• Title/Summary/Keyword: Heat exchanger method

Search Result 439, Processing Time 0.024 seconds

Study on Cooling of Hydrogen Gas for the Pre-Cooler in the Hydrogen Refueling Station (수소충전소용 프리쿨러를 위한 수소가스 냉각에 관한 연구)

  • LEE, KYUNG-HAN;KOO, KYUNG-MO;RYU, CHEOL-HWI;HWANG, GAB-JIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.30 no.3
    • /
    • pp.237-242
    • /
    • 2019
  • In the hydrogen refueling station (HRS), it is need the pre-cooling system (PCS) to limit the inside temperature ($85^{\circ}C$) of the onboard thank (700 bar) and to charge the hydrogen at short time (within 3 minutes) to fuel cell electric vehicle (FCEV). From those safety reasons, the temperature of hydrogen gas must be controled $-33^{\circ}C$ to $-40^{\circ}C$ in PCS. The cooling test of the gaseous ($N_2$, He, $H_2$) was carried out using heat exchanger (pre-cooler) by indirect cooling and direct cooling method. It was confirmed that the temperature of hydrogen gas had below $-40^{\circ}C$ at below $-75^{\circ}C$ of chiller temperature in direct cooling.

Long-term Creep Strain-Time Curve Modeling of Alloy 617 for a VHTR Intermediate Heat Exchanger (초고온가스로 중간 열교환기용 Alloy 617의 장시간 크리프 변형률-시간 곡선 모델링)

  • Kim, Woo-Gon;Yin, Song-Nam;Kim, Yong-Wan
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.10
    • /
    • pp.613-620
    • /
    • 2009
  • The Kachanov-Rabotnov (K-R) creep model was proposed to accurately model the long-term creep curves above $10^5$ hours of Alloy 617. To this end, a series of creep data was obtained from creep tests conducted under different stress levels at $950^{\circ}C$. Using these data, the creep constants used in the K-R model and the modified K-R model were determined by a nonlinear least square fitting (NLSF) method, respectively. The K-R model yielded poor correspondence with the experimental curves, but the modified K-R model provided good agreement with the curves. Log-log plots of ${\varepsilon}^{\ast}$-stress and ${\varepsilon}^{\ast}$-time to rupture showed good linear relationships. Constants in the modified K-R model were obtained as ${\lambda}$=2.78, and $k=1.24$, and they showed behavior close to stress independency. Using these constants, long-term creep curves above $10^5$ hours obtained from short-term creep data can be modeled by implementing the modified K-R model.

Numerical analysis of Poiseuille-Rayleigh-Bénard convection in supercritical carbon dioxide

  • Wang, Zhipeng;Xu, Hong;Chen, Chong;Hong, Gang;Song, Zhenguo;Zhang, Yaoli
    • Nuclear Engineering and Technology
    • /
    • v.54 no.9
    • /
    • pp.3540-3550
    • /
    • 2022
  • The supercritical carbon dioxide (S-CO2) Brayton cycle is an important energy conversion technology for the fourth generation of nuclear energy. Since the printed circuit heat exchanger (PCHE) used in the S-CO2 Brayton cycle has narrow channels, Rayleigh-Bénard (RB) convection is likely to exist in the tiny channels. However, there are very few studies on RB convection in supercritical fluids. Current research on RB convection mainly focuses on conventional fluids such as water and air that meet the Boussinesq assumption. It is necessary to study non-Boussinesq fluids. PRB convection refers to RB convection that is affected by horizontal incoming flow. In this paper, the computational fluid dynamics simulation method is used to study the PRB convection phenomenon of non-Boussinesq fluid-supercritical carbon dioxide. The result shows that the inlet Reynolds number (Re) of the horizontal incoming flow significantly affects the PRB convection. When the inlet Re remains unchanged, with the increase of Rayleigh number (Ra), the steady-state convective pattern of the fluid layer is shown in order: horizontal flow, local traveling wave, traveling wave convection. If Ra remains unchanged, as the inlet Re increases, three convection patterns of traveling wave convection, local traveling wave, and horizontal flow will appear in sequence. To characterize the relationship between traveling wave convection and horizontal incoming flow, this paper proposes the relationship between critical Reynolds number and relative Rayleigh number (r).

