• Title/Summary/Keyword: Heat island intensity

Search Result 49, Processing Time 0.028 seconds

Heat Island Intensity in Seongseo, Daegu, South Korea - a Rural Suburb Containing Large Areas of Water

  • Kim, Ki-Young;Byon, Jae-Young;Kim, Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.22 no.10
    • /
    • pp.1337-1344
    • /
    • 2013
  • We examined urban heat island intensity in Seongseo, Dae gu, South Korea, where a large area of water is located within the suburb. We found a maximum urban heat island intensity of $4.2^{\circ}C$, which occurred around 7 PM in the summer season. Throughout the remainder of the year, we observed the largest heat island intensity levels during late night hours. In contrast, the winter season displayed the smallest values for heat island intensity. Our results conflicted with heat island intensity values for cities where suburbs did not contain water areas. Generally, cities with suburbs lacking water displayed the largest heat island intensity levels before sunrise in the winter season. We also observed negative urban heat island intensity levels at midday in all seasons except for the summer, which is also in contrast with studies examining suburbs lacking water areas. The heat island intensity value observed in this study ($4.2^{\circ}C$) was relatively large and fell between the averages for, Asia and Europe according to the relationship between urban population and heat island intensity.

On the Seasonal Variation of Urban Heat Island Intensity According to Meteorological Condition in Daegu (대구지역의 기상조건에 따른 도시열섬강도의 계절별 변화특성)

  • Ahn Ji-Suk;Kim Hae-Dong
    • Journal of Environmental Science International
    • /
    • v.15 no.6
    • /
    • pp.527-532
    • /
    • 2006
  • The purpose of this study is to clarify the characteristic of urban heat island intensity in urban area formed at a basin. Thermal environments for basin-type cities are influenced by significant topographic relief winds. In this study, we analyzed the diurnal variations of the heat island intensity according to meteorological condition and season using AWS(Automatic Weather observation System) data in Daegu Metropolitan area for 1 year(3/April, 2003 $\sim$ 2/April, 2004). In this study, we defined the urban heat island intensity as the air temperature difference between two points, the downtown and the suburban area. The suburban area is located at valley mouth around the western tip of Daegu. The results are summarized as follows; 1. The maximum heat island intensity was recorded at early morning under the meteorological conditions, calm and clear 2. The heat island intensity was strong in the order of winter, fall, spring and summer. 3. The heat island intensity came out minus values in the afternoon. This phenomenon is known as a com mon for basin-type cities. 4. The heat island intensity was twice or more in clear and calm than not so.

Analysis of the Effects of Advection and Urban Fraction on Urban Heat Island Intensity using Unified Model for Seoul Metropolitan Area, Korea (통합모델을 활용한 이류와 도시비율이 서울 수도권 지역의 도시열섬강도에 미치는 영향 분석)

  • Hong, Seon-Ok;Kim, Do-Hyoung;Byon, Jae-Young;Park, HyangSuk;Ha, Jong-Chul
    • Atmosphere
    • /
    • v.29 no.4
    • /
    • pp.381-390
    • /
    • 2019
  • This study investigates the impacts of urban land-use fraction and temperature advection on the urban heat island intensity over the Seoul metropolitan area using the UM (Unified Model) with the MORUSES (Met Office Reading Urban Surface Exchange Scheme) during the heat wave over the region from 2 to 8, August 2016. Two simulations are performed with two different land-use type, the urban (urban simulation) and the urban surfaces replaced with grass (rural simulation), in order to calculate the urban heat island intensity defined as the 1.5-m temperature difference between the urban and the rural simulations. The land-use type for the urban simulation is obtained from Korea Ministry of Environment (2007) land-use data after it is converted into the types used in the UM. It is found that the urban heat island intensity over high urban-fraction regions in the metropolitan area is as large as 1℃ in daytime and 3.2℃ in nighttime, i.e., the effects of urban heat island is much larger for night than day. It is also found that the magnitude of urban heat island intensity increases linearly with urban land-use fraction. Spatially, the estimated the urban heat island intensities are systematically larger in the downwind regions of the metropolitan area than in the upwind area due to the effects of temperature advection. Results of this study indicate that urban surface fraction in the city area and temperature advection play a key role in determining the spatial distribution and magnitude of urban heat island intensity.

