• Title/Summary/Keyword: Heat chamber

Search Result 735, Processing Time 0.033 seconds

Numerical Study on Heat Transfer Characteristic in Combustor Nozzle (추진기관 노즐의 열전달 특성에 관한 수치적 연구)

  • Namkoung, Hyuck-Joon;Han, Poong-Gyoo;Lee, Kyoung-Hoon;Kim, Young-Soo;Jeong, Hae-Seung
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.275-281
    • /
    • 2007
  • For a cooling performance research of the combustor operated in a extreme environment of a high temperature and high pressure, we accomplished a cooling performance analysis. Generally a heat transfer characteristic in cooling passage is known well experimentally and theoretically, however heat flux in the combustion chamber isn't. In this study, fluid flow combined with heat transfer analysis is accomplished about a combustor nozzle. We tried to analyze the cooling performance with a heat transfer characteristic of a gas and coolant side in the view point of quantity on the mass flow rate to be supplied to the cooling channel. And finally, evaluation on the thermal safety of nozzle wall material was accomplished.

  • PDF

Development of an insulation performance measurement unit for full-scale LNG cargo containment system using heat flow meter method

  • Lee, Jin-sung;Kim, Kyung-su;Kim, Yooil
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.10 no.4
    • /
    • pp.458-467
    • /
    • 2018
  • Efforts have been made in this paper to develop the measuring device for the insulation performance of full scale NO96 LNG CCS. The facility was designed to maintain environmental conditions which are similar to operation conditions of full scale LNG CCS. In the facility, the heat sink boundary was kept cryogenic temperature by cold chamber which contains liquefied nitrogen and heat source boundary was made by external case heated by natural convection. Heat Flow Meter method (HFM) was applied to this facility, hence Heat Flux Sensors (HFS) were attached to specimen. The equivalent thermal conductivity of full scale NO96 unit box was targeted to measure and PUF of same size was used for the calibration test. Additionally, the finite element analysis was carried out to check the performance of the developed test facility and experimental results were also compared with those predicted by the numerical method.

Metabolic Heat Production and Rectal Temperature of Newborn Calves

  • Mundia, C.M.;Yamamoto, S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.10 no.3
    • /
    • pp.304-307
    • /
    • 1997
  • Rectal temperature (Tr), skin surface temperatures (Ts), and heart rate (HR) were measured continuously from birth (day 1) till day 7, while resting heat production (HP) was measured in a chamber on days 1, 3, 5 and 7, in order to study the characteristic variation of Tr in newborn calves by heat balance methods. Despite constant levels of milk being given to the newborn calves each day, daily mean resting HP was lowest on the day of birth, then increased to peak on day 3 and then decreased slightly thereafter. Daily mean HR was higher on days 2, 3 and 4, than on other days. Tr exhibited diurnal rhythms and daily mean Tr was low on day 1, high on day 3, and then decreased slightly after day 3. Daily average mean skin temperature (mTs) was similar on all days. Mean body temperature (Tb) exhibited diurnal rhythms and had a similar range between days, suggesting that heat balance and thermoregulation were carried out effectively on each day. The variation of Tb appeared to be synchronized with that of HP and suggested that newborn calves might use variations in the levels of Tb to facilitate the body's required levels of heart loss.

Prediction of Spatial Heat Release Rate of Combustion Chamber by Radicals-PLIF (라디칼 PLIF계측을 이용한 연소실의 공간적 열발생율 예측)

