• Title/Summary/Keyword: Heat chamber

Search Result 735, Processing Time 0.025 seconds

Experimental Study of Film Cooling in Liquid Rocket Engine(III) (액체로켓엔진의 막냉각에 관한 실험적 연구(III))

  • Yu Jin;Choi Younghwan;Park Heeho;Ko Youngsung;Kim Yoo
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • v.y2005m4
    • /
    • pp.203-207
    • /
    • 2005
  • An experimental study was carried out to investigate the effect of film cooling in the thrust chamber of liquid rocket using LOx and Kerosene as propellant. The heat fluxes were obtained from the measured wall temperature to the axial direction of thrust chamber for different type of coolant, the various O/F ratio, mass flow rate and the location of the film cooling injector. A thin wall combustion chamber and nozzle were used to obtain the heat flux.

  • PDF

A Study for the Improvement of Start Ability and Exhaust Emissions in a Conventional Mixer Type LPG Engine on Cold Start (LPG 엔진의 냉 시동시 시동성 개선 및 배출들 저감을 위한 연구)

  • 김우석;이종화
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.1
    • /
    • pp.84-92
    • /
    • 2002
  • On the cold start of LPG engine, as the engine temperature has not reached its equilibrium temperature, liquid LPG could not be changed perfectly gaseous LPG, although it was passed to the vaporizer. Liquid and gas mixed fuel could influence starting ability and exhaust emission characteristics of LPG engine. In this study, the vaporization characteristic of liquid LPG was investigated with a conventional vaporizer and the vaporizer with heat source(glow plug) installed at preheated chamber inlet, by using the visualization methods and engine test. According to visualization result, even if the engine coolant temperature was $14^{\circ}C$, liquid fuel was supplied to primary chamber over 25 seconds without vaporizing from preheated chamber in such a conventional vaporizer. However, the vaporizer with heat source do not correspond with that, scarcely had been trim on glow plug when LPG began to vaporize. The effectiveness of heat source could be verified by application to the conventional LPG engine.

An Isothermal Temperature Source with a Large Surface Area using the Metal-Etched Microwick-Inserted Vapor Chamber Heat Spreader

  • Go, Jeong-Sang;Kim, Kyung-Chun
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.4
    • /
    • pp.681-688
    • /
    • 2004
  • For use of the thermal cycle of the biochemical fluid sample, the isothermal temperature source with a large surface area was designed, fabricated and its thermal characterization was experimentally evaluated. The comprehensive overview of the technology trend on the temperature control devices was detailed. The large surface area isothermal temperature source was realized by using the vapor chamber heat spreader. The cost-effectiveness and simple manufacturing process were achieved by using the metal-etched wick structure. The temperature distribution was quantitatively investigated by using IR temperature imaging system at equivalent temperatures to the PCR thermal cycle. The standard deviation was measured to be within 0.7$^{\circ}C$ for each temperature cycle. This concludes that the presented isothermal temperature source enables no temperature gradient inside bio-sample fluid. Furthermore it can be applied to the cooling of the electronic devices due to its slimness and low thermal spreading resistance.

Cooling Performance Analysis of Sub-scale Calorimeter (축소형 칼로리미터의 냉각성능 해석)

  • 조원국;문윤완
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2003.05a
    • /
    • pp.9-12
    • /
    • 2003
  • A cooling performance analysis has been made in the 8-channel calorimeter based on sub-scale KSR-III engine. Three-dimensional heat transfer analysis in cooling channels has been performed using the heat flux distribution through the chamber wall predicted from axi-symmetric compressible flow inside the combustion chamber. The heat flux distribution was verified against the published literature. Presented for the development and operation of the calorimeter are the coolant pressure drop, coolant temperature rise and the maximum chamber wall temperature.

  • PDF

Energy Performance Analysis of Electric Heater and Heat Pump Food Dryers (전기히터식 및 히트펌프식 식품 건조기의 에너지 성능 비교)

  • Yu, Young Woo;Kim, Young Il;Park, Seungtae
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.11 no.4
    • /
    • pp.1-6
    • /
    • 2015
  • In this study, energy performance of two types of food dryers which are electric heater and heat pump is studied experimentally. With drying chamber temperatures controlled at 45, 50 and $55^{\circ}C$, sliced radish is dried from an initial mass of 90 to final 7 kg. Moisture content, drying time, total power consumption, MER (moisture extraction rate, kg/h) and SMER (specific moisture extraction rate, kg/kWh) are measured and analyzed. As the drying chamber temperature is increased, drying time is shortened but energy efficiency is reduced for both types. For an electric heater dryer, the effect of chamber temperature on drying time is significant but less significant on energy efficiency. For a heat pump dryer, the dependence of chamber temperature on drying time is weak but strong on energy efficiency. Temperature levels have little effect on electric heater dryer performance but strong effect on heat pump dryer which operates on a vapor compression refrigeration cycle. The energy performance of the heat pump dryer is superior with an average SMER of 2.175 kg/kWh which is 2.22 times greater than that of the electric heater dryer with SMER of 1.224 kg/kWh.

