• Title/Summary/Keyword: Heat fluxes

Search Result 367, Processing Time 0.023 seconds

Comparative Analysis of Surface Heat Fluxes in the East Asian Marginal Seas and Its Acquired Combination Data

  • Sim, Jung-Eun;Shin, Hong-Ryeol;Hirose, Naoki
    • Journal of the Korean earth science society
    • /
    • v.39 no.1
    • /
    • pp.1-22
    • /
    • 2018
  • Eight different data sets are examined in order to gain insight into the surface heat flux traits of the East Asian marginal seas. In the case of solar radiation of the East Sea (Japan Sea), Coordinated Ocean-ice Reference Experiments ver. 2 (CORE2) and the Objectively Analyzed Air-Sea Fluxes (OAFlux) are similar to the observed data at meteorological stations. A combination is sought by averaging these as well as the Climate Forecast System Reanalysis (CFSR) and the National Centers for Environmental Prediction (NCEP)-1 data to acquire more accurate surface heat flux for the East Asian marginal seas. According to the Combination Data, the annual averages of net heat flux of the East Sea, Yellow Sea, and East China Sea are -61.84, -22.42, and $-97.54Wm^{-2}$, respectively. The Kuroshio area to the south of Japan and the southern East Sea were found to have the largest upward annual mean net heat flux during winter, at -460- -300 and at $-370--300Wm^{-2}$, respectively. The long-term fluctuation (1984-2004) of the net heat flux shows a trend of increasing transport of heat from the ocean into the atmosphere throughout the study area.

Experimental Study on Evaporation Heat Transfer and Oil Effect in Micro-fin Tube Using $CO_2$ (마이크로핀관 내 $CO_2$의 증발 열전달과 오일 영향에 관한 실험적 연구)

  • Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.106-112
    • /
    • 2008
  • In this paper, the experimental results on evaporation heat transfer characteristics were reported for a micro-fin tube using $CO_2$. An experimental refrigerant loop had been established to measure the evaporation heat transfer coefficient and pressure drop of $CO_2$. Experiments were conducted for mass fluxes, heat fluxes, saturation temperatures and PAG oil concentrations. With increasing the heat flux and the saturation temperature, the evaporation heat transfer coefficient increased. At the higher mass flux, however, the exit vapor quality of the micro-fin tube was to be lower. The peak of the heat transfer coefficient was shifted toward low quality region. The evaporation pressure drop increased as the mass flux increased and the saturation temperature decreased. As PAG oil concentration increased, the evaporation heat transfer coefficient decreased and the dryout was delayed by oil addition.

A study on the characteristics of heat transfer and pressure drop in plate type evaporator with U-turn for automotive air conditioner (유턴 흐름을 갖는 차량공조용 플레이트형 증발기의 전열특성에 관한 연구)

  • 강정길;김종수
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.11 no.4
    • /
    • pp.472-483
    • /
    • 1999
  • The evaporation heat transfer and pressure drop characteristics for HFC-l34a in flat plate type heat exchangers with enhanced beads were experimentally investigated. Three plate type evaporators with different geometric condition of U-turn area were tested. Mass fluxes were tested over the range of 83kg/$m^2$s to 166kg/$m^2$s, and heat fluxes were varied from 4㎾/$m^2$ to 12㎾/$m^2$. Evaporation temperature was 5$^{\circ}C$ with inlet qualities of 0.1 to 1.0. There was no notable difference in the heat transfer coefficient by geometric variation of U-turn area, but the third plate with cross-ribbed channel at U-turn area was better than others in the evaluation using volume goodness factor comparison. Also, the mixtures of HFC-l34a and PAG oil was tested to determine oil effects on heat transfer and pressure drop. As oil concentration was increased, heat transfer coefficient was increased by 22~48% up to the 3wt.%, but decreased by 14~22% at the 4wt.%. The pressure drop was increased by the maximum of 100% as oil concentration was increased.

