• 제목/요약/키워드: Heat isolation structure

검색결과 19건 처리시간 0.023초

초저온 피스톤 펌프의 성능 향상에 관한 연구 (The Study on Development of Performance in Cryogenic Piston Pump)

  • 이종민;이종구;이광주;이종태
    • 한국수소및신에너지학회논문집
    • /
    • 제25권3호
    • /
    • pp.240-246
    • /
    • 2014
  • In order to develop a universal cryogenic piston pump of small size for increasing utilization of liquid hydrogen, dynamic compression performance of piston pump were evaluated and improvements were also discussed for piston rod and piston tip. The cryogenic piston pump has crosshead structure and inclined cup shape piston tip. As the results, it was found that i) insulation of heat flow from piston-rod part is required for stable operation ii) improving the self-clearance adjustment effect of piston tip and reducing piston eccentricity were desirable to promote pumping pressure and operating range.

A Novel Unequal Broadband Out-of-Phase Power Divider Using DSPSLs

  • Lu, Yun Long;Dai, Gao-Le;Li, Kai
    • ETRI Journal
    • /
    • 제36권1호
    • /
    • pp.116-123
    • /
    • 2014
  • In this paper, a novel unequal broadband out-of-phase power divider (PD) is presented. Double-sided parallel-strip lines (DSPSLs) are employed to achieve an out-of-phase response. Also, an asymmetric dual-band matching structure with two external isolation resistors is utilized to obtain arbitrary unequal power division, in which the resistors are directly grounded for heat sinking. A through ground via (TGV), connecting the top and bottom sides of the DSPSLs, is used to short the isolation components. Additionally, this property can efficiently improve the broadband matching and isolation bandwidths. To investigate the proposed divider in detail, a set of design equations are derived based on the circuit theory and transmission line theory. The theoretical analysis shows that broadband responses can be obtained as proper frequency ratios are adopted. To verify the proposed concept, a sample divider with a power division of 2:1 is demonstrated. The measured results exhibit a broad bandwidth from 1.19 GHz to 2.19 GHz (59.2%) with a return loss better than 10 dB and port isolation of 18 dB.

고무 면진 베어링 몰딩과정의 열전달 해석 및 실험 (An Experimental Study of Heat Transfer Analysis in Molding the Rubber Bearing for Seismic Isolator)

  • 강경주;문병영;강범수;김계수;정경수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집C
    • /
    • pp.275-280
    • /
    • 2001
  • Seismic isolator system is one of the most widely used base isolation system in order to control the vibration of structure against earthquake excitation. The evaluation of vulcanization time in molding the rubber bearing is very important for both proper ability of isolator and efficiency of manufacture. This paper deals with experimental measurement of temperature of isolator with senor inside in it, and compared with the result of FEA in order to evaluate the vulcanization time. Properties of rubber bearing which is used in the FEA are obtained by controlling the specific heat of rubber. With the obtained properties of rubber, the isolator is analysed by FEA. As a result, an appropriate analytical vulcanization time is obtained. This time is regarded as an appropriate temperature, which is used to effective manufacture.

  • PDF

가스 엔진 구동 열펌프 실외기 엔진/압축기 진동 절연 설계 (Designing isolation system for Engine/Compressor Assembly of GAS Driven Heat Pump)

  • Lenchine Valeri V.;Ko, Hong-Seok;Joo, Jae-Man;Oh, Sang-Kyoung
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.1128-1133
    • /
    • 2003
  • A gas driven heat pump (GHP) core design comprises internal combustion engine, compressors incorporated to a cooling/heating system, rubber mountings and belt transmissions. Main excitation farces are generated by an engine, compressors themselves and belt fluctuation. It leads to high vibration level of the mount that can cause damage of GHP elements. Therefore an appropriate design of the mounting system is crucial in terms of reliability and vibration reduction. In this paper oscillation of the engine mount is explored both experimentally and analytically. Experimental analysis of natural frequencies and operational frequency response of the GHP engine mounting system enables to create simplified model for numerical and analytical investigations. It is worked out criteria f3r vibration abatement of the isolated structure. Influence of bracket stiffness between engine and compressors, suspension locations and damper performance is investigated. Ways to reduce excitation forces and improve dynamic performance of the engine-compressor mounting system are considered from these analyses. Implementation of the proposed approach permits to choose appropriate rubber mountings and their location as well as joining elements design A phase matching technique can be employed to control forces from main exciters. It enables to changing vibration response of the structure by control of natural modes contribution. Proposed changes lead to significant vibration reduction and can be easily utilized in engineering practice.

  • PDF

Seismic modeling and analysis for sodium-cooled fast reactor

  • Koo, Gyeong-Hoi;Kim, Suk-Hoon;Kim, Jong-Bum
    • Structural Engineering and Mechanics
    • /
    • 제43권4호
    • /
    • pp.475-502
    • /
    • 2012
  • In this paper, the seismic analysis modeling technologies for sodium-cooled fast reactor (SFR) are presented with detailed descriptions for each structure, system and component (SSC) model. The complicated reactor system of pool type SFR, which is composed of the reactor vessel, internal structures, intermediate heat exchangers, primary pumps, core assemblies, and core support structures, is mathematically described with simple stick models which can represent fundamental frequencies of SSC. To do this, detailed finite element analyses were carried out to identify fundamental beam frequencies with consideration of fluid added mass effects caused by primary sodium coolant contained in the reactor vessel. The calculation of fluid added masses is performed by detailed finite element analyses using FAMD computer program and the results are discussed in terms of the ways to be considered in a seismic modeling. Based on the results of seismic time history analyses for both seismic isolation and non-isolation design, the functional requirements for relative deflections are discussed, and the design floor response spectra are proposed that can be used for subsystem seismic design.

