• 제목/요약/키워드: Heat exchanger performance

검색결과 1,178건 처리시간 0.028초

ASSESSMENT OF CONDENSATION HEAT TRANSFER MODEL TO EVALUATE PERFORMANCE OF THE PASSIVE AUXILIARY FEEDWATER SYSTEM

  • Cho, Yun-Je;Kim, Seok;Bae, Byoung-Uhn;Park, Yusun;Kang, Kyoung-Ho;Yun, Byong-Jo
    • Nuclear Engineering and Technology
    • /
    • 제45권6호
    • /
    • pp.759-766
    • /
    • 2013
  • As passive safety features for nuclear power plants receive increasing attention, various studies have been conducted to develop safety systems for 3rd-generation (GEN-III) nuclear power plants that are driven by passive systems. The Passive Auxiliary Feedwater System (PAFS) is one of several passive safety systems being designed for the Advanced Power Reactor Plus (APR+), and extensive studies are being conducted to complete its design and to verify its feasibility. Because the PAFS removes decay heat from the reactor core under transient and accident conditions, it is necessary to evaluate the heat removal capability of the PAFS under hypothetical accident conditions. The heat removal capability of the PAFS is strongly dependent on the heat transfer at the condensate tube in Passive Condensation Heat Exchanger (PCHX). To evaluate the model of heat transfer coefficient for condensation, the Multi-dimensional Analysis of Reactor Safety (MARS) code is used to simulate the experimental results from PAFS Condensing Heat Removal Assessment Loop (PASCAL). The Shah model, a default model for condensation heat transfer coefficient in the MARS code, under-predicts the experimental data from the PASCAL. To improve the calculation result, The Thome model and the new version of the Shah model are implemented and compared with the experimental data.

저속 영역에서 루버휜이 장착된 평판관형 알루미늄 열교환기의 공기측 전열 성능에 대한 실험적 연구 (Air-side Performance of Louver-Finned Flat Aluminum Heat Exchangers at a Low Velocity Region)

  • 조진표;오왕규;김내현;윤백
    • 대한기계학회논문집B
    • /
    • 제26권12호
    • /
    • pp.1681-1691
    • /
    • 2002
  • The heat transfer and pressure drop characteristics of heat exchangers with louver fins were experimentally investigated. The samples had small fin pitches (1.0 mm to 1.4 mm), and experiments were conducted up to a very low frontal air velocity (as low as 0.3 m/s). At a certain Reynolds number (critical Reynolds number), the flattening of the heat transfer coefficient curve was observed. The critical Reynolds number was insensitive to the louver angle, and decreased as the louver pitch to fin pitch ratio (L$_{p}$F$_{p}$) decreased. Existing correlations on the critical Reynolds number did not adequately predict the data. It is suggested that, for proper assessment of the heat transfer behavior, the louver pattern in addition to the flow characterization need to be considered. The heat transfer coefficient increased as the fin pitch decreased. At low Reynolds numbers, however, the trend was reversed. Possible explanation is provided considering the louver pattern between neighboring fins. Different from the heat transfer coefficient, the friction factor did not show the flattening characteristic. The reason may be attributed to the form drag by louvers, which offsets the decreased skin friction at a low Reynolds number. The friction factor increased as the fin pitch decreased and the louver angle increased. A new correlation predicted 92% of the heat transfer coefficient and 90% of the friction factor within $\pm$10%.10%.

