대화할 수 있는 냉각성능을 분석하였다. 베이퍼챔버 냉각시스템을 적용한 모듈의 온도 편차 분석 결과 모듈 내 온도 편차는 5.82 ℃로 기존 알루미늄 냉각판 대비 낮은 온도를 보여 우수한 냉각시스템 효과를 보였다.

측정부 온도 부하에 따른 광용적맥파 파형 요동 특성 분석 (Analysis for the Fluctuation of the Photoplethysmographic Waveform derived by Temperature Stress of Measuring Position)

  • 이충근;신항식
    • 전기학회논문지
    • /
    • 제64권2호
    • /
    • pp.304-309
    • /
    • 2015
  • Applicable range of Photoplethysmography (PPG) becomes wider as a non-invasive physiological measurement technique. However, PPG waveform is easy to be distorted by ambient light or vascular variation from temperature changes. Especially, irregular variation of PPG waveform caused by ambient temperature not only severely distorts the PPG, but also leads miss interpretation in clinical applications. Therefore, the investigation of between temperature and PPG waveform is quite important in using PPG. The purpose of this research is to quantify the PPG waveform characteristic and to investigate the waveform variation following the temperature change on measuring site. To quantify the fluctuation of PPG waveform, we use two techniques; detrended fluctuation analysis (DFA) and AC/DC analysis of PPG. We record PPG under temperature stress, which applied by medical use heat pack ($40^{\circ}C$) and ice pack ($0^{\circ}C$). Ten participants were applied to the experiment, and the result was evaluated to approve the temperature effect with statistical method, Wilcoxon signed rank test. The result shows that the AC component (p<0.05) and perfusion index DFS scale exponent (p<0.01) of PPG have the significance to temperature stress except for a DC component of PPG.

Design of Tissue-Transfer Container Using Thermoelectric Element Module

  • Park, Yong Pil;Cheon, Min-Woo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제18권2호
    • /
    • pp.66-69
    • /
    • 2017
  • The internal temperature of human-tissue transfers must be steadily maintained regardless of the external environmental changes. An ice pack and dry ice are the coolants for the transfer containers for which heat-insulating materials such as EPP (expended polypeopylene and EPS (expended polystrene) are used; however, changes of the external temperature/pressure and the melting of the coolants that is due to a long carriage result in changes of the internal temperature, and this makes it difficult to maintain the temperature. Accordingly, the thermoelectric element was used to design/manufacture a transfer container to maintain the internal temperature regardless of the external environmental changes. As a result of the measurement of the changes of the internal temperatures of the manufactured thermoelectric-element container and the EPS container over time, the internal temperature of the EPS container was increased, whereas the internal temperature of the thermoelectric-element container was maintained. The temperature of the distilled water that was poured into the containers indicated a pattern identical to that of the internal temperature.

매스콘크리트의 계절에 따른 온도이력과 압축강도에 관한 실험 (Study on Temperature History and Compressive Strength of Mock-up Concrete Considering Seasonal Change)

  • 김영주;공민호;김광기;양동일;박무영;정상진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 추계 학술논문 발표대회
    • /
    • pp.89-92
    • /
    • 2005
  • Our country has experienced variations in temperature as belong to the area of the continental climate that shows four significant seasons. These occur quality of construction. As the hydration of cement processes, the strength of concrete is developed. In order to improve the quality of concrete, various conditions including temperature and humidity should be maintained appropriately and concrete itself should be cured sufficiently This paper is basic experiment for estimating influence of strength by seasonal mock-up concrete's heat of hydration and estimate relationship of compressive strength development by curing temperature. And show basic document as quality control.

  • PDF

친수지역 강변여과수 열원을 활용한 냉난방시스템 개발 (Development of Water-Source Heat Pump System Using Riverbank Filtration Water on the Waterfront)

  • 조용;김대근;문종필
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.201.2-201.2
    • /
    • 2011
  • A water-source heat pump system has been developed for cooling and heating of a green house on the waterfront in Jinju. In order to supply a heat source/sink of water in alluvium aquifer to the heat pump system, the riverbank filtration facility (two pumping wells and one recharge well) for water intake and injection has been constructed. To pump and recharge water sufficiently, the geometric design such as depth and diameter for the wells have been completed, and details of the well such as slot size and length of the screen and filter pack size have been designed based on the practical and theoretical design method including D30 technique. For the investigation of the hydrogeological characteristics, step-drawdown test, long-term pumping test, and recovery test have been carried out for two developed pumping wells. Step-drawdown test has been performed on 4 step flowrates of 150, 300, 450, $600m^3$/day for 1 hour, and long-term pumping test on flowrate of $500m^3$/day for 24 hours, and recovery test for 6 hours. Since the underground water filtrated by riverbank is flowing smoothly into the well, the water level goes down slightly for the long-term test. Consequently, the stable pumping flowrate for two pumping well has been predicted at least over $1,647m^3$/day which is larger than the flowrate of $1,000m^3$/day for a 60 RT heat pump system.

