• Title/Summary/Keyword: Heat energy

Search Result 7,998, Processing Time 0.034 seconds

A Numerical Analysis of the Reverse Heat Loss Method for a Refrigerator (냉장고 역열손실 방법의 수치해석적 분석에 관한 연구)

  • Ha, Ji-Soo;Shim, Jae-Sung
    • Journal of Energy Engineering
    • /
    • v.20 no.4
    • /
    • pp.303-308
    • /
    • 2011
  • The present study has been carried out to predict the heat transfer characteristics of reverse heat loss method for a residential refrigerator by using numerical analysis and corresponding experiment. From the measured values of temperature and heat input, one can conclude that, the temperature inside the refrigerator has a nearly linear relationship with heat input. The effect of gasket heat loss was examined with the change of thermal conductivity of gasket region. The appropriate thermal conductivity of gasket region was acquired from the comparison of heat losses with the experimental result and numerical analysis. The result of calculated heat losses had accuracy within 1.8% error with the experimental result. With the selected thermal conductivity of gasket region, the effectiveness of reverse heat loss method was examined with the change of thermal conductivity of vacuum insulation panel.

An Analysis on Effects of Passive Heating of Low Energy House Using Heat in Greenhouse (온실의 열을 이용한 저에너지하우스의 패시브 난방 효과 분석)

  • Yoo, Dong-Wan;Lee, Tae-Goo
    • KIEAE Journal
    • /
    • v.16 no.5
    • /
    • pp.103-109
    • /
    • 2016
  • Purpose: In Korea, to reduce greenhouse gas emissions, energy performance standard of buildings is being reinforced with goals of Passive House until 2017 and Zero Energy House until 2025 in order to reduce emissions from buildings which constitute a quarter of greenhouse gas emissions. In order to achieve the target of Zero Energy House, it is certainly necessary to develop renewable energy that can replace cooling and heating energy occupying a significant amount of building energy consumption after increasing the energy performance firstly. Method: In this study, effects of heat in greenhouse heated by solar heating on indoor heating were analyzed by constructing a greenhouse in front of the Low Energy Building. Result: As a result, indoor temperature was increased by peak average $27.8^{\circ}C$, peak average $6.8^{\circ}C$ was increased from when heat in greenhouse has not been used for heating and indoor surface temperature was increased by average $5.1^{\circ}C$. It shows it can be possible to use heat in greenhouse for heating, if the heating effects can be same as this experimental result because Energy Saving-Type buildings such as Low Energy House or Passive House keep from 18 to $20^{\circ}C$ in winter. Therefore, even if energy supply is cut off by disasters and other reasons, cooling and heating can be possible for some time.

Thermal Performance Analysis of Hybrid heat Supply System for Zero Carbon Green Home (제로카본 그린홈 구현을 위한 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.6
    • /
    • pp.53-59
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000kcal/hr, a $0.15m^3$ hot water storage tank for space heating, a evacuated tubular solar collector $3.74m^2$ of aperture area at the $20^{\circ}$ install angle, a $0.3m^3$ hot water storage tank. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

Energy Performance Analysis of Electric Heater and Heat Pump Food Dryers (전기히터식 및 히트펌프식 식품 건조기의 에너지 성능 비교)

  • Yu, Young Woo;Kim, Young Il;Park, Seungtae
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.4
    • /
    • pp.1-6
    • /
    • 2015
  • In this study, energy performance of two types of food dryers which are electric heater and heat pump is studied experimentally. With drying chamber temperatures controlled at 45, 50 and $55^{\circ}C$, sliced radish is dried from an initial mass of 90 to final 7 kg. Moisture content, drying time, total power consumption, MER (moisture extraction rate, kg/h) and SMER (specific moisture extraction rate, kg/kWh) are measured and analyzed. As the drying chamber temperature is increased, drying time is shortened but energy efficiency is reduced for both types. For an electric heater dryer, the effect of chamber temperature on drying time is significant but less significant on energy efficiency. For a heat pump dryer, the dependence of chamber temperature on drying time is weak but strong on energy efficiency. Temperature levels have little effect on electric heater dryer performance but strong effect on heat pump dryer which operates on a vapor compression refrigeration cycle. The energy performance of the heat pump dryer is superior with an average SMER of 2.175 kg/kWh which is 2.22 times greater than that of the electric heater dryer with SMER of 1.224 kg/kWh.