  • PDF

Experimental Study on Effects of PAG Oil for $CO_2$ Evaporation Heat Transfer (PAG 오일이 $CO_2$ 증발열전달에 미치는 영향에 관한 실험적 연구)

  • Lee, Sang-Jae;Kim, Dae-Hoon;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.5
    • /
    • pp.357-363
    • /
    • 2008
  • In order to investigate $CO_2$ heat transfer coefficient and pressure drop by PAG oil concentration during $CO_2$ evaporation, the experiment on evaporation heat transfer characteristics in a horizontal micro-fin tube was performed. The experimental apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes($400{\sim}1200\;kg/m^2s$), heat fluxes($10{\sim}30\;kW/m^2$) and saturation temperatures ($-5{\sim}5^{\circ}C$), and PAG oil concentration($0{\sim}5\;wt%$). The variation of the heat transfer coefficient was different in accordance with the oil concentration. With the increase of the oil concentration, the evaporation heat transfer coefficient decreased and the delay of dryout by oil addition was found. Pressure drop increased with the increase of the oil concentration and heat flux, and the decrease of saturation temperature.

Long Term Flux Variation Analysis on the Boseong Paddy Field (보성 농업지역에서의 장기간 플럭스 특성 분석)

  • Young-Tae Lee;Sung-Eun Hwang;Byeong-Taek Kim;Ki-Hun Kim
    • Atmosphere
    • /
    • v.34 no.1
    • /
    • pp.69-81
    • /
    • 2024
  • In this paper, Annual flux variations in the Boseong Tall Tower (BTT) from 2016 to 2020 were analyzed using data from three levels (2.5 m, 60 m, and 300 m). BTT was installed in Boseong-gun, Jeollanam-do in February 2014 and continued to conduct energy exchange observations such as CO2, sensible heat, and latent heat using the eddy covariance method until March 2023. The BTT was located in a very flat and uniform paddy field, and flux observations were conducted at four levels: 2.5 m, 60 m, 140 m, and 300 m above ground. Surface energy balance was confirmed from observed data of net radiation flux, soil heat flux, sensible heat flux, and latent heat flux. Additionally, 2.5 m height surface fluxes, which are most influenced by agricultural land, were compared with data from Local Data Assimilation and Prediction System (LDAPS) of the Korea Meteorological Administration to evaluate the accuracy of LDAPS flux data. The correlation coefficient between LDAPS flux data and observed values was 0.95 or higher. Excluding summer latent heat flux data, there was a general tendency for LDAPS data to be higher than observed values. The footprint areas estimated below 60 m height mainly covered agricultural land, and flux observations at 2.5 m and 60 m heights showed typical agricultural characteristics. In contrast, the footprint estimated at 300 m height did not show agricultural characteristics, indicating that observations at this height encompassed a wide range, including mountains, sea, and roads. The analysis results of long-term flux observations can contribute to understanding the energy and carbon dioxide fluxes in agricultural fields. Furthermore, these results can be utilized as essential data for validating and improving numerical models related to such fluxes.

A Study on the Periodic Transient Response Characteristics in Annular Fin with Uniform Thickness (均一두께의 環狀흰에서 週期的 過渡應答 特性에 관한 硏究)

  • 김광수
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.2
    • /
    • pp.338-348
    • /
    • 1988
  • This study presents an analysis of periodic heat diffusion in an annular fin with uniform thickness. When the temperature of the fin base is changed in the form of a sinusoidal function, the exact temperature solution can be obtained by Laplace transformation in terms of the dimensionless parameters in the infinite series. Local heat flux and average heat flux, local fin efficiency and average fin efficiency were obtained. Particularly, the table of eigenvalues that are the indispensable condition in solving the heat transfer problem of annular fin in a transient state with convection phenomena at the fin edge is provided. The tables of heat fluxes and average heat fluxes, fin efficiencies and average fin efficiencies are also provided from the computed results. Also, substituting the variations of dimensionless parameters into the these exact solutions, the characteristics of these response are investigated.

