• 제목/요약/키워드: Heat discharge

Search Result 536, Processing Time 0.024 seconds

Influence Analysis on the Number of Ruptured SG u-tubes During mSGTR in CANDU-6 Plants (중수로 증기발생기 다중 전열관 파단사고시 파단 전열관 수에 대한 영향 분석)

  • Seon Oh Yu;Kyung Won Lee
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.18 no.2
    • /
    • pp.37-42
    • /
    • 2022
  • An influence analysis on multiple steam generator tube rupture (mSGTR) followed by an unmitigated station blackout is performed to compare the plant responses according to the number of ruptured u-tubes under the assumption of a total of 10 ruptured u-tubes. In all calculation cases, the transient behaviour of major thermal-hydraulic parameters, such as the discharge flow rate through the ruptured u-tubes, reactor header pressure, and void fraction in the fuel channels is found to be overall similar to that of the base case having a single SG with 10 u-tubes ruptured. Additionally, as the conditions of low-flow coolant with high void fraction in the broken loop continued, causing the degradation of decay heat removal, the peak cladding temperature (PCT) would be expected to exceed the limit criteria for ensuring nuclear fuel integrity. However, despite the same total number of ruptured u-tubes, because of the different connection configuration between the SG and pressurizer, a difference is foud in time between the pressurizer low-level signal and reactor header low-pressure signal, affecting the time to trip the reactor and to reach the PCT limit. The present study is expected to provide the technical basis for the accident management strategy for mSGTR transient conditions of CANDU-6 plants.

Effects of Food Waste Mixed Organic Fertilizer Treatment on Growth and Yield of Capsicum annuum

  • Ho-Jun Gam;Yosep Kang;Eun-Jung Park;Seong-Heon Kim;Sang-Mo Kang;In-Jung Lee
    • Proceedings of the Korean Society of Crop Science Conference
    • /
    • 2022.10a
    • /
    • pp.109-109
    • /
    • 2022
  • The global population is increasing every year, and the amount of food waste is also increasing. Direct landfilling of food waste has been prohibited since 2005, and in accordance with the London Convention in 2013, the discharge of livestock manure, sewage sludge, and food waste into the sea is prohibited. In the case of incineration to treat the discharged food waste, the heat point is lowered due to the moisture in the food waste itself, so fuel must be added. Therefore, this study was conducted to get basic data for setting the limit of application by investigating the growth and yield of crops after treating food waste dry powder mixed fertilizer (MF) on red pepper. In the experiment, continuous cultivation was carried out for two years in 2021 (1st year) and 2022 (2nd year). The treatment groups were set as Not Treatment (NT), Chemical Fertilizer (CF), Mixed Fertilizer (MF), Mixed Fertilizer×2 (MF×2). After harvest, crop growth and yield were investigated. As a result of the 1st years of growth survey, CF, MF, MF×2 show significant difference in shoot length compared to NT. About fresh weight and dry weight, CF show significant difference compared to NT. The 2nd years of growth survey, the shoot and root length, fresh weight did not show significant difference with NT. In case of dry weight, MF is significant increased compared to NT. As a result of the yield survey of the 1st year, all treatment groups did not show a significance in yield compared to the NT. In case of 2nd year, all treatment groups show significantly increased value compared to NT. The yield of MF was highest among the treatment groups. In the future, it is thought that it is necessary to quantitatively evaluate the effect of food waste dry powder mixed fertilizer through additional experiments and continuous cultivation, and to establish an appropriate amount of use and establishment of a manual based on this.