An Analytical Study on the Performance Analysis of a Desalination System by Condensing Method (응축방식을 이용한 담수화 시스템의 성능예측을 위한 분석연구)

  • Kim, Chul-Ho;Kim, Won-Il;Choi, Jea-Young;Kim, Jae-Choul;Kim, Min-Sun
    • Transactions of the KSME C: Technology and Education
    • /
    • v.2 no.1
    • /
    • pp.47-55
    • /
    • 2014
  • A new concept of an Eco-friendly desalination method is introduced in this study. The main idea of the desalination method of seawater is the condensation of the vaporized seawater by solar heat energy on the surface of seashore. The wind turbine blade plays a role of heat exchanger condensing the vaporized water in the air. In this analytical study, the availability of the proposed desalination system was studied. First, an analytical condensation theory of the vaporized water in air was arranged and the parametric study was conducted to estimate the amount of freshwater produced from the system with the change of the temperature difference between the humid air and turbine blade, and the relative humidity in air, and wind speed. From the analytical calculation, 2,927(ton/year) of freshwater was produced at the vertical-type wind turbine (Diameter=4m, Height=3m) as the relative humidity is 100%, the temperature difference between the impeller blade and the humid air is $40^{\circ}C$ and the wind speed is 10m/s.

Experimental Study on Corrosion and Thermal Conductivity Characteristics of Thermal Spray Coating for Sea Water Heat Exchanger (해수용 열교환기 적용을 위한 열분사 코팅의 부식 및 열전도 특성에 관한 실험적 연구)

  • Cho, Meang-Ik;Huh, Cheol;Kwon, Young-Chul;Kwon, Jeong-Tae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.12
    • /
    • pp.6098-6105
    • /
    • 2013
  • In the present study, the characteristics of corrosion and thermal conductivity of thermal spray coatings for seawater heat exchangers were examined experimentally. The coating types of theZn and Al thermal spray coatings with additional epoxy and silicone sealers were tested. To examine the corrosion characteristics of the thermal spray coating, the cyclic voltamogram curve was measured followed by SEM imaging for surface characterization. The laser flash method was usedto measure the thermal conductivity of the specimen. The conductivity test results showed that thermal conductivity decreased by3 ~ 4% with the silicone sealer and decreased by 70 ~ 75% with the epoxy sealer.

Prediction of GHP Performance Using Cycle Analysis (사이클 해석을 통한 GHP 성능 예측)

  • Cha, Woo Ho;Choi, Song;Chung, Baik Young;Kim, Byung Soon;Jeon, Si Moon
    • Transactions of the KSME C: Technology and Education
    • /
    • v.3 no.1
    • /
    • pp.15-21
    • /
    • 2015
  • In this paper a prediction method of GHP performance is proposed for increasing design accuracy. Two compressors with different capacity and 2311cc gas engine are used for prediction and the target capacity of GHP is 25HP. For predicting GHP performance at first the operation points are randomly selected and then as compared with compressor performance date and heat exchanger characteristic, more accurate operating points are decided through recursive calculation. Lastly engine performance date is used for calculating gas consumption volume. Predicting heating mode performance of GHP, evaporator is separated to the two section of absorbing heat in outdoor air and in engine. From the experimental results, it was found that the simulation model is good for the predicting GHP efficiency and the difference of predicted and measured efficiency is less than 5%.

An Experimental Study on the Noise Reduction of Cooling Fans for Four-ton Forklift Machines (4톤급 지게차 냉각홴 소음 저감에 관한 실험적 연구)

  • Choi, Daesik;Kim, Seokwoo;Yeom, Taeyoung;Lee, Seungbae
    • Journal of Drive and Control
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2021
  • This paper presents research on methods for the reduction of forklifts' noise level for the increased comfort and safety of its operator. A cooling fan with a high air volume flow rate installed in the forklift acts as an important design parameter which efficiently cools the heat exchanger system, helping to transfer internal heat from the engine room to the outdoors with both transmitted and diffracted opening noises. The cooling fan contributes significantly to both the forklift's emitted sound power and the operator room's noise level, thereby necessitating research on the forklift's reduction of acoustic power level and transmission. A noise analysis for various fan models with a biomimetic design based on eagle-wing geometry was conducted. In addition to the acoustic power generation, the aerodynamic performance of the cooling blade is also strongly influenced by the design of airfoil distribution, thereby requiring optimization. The cooling fans were fabricated and installed in the forklift in order to check the efficacy of the forklift engine's cooling, and the final version of the fan was measured for its ability to lower acoustic power level and cool the engine room. This study explains the aerodynamic and acoustic features of the designed fans with the use of BEM analysis and forklift test results.

