• Title/Summary/Keyword: Heat exchanger performance

Search Result 1,176, Processing Time 0.023 seconds

Computational Fluid Dynamics Model for Solar Thermal Storage Tanks with Helical Jacket Heater and Upper Spiral Coil Heater (상부 코일히터를 갖춘 나선재킷형 태양열 축열조의 성능예측을 위한 CFD 해석모델 개발 및 검증)

  • Baek, Seung Man;Zhong, Yiming;Nam, Jin Hyun;Chung, Jae Dong;Hong, Hiki
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.4
    • /
    • pp.331-341
    • /
    • 2013
  • In a solar domestic hot water (SDHW) system, solar energy is collected using collector panels, transferred to a circulating heat transfer fluid (brine), and eventually stored in a thermal storage tank (TST) as hot water. In this study, a computational fluid dynamics (CFD) model was developed to predict the solar thermal energy storage in a hybrid-type TST equipped with a helical jacket heater (mantle heat exchanger) and an immersed spiral coil heater. The helical jacket heater, which is the brine flow path attached to the side wall of a TST, has advantages including simple system design, low brine flow rate, and enhanced thermal stratification. In addition, the spiral coil heater further enhances the thermal performance and thermal stratification of the TST. The developed model was validated by the good agreement between the CFD results and the experimental results performed with the hybrid-type TST in SDHW settings.

DEVELOPMENT OF CCD IMAGING SYSTEM USING THERMOELECTRIC COOLING METHOD (열전 냉각방식을 이용한 극미광 영상장비 개발)

  • Park, Young-Sik;Lee, Chung-Woo;Jin, Ho;Han, Won-Yong;Nam, Uk-Won;Lee, Yong-Sam
    • Journal of Astronomy and Space Sciences
    • /
    • v.17 no.1
    • /
    • pp.53-66
    • /
    • 2000
  • We developed low light CCD imaging system using thermoelectric cooling method collaboration with a company to design a commercial model. It consists of Kodak KAF-0401E(768$\times$512 pixels) CCD chip, thermoelectric module manufactured by Thermotek. This TEC system can reach an operative temperature of $-25^{\circ}C$. We employed an Uniblitz VS25s shutter and it has capability a minimum exposure time 80ms. The system components are an interface card using a Korea Astronomy Observatory (hereafter KAO) ISA bus controller, image acquisition with AD9816 chip, that is 12bit video processor. The performance test with this imaging system showed good operation within the initial specification of our design. It shows a dark current less than 0.4e-/pixel/sec at a temperature of $-10^{\circ}C$, a linearity 99.9$\pm$0.1%, gain 4.24e-/adu, and system noise is 25.3e-(rms). For low temperature CCD operation, we designed a TEC, which uses a one-stage peltier module and forced air heat exchanger. This TEC imaging system enables accurate photometry($\pm$0.01mag) even though the CCD is not at 'conventional' cryogenic temperatures(140k). The system can be a useful instrument for any other imaging applications. Finally, with this system, we obtained several images of astronomical objects for system performance tests.

  • PDF

Pellet Made of Agricultural By-product and Agricultural Pellet Boiler System (농림부산물 원료 펠릿 및 농업용 펠릿 난방기)

  • Kang, Y.K.;Ryou, Y.S.;Kcang, G.C.;Kim, J.G.;Kim, Y.H.;Jang, J.K.;Lee, H.M.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.252.2-252.2
    • /
    • 2010
  • Biomass is considered to be a major potential fuel and renewable resource for the future. In fact, there is high potential to produce the large amount of energy from biomass around the world. In this study, to obtain basic data for practical application of wood pellet and wood pellet boiler system as heating system in agriculture, agricultural biomass resources were surveyed, pellet was made of agricultural by-product such as stem of rape, oat and rice, ricehusk and sawdust and wood pellet boiler system with capacity of 116 kW was manufactured and installed in greenhouse of $38.5m{\times}32m$. High heating value, bulk density and ash content of pellet made of agricultural by-product and efficiency and heating performance of this system was estimated. Rice straw was the largest agricultural biomass in 2005 and the total amount of rice straw converted into energy of $131.71{\times}10^{11}$ kJ. And in 2005, total amount of forest' by-product converted into energy of $29,277.05{\times}10^{11}$ kJ. High heating values of pellets made of agricultural by-products of stem and seed of rape, stem of oat, rice straw and rice husk were 16,034, 16,026, 16,089, 15,650, 15,044 kJ/kg respectively. High heating values of pellets made of agricultural by-products were 83.6% compared to that of wood pellet. Average bulk density of pellets made of agricultural by-products of stem and seed of rape, stem of oat, rice straw and rice husk was 1,400 $kg/m^3$. Ash contents of the pellets were 6.6, 7.0, 6.2, 5.5, 33% respectively. Ash content of rice husk pellet was the largest compared to other kind of pellets. To increase efficiency of agricultural pellet boiler, the boiler adopted secondary heat exchanger. The agricultural pellet boiler designed and manufactured in this study had high efficiency of 84.2% compared to the conventional agricultural pellet boiler, when water flow rate, exhaust gas temperature and average combustion furnace temperature were 39L/min, $180^{\circ}C$, $680^{\circ}C$ respectively. And pellet supplying and pausing time were 13, 43 seconds respectively. In March of 2010, prices of wood pellet, agricultural tax free diesel, diesel, kerosene were 350 won/kg, 811 won/L, 1,422 won/L, 976 Won/L respectively. Also in terms of energy, prices per same heating value were 77.8, 90.1, 158, 108.4 Won/Mcal. Energy saving rate of wood pellet was 16, 50, 39% compared to agricultural tax free diesel, diesel and kerosene respectively.