  • Choi, G.M.
    • Journal of ILASS-Korea
    • /
    • v.8 no.4
    • /
    • pp.9-16
    • /
    • 2003
  • The Purpose of this study is to investigate the relationships between the local heat release rate and CH concentration have been investigated by numerical simulations of methane-air premixed flames. And simultaneous CH and OH PLIF(Planar Laser Induced Fluorescence) measurement has been also conducted for lean premixed flame as well as for laminar flames. Numerical simulations are conducted for laminar premixed flames and turbulent ones by using PREMIX in CHEMKIN and two dimensional DNS code with GRI mechanism version 2.11, respectively. In the case of laminar premixed flame, the distance between the peak of heat release rate and that of CH concentration is under $91{\mu}m$ for all equivalence ratio calculated in present work. Even for the premixed flame in high intensity turbulence, the distribution of the heat release rate coincides with that of CH mole fraction. For CH PLIF measurements in the laminar premixed flame burner, CH fluorescence intensity as a function of equivalence ratio shows a similar trend with CH mole fraction computed by GRI mechanism. Simultaneous CH and OH PLIF measurement gave us useful information of instantaneous reaction zone. In addition, CH fluorescence can be measured even for lean conditions where CH mole fraction significantly decreases compared with that of stoichiometric condition. It was found that CH PLIF measurements can be applicable to the estimation of the spatial fluctuations of heat release rate in the engine combustion.

  • PDF

A Study on the Performance Improvement of a Heat Pump System with a Dehumidification Function (제습기능을 구비한 열펌프의 성능개선에 관한 연구)

  • Ko, Gwang-Soo;Kim, Taehyung;Park, Youn Cheol
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.11
    • /
    • pp.529-534
    • /
    • 2014
  • This research developed a hybrid heat pump system with the functions of dehumidification and heating, which uses simulated air that is like underground air, from an environmental chamber as a heat source. The system consisted of three evaporators and three condensers that were installed in series in the air passage, between the underground and load space. As results, the total amount of dehumidification was 2.726 kg/h, and the heating $COP_h$ was 1.84 at air intake temperature $17^{\circ}C$ and relative humidity 70%, which is a similar condition to underground air. We found that the total amount of dehumidification also increased with the air temperature and humidity. The system $COP_s$ was reached at 2.5, if we include the latent heat of dehumidification in the conventional heat pump system's COP.

Improvement of Temperature Uniformity in a Hot Plate for Thermal Nanoimprint Lithography by Installing Heat Pipes (히트 파이프를 이용한 열경화성 나노임프린트 장비용 열판의 온도 균일도 향상)

  • Park, Gyu Jin;Yang, Jin Oh;Lee, Jae Joong;Kwak, Ho Sang
    • Journal of the Semiconductor & Display Technology
    • /
    • v.15 no.2
    • /
    • pp.74-80
    • /
    • 2016
  • This study presents a thermal device specially designed for thermal nanoimprint lithography equipments, which requires the capability of rapid heating and cooling, high temperature uniformity and the material strength to endure high stamping pressure. The proposal to meet these requirements is a planar-type hot plate extensible to a large area, in which long circular cartridge heaters and heat pipes are installed inside in parallel. The heat pipes are connected to the outside water cooling chamber. A hot plate made of stainless steel is fabricated with a dimension $240mm{\times}240mm{\times}20mm$. Laboratory experiments are conducted to examine the thermal performance of the hot plate. The results illustrate that the employment of heat pipes leads to a notable enhancement of temperature uniformity in the device and provides an efficient heat delivery from the hot plate to outside. It is verified that the suggested hot plate could be a feasible thermal tool for thermal nanoimprint lithography, satisfying the major design requirements.

Experimental Study on Heat Transfer Characteristics of Jet A-1 Fuel (Jet A-1 연료의 열전달 특성에 관한 실험적 연구)

  • Lee, Junseo;Lee, Bom;Ahn, Kyubok
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.5
    • /
    • pp.1-12
    • /
    • 2020
  • In this paper, the heat transfer characteristics of Jet A-1, which is used as a coolant and fuel in a regeneratively cooled thrust chamber, were experimentally studied. By varying the applied current for heating the cooling channel, the simulated specimen diameter, the specimen outlet pressure and the coolant flow rate, the wall temperatures of the specimen and the Jet A-1 temperatures at the specimen inlet/outlet were measured. It was found that the specimen diameter and the flow rate were important factors for the characteristics of heat transfer and the outlet pressure did not affect the performance of heat transfer. The results of the heat transfer experiments were compared with the previous Nusselt number empirical equations and novel Nusselt number empirical equations were finally derived.