  • PDF

Development of Thermoplastic Carbon Composite Hybrid Bipolar Plate for Vanadium Redox Flow Batteries (VRFB) (바나듐 레독스 흐름전지용 열가소성 탄소 복합재료 하이브리드 분리판 개발)

  • Jun Woo Lim
    • Composites Research
    • /
    • v.36 no.6
    • /
    • pp.422-428
    • /
    • 2023
  • The electrical contact resistance between the bipolar plate (BP) and the carbon felt electrode (CFE), which are in contact by the stack clamping pressure, has a great impact on the stack efficiency because of the relatively low clamping pressure of the vanadium redox flow battery (VRFB) stack. In this study, a polyethylene (PE) composite-CFE hybrid bipolar plate structure is developed through a local heat welding process to reduce such contact resistance and improve cell performance. The PE matrix of the carbon fiber composite BP is locally melted to create a direct contact structure between the carbon fibers of CFE and the carbon fibers of BP, thereby reducing the electrical contact resistance. Area specific resistance (ASR) and gas permeability are measured to evaluate the performance of the PE composite-CFE hybrid bipolar plate. In addition, an acid aging test is performed to measure stack reliability. Finally, a VFRB unit cell charge/discharge test is performed to compare and analyze the performance of the developed PE composite-CFE hybrid BP and the conventional BP.

Carbon nanotube field emission display

  • Chil, Won-Bong;Kim, Jong-Min
    • Electrical & Electronic Materials
    • /
    • v.12 no.7
    • /
    • pp.7-11
    • /
    • 1999
  • Fully sealed field emission display in size of 4.5 inch has been fabricated using single-wall carbon nanotubes-organic vehicle com-posite. The fabricated display were fully scalable at low temperature below 415$^{\circ}C$ and CNTs were vertically aligned using paste squeeze and surface rubbing techniques. The turn-on fields of 1V/${\mu}{\textrm}{m}$ and field emis-sion current of 1.5mA at 3V/${\mu}{\textrm}{m}$ (J=90${\mu}{\textrm}{m}$/$\textrm{cm}^2$)were observed. Brightness of 1800cd/$m^2$ at 3.7V/${\mu}{\textrm}{m}$ was observed on the entire area of 4.5-inch panel from the green phosphor-ITO glass. The fluctuation of the current was found to be about 7% over a 4.5-inch cath-ode area. This reliable result enables us to produce large area full-color flat panel dis-play in the near future. Carbon nanotubes (CNTs) have attracted much attention because of their unique elec-trical properties and their potential applica-tions [1, 2]. Large aspect ratio of CNTs together with high chemical stability. ther-mal conductivity, and high mechanical strength are advantageous for applications to the field emitter [3]. Several results have been reported on the field emissions from multi-walled nanotubes (MWNTs) and single-walled nanotubes (SWNTs) grown from arc discharge [4, 5]. De Heer et al. have reported the field emission from nan-otubes aligned by the suspension-filtering method. This approach is too difficult to be fully adopted in integration process. Recently, there have been efforts to make applications to field emission devices using nanotubes. Saito et al. demonstrated a car-bon nanotube-based lamp, which was oper-ated at high voltage (10KV) [8]. Aproto-type diode structure was tested by the size of 100mm $\times$ 10mm in vacuum chamber [9]. the difficulties arise from the arrangement of vertically aligned nanotubes after the growth. Recently vertically aligned carbon nanotubes have been synthesized using plasma-enhanced chemical vapor deposition(CVD) [6, 7]. Yet, control of a large area synthesis is still not easily accessible with such approaches. Here we report integra-tion processes of fully sealed 4.5-inch CNT-field emission displays (FEDs). Low turn-on voltage with high brightness, and stabili-ty clearly demonstrate the potential applica-bility of carbon nanotubes to full color dis-plays in near future. For flat panel display in a large area, car-bon nanotubes-based field emitters were fabricated by using nanotubes-organic vehi-cles. The purified SWNTs, which were syn-thesized by dc arc discharge, were dispersed in iso propyl alcohol, and then mixed with on organic binder. The paste of well-dis-persed carbon nanotubes was squeezed onto the metal-patterned sodalime glass throuhg the metal mesh of 20${\mu}{\textrm}{m}$ in size and subse-quently heat-treated in order to remove the organic binder. The insulating spacers in thickness of 200${\mu}{\textrm}{m}$ are inserted between the lower and upper glasses. The Y\ulcornerO\ulcornerS:Eu, ZnS:Cu, Al, and ZnS:Ag, Cl, phosphors are electrically deposited on the upper glass for red, green, and blue colors, respectively. The typical sizes of each phosphor are 2~3 micron. The assembled structure was sealed in an atmosphere of highly purified Ar gas by means of a glass frit. The display plate was evacuated down to the pressure level of 1$\times$10\ulcorner Torr. Three non-evaporable getters of Ti-Zr-V-Fe were activated during the final heat-exhausting procedure. Finally, the active area of 4.5-inch panel with fully sealed carbon nanotubes was pro-duced. Emission currents were character-ized by the DC-mode and pulse-modulating mode at the voltage up to 800 volts. The brightness of field emission was measured by the Luminance calorimeter (BM-7, Topcon).

