• Title/Summary/Keyword: Heat extraction rate

Search Result 56, Processing Time 0.023 seconds

Active components delivery rate from acrylic resin maxillary surgical obturator: Part I

  • Al-Kaabi, Arshad;Hamid, Mohammed A.
    • Advances in materials Research
    • /
    • v.9 no.2
    • /
    • pp.109-114
    • /
    • 2020
  • The purpose of this study was to observe the trend of compounds release from acrylic resin oral prosthesis when used for drug delivery as well as a restoration. In this study, 10 specimens of heat-cured polymethylmethacrylate material were prepared and loaded with methylene blue biological stain. The specimens were then submerged in vials with 5 ml distilled water for 24 hours. The extraction procedure continued for 4 days, each day the specimens were immersed in another 5 ml distilled water vial. All extracted solutions were analyzed by visible light spectroscopy for absorbance comparison. The statistical results showed that the absorbance values were significantly different in the first day of extraction than the following days. However, there was no statistical difference among the 2nd, 3rd and 4th days of extraction. Biological stain loading to acrylic resin at the mixing stage, and then after extraction in distilled water, showed a burst release during the first day followed by a constant release during the following few days.

The Study of Restoration Technique of Wax-Treated Volume for the Annals of the Joseon Dynasty (III) -Evaluation of Durability of Korean Traditional Paper using Moist-heat Aging Treatment- (조선왕조실록 밀랍본 복원기술 연구(제3보) -습열열화처리를 이용한 복원용 한지의 내구성 평가-)

  • Jeong, Seon-Hwa;Jeong, Sun-Young;Seo, Jin-Ho;Jeong, So-Young
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.45 no.5
    • /
    • pp.49-55
    • /
    • 2013
  • To explore the paper materials for restoration of the Annals of the Joseon Dyansty, durability of the three type of the traditional Korean Papers were estimated in this study, through moist heat artificial aging test. Three types(D, F, and G) which showed the best preservation performance in dry heat and UV treatment in the previous study were selected and artificial accelerated aging treatment with moist-heat process was conducted; the viscosity change rate was D>G>F; folding endurance G>D>F; $L^*$ value F>D>G; $a^*$ and $b^*$ change rate D>G>F; brightness decrease rate D>G>F, suggesting paper F showed the least change rate in physical/optical properties. Also the CLSM image observation showed fair coherence among fibers and confirmed paper mulberry. And in FDI extraction from each sample, paper F showed the highest value. Overall, paper F (traditional glossy paper) showed the highest stability against thermal treatment. It confirms that paper F is suitable as restoration paper for tributary remains including the annals of the Joseon Dynasty for its steady strength/viscosity decrease rate and color change rate.

Thermal Energy Extraction from Phase Change Material - by Means of Finned Thermosyphon - (상변화 물질로부터의 열에너지 추출에 관한 연구 - 핀이 부착된 열싸이폰 이용에 관하여 -)

  • Mok, Jai-Kyun;Yoo, Jai-Suk;Kim, Ki-Hyun
    • Solar Energy
    • /
    • v.8 no.1
    • /
    • pp.5-12
    • /
    • 1988
  • One of the effective means to transfer the heat into and from the energy storage medium is thermosyphon. In this study, a two-phase closed thermosyphon with circular fins was used to extract the thermal energy stored in paraffin wax (Sunoco p-116). Heat transfer characteristics along the heat flow path were investigated as well as the overall performance. Some of the important results are as follows: (1) The temperature distribution of the wax in the radial direction was always maintained fairly uniformly; (2) Compared with bare thermosyphon, the heat transfer rate was vastly improved in the early stage of the experiment; and (3) Heat transfer coefficient between the wax and evaporating section of thermosyphon remained nearly constant during the experiment.