Evaluation of yield and growth responses on paddy rice under the extremely high temperature using temperature gradient field chamber (온도구배야외챔버를 이용한 고온에서의 벼 생육반응 및 수량성 평가)

  • Oh, Dohyeok;Ryu, Jae-Hyun;Cho, Yunhyeong;Kim, Wonsik;Cho, Jaeil
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.1
    • /
    • pp.135-143
    • /
    • 2018
  • The effect of elevated temperature on temperate paddy rice will be significant for dependable food supply in East Asia. Using temperature gradient field chamber (TGFC), which was designed to make the horizontal air temperature gradient by $0^{\circ}C$ to $3^{\circ}C$ higher than outside, we examined the measurement to understand the effects of extremely high temperature on paddy rice. In particular, the data of the year 2016, the worst heat wave in over 22 years, was analyzed in this study. The rice height in the relatively warmed condition was rapidly increased during early growth stage. However, the average grain weight and number of spikelet per panicle in the warmed chamber condition were gradually declined with increasing air temperature averaged for 40 days after first heading in each chamber. In particular, the grain yield was more dramatically decreased by the raising temperature because the percent ripened grain was quickly dropped as getting over the threshold temperature for pollination. Therefore, the surplus photosynthetic product by such lower grain filling rate may disturbed the decreases of the NDVI (Normalized Difference Vegetation Index) and SPAD chlorophyll values after first (normal) heading. In addition, the late-emerging head grain were appeared. However, this yield was too small to recover the normal yields decreased by extremely high temperature condition. Our result represented that the warmed condition in 2016 would be the critical limit for the stable yield of temperate paddy rice.

Experimental Study of the Behavior Characteristics of Actuator Diaphragms in Thermopneumatic Micropumps (열공압형 마이크로펌프의 액추에이터 박막 거동 특성에 관한 실험적 연구)

  • Lee, Jong-Mun;Kim, Young-Deuk;Kim, Woo-Seung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.34 no.6
    • /
    • pp.599-606
    • /
    • 2010
  • In the present study, actuators with diaphragms of different thickness and chambers of different diameter are fabricated to examine experimentally how the behavior characteristics of the actuator diaphragm in a thermopneumatic micropump are affected by diaphragm thickness and chamber diameter under various operating conditions with different values of input voltage and frequency. The actuator comprises a microheater set on Pyrex glass, a chamber, and a diaphragm. For all values of the input energy, as the frequency decreases below 10 Hz, the maximum center deflection of the diaphragm greatly increases irrespective of diaphragm thickness and chamber diameter. At low frequencies, as the heat energy supplied to the chamber increases, the center of deflection of the diaphragm increases; the magnitude of deflection is high for thin diaphragms and for diaphragms whose chambers have small diameters. At frequencies higher than 10 Hz, all the design variables such as diaphragm thickness, chamber diameter, and the input energy have negligible effect on the center deflection of the diaphragm.

Basic Research of Non-Invasive Optical Transcutaneous pCo2 Gas Sensor & Analytic Equipment (비침습적 방법에 의한 광학식 Transcutaneous pCo2 가스센서 및 분석장치 개발을 위한 기초연구)

  • Kim, Do-Eok;Lee, Seung-Ha;Cho, Eun-Jong;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.4
    • /
    • pp.258-263
    • /
    • 2004
  • In this study, we carried out a basic study for the development of optical transcutaneous $pCO_{2}$ gas sensor and analyzer using non-invasive method. The basic principle of $pCO_{2}$ measurement is adapted Beer lambert's law and embodied the system using NDIR method. This measuring system was composed of a IR lamp, a optical filter, a optical reaction chamber, pyroelectric sensor and a signal process. We measured $EtCO_{2}'s$ concentration in basis step instead of $pCO_{2}$ gas that can collect by inflicting heat in outer skin. We minimize the size of optical reaction chamber which takes up the largest volume, to make the portable sensor. We made optical reaction chamber in Si wafer using MEMS technology and the optical reaction chamber was shortened to 2 mm and we carried out an experiment. When we injected the $EtCO_{2}$ to the inside of the optical reaction chamber, we could confirm change of 4.6 mV. The system response time was within 2 second that is fairly fast.