  • PDF

Source Term Characterization for Structural Components in $17{\times}17$ KOFA Spent Fuel Assembly ($17{\times}17$ KOFA 사용후핵연료집합체내 구조재의 방사선원항 특성 분석)

  • Cho, Dong-Keun;Kook, Dong-Hak;Choi, Heui-Joo;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.8 no.4
    • /
    • pp.347-353
    • /
    • 2010
  • Source terms of metal waste comprising a spent fuel assembly are relatively important when the spent fuel is pyroprocessed, because cesium, strontium, and transuranics are not a concern any more in the aspect of source term of permanent disposal. In this study, characteristics of radiation source terms for each structural component in spent fuel assembly was analyzed by using ORIGEN-S with a assumption that 10 metric tons of uranium is pyroprocessed. At first, mass and volume for each structural component of the fuel assembly were calculated in detail. Activation cross section library was generated by using KENO-VI/ORIGEN-S module for top-end piece and bottom-end piece, because those are located at outer core with different neutron spectrum compared to that of inner core. As a result, values of radioactivity, decay heat, and hazard index were reveled to be $1.40{\times}10^{15}$ Bequerels, 236 Watts, $4.34{\times}10^9m^3$-water, respectively, at 10 years after discharge. Those values correspond to 0.7 %, 1.1 %, 0.1 %, respectively, compared to that of spent fuel. Inconel 718 grid plate was shown to be the most important component in the all aspects of radioactivity, decay heat, and hazard index although the mass occupies only 1 % of the total. It was also shown that if the Inconel 718 grid plate is managed separately, the radioactivity and hazard index of metal waste could be decreased to 20~45 % and 30~45 %, respectively. As a whole, decay heat of metal waste was shown to be negligible in the aspect of disposal system design, while the radioactivity and hazard index are important.

Sterilization of Neurospora Crassa by Noncontacted Low Temperature Atmospheric Pressure Surface Discharged Plasma with Dielectric Barrier Structure (유전체장벽 방전구조의 비접촉식 저온 대기압 면방전 플라즈마를 이용한 빵곰팡이의 살균효과)

  • Ryu, Young Hyo;Uhm, Han Sup;Park, Gyung Soon;Choi, Eun Ha
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.2
    • /
    • pp.55-65
    • /
    • 2013
  • Sterilization of Neurospora crassa has been investigated in this research by using a surface air plasma with dielectric barrier discharged (DBD) structure under atmospheric pressure. The sinusoidal alternating current has been used in this experiment with discharge voltage of 1.4~2.3 kV. The phase difference between the voltage and current signals are found to be almost 80 degree due to the capacitive property of dielectric barrier. Temperature on the biomaterials has been minimized by radiating the heat with the air cooling system. It is noted that the substrate temperature remains under 37 degree for plasma exposure time of 10 minutes with operation of cooler system. It is found that the ozone, $O_3$, has been measured to be about 25~30 ppm within 1 cm region and to be about 5 ppm at the 150 cm downstream region away from the suface plasma. It is also noted that the nitric oxide, NO, and nitric dioxide, $NO_2$, are not nearly detected. Germination rate and mitochodrial activity of Neurospora crassa immersed in the deionized water have been found to be drastically decreased as the plasma treatment time and its electrical power are increased in this experiment. Here, the mitochondrial activity has been analyzed by MTT (3-(4,5-dimethy lthiazol-2yl)-2,5-diphenyl-2H-tetrazolium bromide) assay. However, sterilization of Neurospora crassa immersed in the Vogel's minimal media has been found to be low by plasma treatment, which is caused by surrounding background solution. This research shows the sterilization possibility of Neurospora crassa by using the noncontated surface DBD plasma, which is different from the plasma jet. This is mainly attibuted to the reactive species generated by the surface plasma, since they play a major role for inhibition of micobes such as Neurospora crassa.

