• 제목/요약/키워드: Heat exchange area

검색결과 100건 처리시간 0.022초

폐열회수 환기장치의 열교환 효율 개선을 위한 전산수치해석 (Numerical Analysis of Wasted Heat Recovery Ventilator for Improving the Heat Exchange Efficiency)

  • 김현일;김재성;박철우;박경서
    • 한국CDE학회논문집
    • /
    • 제17권1호
    • /
    • pp.54-61
    • /
    • 2012
  • In this paper, we performed numerical analysis to improve the heat exchange efficiency of wasted heat recovery ventilator which has a delivery and a exhaustion fan. One of the most important design factors that affect the efficiency of heat exchange is uniform counter-flow between inbound and outbound air flows. We had simulated several types of porous plates which were installed at air intake area. With plate having 45 degrees of installation angle and 15 mm diameter holes which are uniformly arranged, we can generate a uniform air flows at the area of porous media where inbound and outbound air flows are cross over. In addition, we installed a duct to reduce vortex flows at the outlet and to discharge exhaust airs rapidly. By using the proposed numerical assessment, we expect the improvement of the heat exchange efficiency of ventilator.

거주공간에서의 복선열교환에 관한 연구 -착의시의 착의부와 노출부의 열수수 (A study on the radiant heat exchange in living space)

  • 윤정숙
    • 대한가정학회지
    • /
    • 제24권2호
    • /
    • pp.75-82
    • /
    • 1986
  • This study was measured experimentally the Configuration factor of the adult female with the purpose of explaning quantitatively the human body's radiant heat exchange in a small scale of a house. And it is a investigatio about human clothed body's heat resistance which have great influence on radiant heat exchange. The result of this study was diagrammatized the [Shape×Area Factor] for the sake of making it easy to calculate the quantity of the actual human body's radiant heat exchange, and designed a diagram to make it easy to find the value of the human clothed body's heat resistance and clothing surface temperature. Thus, this research can be used as a basic resource for not only calculating wuantitatively radiant heat exchange of human clothed body and unclothed body in the radiant heating system of low temperature but also designing the thermal environment in a room.

  • PDF

저온측과 고온측 냉매간 열교환이 열펌프의 성능특성에 미치는 영향 (Effect of the Heat Exchange between Low and High Temperature Refrigerant on the Heat Pump Performance)

  • 이건중;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제24권4호
    • /
    • pp.343-350
    • /
    • 1999
  • The ambient air is commonly used as low-temperature heat source for heat pump operation. However, the coefficient of performance(COP) of the air to water heat pump is decreased with the ambient air temperature drop. In this study to solve this problem, the AVACTHE(Automatic Variable Area Capillary Type Heat Exchanger) with 3 levels of heat exchange area(0, 1,495.4, 1,794.5$\textrm{cm}^2$)was installed in the refrigerant circuit of the heat pump. The AVACTHE effect on the performance of heat pump was tested with the ambient air temperature variation. The COP improvement of the heat pump could be achieved by the AVACTHE installation when below -5$^{\circ}C$ of the ambient air temperature.

  • PDF

저온측과 고온측 냉매간 열교환이 열펌프의 성능특성에 미치는 영향 (Effect of the Heat Exchange between Low and High Temperature Refrigerant on the Heat Pump Performance)

  • 이건중;송현갑
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 1999년도 동계 학술대회 논문집
    • /
    • pp.211-218
    • /
    • 1999
  • The ambient air is commonly used as low-temperature heat sources for heat pump operation. However, the coefficient of performance (COP) of the air -water heat pump is decreased with the ambient air temperature drop. In this study to solve this problem , the AVACTHE(Automatic Variable Area Capillary Type Heat Exchanger) with 3 levels of heat exchange area(0, 1495.4, 1794.5$\textrm{cm}^2$) was installed in the refrigerant circuit of the heat pump. The AVACTHE effect on the performance of heat pump was tested with the ambient air temperature variation. The high level COP of the heat pump could be achieved by the AVACTHE installation when below -5$^{\circ}C$ of the ambient air temperature.

