• Title/Summary/Keyword: Heat fluxes

Search Result 366, Processing Time 0.024 seconds

Evaluation of Air-side Friction Characteristics on Design Conditions of Slit Fin and Tube Heat Exchanger (슬릿휜-관 열교환기의 설계조건에서 공기측 압력강하 산출)

  • Cho, Sung-Chul;Kim, Chang-Duk;Kim, Chang-Eob;Kwon, Jeong-Tae;Lim, Hyo-Jae
    • Journal of Energy Engineering
    • /
    • v.16 no.3
    • /
    • pp.149-154
    • /
    • 2007
  • An experimental study on the air-side pressure drop of slit fin-tube heat exchanger has been carried out. The data reduction methodology for air-side pressure drop in the literature is not based on a consistent approach. This paper focuses on method of data reduction to obtain the air-side performance of fin-tube heat exchanger using R22 and recommends standard procedures for dry and wet surface pressure drop estimation in fin-tube heat exchanger. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the air-side pressure drop on design conditions of condenser and evaporator. Results are pre-sented as plots of friction f-factor against Reynolds number based on the fin collar outside diameter and compared with previous studies. The data covers a range of refrigerant mass fluxes of $150{\sim}250\;kg/m^2s$ with air flows at velocity ranges from 0.38 m/s to 1.6 m/s.

A Combustion Characteristic Analysis of Quercus Variabilis and Pinus Densiflora Fallen Leaves Using Radiation Heat Flux (복사열을 이용한 소나무와 굴참나무 낙엽의 연소특성 분석)

  • Park, Hyung-Ju;Kim, Eung-Sik;Kim, Jang-Hwan;Kim, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.21 no.3
    • /
    • pp.41-46
    • /
    • 2007
  • The combustion characteristics of surface forest fire fuels was analysed using variable external irradiation level. The characteristics such as ignition time, ignition temperature, critical heat flux and mass loss rate were measured. Fuel samples were exposed to incident heat fluxes from 8 to $50\;kW/m^2$. For the measurement of various combustion characteristics, the size of specimen holder was $100\;mm{\times}100\;mm{\times}12\;mm$ and the fuel samples grinded by electric mill were the fallen leaves of Quercus variabilis and Pinus densiflora. As results, the occurrence of ignition is possible to the heat flux more than $9\;kW/m^2$. The fuel of Pinus densiflora keeps its high temperature longer than that of Quercus variabilis during the combustion process. The results of measurement shows that the maximun and average mass loss rate of Quercus variabilis larger than that of Pinus densiflora.

Experimental Study for Evaporation Heat Transfer and Pressure Drop of R-22 and R-407C in an Inner Diameter of 4.3 mm and 6.4 mm (내경 4.3 mm와 6.4 mm관내 R-22와 R-407C의 증발 열전달과 압력강하에 관한 실험연구)

  • Son, Chang-Hyo;Roh, Geon-Sang
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.3
    • /
    • pp.43-49
    • /
    • 2008
  • The evaporation heat transfer coefficient and pressure drop of R-22 and R-407C in horizontal copper tubes were investigated experimentally. The main components of therefrigerant loop are a receiver, a compressor, a mass flow meter, a condenser and a double pipe type evaporator (test section). The test section consists of a smooth copper tube of 4.3 mm and 6.4 mm inner diameter. The refrigerant mass fluxes were varied from 100 to $300[kg/m^2s]$ and the saturation temperature of evaporator were 5 [$^{\circ}C$]. The evaporation heat transfer coefficients of R-22 and R-407C rise with the increase in mass flux and vapor quality. The evaporation heat transfer coefficient of R-22 for inner diameter tube of 4.3 mm and 6.4 mm is about $7.3{\sim}47.1%$ and $5.68{\sim}46.6%$ higher than that of R-407C, respectively.

  • PDF

P=Comparative Analysis of Thermal Performance According to Combines of Multi-layer Insulating Curtain (다겹보온커튼의 조합에 따른 열성능의 비교 분석)