Design of the self-oscillation UV flash lamp power supply and the characteristic of its operation using self-resonance of the transformer (트랜스포머의 자가 공진(Self-Resonance)특성을 이용한 자가 발진(Self-Oscillation) UV(Ultra Violet) 발생 플래시램프 전원장치설계 및 그 동작 특성)

  • Kim, Shin-Hyo;Cho, Dae-Kweon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.1
    • /
    • pp.48-55
    • /
    • 2014
  • These Xenon flashlamp power supply for Ultra Violet has converter with high voltage conversion ratio. General model is composed of transformer with high voltage conversion ratio and voltage doubler rectifier circuit. Purpose of power supply leads dielectric breakdown of Xenon flashlamp and passes current rapidly. When passing current, it has to limit current to avoid over-heat, damage of electrode and acceleration of gas oxidation which are cause of performance degradation of lamps. Generally, inductors and resistors, which are called as "Ballast," are used to limit currents. Generally, Transformer has high turn ratio to make high voltages. But we can get high voltages using the transformer with low turn ratio which is driven with self resonance. Also, an advantage of self resonance is to make a circuit simply through impedance of transformer in resonance frequency which filters output voltage. As using an unique impedance of transformer, the circuit does not need other impedance elements like the ballast. So the power supply assures high efficiency of the arc discharge.

Phase Change of Nanorod-Clustered $MnO_2$ by Hydrothermal Reaction Conditions and the Lithium-ion Battery Cathode Properties of $LiMn_2O_4$ Prepared from the $MnO_2$ (수열합성 조건에 따른 나노로드 클러스터형 $MnO_2$의 상변화와 이를 이용한 $LiMn_2O_4$의 리튬이온전지 양전극 특성)

  • Kang, Kun-Young;Choi, Min Gyu;Lee, Young-Gi;Kim, Kwang Man
    • Korean Chemical Engineering Research
    • /
    • v.49 no.5
    • /
    • pp.541-547
    • /
    • 2011
  • Nanorod-clustered $MnO_2$ precursors with ${\alpha}$-, ${\beta}$-, and ${\gamma}$-phases are synthesized by hydrothermal reaction of $MnSO_45H_2O$ and $(NH_4)S_2O_8$. The formation of nanorod-clustered ${\beta}-MnO_2$ is particularly confirmed under the conditions of high reactant concentration and hydrothermal reaction at $150^{\circ}C$. The spinel $LiMn_2O_4$ nanorod-clusters are also prepared by lithiating the $MnO_2$ precursors, varying the concentration of lithiating agent ($LiC_3H_3O_2{\cdot}2H_2O$) and heat treatment temperature, and characterized for use as cathode material of lithium-ion batteries. As a result, the nanorod-clustered $LiMn_2O_4$ prepared from the ${\beta}-MnO_2$ at higher $LiC_3H_3O_2{\cdot}2H_2O$ concentration and the annealing at $800^{\circ}C$ is proven to show the cubic spinel structure and to achieve the high initial discharge capacity of 120 mAh/g.