Film cooling Effects on Wall Heat Flux of a Subscale Calorimetric Combustion Chamber (막냉각량에 따른 축소형 칼로리미터의 열유속 특성에 관한 연구)

  • Kim, Jong-Gyu;Lim, Byoung-Jik;Seo, Seong-Hyeon;Han, Yeoung-Min;Kim, Hong-Jip;Choi, Hwan-Seok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.10 no.4
    • /
    • pp.93-99
    • /
    • 2006
  • The effects of the changes of a film cooling mass flow rate and operating conditions on wall heat flux characteristics of a subscale calorimetric combustion chamber were investigated by experiment and numerical analysis. At the nominal operating condition, with the film cooling mass flow rate being 10.5 percent of a main fuel mass flow rate, maximum heat flux at the nozzle throat was measured to be 30 percent lower than that without the film cooling. For the relatively higher mixture ratio and chamber pressure condition, maximum heat flux at the nozzle throat was increased by 31 percent compared to that of the nominal condition test without film cooling.

Numerical Study on Combined Heat Transfer in NIR Dryer for Agricultural and Marine Products (근적외선 농수산물 건조기의 복합열전달특성에 관한 수치적 연구)

  • Choi, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.395-402
    • /
    • 2006
  • Mixed heat transfer in an indirected NIR (Near Infrared Ray) dry chamber was investigated numerical analysis. It is Important that the miked heat transfer effects on double parameters which the Reynolds number and the position of emit lamp. Reynolds number are based on the outer diameter of the cylinder range from 103 to $30{\times}105$. Four difference heat transfer regimes of behavior are apparent: forced convection and radiation on the outer surface of the cylinder, pure conduction, pure natural convection and radiation between lamp surface and inner surface of the cylinder. The temperature and flow patterns are illustrated by iso-contour lines for the double parameters. Also presented are results on the convective heat transfer flux and the radiative heat transfer flux as increased with Reynolds number.

A Study on the Effects of Induced Mixture Flows and the Stratified Charge for a Lean Burn (희박연소를 위한 혼합기의 성층급기와 유동에 관한 연구)

  • 전대수;이태원;윤수한;하종률
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.1
    • /
    • pp.1-9
    • /
    • 2000
  • In the present study, the IDI-type constant volume chamber, which utilizes the indirect injection stratified charge method, is used to solve several problems including misfires and cycle-variations caused by unstable initial ignitions. A subchamber has been used to make an ignitable mixture under the low mean equivalence ratio. After burned in the subchamber, the flame jet getting through the passage hode enters the main chamber and burns the lean charge. There are many factors which affect the combustion characteristics of the indirect injection stratified engine. The passage hole angle is the most important since it determines the direction of flame flows into the main chamber. In the present study, we measured the combustion pressure, and the wall temperature, and computed the heat flux through the cylinder wall in order to understand the combustion characteristics depending on passage hole angle and the equivalence ratio.

  • PDF

Combustion Analysis in a Pro-Combustion Chamber Diesel Engine by Approximate Heat Release Rate (근사적 열발생율에 의한 예연소실식 디젤기관의 연소해석)

  • 왕우경
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.29 no.1
    • /
    • pp.30-38
    • /
    • 1993
  • In this study, the combustion characteristics in a pre-combustion chamber diesel engine was investigated with experimental conditions of marine engine load. The heat release analysis used was a single-zone single-chamber thermodynamic analysis based on pre-combustion chamber pressure-time data. Based on the results of this investigation, the following conclusions were reached: 1) Increasing the load, peak pressure was increased and position of P sub(max) was retarded in crank angle degrees. 2) Ignition delay time was almost constant without relating to the load and the heat values to form a combusitible mixture were decreased apparently with increasing the load. 3) In premixed-combustion mode, the pattern of heat release rate was resembled without relating to the load and premixed-combustion time was shortened with increasing the load. 4) Increasing the load, mass of premixed-burned fuel was increased slightly, but was invariable beyond a certain fuel-air ratio. 5) Increasing the load, premixed-burned fraction was decreased.

  • PDF

Thermal and subjective responses by sun hats for farmer in a hot climatic chamber (서열 환경에서 농작업 모자 착용에 따른 체온 조절 및 주관적 반응)

  • 김명주;최정화
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.28 no.5
    • /
    • pp.713-722
    • /
    • 2004
  • This study examined the effects of two kinds of functional sun hats through a head-manikin test and a climatic chamber trial for farm workers in summer. Experiment was composed of four conditions. The first condition was the condition without any hat (Control). The second was the condition with a sun hat on the market (Hat A). The third was the condition with a functional sun hat made of reflective fabric (Hat B). The last was the condition with a functional sun hat having a ventilating structure as well as reflective fabric (Hat C). For the subjects in the climatic chamber trials, 12 healthy males volunteered. Air temperature, relative humidity and globe temperature in the chamber was maintained at $33{\pm}0.5^{\circ}C,\;65{\pm}5%RH\;and\;39{\pm}1^{\circ}C\;(WBGT\;33^{\circ}C)$. Subjects did a simulated red pepper-work (50-min work and 10-min rest, twice repetition) for 120 min. As the result of head-manikin test, the surface temperature on middle of back-neck was the lowest in Hat B of four conditions and the surface temperature on top of head was the lowest in Hat C. As the result of climatic chamber trials, there were apparent differences between with (Hat A, Hat B, Hat C) and without a sun hat (Control). In rectal temperature ($T_{re}$), mean skin temperature ($\={T}_{sk}$), heart rate (HR), total sweat rate (TSR), The physiological heat strain was less in the condition with hats than in the condition without a sun hat. As the increasing rate in Tre, Hat B is the most effective hat for alleviation heat strain. As the subjective responses, Hat B was the most effective hat for thermal comfort even though the difference was not significant. Hat C was less effective than Hat B and the reason might be the increase of weight due to inserting the ventilating structure.