  • PDF

Optimization of blue berry extraction for beverage production using enzyme treatment (효소처리에 의한 블루베리 음료 생산을 위한 최적추출조건)

  • Ji, Yu-Jeong;Im, Moo-Hyeog
    • Food Science and Preservation
    • /
    • v.24 no.1
    • /
    • pp.60-67
    • /
    • 2017
  • In this study, we tried to establish the best method for fresh blueberry beverage production using enzyme treatment as well as low temperature extraction. During extraction of physiologically functional materials, we used low temperature to prevent nutritional loss by heat. In addition, we investigated optimal blueberry extraction conditions using various enzyme treatments (cellulase, pectinase, cellulase:pectinase (1:1) mixture) to increase extraction efficiency and reduce turbidity. A variety and ratio of enzymes, extraction temperature, extraction time, and shaking speed were considered for the best extraction efficiency rate. We observed high extraction efficiency rates of 85.72-86.55% and 87.06-87.93%, respectively, upon cellulase or pectinase treatment. In addition, a mixture of cellulase:pectinase (1:1) showed an extraction efficiency rate of 86.84-88.14%. The best extraction efficiency rate was observed when crude blueberry was treated at $45^{\circ}C$ (87.91%), for 3 h (87.88%), in a 90 rpm shaker (89.19%). Sugar content and acidity of blueberry extract were not affected by the various treatments. However, total phenolic compounds were detected upon pectinase treatment (18.62 mg/g). Only fructose and glucose as free sugars were found in all samples regardless of treatments and extraction conditions.

An Experimental Study on the Cooling and Heating Performance of a Residential Ground Source Heat Pump System (가정용 지열원 열펌프 시스템의 냉난방 성능 특성 연구)

  • Kong, Hyoung Jin;Kang, Sung Jae;Yun, Kyoung Sik;Lim, Hyo Jae
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.25 no.3
    • /
    • pp.156-163
    • /
    • 2013
  • Ground Source Heat Pump (GSHP) systems utilize geothermal energy as a thermal source or sink, for heating, cooling and domestic hot water. It is well known that GSHP is environmentally friendly, and saves energy dramatically. For this reason, many investigative researches have been conducted on commercial and governmental buildings. However, studies on residential GSHP are few, because of the small capacity and cost. In this study, we experimented with the characteristic performance of heating, cooling and seasonal performance factor for a residential GSHP system, which consisted of two 180 m deep u-tube ground heat exchangers, a heat pump and measurement instruments. The installed capacity of the heat pump was 5RT, and the conditioning area was $62.23m^2$. From the experimental results, the cooling COP of the heat pump was 4.13, and the system COP was 3.51, while the CSPF was 3.32. On the other hand, the heating COP of the heat pump was 3.87, and the system COP was 3.39, while the HSPF was 3.39. Also, in-situ cooling COP and capacity were 93.7% and 96.4% compared with the EWT certification data, respectively, and that of heating were 98.3% and 95.7%, respectively.

An Experimental Study on the Performance of Heat Pump Assisted Batch Dryer Using HFC134a (HFC134a를 사용한 열펌프 건조기의 성능에 관한 실험적 연구)

  • Kim, Y.J.;Yim, C.S.
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.3-11
    • /
    • 1997
  • In conventional heat and vent dryer, both sensible and latent heat could not be recovered from the exhaust air, but this problem could be solved by introducing a heat pump to a conventional dryer, having a connection with cooling, dehumidifying and heating of heat pump. In this work, HFC134a as a substitute refrigerant of CFC12 adopted in heat pump and a batch type is also introduced. The variables affected on the system performance are holding temperature of a drying chamber, bypass air ratio, degree of superheat and refrigerant flowrate, etc. The moisture contents were decreased curvilinearly in the range of $86{\sim}75%$ on the wet basis. Under the constant drying temperature, the face velocity plays an important role to the drying performance. The COPs are increased in accordance with the air velocity, on the other hand the SMERs are gradually decreased.

  • PDF

Study on the Thermal Characteristics of Organic Rankine Cycles for Use of Low-Temperature Heat Source (저온열원 활용을 위한 유기랭킨사이클의 열적 특성에 관한 연구)

  • Jin, Jae-Young;Kim, Kyoung-Hoon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.04a
    • /
    • pp.191-194
    • /
    • 2011
  • Low-grade waste heat has generally been discarded in industry due to lack of efficient recovery methods. In recent years, organic Rankine cycle(ORC) has become a field of intense research and appears as a promising technology for conversion of heat into useful work of electricity. In this work thermodynamic performance of ORC with superheating of vapor is comparatively assessed for various working fluids. Special attention is paid to the effects of system parameters such as the evaporating temperature on the characteristics of the system such as maximum possible work extraction from the given source, volumetric flow rate per 1 kW of net work and quality of the working fluid at turbine exit as well as thermal efficiency.