A Study on the Mitigation Policies for Urban Heat Island (도시열섬 완화를 위한 제도개선)

  • Suh, Eung Chul
    • KIEAE Journal
    • /
    • v.7 no.2
    • /
    • pp.17-23
    • /
    • 2007
  • While heat island has been recognized as an unique environmental nuisance in cities, the phenomenon tends to be regarded as an inevitable side effect on urbanization. Recently the nature of the heat island has been disclosed and efforts for the remedy have been discussed in many ways. Some pioneering actions have been taken to mitigate the strength of the heat island's intensity in several countries. After studies for the heat island and speculations on current pilot policies of 3 different countries has been done, mitigation policies for heat island has been suggested as followings. 1. Preservation of natural topography is essential because latent energy consumption(evapotranspiration) from the site is the single most important factor to mitigate the energy surplus caused by urban heat island. 2. Because current national zoning ordinance or building law can not effectively control the site specific local environment, heat island policy should be established or employed at local level. 3. Incentives for the mitigation should be adopted on the process of implementation because environment is public concern. 4. Wind can easily dissipate energy surplus which is the major driving force for heat island. Therefore local wind, the direction and intensity should be sustained and sometimes facilitated fully through policies.

An Analysis on the Variation Trend of Urban Heat Island in Busan Area (2006-2010) (부산지역 도시 열섬의 변화경향 분석 (2006-2010))

  • Do, Woo-Gon;Jung, Woo-Sik
    • Journal of Environmental Science International
    • /
    • v.21 no.8
    • /
    • pp.953-963
    • /
    • 2012
  • The annual variations of the urban heat island in Busan is investigated using surface temperature data measured at 3 automatic weather stations(AWSs) for the 5 years period, 2006 to 2010. Similar to previous studies, the intensity of the urban heat island is calculated using the temperature difference between downtown(Busanjin, Dongnae) and suburb(Gijang). The maximum hourly mean urban heat island are $1.4^{\circ}C$ at Busanjin site, 2300LST and $1.6^{\circ}C$ at Dongnae site, 2100LST. It occurs more often at Dongnae than Busanjin. Also the maximum hourly mean urban heat island appears in November at both sites. The urban heat island in Busan is stronger in the nighttime than in the daytime and decreases with increasing wind speed, but it is least developed in summer. Also it partly causes the increasement of nighttime PM10 concentration.

Analysis of the Effect of Heat Island on the Administrative District Unit in Seoul Using LANDSAT Image (LANDSAT영상을 이용한 서울시 행정구역 단위의 열섬효과 분석)

  • Lee, Kyung Il;Ryu, Jieun;Jeon, Seong Woo;Jung, Hui Cheul;Kang, Jin Young
    • Korean Journal of Remote Sensing
    • /
    • v.33 no.5_3
    • /
    • pp.821-834
    • /
    • 2017
  • The increase in the rate of industrialization due to urbanization has caused the Urban Heat Island phenomenon where the temperature of the city is higher than the surrounding area, and its intensity is increasing with climate change. Among the cities where heat island phenomenon occurs, Seoul city has different degree of urbanization, green area ratio, energy consumption, and population density in each administrative district, and as a result, the strength of heat island is also different. So It is necessary to analyze the difference of Urban Heat Island Intensity by administrative district and the cause. In this study, the UHI intensity of the administrative gu and the administrative dong were extracted from the Seoul metropolitan area and the differences among the administrative districts were examined. and linear regression analysis were conducted with The variables included in the three categories(weather condition, anthropogenic heat generation, and land use characteristics) to investigate the cause of the difference in heat UHI intensity in each administrative district. As a result of analysis, UHI Intensity was found to be different according to the characteristics of administrative gu, administrative dong, and surrounding environment. The difference in administrative dong was larger than gu unit, and the UHI Intensity of gu and the UHI Intensity distribution of dongs belonging to the gu were also different. Linear regression analysis showed that there was a difference in heat island development intensity according to the average wind speed, development degree, Soil Adjusted Vegetation Index (SAVI), Normalized Difference Built-up Index (NDBI) value. Among them, the SAVI and NDBI showed a difference in value up to the dong unit and The creation of a wind route environment for the mitigation of the heat island phenomenon is necessary for the administrative dong unit level. Therefore, it is considered that projects for mitigating heat island phenomenon such as land cover improvement plan, wind route improvement plan, and green wall surface plan for development area need to consider administrative dongs belonging to the gu rather than just considering the difference of administrative gu units. The results of this study are expected to provide the directions for urban thermal environment design and policy development in the future by deriving the necessity of analysis unit and the factors to be considered for the administrative city unit to mitigate the urban heat island phenomenon.