The Electrochemical Properties of Li4/3Ti5/3O4 Synthesized by Sol-Gel Process (졸-겔법에 의해 합성된 Li4/3Ti5/3O4의 전기화학적 특성)

  • Lee, Jin-Sik;Lee, Chul-Tae
    • Applied Chemistry for Engineering
    • /
    • v.10 no.1
    • /
    • pp.73-79
    • /
    • 1999
  • The superstructured $Li_{4/3}Ti_{5/3}O_4$ was prepared by sol-gel process using a mixed solution of lithium acetate (LA) and titanium n-butoxide (TNB). The gel phase was obtained by adding ammonia water ($NH_4OH/TNB$ mole ratio of 0.35) and water ($H_2O/TNH$ mole ratio of 3.5) into the clear sol that was prepared after mixing TNB/LA mole ratio of 5/4 with AA/TNB mole raio of 0.125. It was found that the most suitable $Li_{4/3}Ti_{5/3}O_4$ was obtained by heat treatment of xerogel at $600^{\circ}C$ for 30 hrs. The synthesized $Li_{4/3}Ti_{5/3}O_4$ showed an initial discharge capacity of 174 mAh/g and the capacity loss of about 27.3% during 25 cycles in Li/1M $LiClO_4(in\;PC)/Li_{4/3}Ti_{5/3}O_4$ at current density of $0.15mA/cm^2$ and the voltage range of 0.5~3.0 V.

  • PDF

The Clinical Study of Biyun(sinusitis) in Children (소아비연(小兒鼻淵)에 대(對)한 임상적(臨床的) 연구(硏究))

  • Park Eun-Jeong;Lee Hae-Ja
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.12 no.1
    • /
    • pp.111-131
    • /
    • 1998
  • 1. In oriental medicine, the case of sinusitis can be explained, not only external invasion such as PUNG HAN(wind-cold), PUNG YUL(wind-hot), SHUP YUL(damp-heat), but also functional disorder of internal organ such as spleen(脾), lung(肺), kidney(腎) The western medicine classified the cause of sinusitis as two factors. That is bacterial infection factor-Haemophilus influenza, streptococcus pyogeues, streptococcus pneumonia- and viral infection factor-Rhinovirus, parainfluenza, Echo28, Coxsacki21, Sinusitis is complicated to allergic rhinitis, chronic otitis media purulent, chronic tonsilitis, sinubronchitis. On the condition of nasal septum deformity, turbinates deformity, nasal septum deviation, sinusitis can be developed. the predisposing factors of sinusitis is swimming, air pollution, malnutrition, shortage of immunity.2. According to survey, sinusitis occurred that children from 4 to 12 years old and from 5 to 7 years old occupied 70% 3. From the past history data, they experienced chronic tonsillar hypertropy(20%), otitis media, atopic dermatitis, allergic rhinitis, bronchial asthma, pneumonia, bronchiolitis, chronic sore throat, urticaria, milk allergy in sequence. 4. the symptoms of sinusitis is nasal obstruction, postnasal dripping, purulunt(yellow)or white discharge, cough, nose bleeding in sequence. nasal obstruction take the portion of 95%, postnasal dripping 65%, night time or early morning cough 60%. 5. The suffering period of sinusitis is 6 month minimum, 4 years maximum, most cases are included in a year. The suffering period of children was shorter than adult. 6. Diagnosis depend on inspection of nasal cavity, postnasal dripping, X-ray finding. 75% of patient(15case) showed both maxillary sinusitis, 25%(5cases) showed left or right maxillary sinusitis. 7. Treatment of oriental medicine, consist of Herb-medicine, acupuncture and exposing of Lazer beam. Kamihyunggyeyungyotang(加味荊芥蓮翹湯) is administered mainly as the medical therapy, Kamigwaghyangjeungkisan(加味藿香正氣散) Kimizwakwieum(加味左歸飮), Kamihyangsosan(加味香蘇散) is administered for a additional symptoms which occurred by influenza recurrence. Kamijeonxibackchulsan(加味錢氏白朮散) is administered to treat gastro-intestine trouble patients who have sinusitis. 8. The period of treatment is varied with patient conditions and X-ray finding. The minimal period is 35days, maximal period is 202days. So it took about 86days in average and about 50% of patient(10cases) is recovered in one or two month.

  • PDF