  • PDF

The Effects of Scale Growth Inhibition on Water Pipe using Frequency Driver (Frequency Driver를 이용한 냉온수관의 스케일 방지억제효과)

  • Jang, Mi-Jeong;Sung, Il-Wha
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.4
    • /
    • pp.258-266
    • /
    • 2011
  • Scale induced by hardness materials in water must be controled because of it can be result in remarkable damages of pipeline as well as water quality deterioration. Especially hot water system is one of scale management required facility as scale formation can be accelerated by temperature. The scale control performance of frequency driver (FD) was tested instead of existing methods such as chemical, physical and electromagnetic methods which needs chemicals and electric power. Three kinds of pipe coupons were submerged in test water with 500 mg/L of hardness for 33 days and XRD and SEM were analysed for comparing scale formation characteristics of these coupons. Calcite ($CaCO_3$) which came from hardness of water was formed on only cast iron pipe coupon and this coupon showed higher corrosion rate than copper and stainless steel pipe coupon. Hot water circulating system connected cast iron pipe with and without FD was operated with 300 mg/L of hardness water at $50^{\circ}C$ for monitoring of scale formation and water quality with and without FD. XRD showed that FD leaded to magnetite ($Fe_3O_4$) scale which is good scale for preventing corrosion than calcite and SEM image also indicated the scale control effect of FD. Scales of 16% on pipe joint, 14% on pipe length, and 42% on heat exchanger decreased with FD comparing scales of those parts without FD. From the results of water quality, FD reduced crystallization of hardness material without chemical reaction in water and it can indicate that FD is safe and proenvironmental technology for scale reduction.

Applicability of the Hydrocyclone for Efficiency Improvements to Sea-water Cooling Systems (해수 냉각시스템 효율 향상을 위한 하이드로사이클론의 적용가능성)

  • Kim Bu-Gi;Han Won-Hui;Cho Dae-Hwan;Choi Min-Seon
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.11 no.2 s.23
    • /
    • pp.109-115
    • /
    • 2005
  • Hydrocyclone has been widely used for the solid-liquid separation in many industrial sites because of its comparatively preferable applications that can be applied to wide-range particle sizes. If seawater with impurities flows through pumps or heat exchanger, it might cause an decrease in the efficiency of cooling system In this paper, we have suggested some methods of separating impurities from seawater in the cooling system by using a Hydrocyclone. The effects of design factors as solid concentration, cyclone inlet pressure, flow rate and diameter of underflow on the separating performance of the Hydrocyclone were investigated The results from this study are summarized as follows: 1) In proportion to the decrease of solid concentration, the efficiency of solid-liquid separation is improved. 2) According as the cyclone inlet pressure increases the efficiency of separation is improved. Conclusively, this research suggested that the Hydrocyclone will be used as a pre-treatment system of cooling water in machines, and eventually prevent unexpected accidents in engine systems.

  • PDF

Applicability of the Hydrocyclone for Efficiency Improvements to Sea-water Cooling Systems (해수 냉각시스템 효율 향상을 위한 하이드로사이클론의 적용가능성)

  • Kim Bu-Gi;Han Won-Hui;Cho Dae-Hwan;Choi Min-Sun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2004.11a
    • /
    • pp.109-115
    • /
    • 2004
  • Hydrocyclone has been widely used for the solid-liquid separation in many industrial sites because of its comparatively preferable applications that can be applied to wide-range particle sizes. If seawater with impurities flows through pumps or heat exchanger, it might cause an decrease in efficiency of cooling system. In this paper, we have suggested some methods of separating impurities from seawater in the cooling system by using a Hydrocyclone. The effects of design factors as solid concentration, cyclone inlet pressure, flow rate and diameter of underflow on the separating performance of the Hydrocyclone were investigated The results from this study are summarized as follows: 1) In proportion to the decrease of solid concentration, the efficiency of solid-liquid separation is improved 2) According as the cyclone inlet pressure increases the efficiency of separation is improved Conclusively, this research suggested that the Hydrocyclone will be used as a pre-treatment system of cooling water in machines, and eventually prevent unexpected accidents in engine systems.

  • PDF