• Title/Summary/Keyword: Heat intensity

Search Result 775, Processing Time 0.029 seconds

Flash Drought Onset and Development Mechanisms Using Flash Drought Intensity Index (FDII) Based on Satellite-Based Soil Moisture (위성영상 토양수분 기반 FDII를 활용한 돌발가뭄의 메커니즘 분석)

  • Lee, Hee-Jin;Nam, Won-Ho;Sur, Chanyang;Jason A. Otkin;Yafang Zhong;Mark D. Svoboda
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.3
    • /
    • pp.57-67
    • /
    • 2023
  • A flash drought is a rapid-onset drought that develops over a short period of time as weather and environmental factors change rapidly, unlike general droughts, due to meteorological abnormalities. Abnormally high evapotranspiration rates and rapid declines in soil moisture increase vegetation stress. In addition, crop yields may decrease due to flash droughts during crop growth and may damage agricultural and economic ecosystems. In this study, Flash Drought Intensity Index (FDII) based on soil moisture data from Gravity Recovery Climate Experiment (GRACE) was used to analyze flash drought. FDII, which is calculated using soil moisture percentile, is expressed by multiplying two factors: the rate of intensification and the drought severity. FDII was developed for domestic flash drought events from 2014 to 2018. The flash drought that occurred in 2018, Chungcheongbuk-do showed the highest FDII. FDII was higher in heat wave flash drought than in precipitation deficit flash drought. The results of this study show that FDII is reliable flash drought analysis tool and can be applied to quantitatively analyze the characteristics of flash drought in South Korea.

Evaluation on Probability and Intensity of Hazards Exposure by Construction Occupations (건설업 직종별 노출 가능 유해인자 및 노출강도에 관한 평가)

  • Hyunhee Park;Sedong Kim
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.33 no.3
    • /
    • pp.317-331
    • /
    • 2023
  • Objectives: Construction workers are exposed to various hazardous substances simultaneously. However, little is known about the exposure hazards in construction industry. This study was aimed at identifying the risk of exposure hazards among construction workers. Methods: The expert survey (n=29) was conducted, including construction industry health managers (n=11) and work environment monitoring experts (n=18), on exposure probability, intensity and risk of hazardous substances by construction occupations Results: The exposure hazards of 30 construction occupations were identified and summarized through a literature review and expert survey. The most prevalent hazards were in order of noise, awkward posture, heat/cold, crystalline silica, cement/concrete dust, metal fumes, and volatile organic compounds. The hazards with highest risk score(over seven points) at construction occupations were noise(formwork carpenter, concrete finisher, rebar worker, demolition worker, driller/rock blaster), hazardous rays(welder), heat/cold (earthworks, formwork carpenter, rebar worker, concrete placer, scaffolder), awkward posture(bricklayer, caulker/tile setter, rebar worker) and heavy lifting(bricklayer, rebar worker). Among construction workers, the job types with the highest risk of exposure to carcinogens, and in which occupational cancer has been reported, were in order of stonemason, concrete finisher, rock blaster, welder, insulation installer, painter, scaffolder, plant worker and earthworks in order Conclusions: Systematic research and discussion on occupational disease among construction workers and its various hazardous factors are needed to establish job exposure matrix for facilitating standard for promptly processing the workers' compensation.

A Study on the Combined Heat Transfer and Analysis Fire Induced Combustion Gas in a partially Open Enclosure (개구부가 있는 밀폐공간내 화재의 복합열전달 및 연소가스 분석에 관한 연구)

  • Park, Chan-Kuk;Chu, Byeong-Gil;Kim, Cheol
    • Fire Science and Engineering
    • /
    • v.11 no.1
    • /
    • pp.21-35
    • /
    • 1997
  • The natural convection and combined heat transfer induced by fire in a rectangular enclosure is numerically studied. The model for this numerical analysis is partially opened right wall. The solution procedure includes the standard k-$\varepsilon$ model for turbulent flow and the discrete ordinates method (DOM) is used for the calculation of radiative heat transfer equation. In numerical study, SIMPLE algorithm is applied for fluid flow analysis, and the investigations of combustion gas induced by fire is performed by FAST model of HAZARD I program. In this study, numerical simulation on the combined naturnal convection and radiation is carried out in a partial enclosure filled with absorbed-emitted gray media, but is not considered scattering problem. The streamlines, isothermal lines, average radiation intensity and kinetic energy are compared the results of pure convection with those of the combined convection-radiation, the combined heat transfer. Comparing the results of pure convection with those of the combined convection-radiation, the combined heat transfer analysis shows the stronger circulation than those of the pure convection. Three different locations of heat source are considered to observe the effect of heat source location on the heat transfer phenomena. As the results, the circulation and the heat transfer in the left region from heating block are much more influenced than those in the right region. It is also founded that the radiation effect cannot be neglected in analyzing the building in fire. And as the results of combustion gas analysis from FAST model, it is found that O2 concentration is decreased according to time. While CO and CO2 concentration are rapidly increased in the beginning(about 100sec), but slowly decreased from that time on.