Carbon Dioxide Sensor Substrate for Surface-mounted Packaging

  • Han, Hyeuk-Jin;Kim, Tae Wan;Park, Kwang-Min;Park, Chong-Ook
    • 센서학회지
    • /
    • 제24권3호
    • /
    • pp.159-164
    • /
    • 2015
  • Solid state electrochemical and chemo-resistive gas sensors have been used widely but can operate only under high temperature. For reducing the power consumption and optimizing the structure of the substrate of these sensors, we conducted device and circuit simulations using the COMSOL Multiphysics simulator. For assessing the effective types of substrate and heat isolation, we conducted three-dimensional thermal simulations in two separate parts; (a) by changing the shape of the contacting holes and (b) punching additional holes on the substrate. Thus, it was possible to achieve high temperature in the sensor end of the substrate while maintaining low power consumption, and temperature in the circuit.

SOI 및 TRENCH 구조를 이용한 저소비 전력형 미세발열체의 설계 (Design of Low Consume Power Ty7e Micro-heaters Using SOl and Trench Structures)

  • 장수;홍석우;이종춘;정귀상
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 추계학술대회 논문집
    • /
    • pp.350-353
    • /
    • 1999
  • This Paper Presents the optimized design of micro-heaters using 501(Si-on-insulator) substrate and oxide-filled trench structure In order to justify a lumped model approximation and thermal boundary assumptions, two-dimensional FDM(finite difference among which conduction is the dominant heat dissipation path. Compared with no-trenchs on the SOI structure, the micro-heaters with trench structures has properties of low heater loss and good thermal isolation. The simulation results show that the heater loss decreases as the number. width and distance of trenchs increases.

  • PDF

목조문화재 개판 상부에 설치하는 방염천의 화재전파 차단기능에 대한 실험연구 (An Experimental Study on the Capability of Arresting the Spread of a Fire of Fireproof Fabric Equipped over Ceiling Board of Wooden Cultural Properties)

  • 김현주;노삼규;김동철;함은구
    • 한국재난정보학회 논문집
    • /
    • 제8권3호
    • /
    • pp.297-303
    • /
    • 2012
  • 본 연구는 목조문화재 지붕 적심부의 화재전파 차단기능을 확보하기 위해 개판 상부에 설치하는 방염천의 차열성능을 알아보기 위한 실물모형 실험을 실시하여 방염천의 차열성능을 검증하고, 그 밖에 방염천의 설치방식에 따른(평형식과 접이식) 방화성능을 비교 분석하였다. 실험 결과, 방염천을 개판 상부에 평형식으로 설치한 경우 개판 하부온도가 $750^{\circ}C$일때 개판 상부온도가 $50^{\circ}C$$700^{\circ}C$ 정도의 온도차를 나타냈고 이는 방염천 미설치 시와 비교했을 때 개판 상부온도가 $580^{\circ}C{\sim}600^{\circ}C$ 정도 낮은 것으로, 방염천 설치로 인한 차열성능이 우수한 것으로 평가되었다. 방염천을 개판 상부에 접이식으로 설치한 경우 개판 하부온도가 $600^{\circ}C$일 때 개판 상부온도는 $65^{\circ}C$로 약 $530^{\circ}C$ 정도의 온도차를 보여 평형식으로 설치한 경우보다는 차열성능이 약간 떨어지는 것으로 나타났다.

355 nm UV 레이저 어블레이션을 이용한 마이크로-나노 구조의 액적 분리용 박막 필터 쾌속 제작 (Rapid Fabrication of Micro-nano Structured Thin Film for Water Droplet Separation using 355nm UV Laser Ablation)

  • 신보성
    • 한국정밀공학회지
    • /
    • 제29권7호
    • /
    • pp.799-804
    • /
    • 2012
  • Recently micro-nano structures has widely been reported to improve the performance of waterproof, heat isolation, sound and light absorption in various fields of electric devices such as mobiles, battery, display and solar panels. A lot of micro-sized holes on the surface of thin film provide excellent sound, or heat, or light transmission efficiency more than solid film and simultaneously nano-sized protrusions around micro hole increase the hydrophobicity of the surface of thin film because of lotus leaf effects as generally known previously. In this paper new rapid fabrication process with 355 nm UV laser ablation was proposed to get micro-nano structures on the surface of thin film, which have only been observed at higher laser fluence. Developed thin micro-nano structured film was also investigated the hydrophobic property by measuring the contact angle and demonstrated the possibility to apply to water droplet separation.

Through-Silicon Via를 활용한 3D NAND Flash Memory의 전열 어닐링 발열 균일성 개선 (Electro-Thermal Annealing of 3D NAND Flash Memory Using Through-Silicon Via for Improved Heat Distribution)

  • 손영서;이광선;김유진;박준영
    • 한국전기전자재료학회논문지
    • /
    • 제36권1호
    • /
    • pp.23-28
    • /
    • 2023
  • This paper demonstrates a novel NAND flash memory structure and annealing configuration including through-silicon via (TSV) inside the silicon substrate to improve annealing efficiency using an electro-thermal annealing (ETA) technique. Compared with the conventional ETA which utilizes WL-to-WL current flow, the proposed annealing method has a higher annealing temperature as well as more uniform heat distribution, because of thermal isolation on the silicon substrate. In addition, it was found that the annealing temperature is related to the electrical and thermal conductivity of the TSV materials. As a result, it is possible to improve the reliability of NAND flash memory. All the results are discussed based on 3-dimensional (3-D) simulations with the aid of the COMSOL simulator.