이중관 내부 나노유체의 강제대류에 관한 수치적 연구 (Numerical Study of Forced Convection Nanofluid in Double Pipe)

  • 임윤승;최훈기
    • 융합정보논문지
    • /
    • 제9권12호
    • /
    • pp.147-156
    • /
    • 2019
  • 동심 이중관에서 기본유체 물과 나노입자 산화알미늄의 혼합인 나노유체를 적용한 대향유동을 유한체적법의 수치적 방법으로 열전달 특성을 규명하였다. 고온유체는 내부 원형관으로 흐르며 열을 외부 환형관으로 흐르는 저온유체로 전달한다. 고온유체와 저온유체의 체적유량 및 나노입자의 체적농도를 변수로 두어 열전달 및 유동 특성을 조사했다. 결과는 나노입자의 체적농도와 체적유량의 증가함에 따라 열전달 성능이 증가함을 보였다. 외부와 내부 관 모두에서 나노유체인 경우가 기본유체보다 나노입자의 체적농도가 8%일 때 나노유체가 열전달 성능이 최대 17% 증가하는 것을 확인했다. 또한 기본유체에 비해 환형관의 대류열전달 계수는 최대 31% 증가함을 보였으며 열교환기의 유용도는 약 20%가 상승함을 확인하였다. 하지만 나노입자의 체적농도가 8%일때 마찰인자가 최대 136% 커지는 것을 확인하였다.

중공사막 가습에 따른 PEMFC의 성능 평가 (Performance Test of PEMFC with Hollow Fiber Membrane)

  • 이호열;천광우;박창권;오병수
    • 한국수소및신에너지학회논문집
    • /
    • 제16권1호
    • /
    • pp.82-91
    • /
    • 2005
  • Polymer membrane needs to maintain appropriate moisture. Insufficient moisture causes low conduction of hydrogen ion because of increased contact resistance between electrode and membrane by shrinking membrane, and abundant moisture decreases fuel cell performance as difficulty of diffusion reacting gas. Therefore, water controlling system is very consequential for the polymer membrane fuel cell. If hollow fiber membrane humidification is used between fuel and air lines, it is possible to supply heat to fuel and air by using thermal exchanger. It can supply appropriate humidity depending on operating temperature, and can recover heat from exhaust gas which contains water vapor and air. Because of simple structure of humidification system, this system can be easily applied in the PEMFC and cut down cost.

Volume-Junction Method를 이용한 우주왕복선 액체로켓엔진 열교환기 모델링 (Modeling of Space Shuttle Main Engine heat exchanger using Volume-Junction Method)

  • 차지형;고상호
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.213-217
    • /
    • 2017
  • 액체로켓엔진 고장에서 시동과정이 30% 이상을 차지하며 특히, 우주왕복선 주 엔진(Space Shuttel Main Engine, SSME)은 2%의 밸브위치 오차 또는 0.1초의 시간오차와 같은 작은 변화에도 급격하게 변화하는 매우 민감한 시스템으로 시동과정의 모델링이 중요하다. 하지만, 시동과정에서 비선형 질량 유량과 열전달 특성 때문에 많은 어려움이 발생한다. 본 논문에서는 이를 해결하기 위하여 부분적인 전산유체해석(Computational Fluid Dynamics, CFD) 방법을 사용하였으며 본 논문에서는 구성품의 모델링을 수행하여 정상상태에서 확인을 하였다.

  • PDF

A Numerical Study on Operating Characteristics of a Miniature Joule-Thomson Refrigerator

  • Hong, Yong-Ju;Park, Seong-Je;Choi, Young-Don
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권4호
    • /
    • pp.41-45
    • /
    • 2010
  • Miniature Joule-Thomson refrigerators have been widely used for rapid cooling of infrared detectors, optoelectronic device, and integrated circuits of micro electronics. The typical J-T refrigerator consists of the recuperative heat exchanger with the double helical tube and fin configuration, J-T nozzle, a mandrel, Dewar and a compressed gas storage bottle. In this study, to predict the thermodynamic behaviors of the refrigerator with a compressed gas storage bottle during the cool-down time, numerical study of transient characteristics for a J-T refrigerator was developed. A simplified transient one.dimensional model of the momentum and energy equations was simultaneously solved to consider the thermal interactions of the each component of the refrigerator. To account for effects of the thermal mass of the solid, the heat capacities of the tube, fins, mandrel and Dewar are considered. The results show the charged gas pressure of the gas storage bottle has significant effects on the performance of the J-T refrigerator. At the elevated gas pressure of the gas storage bottle, the large capacity of the compressed gas storage does not need to get the fast cool-down performance of the J-T refrigerator in the cool-down stage.