  • PDF

Recent Research Works on Chemiluminescence as Measures of Combustion Characteristics (화학발광을 활용한 연소계측 연구동향)

  • Seo, Seonghyeon;Moon, Insang
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.18 no.1
    • /
    • pp.73-84
    • /
    • 2014
  • The present paper includes recent research works on the estimation of physical properties like equivalence ratio and heat release rate of flame through chemiluminescence measurement. Modern combustion devices require a precise control to increase combustion stability as well as to suppress pollutant emissions. The determination of combustion characteristics from chemiluminescence provides practical advantages over other techniques. However, the technique is dependent on equivalence ratio, combustion pressure, inlet temperature, turbulent intensity and fuel type. The intensity ratio of $OH^*$ and $CH^*$ has a strong relation with an equivalence ratio for methane/air premixed flames. The global measurement of chemiluminescence is accepted as a good indicator for a global heat release rate.

Alternation of Topical Heat and Cold for Chronic Low Back Pain : A Randomized Controlled Pilot Trial

  • Choi, Young Doo;Jo, Su Jeong;Jung, Chan Yung;Kim, Kap Sung;Lee, Seung Deok
    • Journal of Acupuncture Research
    • /
    • v.33 no.2
    • /
    • pp.77-87
    • /
    • 2016
  • Objectives : This is a pilot study for a large randomized controlled trial to investigate the efficacy and safety of a newly developed contrast therapy device-- alternating topical heat and cold -- for patients with chronic low back pain. The main objective of this study is to confirm the feasibility of the study design. Methods : The design was a randomized, 2-arm, parallel-group, single-blind, placebo controlled trial. Patients in each group received real or sham contrast therapy in an acupuncture point 10 times over four weeks. The primary outcome measure was pain intensity on a 100-mm visual analogue scale (VAS). The secondary outcomes were back-related dysfunction based on the Oswestry Disability Index (ODI), the Roland-Morris disability questionnaire (RMDQ), and range of motion of lumbar spine based on the modified Schober test (mSchober test), Finger-to-Floor distance (FTF distance), and Finger-to-Thigh distraction (FTT distraction). Results : A total of 30 subjects with chronic low back pain were randomly assigned to a contrast therapy group (n=15) or a sham group (n=15). A repeated-measures analysis of variance showed statistically significant group time interaction for VAS, RMDQ, mSchober test and FTF distance (p<0.05). The treatment group showed significant improvement in pain intensity and functional disability as compared to the sham group. Conclusion : Contrast therapy may be an effective and safe treatment for chronic low back pain.

Effects of Land Use Pattern on Urban Heat Island in Chungju City (토지이용형태가 도시열섬현상에 미치는 영향 - 충주시를 사례로 -)

  • Yoon, Yong-Han;Bae, Byung-Ho;Kim, Won-Tae;Park, Bong-Ju;Cho, Sung-Moh;Cho, Hyun-Soo
    • Journal of Environmental Science International
    • /
    • v.16 no.9
    • /
    • pp.1063-1069
    • /
    • 2007
  • The present study investigated the causes and intensity of the urban heat island phenomenon by the seasons according to the pattern of land use in Chungju City. Highest temperature and lowest moisture areas of the urban were very similar to the distribution of commercial districts, on the other hand, lowest temperature and highest moisture areas were distributed in manufacturing districts, green zones and the Hoam Lake. If appear at intensity of the distance from the outer circumference of commercial districts, wind direction and the rise of temperature, we could observe the remarkable expansion of high temperature from commercial districts toward residential districts around of downwind in all seasons. In case the effect of the wind was not significant as well, high temperature in commercial districts appeared tendency that a little spread to 1, 2 residential districts around. But checked up the intimate relations between the amount of moving heat and wind, when out of consideration that size of area was not much compared than residential areas of downwind affected by the wind. These phenomenon was relatively obvious in summer, the other side, in spring and autumn appeared a similar tendency.

Effects of District Energy Supply by Combined Heat and Power Plant on Greenhouse Gas Emission Mitigation (열병합발전을 이용한 집단에너지사업의 온실가스 감축효과)

  • Shin, Kyoung-A;Dong, Jong-In;Kang, Jae-Sung;Im, Yong-Hoon;Kim, Da-Hye
    • Journal of Climate Change Research
    • /
    • v.8 no.3
    • /
    • pp.213-220
    • /
    • 2017
  • The purpose of this study is to analyze effects of Greenhouse Gas (GHG) emission reduction in district energy business mainly based on Combined Heat and Power (CHP) plants. Firstly this paper compares the actual carbon intensity of power production between conventional power plants and district energy plants. To allocate the GHG from CHP plants, two of different methods which were Alternative Generation Method and Power Bonus Method, have been investigated. The carbon intensity of power production in district energy plants ($0.43tonCO_2e/MWh$) was relatively lower than conventional gas-fired power plants ($0.52tonCO_2e/MWh$). Secondly we assessed the cost effectiveness of reduction by district energy sector compared to the other means using TIMES model method. We find that GHG marginal abatement cost of 'expand CHP' scenario (-$134/ton$CO_2$) is even below than renewable energy scenario such as photovoltaic power generation ($87/ton$CO_2$). Finally the GHG emission reduction potential was reviewed on the projected GHG emission emitted when the same amount of energy produced in combination of conventional power plants and individual boilers as substitution of district energy. It showed there were 10.1~41.8% of GHG emission reduction potential in district energy compared to the combination of conventional power plants and individual boilers.

