• Title/Summary/Keyword: Heat exchanger design

Search Result 682, Processing Time 0.029 seconds

The Development of Catalytic Combustor With Heat Exchanger

  • Phil, Yu-Sang;Seok, Seo-Yong;Seop, Song-Kwang
    • 한국에너지공학회:학술대회논문집
    • /
    • 한국에너지공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.21-27
    • /
    • 2002
  • Catalytic combustor with heat exchangers are often employed in process technology where a compact design is required [1]. The use of fin and tube heat exchanger offers the enhanced surface area for heat exchange. The recent progress and performance of the fin-tube heat exchanger, especially airside, has been reviewed extensively by Wang[2].(Omitted)

  • PDF

원통다관식 열교환기의 압력 변화에 따른 설계 응력 연구 (Study upon Design Stress due to Pressure of Shell-and-Tube Type Heat Exchanger)

  • 이용범;한성건;고재명
    • 유공압시스템학회논문집
    • /
    • 제5권2호
    • /
    • pp.8-13
    • /
    • 2008
  • Shell-and-tube type heat exchangers are generally classified with fixed tube-sheet and floating tube-sheet heat exchangers. In this paper, we employed the fixed tube-sheet heat exchangers. We theoretically investigated the safety evaluation of our shell-tube heat exchanger by axial, bending and equivalent stress of fin tubes, tube plates, channels and shell. Design pressure ranges were chosen pressure($0.6{\sim}2\;MPa$) on tube side and 200 %(3 MPa) of Maximum pressure on shell side for safety evaluation of heat exchangers. This research will be useful for fabrication of heat exchangers to prevent against damage hazard of heat exchangers in operation.

  • PDF

소듐냉각고속로 잔열제거계통 강제대류 소듐-공기 열교환기의 구조개념 설계 (Structural design concept of the forced-draft sodium-to-air heat exchanger in the decay heat removal system of PGSFR)

  • 김낙현;이사용;김성균
    • 한국압력기기공학회 논문집
    • /
    • 제12권1호
    • /
    • pp.78-84
    • /
    • 2016
  • The FHX (Forced-draft sodium-to-air Heat Exchanger) employed in the ADHRS (active decay heat removal system) is a shell-and-tube type counter-current flow heat exchanger with M-shape finned-tube arrangement. Liquid sodium flows inside the heat transfer tubes and atmospheric air flows over the finned tubes. The unit is placed in the upper region of the reactor building and has function of dumping the system heat load into the final heat sink, i.e., the atmosphere. Heat is transmitted from the primary cold sodium pool into the ADHRS sodium loop via DHX (decay heat exchanger), and a direct heat exchange occurs between the tube-side sodium and the shell-side air through the FHX tube wall. This paper describes the DHRS and the structural design of the FHX.

판각형 열교환기 성능해석에 관한 연구 (A Study on the Performance Analysis in the Plate and Shell Heat Exchanger)

  • 서무교;박재홍;김영수
    • 동력기계공학회지
    • /
    • 제5권1호
    • /
    • pp.35-43
    • /
    • 2001
  • Heat exchangers are called with important devices which have been widely used in industrial fields. Therefore, the design method for a heat exchanger is an important study in the aspect of energy saving. In this study, performance analyses for two types of plate and shell heat exchangers having a corrugated trapezoid shape of a chevron angle with $45^{\circ}$, were executed and compared with experiments. For this study, the operation liquids were adopted with non-phase changing water. In the analysis, ${\epsilon}-NTU$ method was used for a plate and shell heat exchanger and a program was constructed. Independent variables for a plate and shell heat exchanger are flow rate and inlet temperature. Compared with experimental data, the accuracy of the developed are ${\pm}2.5%\;and\;{\pm}5%$ at the type A and type B in the heat transfer rate, respectively. In the pressure drop, the accuracy of the proposed program for a plate and shell heat exchanger is within ${\pm}3%$ and 5% error bounds for the type A and type B, respectively.

  • PDF

밀폐식 냉각탑용 열교환기의 성능에 관한 연구 (A Study on the Performance of Heat Exchanger for Closed Cooling Tower)

  • 이상식;유성연;김진혁;안영환;박형준;유해성
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.334-339
    • /
    • 2008
  • An closed cooling tower is a device similar to a general cooling tower, but with cooling tower replaced by a heat exchanger. The purpose of this study is to evaluate thermal performance of heat exchanger at various conditions and to provide design datebase. The experimental study regarding heat exchanger for closed cooling tower was conducted. Experimental apparatus consists of constant temperature bath, water pump, spray nozzle, heat exchanger, fan, and date acquisition system. Heat transfer rates at various air velocitys, water flow rates, two different spray modes were measured and heat transfer coefficient were calculated to compare the thermal performances. This study provides that the heat transfer coefficient increases with increasing spray water flow rate and with increasing air velocity. The wet mode was more effective than dry mode for closed cooling tower to this study.

