Evaluation of Integrity of the Tubes in the Horizontal Fixed Tubesheet Heat Exchanger by Using Equivalent Modeling (고정 튜브시트를 갖는 수평형 열교환기의 등가 모델링을 이용한 튜브 건전성 평가)

  • Jeon, Yun-Cheol;Kim, Tae-Wan;Jeong, Dong-Gwan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.1
    • /
    • pp.179-187
    • /
    • 2002
  • Finite element analysis was performed to evaluate the integrity of the tubes in the fixed tubesheet of horizontal type heat exchanger under operating condition. For the finite element analysis of the heat exchanger, tubes and tubesheets were equivalently modeled with concentroidal hexagonal columns and solid plates having equivalent properties for the convenience of finite element modeling, respectively. Load combination of tube pressure and thermal expansion most likely to precipitate possible failure of the tubes was selected and applied to the finite element analysis. The compressive stresses of the tubes were calculated based on displacements of each tube, which were obtained from anile element analysis. Finally, the maximum tube stress was compared with the design criterion of ASME Boiler and Pressure Vessel Code Section VIII.

A Study on the Temperature Distribution and Computational Effort of Rectangular Cross-Section by the Finite Dynamic Element Method (유한 요소법에 의한 구형단면의 온도분포와 Computational Effort에 관한 연구)

  • Yong, Ho-Taek
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.13 no.2
    • /
    • pp.10-15
    • /
    • 1984
  • The aims of this study are to obtain a suitable method and a proper mesh for investigation of the temperature distribution and heat transfer. The relative errors of temperature distribution and heat transfer for each mesh are acquired in accordance with linear finite element (FEM 3), square finite element (FEM 6), cubic finite element (FEM 10), and finite difference method (FDM). It has been found that FEM 10 is the most accurate measure to obtain the temperature distribution and heat transfer. However, no significant results have been obtained successfully, because when higher order finite element methods are used the more computational efforts are necessary due to the distribution of elements. The results of this study are as follows ; 1 . In case of a=b=L, meshes for less than $1\%$ relative errors (temperature distribution) acquired in various methods to exact solution are $2\times2,\;4\times4,\;8\times8\;and\;8\tiems8$ for each FEM 10, FEM 6, FEM 3 and FDM and a=L, b=1/2L are $10\times5$ for each FEM 3 and FDM. And the tendency of results acquired of heat transfer is similar to those above. 2 . In computational efforts (a=b=L), FEM 6 has taken 21 times. and FEM 10 154times FEM 3 and FDM and FEM 3 is the sane as FDM.

  • PDF

New algorithm for simulating heat transfer in a complex CPFS (Cable Penetration Fire Stop)

  • Yun, Jong-Pil;Kwon, Seong-Pil;Cho, Jae-Kyu;Yoon, En-Sup
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1798-1803
    • /
    • 2003
  • In this work the dynamic heat transfer occurring in a cable penetration fire stop system built in the firewall of nuclear power plants is three-dimensionally investigated to develop a test-simulator that can be used to verify effectiveness of the sealants. The dynamic heat transfer can be described by a partial differential equation (PDE) and its initial and boundary conditions. For the shake of simplicity PDE is divided into two parts; one corresponding to the heat transfer in the axial direction and the other corresponding to the heat transfer on the vertical layers. Two numerical methods, SOR (Sequential Over-Relaxation) and FEM (Finite Element Method), are implemented to solve these equations respectively. The axial line is discretized, and SOR is applied. Similarly, all the layers are separated into finite elements, where the time and spatial functions are assumed to be of orthogonal collocation state at each element. The heat fluxes on the layers are calculated by FEM. It is shown that the penetration cable influences the temperature distribution of the fire stop system very significantly. The simulation results are shown in the three-dimensional graphics for the understanding of the transient temperature distribution in the fire stop system.

  • PDF

A Study on The Performance of a Heat Recovery Ventilator According to the Properties of Spacers (스페이서의 재질변화에 따른 전열교환기 성능변화에 관한 연구)

  • Lim, Tae-Kun;Jeon, Byung-Heon;Kim, Jong-Won;Jung, Sung-Hak;Lee, Seung-Kap;Ahn, Young-Chull
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.24 no.3
    • /
    • pp.224-229
    • /
    • 2012
  • The importance of ventilation system is being emphasized by interest of indoor air quality. Especially, heat recovery ventilation system has attracted attention as most effective ventilation plan. Because it can reduce hazardous construction materials, indoor air pollutions, and also can reduce air conditioning energy cost. In heat recovery ventilator, the element core is the most important part. The element core is composed of liner and spacer. And liner and spacer are stacked alternately. On the Liner, heat and humidity transfer are made between supply and exhaust air. And spacer plays a role as a tunnel of exhaust and supply. In this study, we investigated and analyzed the efficiency of a heat recovery ventilator, when the spacer's properties are changed. As a result, difference spacer's properties affect an efficiency of heat recovery ventilator.

A study on an experimental basis a special character of insulating oil the use of a transformers (변압기용 절연유의 특성에 관한 실험적 연구)

  • Kim, Sung-Dae;Park, Il-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.11
    • /
    • pp.5188-5193
    • /
    • 2011
  • This research is for temperature control of insulating oil inside the transformer. After I designed and manufactured various systems using Peltier element, which was thermal element, and Heat pipe, which was a cooling system, without electric power. The optimum system could be made by applying them to the temperature control for the insulating oil. I could verify that the combination type of Heat pipe 100 W+ Peltier 100W has a more outstanding capacity than pure Heat pipe 300 W within 60 degrees Celsius through experiments. Through this, I verify that the method of a proper design is prominent, and make an attempt at contribution to power saving effect and more effective control of Distributing board by using this combination type.