  • PDF

개량형 열회수 시스템의 열교환 성능 (Heat Exchange Performance of Improved Heat Recovery System)

  • 서원명;윤용철;권진근
    • 생물환경조절학회지
    • /
    • 제12권3호
    • /
    • pp.107-113
    • /
    • 2003
  • 본 연구에서는 온실의 온풍식 난방시스템 연통에 장착할 수 있는 폐열 회수기의 성능 개선을 목적으로 기 설계된 세 가지 열교환 장치와 기존의 장치에서 열교환 면적과 파이프의 두께 및 공기흐름 방향을 개량한 새 열교환 장치에 대해 열회수 성능을 실험적으로 비교 분석하였다. 그 결과 기존의 열 교환장치인 A형, B형 및 C형의 열회수 성능은 동일 송풍전입에서 각각 42.2%, 40.6% 및 54.4% 정도였으나 , 새로 개량된 D형은 69.2%로써 가장 현저히 높게 나타났다. 그러나 열회수용 공기의 흐름방향 변화에 따른 열회수 성능 개선효과 (A형 대비 B형)는 없는 것으로 나타나 적정 송풍기 용량이라면 직선형이 공기의 흐름방향 180${\circ}C$ 굴절시키는 헤어핀형보다 효과적인 것으로 판단된다. 결국 열회수 성능은 열회수 시스템의 열교환 면적과 열교환 파이프의 두께 및 풍속에 크게 좌우되는 것으로 나타났다. 따라서, 열교환 파이프의 내구성 등 을 고려하여 기능한 한 범위 내에서 열 교환면적을 증대시키거나 열교환 파이프의 두께를 앓게 하고 풍속을 증대시키는 것이 열회수 성능 개선효과와 직결됨을 알 수 있었다. 그리고 송풍기 용량이 필요이상으로 큰 경우, 소비전력이 많게 되는 등의 문제가 있기 때문에 적정용량 및 제품의 안정성을 고려하여 선택해야 할 것으로 판단되었다.

적층형 EGR Cooler의 Pitch 길이 변화가 열교환 특성에 미치는 영향 (Effects of Pitch Length of Stack-type EGR Cooler on Heat Exchange Characteristics in a Diesel Engine)

  • 황세준;김민철;장상훈;김형만
    • 한국자동차공학회논문집
    • /
    • 제18권2호
    • /
    • pp.135-140
    • /
    • 2010
  • An important goal in diesel engine research is the development of a means to reduce the emissions of nitrogen oxides (NOX). The use of a cooled exhaust gas recirculation (EGR) system is one of the most effective techniques currently available for reducing nitrogen oxides. Since Particular Matter (PM) fouling reduces the efficiency of an EGR cooler, a trade-off exists between the amount of NOX and PM emissions, especially at high engine loads. In the present study, engine dynamometer experiments have been performed to investigate the heat exchange characteristics of the stack-type EGR coolers with wave fin pitches of 3.6 and 4.6 mm. The results show that the heat exchange effectiveness is decreased as surface area decrease with pitch of 4.6 mm due to PM fouling. As surface area increase at pitch of 3.6 mm, super-cooling happens in the recirculated exhaust gas.

컴퓨터 시뮬레이션을 이용한 고압다이캐스팅 금형의 이형제 분사공정에 따른 금형온도분포 및 금형수명 예측 (A prediction of mold temperature distribution and lifetime with different spray process of mold release agent in high pressure diecasting mold using computer simulation)

  • 김동현;윤상일;장대정
    • Design & Manufacturing
    • /
    • 제13권2호
    • /
    • pp.49-53
    • /
    • 2019
  • The temperature distribution and lifetime of molds were predicted by computer simulation analysis with various spraying and blowing process of high pressure die casting. After varying the spraying angle and time, the mold temperature, heat exchange and mold life were predicted. As the spraying angle increases, the maximum temperature of the mold decreases, which is because the spraying area increases and the heat exchange with the mold increases. Heat exchange occurs more actively in the blowing process than in the spraying process. This is because the cooling is not performed due to the steam generation. When the spraying angle is 50 degree, the minimum life of the mold is analyzed 200 times. After adjusting the blowing time from 5s to 3s, the minimum lifetime of the mold has been increased almost twice.