A Case Report of Migraine with Typical Aura on Korean Medical Treatments

  • Cho, Myoung-Ui;Lim, Su-Yeon;Jeon, Hyun-A;Lee, Ji-Yeon;Moon, Young-Joo;Song, Kwang-Chan;Koh, Young-Tak
    • Journal of Oriental Neuropsychiatry
    • /
    • v.29 no.4
    • /
    • pp.315-324
    • /
    • 2018
  • Objectives: The objective of this case report was to investigate the effect of Korean medicine therapy on migraine patients with typical aura. Methods: Acupuncture and chuna manual therapy were applied to outpatients once in 1 to 2 weeks, a total of 9 times, for about 11 weeks. A patient was diagnosed with ganyang-toutong and taeeumin dry-heat symptomatic pattern. Herbal medicine (Chongsanggeontong-tang Gagambang (淸上?痛湯加減方)) was prescribed for 15 days up to the 3rd visit, then another herbal medicine (Yeoldahanso-tang (熱多寒少湯)) prescribed for 15 days up to the 6th visit. MSQol and MIDAS were used as a tool at the start and after 9th treatment. The intensity and frequency of headache, frequency of aura and neck pain were examined on every visit. Results: According to the results, Korean traditional medicine described above had effect on the intensity and frequency of headache, frequency of aura and neck pain as well as an increase in the figure of MSQoL from 62 to 81 and decrease of MIDAS Disability from 18 to 7, Duration from 60 to 30, Pain score from 8 to 2. Conclusions: Migraine with typical aura classified as ganyang-toutong and taeeumin dry-heat symptomatic pattern can be alleviated by Korean traditional medicine.

Fluid flow and heat transfer around tubes arranged in line (일행관군에서의 유동특성과 열전달현상에 관한 연구)

  • 부정숙;조석호;정규하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1603-1612
    • /
    • 1990
  • An experimental study is conducted to investigate the fluid flow and heat transfer around tubes arranged in line. All measurements are performed at Reynolds number 1.58*10$^{4}$ with varing tube spacings from the small pitch ratio(L/D=1.25) to the large pitch ratio(L/D=3.0). Mean static pressures and mean temperatures of the surface of tubes and mean velocities and turbulent intensities in tube banks are measured. The flow patterns and the characteristics of heat transfer are strongly influenced by the tube spacings. Especially, in the case of very small spacings(L/D=1.25), the flow between neighboring tubes becomes very stagnant and the heat transfer decreases. In the case of each tube spacing, the characteristics of heat transfer around the 3rd, the 4th and the 5th tubes are nearly similar to one another, because the flow around tubes becomes stable at the 3rd tubes. The local heat transfer has the peak value near the reattachment point which has the peak value of pressure, but the local heat transfer for the 2nd tube of L/D=1.25 without reattaching has the peak value at .theta.=75.deg.. For each pitch ratio, the mean heat transfer increases gradually toward the downstream tubes, because the oncoming flow through neighboring tubes comes closer to the forward and rear surfaces of the tube and the turbulent intensity becomes larger in the downstream direction.

A Study of the Urban Heat Island in Seoul using Local Analysis System (지역규모 분석 모델을 이용한 서울 도시열섬 특성 연구)

  • Chun, Ji Min;Lee, Seon-Yong;Kim, Kyu Rang;Choi, Young-Jean
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.30 no.2
    • /
    • pp.119-127
    • /
    • 2014
  • A very high resolution weather analysis system (VHRAS) of 50 m horizontal resolution is established based on LAPS. VHRAS utilizes the 3 hourly forecast data of the Unified Model (UM) of the Korea Meteorological Administration (KMA) with the horizontal resolution of 12 km as initial guess fields. The analysis system ingests the automatic weather station (AWS) data as input observations. The analysis system operates every hour for Seoul, Korea region in real time basis. It takes less than 10 minutes for one analysis cycle. The size of grid of the analysis domain is $800{\times}660$, respectively. The analysis results from December 2010 to February 2011 showed that the mean biases of temperature, maximum and minimum temperature were -0.07, 1.6, $0.2^{\circ}C$, respectively. The temperature in the central part of the city revealed relatively higher value than that of the surrounding mountainous areas, which showed a heat island feature. The heat island appears in zonal direction since the central city region is developed along a large river. Along the heat island, the eastern region was warmer than the western region. The warmer temperature in the western part of the heat island was caused by anthropogenic heat change in conjunction with the change of land use. This system will provide more reliable weather data and information in Seoul.