Temperature Control using Peltier Element by PWM Method

  • Pang, Du-Yeol;Jeon, Won-Suk;Choi, Kwang-Hoon;Kwon, Tae-Kyu;Kim, Nam-Gyun;Lee, Seong-Cheol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.1400-1404
    • /
    • 2005
  • This paper presents the temperature control of aluminum plate by using Peltier element. Peltier effect is heat pumping phenomena by electric energy as one of the thermoelectric effect. So if current is charged to Peltier element, it absorbs heat from low temperature side and emits heat to high temperature side. In this experiment, Peltier element is used to control the temperature of small aluminum plate with current control and operating cooling fan only while cooling duration. Operating cooling fan only while cooling duration is proper to get more rapid heating and cooling duration. As a result of experiment, it takes about 100sec period to repeating temperature between $35^{\circ}C$ and $70^{\circ}C$ and about 80sec from $40^{\circ}C$ to $70^{\circ}C$ in ambient air temperature $25^{\circ}C$ and while operating cooling fan only in cooling duration. Future aim is to apply this temperature control method in actuating SMHA(special metal hydride actuator) which is applicable in Siver project acting in low frequency range by using Peltier element for heating and cooling.

  • PDF

An Investigation on the Thermal Characteristics of Heat-Responsive Element of Sprinkler Head (스프링클러헤드 감열부의 열적 특성에 관한 연구)

  • You, Woo-Jun;Moon, Hyo-Jun;Youm, Moon-Cheon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.79-84
    • /
    • 2012
  • In this study thermal characteristics of heat-responsive element considering conduction, convection and rate of change of element using Response Time Index (RTI) applied to sensitivity test of sprinkler head at home and aborad are theoretically investigated. Analytic solution of temperature distributions with radial direction and time is obtained form energy transport equations, non-homogeneous 2th order partial differential equation, applying to constant wall temperature and symmetric condition in order to analyze thermal characteristics of heat-responsive element for circular cylindrical geometry. Base on the results, the analytic method of this study is fundamental data to practical use for sensitivity test of sprinkler head and design of heat-responsive element.

Involvement of Putative Heat Shock Element in Transcriptional Regulation of $p21^{WAF1/ClP1/SDl1}$ by Heat Shock

  • Woo, Sang-Hyeok;Oh, Su-Young;Han, Song-Iy;Choi, Yung-Hyun;Kang, Kwang-Il;Yoo, Mi-Ae;Kim, Han-Do;Kang, Ho-Sung
    • Animal cells and systems
    • /
    • v.4 no.2
    • /
    • pp.181-186
    • /
    • 2000
  • The expression of $p21^{WAF1/ClP1/SDl1}$, one of the cyclin-dependent kinase inhibitors, is regulated by a variety of transcription factors including p53 and STAT. Heat shock induces the expression of p21 in a temperature- and time-dependent manner. Although the p21 induction by heat shock has been reported to be controlled by p53, a p53-independent mechanism Is also involved. To understand the p53-independent regulation of heat shock-induced p21 expression, we searched the promoter region of p21 gene and found one or two heat shock element (HSE)-like sequences in human, rat, and mouse. Electromobility shift assay (EMSA) showed that heat shock factor (HSF) could bind to these HSE-like sequences In response to heat shock, even though to a lesser extent than to HSE. In addition, p21 promoter deletion analysis revealed that heat shock activated a p21 deletion promoter construct containing the HSE-like sequences but lacking p53-binding sites, but not a promoter construct containing neither HSE-like sequences nor the p53-responsive element. Furthermore, the p21 induction by heat shook was significantly inhibited in confluent cells in which heat shock-induced HSF activation was reduced. These results suggest that the transcriptional regulation of p21 by heat shock may be mediated through activation and binding to HSE-like sequences of HSF.

  • PDF

AN ANALYSIS OF MOLDING AND CURING OF SMC BY THE FINITE ELEMENT METHOD

  • Kim, Naksoo-
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 1992.03a
    • /
    • pp.177-200
    • /
    • 1992
  • A thermo-viscoplastic finite element program was developed to analyze the compression molding of SMC process. Deformation of the material was modelled by using the flow-rule. Heat balance during the process was coupled to the deformation. In the cure study, a kinetic model was adopted to describe the cure behavior. The numerical kinetic model was integrated with the thermo-viscoplastic numerical analysis by adding heat generation due to the chemical reaction of the workpiece in the heat transfer analysis. The integrated finite element program can simulate a whole sequential molding process including deformation, heat transfer, and chemical reaction. A practical SMC molding process with T-shaped substructure was simulated. The simulated results showed good agreements with experiments.

  • PDF

Finite Element Analysis of Induction Heating Process for Development of Rapid Mold Heating System (급속 금형가열 시스템 개발을 위한 고주파 유도가열 과정의 유한요소해석)

  • Hwang, J.J.;Kwon, O.K.;Yun, J.H.;Park, K.
    • Transactions of Materials Processing
    • /
    • v.16 no.2 s.92
    • /
    • pp.113-119
    • /
    • 2007
  • Rapid mold heating has been recent issue to enable the injection molding of thin-walled parts or micro/nano structures. Induction heating is an efficient way to heat material by means of an electric current that is caused to flow through the material or its container by electromagnetic induction. It has various applications such as heat treatment, brazing, welding, melting, and mold heating. The present study covers a finite element analysis of the induction heating process which can rapidly raise mold temperature. To simulate the induction heating process, the electromagnetic field analysis and transient heat transfer analysis are required collectively. In this study, a coupled analysis connecting electromagnetic analysis with heat transfer simulation is carried out. The estimated temperature changes are compared with experimental measurements for various heating conditions.