A Study on the Change of the Urban Heat Island Structure in Busan Metropolitan Area, Korea (부산지역의 도시열섬 구조 변화에 관한 연구)

  • Kim, Hyunsu;Seok, Hyun-Bae;Kim, Yoo-Keun
    • Journal of Environmental Science International
    • /
    • v.23 no.11
    • /
    • pp.1807-1820
    • /
    • 2014
  • The spatial and temporal changes of the annual mean urban heat island(UHI) intensity were investigated using near surface temperature data measured at 16 automatic weather systems(AWS) in Busan metropolitan area(BMA) during the 11-yr period, from 2000 to 2010. For nighttime, the annual mean UHI intensity at Dongnae(U1) in 2000 was weaker than it in 2010. However the change of the annual mean UHI intensity at Daeyeon(U2) during 11 years was different from it at U1. The annual frequency of the UHI intensity over $5^{\circ}C$ considerably increased at U2 and decreased at U1 during 11 years. The center of the UHI also spatially shifted southward with Daeyeon and Haeundae in BMA. It would be caused by the increase of urban area, population-density and transportation near U2 and by the decrease of them near U1. We found that the spatial and temporal differences of the UHI intensity have coincided with changes of land-use, population density and transportation in BMA.

A Satellite View of Urban Heat Island: Causative Factors and Scenario Analysis

  • Wong, Man Sing;Nichol, Janet;Lee, Kwon-Ho
    • Korean Journal of Remote Sensing
    • /
    • v.26 no.6
    • /
    • pp.617-627
    • /
    • 2010
  • Although many researches for heat island study have been developed, there is little attempt to link the findings to actual and hypothetical scenarios of urban developments which would help to mitigate the Urban Heat Island (UHI) in cities. The aim of this paper is to analyze the UHI at urban area with different geometries, land use, and environmental factors, and emphasis on the influence of different geometric and environmental parameters on ambient air temperature. In order to evaluate these effects, the parameters of (i) Air pollution (i.e. Aerosol Optical Thickness (AOT)), (ii) Green space Normalized Difference Vegetation Index (NDVI), (iii) Anthropogenic heat (AH) (iv) Building density (BD), (v) Building height (BH), and (vi) Air temperature (Ta) were mapped. The optimum operational scales between Heat Island Intensity (HII) and above parameters were evaluated by testing the strength of the correlations for every resolution. The best compromised scale for all parameters is 275m resolution. Thus, the measurements of these parameters contributing to heat island formation over the study areas of Hong Kong were established from mathematical relationships between them and in combination at 275m resolution. The mathematical models were then tabulated to show the impact of different percentages of parameters on HII. These tables are useful to predict the probable climatic implications of future planning decisions.

A Study on the Relation of Urban Heat Island and Air Pollution in Seoul Area (서울지역의 도시열섬현상과 대기오염도의 관계에 관한 연구)

  • 장영기;김정욱
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.7 no.1
    • /
    • pp.49-53
    • /
    • 1991
  • Relations of urban heat island and air pollution are analyzed by using $SO_2$ concentration data (winter season in 1985) from 10 sites of Seoul area and differences of wind speed and air temperature in urban and rural area. Urban heat island is developed when daily mean wind speed at urban site is lower than 1.5m/sec or in the interval of 3.0 $\sim$ 3.5m/sec. When differences between urban and rural air temperature is greater than the overall average of those differences, $SO_2$ concentrations of those above-average differences are 1.3 $\sim$ 1.8 times higher than those of below-average differences. The trends are shown obviously at north-eastern area of Seoul (Gilum Dong, Ssangmun Dong, Myeonmog Dong). When intensity of Urban Heat Island is weak, $SO_2$ concentration was reduced in propotion to a rise of wind speed. But $SO_2$ concentration is on the partial increase in spite of a rise of wind speed when intensity of urban heat island is strong.

  • PDF

Mapping and Analyzing the Park Cooling Intensity in Mitigation of Urban Heat Island Effect in Lahore, Pakistan

  • Hanif, Aysha;Nasar-u-Minallah, Muhammad;Zia, Sahar;Ashraf, Iqra
    • Korean Journal of Remote Sensing
    • /
    • v.38 no.1
    • /
    • pp.127-137
    • /
    • 2022
  • Urban Heat Island (UHI) effect has been widely studied as a global concern of the 21st century. Heat generation from urban built-up structures and anthropogenic heat sources are the main factors to create UHIs. Unfortunately, both factors are expanding rapidly in Lahore and accelerating UHI effects. The effects of UHI are expanding with the expansion of impermeable surfaces towards urban green areas. Therefore, this study was arranged to analyze the role of urban cooling intensity in reducing urban heat island effects. For this purpose, 15 parks were selected to analyze their effects on the land surface temperature (LST) of Lahore. The study obtained two images of Landsat-8 based on seasons: the first of June-2018 for summer and the second of November-2018 for winter. The LST of the study area was calculated using the radiative transfer equation (RTE) method. The results show that the theme parks have the largest cooling effect while the linear parks have the lowest. The mean park LST and PCI of the samples are also positively correlated with the fractional vegetation cover (FVC) and normalized difference water index (NDWI). So, it is concluded that urban parks play a positive role in reducing and mitigating LST and UHI effects. Therefore, it is suggested that the increase of vegetation cover should be used to develop impervious surfaces and sustainable landscape planning.