A Numerical Analysis on Transient Fuel Temperatures in a Military Aircraft with Additional Fuel Supplies and Return (추가연료 공급,회송량에 따른 항공기내 연료온도 변화에 대한 수치해석적 연구)

  • Kim,Yeong-Jun;Kim,Chang-Nyeong;Kim,Cheol-In
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.1
    • /
    • pp.73-84
    • /
    • 2003
  • A transient analysis on fuel temperatures in an aircraft was studied using the finite difference method. Numerical calculation was performed by an explicit method of modified Dufort-Frankel scheme. Among various missions, close air support mission was considered with 20% hot day ambient condition in subsonic region. The aircraft was assumed to be in turbulent flow. The fuel system model with additional fuel supplies and return concept was considered. As a result of this analysis, the fuel tank temperatures have increased with the increase of the additional fuel supplies. In contrast to tank temperatures, the fuel temperature at the engine inlet has decreased with the increase of additional fuel supplies except in some in-flight phases having high engine fuel flow. From this analysis, the fuel system with the additional fuel supplies and return concept has been shown to be an effective method to decrease the engine inlet fuel temperature. Also, it has been shown that fuel flow rate through fuel/oil heat exchanger is a key factor influencing fuel temperature.

A Study of On-line Cleaning Method for Increasing Efficiency in a Combustor (연소로 효율증진을 위한 on-line 세정 방법에 관한 연구)

  • Jang, Hyun-Tae;Han, Seung-Dong;Park, Tae-Sung;Cha, Wang-Seong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.11 no.3
    • /
    • pp.1016-1022
    • /
    • 2010
  • An Experimental study of cleaning solution has been performed on a high capacity steam boiler burning heavy fuel oil to on-line cleaning of deposit. The deposit is mixture of soot, slag, ash, metal oxide and clinker. The traditional technology of deposit cleaning was carried hand-crafted. The conventional technology of boiler cleaning method is mechanical removal by the worker while the boiler shut down operation. In this experiment, the deposit of mixture of soot, slag, ash, metal oxide and clinker has been removed by the cleaning agents without shut down of boiler burning. This study found out the optimum cleaning solution composition. The best results have been obtained when the mixture of ammonium nitrate and $MgNO_3$ were used in cleaning solution. The various transition metal effect was investigated for optimum mixing condition. In this research, the metal compound additive of the clean solution compoition was obtained. The combustion efficiency was improved by on-line cleaning with derived clean solution compoition. On-line cleaning method prevents the fouling and corrosion in the boiler and heat exchanger.

Evaluation of Ground Thermal Conductivity by Performing In-Situ Thermal Response test (TRT) and CFD Back-Analysis (현장 열응답 시험(TRT)과 CFD 역해석을 통한 지반의 열전도도 평가)

  • Park, Moonseo;Lee, Chulho;Park, Sangwoo;Sohn, Byonghu;Choi, Hangseok
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.12
    • /
    • pp.5-15
    • /
    • 2012
  • In this study, a series of CFD (Computational Fluid Dynamics) numerical analyses were performed in order to evaluate the thermal performance of six full-scale closed-loop vertical ground heat exchangers constructed in a test bed located in Wonju. The circulation HDPE pipe, borehole and surrounding ground formation were modeled using FLUENT, a finite-volume method (FVM) program, for analyzing the heat transfer process of the system. Two user-defined functions (UDFs) accounting for the difference in the temperatures of the circulating inflow and outflow fluid and the variation of the surrounding ground temperature with depth were adopted in the FLUENT model. The relevant thermal properties of materials measured in laboratory were used in the numerical analyses to compare the thermal efficiency of various types of the heat exchangers installed in the test bed. The simulation results provide a verification for the in-situ thermal response test (TRT) data. The CFD numerical back-analysis with the ground thermal conductivity of 4 W/mK yielded better agreement with the in-situ thermal response tests than with the ground thermal conductivity of 3 W/mK.