  • Jin, B.O.;Kim, H.K.;Ryou, Y.S.;Lee, T.S.;Kim, Y.H.;Oh, S.S.;Moon, J.P.;Kang, G.C.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.20 no.6
    • /
    • pp.763-769
    • /
    • 2018
  • In this research, in order to improve the heat retention of greenhouse, comparative analysis of the heat flux of the marketed multi-later insulating curtain was carried out. Experiments is conducted by fabricating a test apparatus for investigating the heat flux characteristics. The multi-later insulating curtain used for the experiment was compared using the P, N, S, U and T company, which are commercially available, and the heat flux due to temperature difference between the experimental apparatus and the outside was compared and analyzed. When the internal temperature of the experimental result is the maximum temperature $60^{\circ}C$, the heat flux of multi-later insulating curtain is T Co.($73.1W/m^2$) > S Co.($119.5W/m^2$) > U Co.($155W/m^2$) > N Co.($163.1W/m^2$) > P Co.($177.7W/m^2$). The heat flux means the quantity of heat passing through the unit time per unit area, and the higher the numerical value, the higher the quantity of heat passing through the multi-layer insulating curtain. This can be determined that high heat fluxes produce low heat resistance. Further, it has been found that the weight of the insulating curtain is largely unrelated to the heat insulating property, and the heat insulating curtain having a thickness containing a high internal air layer is excellent in the heat insulating property. In the future when manufacturing a heat insulating curtain, It is judged that it is desirable to manufacture a combination of heat insulating materials that contain a high internal air layer content and that can maintain the air layer even for long-term use while minimizing the volume.

Surface Flux Measurements at King Sejong Station in West Antarctica: II. Turbulent exchanges of sensible heat and latent heat in the austral summer of 2002-2003 (남극 세종기지에서의 지표 플럭스 관측: II. 2002-2003년 남반구 여름 기간의 열과 수증기의 난류 교환)

  • Choi, Tae-Jin;Lee, Bang-Yong;Lee, Hee-Choon;Kim, Seong-Joong;Hong, Sung-Min
    • Journal of the Korean Geophysical Society
    • /
    • v.8 no.3
    • /
    • pp.159-167
    • /
    • 2005
  • Turbulent fluxes of sensible heat and latent heat were analyzed at King Sejong station in the austral summer of 2002 (December) and 2003 (January and February). Monthly mean air temperatures of January and February (2.2oC) were similar to those averaged over 1988 to 2001. Precipitation was less in January and greater in February than those averaged over last 14 years. In December of 2002 and January, there was precipitation primarily when easterly wind blew usually. The frequency of snowfall was equal to or larger than that of rainfall. In the mean while, precipitation primarily in forms of rainfall occurred with westerly wind in February. In addition, while for easterly wind, temperature and humidity was low, temperature and humidity were high in case of westerly wind. Based on flux footprint, measured flux mainly came from within 300 m with maximum of 40 m upwind, indicating the insignificant role of the sea around the study site. Half-hourly downward short wave radiation amounted up to ∼ 1000 Wm-2 and net radiation ranged from -50 to 600 Wm-2. Half-hourly sensible heat flux was positive at daytime with maximum of ∼ 400 Wm-2, except the 27th and 28th in February of 2003 when it was negative all day despite of positive net radiation at short daytime. Latent heat flux was positive with maximum of ∼ 130 Wm-2. Depending on wind direction, the partitioning of net radiation into the sum of sensible heat flux and latent heat flux was larger than 0.8, indicating the strong source of the land surface for the atmospheric heating. The daytime averaged Bowen ratio (=sensible heat flux /latent heat flux) was significantly greater than 1, indicating that sensible heat flux was the main source to heat the atmosphere over the site.

  • PDF

Effect of a non-absorbable gag on the absorption process in a vortical tube absorber (수직원관형 흡수기의 흡수과정에 미치는 비흡수가스의 영향)

  • 허기준;정은수;정시영
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.456-465
    • /
    • 1998
  • Effect of a non-absorbable gas on the absorption process in a vertical tube absorber was investigated numerically. The water vapor mined with air as the non-absorbable gas is absorbed into LiBr/water solution film. The flow is assumed to be laminar and fully developed in both liquid and gas phases. The diffusion and energy equations were solved in both phases to give the temperature and concentrations, from which heat and mass fluxes were determined. It was shown that the local absorption rate decreases as the mass fraction of air in water vapor increases. The vapor pressure of water at the liquid-vapor interface reduces significantly since the non-absorbable gas is accumulated near the interface. The effect of non-absorbable gases on absorption rate becomes larger as the mass flow rate of the vapor decreases. For small amount of non-absorbable gases the total absorption rate of water vapor increases as the mass flow rate of the vapor decreases. Total absorption rate increases as the mass flow rate of the vapor increases for large concentration of non-absorbables at the inlet of an absorber.