Flow Boiling Heat Transfer Characteristics of Liquid Nitrogen in Plain and Wire Coil Inserted Tubes (평활관 및 와이어코일을 삽입한 열전달촉진관에서 액체질소의 흐름비등열전달 특성)

  • Hwang Jee-Sang;Yun Rin;Kim Yongchan;Chung Jin Taek
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.8 s.239
    • /
    • pp.927-933
    • /
    • 2005
  • Boiling heat transfer characteristics of liquid nitrogen in a stainless steel plain tube and wire coil inserted tubes were investigated. The test tubes, which had an inner diameter of 10.6 m and a length of 1.65 m, were horizontally located. Five wire coils having different pitch and thickness were inserted into the plain tube. The pitches of the wire coils were 18.4, 27.6, and 36.8 m, and the thickness was 1.5, 2.0, and 2.5 mm respectively. Tests were conducted at a saturation temperature of $-191^{\circ}$, mass fluxes from 58 to 105 kg/$m^2s$, and heat fluxes from 22.5 to 32.7 kw/$m^2$. A direct heating method was used to apply heat to the test section. The boiling heat transfer coefficients of liquid nitrogen were represented as a function of vapor quality, which showed significant drop at the dryout vapor quality. The maximum heat transfer enhancement using the wire coil inserted tubes over the plain tube was $174\%$ for 'Wire 3' having a thickness of 2.5 mm and a pitch of 18.4 mm.

Experimental study on convective boiling heat transfer for pure refrigerants and refrigerant mixtures in a horizontal tube (순수 및 혼합냉매의 원관내 증발열전달 실험)

  • Sin, Ji-Yeong;Kim, Min-Su
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.2
    • /
    • pp.730-740
    • /
    • 1996
  • Boiling heat transfer coefficients of pure refrigerants (R22, R32, R134a, R125, R290, and R600a) and refrigerant mixtures (R32/Rl34a, R290/ R600a, and R32/R125) are measured experimentally and compared with Chen's correlation. The test section is a seamless stainless steel tube with inner diameter of 7.7mm and uniformly heated by applying electric current directly to the tube. Heat fluxes range from 10 to 30kW$^2$. Mass fluxes are set to 424 ~ 742kg/m$^{2}$s for R22, R32, R134a, R32/R134a, and R32/Rl25 ; 265 ~ 583kg/m$^{2}$s for R290, R600a, and R290/R600a. Heat transfer coefficients depend strongly on heat flux at a low quality region and become independent as quality increases. Convective boiling term in the Chen's correlation predicts experimental data of the pure refrigerants fairly well (relative error of 12.1% for the data of quality over 0.2). The correlation for pure substances overpredicts the heat transfer coefficients for nonazeotropic refrigerant mixtures.

Measurement of Radiative Heat Flux Using Plate Thermometer (판열유속계를 이용한 복사열유속 측정 실험)

  • Park, Won-Hee;Yoon, Kyung-Beom
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.1
    • /
    • pp.95-98
    • /
    • 2013
  • Plate thermometers are used for measuring the radiative heat flux in high-temperature surroundings. The heat flux is calculated from the temperature measured at the back surface of the stainless steel surface of the meter. Heat fluxes from a Schmidt-Boelter gauge are measured as reference heat fluxes. A combined conductive coefficient is introduced to consider the heat loss to insulation, conduction through the stainless plate depth, and conduction from the non-uniform temperature of the plate of the plate thermometer. This coefficient is obtained using the repulsive particle swarm optimization.

Flow Condensation Heat Transfer Characteristic of R245fa in a Horizontal Plain Tube (수평 평활관내 R245fa의 흐름 응축 열전달 특성)

  • Park, Hyun-Shin;Park, Ki-Jung;Jung, Dong-Soo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.2
    • /
    • pp.87-96
    • /
    • 2008
  • Flow condensation heat transfer coefficients(HTCs) of R123 and R245fa are measured in a horizontal plain tube. The main test section in the experimental flow loop is made of a plain copper tube of 9.52 mm outside diameter and 530 mm length. The refrigerant is cooled by passing cold water through an annulus surrounding the test section. Tests are performed at a fixed saturation temperature of $50\;{\pm}\;0.2\;^{\circ}C$ with mass fluxes of 50, 100, $150\;kg/m^2s$ and heat flux of $7.3{\sim}7.7\;kW/m^2$. Heat transfer data are obtained in the vapor quality range of $10{\sim}90%$. Test results show that the flow condensation HTCs of R245fa are overall 7.9% higher than those of R123 at all mass fluxes. The pressure drop of R245fa is smaller than that of R123 at the same heat flux. In conclusion, R245fa is a good candidate to replace ozone depleting R123 currently used in chillers from the view point heat transfer and environmental properties.