  • PDF

단열용기의 잠열재 배치에 따른 내부 온도 균일성에 대한 영향 (Effect of Latent Heat Material Placement on Inside Temperature Uniformity of Insulated Transfer Boxes)

  • 지형용;정동열;최석천;김정열
    • 한국포장학회지
    • /
    • 제29권1호
    • /
    • pp.27-33
    • /
    • 2023
  • 본 연구에서는 저온물류 시스템의 단열용기의 온도유지 성능에 대하여 5℃급 저온 LHM을 배치하였을 때 배치구성 조건에 따른 온도특성을 확인하였다. LHM을 단열용기 내부에 배치하였을 때 6면과 5면에 상/하부 배치 비중에 차이를 두고 외기부하에 따른 내부 공기 온도균일도 및 목표 온도 유지시간을 분석하였다. 단열용기 내부 공기는 상부의 상승온도와 이때 발생하는 밀도차에 의한 공기 대류현상이 온도 성층화를 발생시키고, 균일도를 확보하기 위해 LHM의 상부 배치 비중이 하부보다 컸을 때 균일성이 높고 유지 시간이 오래 지속되는 것을 확인하였다. 다만, 상부 배치 비중을 높이기 위해 하부 배치를 제외한 조건에서 높은 균일성을 보이지만 짧은 유지 시간으로 보여 적정조건으로 알맞지 않다. 결과적으로 단열용기의 단열재 대칭구성과 LHM의 동일한 중량을 배치하여 보냉용기를 제작할 경우, LHM의 전면 배치를 바탕으로 하부에 비해 상부 배치 비중을 늘렸을 때 내부 공기 온도의 분포 균일도와 유지시간 성능을 높이는데 효율적인 방안이라고 판단된다. 저온물류 보냉용기 성능분석에 있어, 본 연구를 기반으로 다른 조건의 상변화 온도와 잠열량을 갖는 다양한 저온영역대의 LHM을 적용한 수치해석을 수행하여 성능 예측 결과를 확보할 수 있고 온도 균일도를 위한 단열 및 잠열 복합 구성 이송 용기의 최적 설계조건 수립에 기여할 것으로 기대된다.

2.3 kW급 전기자동차 배터리팩용 냉각 장치의 열전달 특성에 관한 해석적 연구 (Numerical Analysis of Heat Transfer Characteristics of Cooling System for 2.3 kW EV Battery Pack)

  • 성동민;박용석;성홍석;서정세
    • 한국기계가공학회지
    • /
    • 제21권6호
    • /
    • pp.44-49
    • /
    • 2022
  • The improvement in the battery performance and life using a battery thermal management system directly affects the improvement in the performance, life, and energy efficiency of electric vehicles. Therefore, this study numerically analyzed the heat exchange processes between the coolant inside the cooling plate channel and the heat generated by the battery. The cooling performance was analyzed based on the average temperature, temperature uniformity, and the maximum and minimum temperature differences of the battery. A performance difference existed depending on the coolant inlet temperature but showed the same tendency of cooling performance according to the shape of each plate's channel. Type 1 showed the best results in terms of battery temperature uniformity, which is the most important measure of battery performance; Type 2 showed the best results in terms of the average temperature of the battery; and Type 3 showed the best results in terms of the maximum and minimum temperature differences of the battery compared with that of the other cooling plates.

마찰교반용접한 A6061-T6의 기계적특성 평가 (Evaluation of Mechanical Properties of Friction Stir Welded A6061-T6)

  • 윤서현;박상현;남기우
    • 한국산업융합학회 논문집
    • /
    • 제27권1호
    • /
    • pp.9-15
    • /
    • 2024
  • In this study, the mechanical properties of friction stir welded A6061-T6 were evaluated. This material is used as a battery pack case material for electric vehicles. The Vickers hardness, tensile strength, and yield stress of the friction stir welding (FSW) specimen were all smaller than those of the base metal specimen. As the heat input increased, the nugget zone widened, and there were differences in hardness according to the base metal zone, heat affected zone, thermal-mechanical affected zone, and nugget zone. Mechanical properties were not proportional to heat input, and the thermal-mechanical affected zone on the advancing side was the smallest in all conditions. This is because the material flow speed increased on the advancing side, where the welding direction and the tool rotation direction were the same, forming a distinct boundary with mechanical deformation.

Effects of High-Frequency Treatment using Radiofrequency on Autonomic Nervous System and Pain in Women with Dysmenorrhea

  • Sungeon Park;Seungwon Lee;Inok Kim
    • Physical Therapy Rehabilitation Science
    • /
    • 제11권4호
    • /
    • pp.493-501
    • /
    • 2022
  • Objective: The purpose of this study is to present basic data for appropriate therapeutic intervention by confirming changes in the autonomic nervous system and pain by applying high-frequency deep diathermy to the lower abdomen in patients with primary dysmenorrhea. Design: A randomized controlled clinical trial. Methods: Thirty-eight women aged 18-50 years who complained of regular menstrual cycles (24-32 days) and primary dysmenorrhea symptoms were randomly assigned to a high-frequency therapy group (5, 7, or 9 mins) and a superficial heat therapy group (20 min). High frequency treatment group: The subject was in a supine position, and radio frequency was applied to the lower abdomen below the umbilicus. The radio frequency therapy device used in this study uses a 300 kHz capacitive electrode and a 500 kHz resistive electric transfer to deliver deep heat. Superficial heat treatment Group: Subjects applied a hot pack to the lower abdomen for 20 minutes while lying on their back. Evaluations were made of Heart rate variability and Visual Analogue Scale. Results: In subjects with menstrual pain, there was a significant difference in pain between the high-frequency therapy group and the superficial heat therapy group (p=0.026). However, there was no significant difference between the autonomic nervous system and the stress resistance (p>0.05). Conclusions: As a result of this study, high-frequencytreatment using radiofrequency was effective in relieving pain because it can penetrate deeper tissues than conventional hot packs using superficial heat. In particular, it was found that the optimum effect was obtained when high frequency was applied forfive-seven minutes.