  • PDF

자동차 공조용 증발기의 고성능화에 관한 연구 (Study on Development of High Performance Evaporator for Automotive Air Conditioner)

  • 강정길;김기효;박태영;김종수
    • 설비공학논문집
    • /
    • 제7권1호
    • /
    • pp.73-80
    • /
    • 1995
  • The object of the present study is to develop a high performance evaporator for automotive air conditioner. The experiment has been conducted on evaporative heat transfer coefficient inside a plate type heat exchanger with a sharp 180-degree turn flow. The test plates have different formed surface, cross-ribbed channel and elliptical-ribbed channel. Also experimental study has been performed to determine optimal design in elliptical-ribbed plate heat exchanger with different turn clearance. In addition to the above experiments, refrigerant behavior and surface temperature distribution in the plate heat exchanger were observed using color thermoviewer(infrared thermometer). In this experiment, working fluid was used R-12 and test conditions were as follows : (1) saturation pressure of $2.116kg/cm^2$, (2) mass fluxes of 40 to $70kg/m^2s$, (3) heat fluxes of 4,500 to $7,300W/m^2$, (4) inlet quality of 0.1 to 0.7. The results indicated that the evaporative heat transfer coefficient of an elliptical-ribbed plate heat exchanger was higher than that of cross-ribbed plate heat exchanger. Also optimal turn clearance in an elliptical-ribbed plate heat exchanger was determined.

  • PDF

증기압축식 냉동장치에서 다증관 열교환기의 성능특성에 관한 실험적 연구 (An Experimental Study of the Performance Characteristics on Multiple-tube Heat Exchanger in the Vapor Compression Refrigeration System)

  • 김재돌
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제33권1호
    • /
    • pp.37-43
    • /
    • 2009
  • This paper is performed to develop a tripple-tube exchanger which can improve the system efficiency. Three different tube diameters are compacted by one body(tripple-tube) to recover waste heat from heat exchanging among the fluids. With this, the tripple-tube shows higher cooling capacity than the double-tube after comparing between those two systems. The results of this paper are basic data to design the optimum tripple-tube heat exchanger.

열교환기 형식에 따른 열교환기의 에너지 및 엔트랜시 성능 특성 해석 (Energy and Entransy Characteristic Analysis of Heat Exchangers Depending on Heat Exchanger Type)

  • 김경훈;정영관;한철호
    • 한국수소및신에너지학회논문집
    • /
    • 제31권1호
    • /
    • pp.112-121
    • /
    • 2020
  • In this work energy and entransy characteristics of heat exchangers are analyzed for 12 different flow arrangements of heat exchangers. The dimensionless parameters are number of entransy dissipation (Ng), number of entransy dissipation-based thermal resistance (Nr), and entransy dissipation-based effectiveness of heat-exchanger (εg). The dimensionless parameters are expressed analytically in terms of the effectiveness of heat exchanger (ε), heat capacity ratio (c), and number of transfer unit (N) for optimal performance of heat exchangers. Results showed that the dimensionless parameters based on the entransy dissipation can be useful concepts for optimal design of heat exchangers.

R744를 2차 냉매로 사용하는 내부열교환기 부착 R404A 냉동시스템의 성능 분석 (Performance Analysis of R404A Refrigeration System with Internal Heat Exchanger Using R744 as a Secondary Refrigerant)

  • 오후규;손창효;이문빈;전민주
    • 설비공학논문집
    • /
    • 제25권10호
    • /
    • pp.548-554
    • /
    • 2013
  • A thermodynamic analysis of the R404A refrigeration system with an internal heat exchanger using R744 as a secondary refrigerant is presented in this paper to optimize the design for operating parameters of the system. The main results are summarized as follows: The COP increases with increasing subcooling and superheating degree of R404A, internal heat exchanger and compression efficiency of the R404A cycle and evaporating temperature of the R744 cycle and decreasing temperature difference of the cascade heat exchanger and condensing temperature of the R404A cycle. The mass flow ratio decreases with increasing evaporating temperature of the R744 cycle and internal heat exchanger efficiency of the R404A cycle and decreasing subcooling and superheating degree of the R744 cycle, temperature difference of the cascade heat exchanger and condensing temperature of the R404A cycle.

은나노 공조시스템의 열교환기 설계를 위한 노즐의 분무특성 실험 (An Experimental Study on Nozzle Spray Characteristics for the Design of Heat Exchangers of a Nano-Silver HVAC System)

  • 허주영;강병하
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.534-537
    • /
    • 2008
  • Growing attention has been given to sterilizing and antibacterial effects of nano-silver, recently. Nano-silver solution can be applied to the heat exchanger in an air conditioner to prevent bad smell or bacteria. The present study is directed at the nozzle spray characteristics over a heat exchanger. This problem is of particular interest in the design of a nano-silver HVAC system. The effects of nozzle position and flow rate on the spray area over a horizontal surface have been investigated for various nozzles. The results obtained indicate that spray area is increased as the height of spray position is increased or mass flow rate is increased. The wetted area over a practical heat exchanger is also studied at a given nozzle height. It is found that the wetted area is gradually increased with an increase in the flow rate. However, the effect of flow rate on the wetted area is a little affected by flow rate in the range of too much flow rate. It is also found that the wetted area is decreased as the inclination angle of a heat exchanger is increased.

  • PDF