A Study on the Measurement of Thermal conductivity of Vertical Borehole heat Exchanger (수직형 지중열교환기 열전도도 측정기술에 관한 연구)

  • Kim, Ji-Young;Lee, Euy-Joon;Chang, Ki-Chang;Kang, Eun-Chul
    • Proceedings of the SAREK Conference
    • /
    • 2008.11a
    • /
    • pp.39-44
    • /
    • 2008
  • The heat exchange between the Borehole Heat Exchanger(BHE) and the surrounding ground depends directly on ground thermal conductivity k at the certain site. The k is thus a key parameter in designing BHE and coupled geothermal heat pump systems. Currently, although a thermal hydraulic response test(TRT) is mostly used in practice, the thermal hydraulic TRT needs additional power and is generally time-consuming. A new, simple wireless P/T probe for a hi-speed k determination was introduced in this paper. This technique using a wireless P/T probe is less time-consuming and requires no external source of energy for measurement and predicts local thermal properties by measuring soil temperatures along the depth. Measured temperature data along the depth was analyzed. In order to verify the new technique for the determination of ground thermal conductivity, ground thermal conductivity k that calculated from the measured temperature data using a wireless P/T probe was compared with one obtained from conventional hydraulic TRT. When comparing the average k of two methods, the relative error was approximately 10%. As a result, the electronic TRT can replace the conventional hydraulic TRT method after carrying out the additional research on a lot of sites.

  • PDF

Experimental Study on the Working Fluid Selection of Medium Temperature Heat Pipe (중온 히트파이프에서 작동유체 선정에 관한 실험적 연구)

  • Lee, Young-Soo;Park, Ki-Ho;Baik, Young-Jin
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.3 no.2
    • /
    • pp.1-7
    • /
    • 2007
  • This paper is concerned with the selection of proper working fluids for medium temperature range heat pipe. The heat pipe which is made of SUS 316L has a total length of 700 mm as well as an outside diameter of 27.2 mm and a thickness of 2.1 mm respectively. Working fluids used in this study were Naphthalene, Biphenyl and Dowtherm A. Their charge amounts were about 40% of the inside volume of evaporator section. Experimental results shows that the Dowtherm A is good for $200^{\circ}C{\sim}300^{\circ}C$temperature range, while the Naphthalene is proper for $300^{\circ}C{\sim}430^{\circ}C$. In the case of the Naphthalene heat pipe, the heat transfer rate reaches 1500 W along with a vapor temperature of $430^{\circ}C$.

  • PDF

Characteristic Analysis of the Cooling System Using Ice Slurry Type Heat Storage System (아이스슬러리형 빙축열 시스템을 이용한 냉각 시스템의 성능에 관한 실험적 연구)

  • Lee, Dong-Won;Kim, Jeong-Bae
    • Journal of Energy Engineering
    • /
    • v.20 no.1
    • /
    • pp.30-35
    • /
    • 2011
  • To clarify the hydraulic and thermal characteristics of ice slurry which made from 6.5% ethylene glycol-water solution flow in the double tube and plate type heat exchanger, experimental studies were performed. The mass flux and ice fraction of ice slurry were varied from 800 to 3500 kg/$m^2s$(or 7 to 17 kg/min) and from 0 to 25%, respectively. Through the experiment, it was found that the measured pressure drop and heat transfer rate increase with the mass flux and ice fraction; however the effect of ice fraction appears not to be significant at high mass flux region. At the region of low mass flux, a sharp increase in the pressure drop and heat transfer rate were observed depends on mass flux.