Energy Lining Segment 적용성 평가를 위한 기초연구 (Basic Study for Evaluation on Application of Energy Lining Segment)

  • 한상현;박시삼
    • 한국지반신소재학회논문집
    • /
    • 제12권4호
    • /
    • pp.143-147
    • /
    • 2013
  • 지열 에너지는 지구에 저장된 활용하기 쉬운 재생에너지 이며, 열교환 배관 시스템을 통해 수집될 수 있다. 본 연구에서는 터널 주변 라이닝에 지열 에너지를 포집할 수 있는 열교환 파이프 루프를 간편하게 설치할 수 있는 시스템을 개발하였다. 터널 세그먼트에 결합된 열 교환 파이프 루프 시스템은 수송 유체 순환을 통해, 지중 주변의 열을 인근 구조물 또는 지역의 냉난방 열원으로 사용할 수 있다. 터널 세그먼트에 통합 연결된 열 교환 파이프 루프 시스템을 에너지 라이닝 세그먼트(Energy Lining Segment)이라고 명하도록 하겠다. 유럽에서는 터널 라이닝에 열 교환 파이프 루프 시스템을 통합한 수차례의 사례가 있다. 본 연구에서는 에너지 라이닝 세그먼트에 대한 적용성 평가를 위해, 독일 사례와 유럽 도시에 적용된 사례를 조사해 보았다. 또한, 에너지 라이닝 세그먼트의 열 전도특성을 파악하기 위해, 전산유체해석(CFD)을 수행해 보았다.

마이크로휜 관내의 단상유동 열전달계수 (Heat transfer coefficients for single-Phase flow in a micro-fin tube)

  • 권정태;김무환
    • 설비공학논문집
    • /
    • 제10권4호
    • /
    • pp.423-430
    • /
    • 1998
  • Single phase heat transfer coefficients were measured for turbulent water flow in a micro-fin tube by using Wilson plot technique. An experiment for counterflow heat exchange between the micro-fin tube and its outer annulus passage was performed. The annulus side heat transfer resistance was varied and the overall heat transfer coefficients were measured. The single-phase heat transfer coefficients in a micro-fin tube were obtained by Wilson plot technique. Nusselt numbers based on the real heat transfer area and the nominal area were about 35% and 50% larger than those for smooth tube respectively Also, single-phase heat transfer correlations based on real heat transfer area and nominal area have been proposed for a micro-fin tube.

  • PDF

직접순환식 수직밀폐형 지열원 열펌프의 연간 운전성능 평가 (Evaluation of the Annual Performance of the Direct Expansion Vertical Closed-Loop Ground Source Heat Pump)

  • 김민성;우정선;백영진;장재철;김지영;라호상
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2012년도 춘계학술발표대회 논문집
    • /
    • pp.534-542
    • /
    • 2012
  • Vertical closed-loop ground source heat pump systems(GSHP) have been installed widely in Korea since it can extract moderate temperature level of geothermal heat in a small area. As a ground heat exchanger, a vertical closed-loop type with brine circulation is mostly preferred since it is simple and less harmful to ground environment. However, it requires a secondary heat exchange loop between the refrigerant in a heat pump and the brine. By adding a geothermal heat exchanger in the secondary heat exchange loop, circulation pumps should be attached and the temperature difference between refrigerant and ground is increased, which are important parts of performance degradation. In this paper, annual and seasonal performances of direct expansion(DX) geothermal heat pump were estimated mathematically as an alternative of classical indirect geothermal heat pump based on the annual performance evaluation. As a result, DX geothermal heat pump showed 43% higher annual performance than the classical U-tube geothermal heat pump.

  • PDF