  • PDF

ANALYSIS OF RAYLEIGH-BENARD NATURAL CONVECTION (Rayleigh-Benard 자연대류 유동 해석)

  • Choi, Seok-Ki;Kim, Seong-O
    • Journal of computational fluids engineering
    • /
    • v.13 no.3
    • /
    • pp.62-68
    • /
    • 2008
  • This paper reports briefly on the computational results of a turbulent Rayleigh-Benard convection with the elliptic-blending second-moment closure (EBM). The primary emphasis of the study is placed on an investigation of accuracy and numerical stability of the elliptic-blending second-moment closure for the turbulent Rayleigh-Benard convection. The turbulent heat fluxes in this study are treated by the algebraic flux model with the temperature variance and molecular dissipation rate of turbulent heat flux. The model is applied to the prediction of the turbulent Rayleigh-Benard convection for Rayleigh numbers ranging from Ra=$2{\times}10^6$ to Ra=$10^9$ and the computed results are compared with the previous experimental correlations, T-RANS and LES results. The predicted cell-averaged Nusselt number follows the correlation by Peng et al.(2006) (Nu=$0.162Ra^{0.286}$) in the 'soft' convective turbulence region ($2{\times}10^6{\leq}Ra{\leq}4{\times}10^7$) and it follows the experimental correlation by Niemela et al. (2000) (N=$0.124Ra^{0.309}$) in the 'hard' convective turbulence region ($10^8{\leq}Ra{\leq}10^9$) within 5% accuracy. This results show that the elliptic-blending second-moment closure with an algebraic flux model predicts very accurately the Rayleigh-Benard convection.

Effects of a Non-absorbable Gas on the Absorption Process in a Vertical Tube Absorber

  • Hur, ki-Joon;Jeong, Eun-Soo;Jeong, Si-Young
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.7
    • /
    • pp.69-78
    • /
    • 1999
  • Effects of a non-absorbable gas on the absorption process in a vertical tube absorber has been investigated numerically. The water vapor mixed with air is absorbed into LiBr/water solution film. The flow is assumed to be laminar and fully developed in both liquid and gas phases. The diffusion and energy equations were solved in both phases to give the temperature and concentrations, from which heat and mass fluxes were determined. The local absorption rate has been shown to decrease as the mass fraction of air in the water vapor increases. The vapor pressure of water at the liquid-vapor is interface reduced significantly since the non-absorbable gas accumulates near the interface. The effects of non-absorbable gases on absorption rate become larger as the mass flow rate of the vapor decreases. For a small amount of non-absorbable gases, the total absorption rate of water vapor increases as the mass flow rate of the vapor decreases. The total absorption rate increases as the mass flow rate of the vapor increases for large concentrations of non-absorbable gases at the inlet of an absorber.

  • PDF

Development of a solar flux model for thermal load prediction of a launch vehicle (발사체 열부하 예측을 위한 태양열 모델 개발)

  • Kim, Seong-Lyong;Kim, In-Sun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.35 no.9
    • /
    • pp.826-835
    • /
    • 2007
  • Solar heat flux data is needed for thermal load prediction of launch vehicle. In order to predict the solar flux, several solar flux models have been compared and a new model is developed. Most of the models can predict well the direct solar flux, but show some errors in the scattered solar flux. The newly developed model considered isotropic and anisotropic scattered solar fluxes, and the predicted solar flux agreed well with the measured. Because the present model can be used at any longitude, latitude, day and altitude, the model would be an useful tool to predict the thermal load of the launch vehicle and the vehicles which have to consider the solar heat.

ANALYSIS OF RAYLEIGH-BENARD NATURAL CONVECTION WITH THE SECOND-MOMENT TURBULENCE MODEL (이차모멘트 난류모델을 사용한 Rayleigh-Benard 자연대류 유동 해석)

  • Choi, Seok-Ki;Kim, Seong-O
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03a
    • /
    • pp.111-117
    • /
    • 2008
  • This paper reports briefly on the computational results of a turbulent Rayleigh-Benard convection with the elliptic-blending second-moment closure (EBM). The primary emphasis of the study is placed on an investigation of accuracy and numerical stability of the elliptic-blending second-moment closure for the turbulent Rayleigh-Benard convection. The turbulent heat fluxes in this study are treated by the algebraic flux model with the temperature variance and molecular dissipation rate of turbulent heat flux. The model is applied to the prediction of the turbulent Rayleigh-Benard convection for Rayleigh numbers ranging from $Ra=2{\times}10^6$ to $Ra=10^9$, and the computed results are compared with the previous experimental correlations, T-RANS and LES results. The predicted cell-averaged Nusselt number follows the correlation by Peng et al.(2006) ($Nu=0.162Ra^{0.286}$) in the 'soft' convective turbulence region ($2{\times}10^6{\leq}Ra{\leq}4{\times}10^7$) and it follows the experimental correlation by Niemela et al. (2000) ($Nu=0.124Ra^{0.309}$) in the 'hard' convective tubulence region ($10^8{\leq}Ra{\leq}10^9$) within 5% accuracy. This results show that the elliptic-blending second-moment closure with an algebraic flux model predicts very accurately the Rayleigh Benard convection.

  • PDF