Purification of Hydrogenase from Thiocapsa roseopersicina : Effect of Ammonium Sulfate Precipitation and Heat-Treatment (홍색 유황세균 Thiocapsa roseopersicina가 생산하는 수소생산 효소의 정제 : Ammonium sulfate 침전 및 열처리의 효과)

  • Choi, Eun-Hye;Oh, You-Kwan;Kim, Mi-Sun
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.4
    • /
    • pp.371-378
    • /
    • 2006
  • Effect of $(NH_4)_2SO_4$ precipitation and heat-treatment on hydrogenase which was extracted from the cytoplasmic fraction of the phototrophic purple sulfur bacterium Thiocapsa roseopersicina NCIB 8347 was studied. Crude enzyme extract was prepared by centrifugation($28,000{\times}g$, $400,000{\times}g$) after sonication of cells grown under photosynthetic condition for 96 hrs. Various conditions of $(NH_4)_2SO_4$ precipitation and heat-treatment were examined and the effect of protein concentration was analyzed by SDS-electrophoresis between the treatments. Optimum conditions for $(NH_4)_2SO_4$ precipitation and heat-treatment for evolution hydrogenase activity were 40-60% saturation and $60^{\circ}C$ for 20 min, respectively, which exhibited the specific hydrogenase activity of 0.78 U/mg-protein. Specific hydrogenase activity was decreased to 31.6% when the heat-treatment at $60^{\circ}C$ increased from 20 min to 5 hrs.

AN EXPERIMENTAL STUDY ON POST-CHF HEAT TRANSFER FOR LOW FLOW OF WATER IN A $3\times3$ ROD BUNDLE

  • MOON SANG-KI;CHUN SE-YOUNG;CHO SEOK;KIM SE-YUN;BAEK WON-PIL
    • Nuclear Engineering and Technology
    • /
    • v.37 no.5
    • /
    • pp.457-468
    • /
    • 2005
  • An experimental study on post-CHF heat transfer has been performed with a $3\times3$ rod bundle using a vertical steam-water two-phase flow at low flow conditions. The effects of various parameters on the post-CHF heat transfer are investigated and the reasons for the parametric effects are discussed. As the heat transfer regime changes from CHF to post-CHF, the radial wall temperature distribution is changed depending on the pressure and the mass flux conditions. The superheat of the fluid increases considerably with an increase of the wall temperature (or heat flux) and with a decrease of the mass flux. This implies, indirectly, a strong thermal non-equilibrium at high wall temperature and low mass flux conditions. In order to improve the prediction accuracy of the existing post-CHF correlations, it is necessary to perform more experiments, particularly direct measurement of the vapor superheat, and to modify the correlation by considering a strong thermal non-equilibrium at low flow and low pressure conditions.

A Study on Cycle and Flow Analysis for Improvement of Energy Efficiency of a Heat Pump Dryer with Hot Bypass Gas and Air Dampers During Warm-up Stage (고온 우회가스 및 에어댐퍼 사용을 통한 히트펌프 건조기 승온단계 에너지 효율 향상을 위한 사이클 및 유동해석 연구)

  • Park, Sang-Jun;Hwang, Il-Sun;Lee, Young-Lim
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.13 no.9
    • /
    • pp.3827-3834
    • /
    • 2012
  • Recently, instead of hot air type dryers that require a lot of heat, energy-efficient heat pump dryers have been used in various fields such as paper, textile, wood, food, etc. In this paper, the characteristics of heat pump cycle were theoretically evaluated with hot-gas bypass system to further improve the energy efficiency by minimizing the use of electric heaters in early warm-up stage of the dryers for frozen agricultural products. In addition, damper system that leads outside air to flow into the dryer were optimized to obtain extra heat for higher energy efficiency.