가정용 온수보일러의 성능향상에 관한 실험적 연구 (An Experimental Study on Performance Improvement of a Domestic Hot Water Boiler)

  • 장태현;이종붕;오건제
    • 한국산업융합학회 논문집
    • /
    • 제6권3호
    • /
    • pp.231-238
    • /
    • 2003
  • An experimental study was performed to improve a domestic hot water boiler with a coil type heat exchanger. By using Korean Standard B 8107, B 8021 and B 6205, the boiler efficiency for heating, bathing and combution are calculated. Finally, the efficiency of the boiler are compared with those of the commercial production. On the whole, the performance of the hot water generator is higher than that of the other generator.

  • PDF

Double speaker 1/2파장 열음향 냉동기의 성능 평가 (The Performance Investigation of Double-speaker-1/2 Wavelength Thermoacoustic Refrigerator)

  • 송규조;박종호;이성노
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.647-650
    • /
    • 2002
  • A thermoacoustic refrigerator, using a resonant standing acoustic wave, has been built. It employs a loudspeaker to sustain a standing wave in a resonance tube. The stack of plates is 0.075mm-thick plastic sheet(Mylar), spirally wound to make a 40mm-diameter assembly 80mm long. and two heat exchanger are installed. The refrigerant is Helium gas. The description of thermoacoustic refrigerator are presented. The directly measured performance of the resonator. Tc/Th ( temperature ratio ) and $COP/COP_{c}$, (normalized by carnot's COP ) are plotted versus the thermal load Q applied to the cold end, for various speaker power.

  • PDF

공업로용 무화염식 축열버너의 국산화 개발 (The Development of Flameless Regenerative Burner for the Industrial Furnaces)

  • 김원배;양제복
    • 한국연소학회지
    • /
    • 제15권2호
    • /
    • pp.27-33
    • /
    • 2010
  • Recently, much attention has been paid to utilizing highly preheated air up to $1,000^{\circ}C$ through waste gas in industrial furnaces. The regenerative burner technology has shown to provide significant reduction in energy consumption (up to 60%), downsizing of the equipment (about 30%) and lower emissions (about 30%) while maintaining high thermal performance of the system since 2000. The object of this study is to develop the flameless regenerative burner for industrial furnaces based on the FLOX(Flameless Oxidation) principle and it has been designed and manufactured as pilot scale. Performance tests are experimentally done and their results are discussed. They showed 1) a very good uniformity in temperature distribution, 2) about 100 ppm in NOx at the temperature $1,300^{\circ}C$, 3) about 95% in temperature efficiency. Besides, the regenerative burner has advantage in easy maintenance and high usage rate of regenerator due to the separate and portable type of heat exchanger.

캐스캐이드 냉동시스템에서 냉매로서의 프로판-에탄 냉매의 성능 분석 (The Characteristic of Propane(R290)-Ethane(R170) as Refrigerant in the Cascade Refrigeration System)

  • 김필환;이병호;정효민;정한식;김철수
    • 동력기계공학회지
    • /
    • 제11권4호
    • /
    • pp.50-55
    • /
    • 2007
  • Nowadays, demands on super low temperature condition for industrial and commercial uses are thriving. Considering of its wide application in the present and the future, study of the super-low temperature refrigeration system should be actively carried out. This study is aimed to investigate refrigeration capacity and coefficient of performance(COP) of the cascade refrigeration system, as well as to get the system which can reach evaporator temperature of $-70^{\circ}C$. For this purpose, R290 and R170 are charged in high stage and low stage respectively. Finally the characteristics of system using R290 and R170 will be proposed. Additionally, In this experiment, the flow rate of air flowing through the LS evaporator and the compressor inlet pressure were varied to investigate the refrigeration capacity and coefficient of performance characteristics.

  • PDF