  • PDF

Simulation for the effect of vertical groundwater flux on the subsurface temperature distribution

  • Shin Ji-Youn;Lee Kang-Kun
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2006.04a
    • /
    • pp.383-386
    • /
    • 2006
  • Subsurface temperature is affected by heat advection due to groundwater advection. Temperature-depth profile can be perturbed especially when there are significant vertical groundwater flux caused by external force such as injection or extraction. This research is to clarify the change of subsurface temperature distribution when the 40m x l0m sandy aquifer is stimulated by two different vertical flux($case1:\;{\pm}10^{-5}m^3/s,\;case2:\;{\pm}4{\times}10^{-5}m^3/s$) using a program called HydroGeoSphere. The resulting temperature distribution contour map shows pumping causes vertical attraction of water from deeper and warmer place which result in rising up isotherm. Additionally more injection/extraction rate, more vertical groundwater flux leads to faster Increase in temperature near the pumping well.

  • PDF

A Study on Horizontal Ground Source Heat Pump Systems (수평형 지열원 히트펌프 시스템에 관한 연구)

  • Park, Yong-Jung;Kim, Kyoung-Hoon
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.160-165
    • /
    • 2006
  • Ground source heat pump (GSHP) or geothermal heat pump systems (GHPs) are recognized to be outstanding heating and cooling systems. Most of GSHP systems installed and studied in korea are vertical GSHP systems. A horizontal GSHP system was installed in greenhouse and investigated for the performance characteristics. The results of the study showed that the heating coefficient of performance of the heat pump was 3.64 and the overall heating coefficient of performance of the system was 3.31. The pumping power was obtained as 28.0 W/kW and the required ground heat exchanger length was 53.3 m/kW of rejection heat of condenser. The heat extraction rate was, on average, 14.58 W/m of ground heat exchanger length and trench length is 27.7 m/kW of rejection heat of condenser.

Experimental Study on Thicknesss of Heat Storage Zone in Small Solar Pond (소형실험태양(小型實驗太陽)연못에서 열저장층(熱貯藏層)의 두께에 관(關)한 실험적(實驗的) 연구(硏究))

  • Pak, Ee-Tong;Seo, Ji-Weon
    • Solar Energy
    • /
    • v.7 no.2
    • /
    • pp.22-29
    • /
    • 1987
  • This paper dealed with thickness variation of bottom heat sotrage zone due to salinity and flow rate of extration hot brine in small test solar pond (0.5m wide, 0.5m high, 1.0m long). Testing apparatus and situation were follows: 7.1 cm of height of suction diffuser and 1.8cm of height of discharge diffuser above the test pond respectively, 0.3cm of slot size of suction diffuser, 1.0cm of slot size of discharge diffuser, 47cm of length of the slot; heating of hot water ($75^{\circ}C$) through separated hot water tank, discharge of the brine into storage zone through discharge diffuser, the extration of the brine through suction diffuser, circulation of the extracted brine through a heat exchanger (cooler). Following results were obtained through the experiments. 1. In small test solar pond, the typical three zone which showed up in real solar pond were established. 2. Richardson Number was used more effectively to confirm hydrodynamic stability of the stratified flow. 3. The thickness of non convective layer had a great effect on the heat storage of the bottom convective layer, then the temperature of bottom convective layer had a relation to that of upper convective layer. 4. Optimum operating condition in the test pond was on 10%-15% of salt concentration and $0.05m^3/hr$ of flow rate of extraction hot brine. 5. Following thickness of 3 zones were available to obtain under optimum operation condition: o bottom storage zone: $30%{\pm}10%$ of total pond depth o non-convective zone: $40%{\pm}10%$ of total pond depth o Upper surface zone: $20%{\pm}10%$ of total pond depth.

  • PDF