• 제목/요약/키워드: Heat amount

검색결과 2,374건 처리시간 0.026초

가정용 공조기의 응축기 적용 알루미늄 열교환기의 성능 평가 (Performance evaluation of brazed aluminum heat exchangers for a condenser in residential air-conditioning applications)

  • 김만회;김권진
    • 설비공학논문집
    • /
    • 제10권1호
    • /
    • pp.44-55
    • /
    • 1998
  • The evaluation of aluminum flat tube and louver fin heat exchangers for a condenser in residential air-conditioning applications has been conducted. A series of tests for two-different brazed aluminum heat exchangers was performed and the results were compared with conventional fin and tube heat exchangers for residential air-conditioning system. Refrigerant charge amount for a window-system air-conditioner with the brazed aluminum condenser is decreased by 35% and the volume and material of heat exchanger can be reduced by 50% compared to the conventional fin and tube heat exchangers.

  • PDF

가열처리에 따른 우유와 달걀의 Allegenicity의 변화와 소화율에 관한 연구 (Changes in Allergenicity and Digestibility of Egg and Milk by Heat Treatment)

    • 동아시아식생활학회지
    • /
    • 제11권2호
    • /
    • pp.104-111
    • /
    • 2001
  • The first purpose of this study was to determine the changes in the allergenicity of milk and egg with heat treatment. The allergenicity of milk and egg is known to have a strong antigen. The second purpose of this study was to observe changes of disestibility of milk and egg after heat treatment. For this study, passive cutaneous anaphylaxis(PCA) inhibition experiment by using guinea pig and nonprotein nitrogen(NPN)experiment were attempted. The result were following: 1. The allergenicity of both milk and egg was reduced by heat treatment. 2. The degree of hydrolysis and PCA inhibition increased with longer heating time. 3. The increse in both the degree of hydrolysis and PCA inhibition of milk was higher than that of egg. 4. Egg contained a greater amount of allergen than milk after heat treatment. 5. The digestibility of both milk and egg was reduced by heat treatment. 6. The digestibility was reduced further by increasing heating time. 7. The digestibility of egg was lower than that of milk after the treatment.

  • PDF

오스테나이트계 스테인레스강의 육성 용접부에서 고온균열 감수성에 미치는 용접입열의 영향

  • 김대영;김희진
    • Journal of Welding and Joining
    • /
    • 제6권2호
    • /
    • pp.40-46
    • /
    • 1988
  • The effect of heat input on the content of residual .delta.-ferrite and the hot cracking susceptibility in the austenitic stainless steel overlaid on the carbon steel was studied in the range of heat input from 7.5 to 15.1 KJ/cm. Present study shows that residual .delta.-ferrite content in the overlay is mainly determined by the dilution of the base metal (carbon steel) which is in turn affected by heat input, i.e. the amount of dilution decreases as heat input increase. Accordingly, higher heat input results in a substantial increase in Cr equivalent but a little increase in Ni equivalent due to the less dilution of carbon from base metal. This fact can explain the result obtained in this study, i, e, the higher content of .delta.-ferrite in the weld deposit made with higher heat input. This in turn causes more resistant overlaying weld metal to hot cracking.

  • PDF

온실 냉방을 위한 히트펌프의 성능 분석 (Performance Analysis of Heat Pump System for Greenhouse Cooling)

  • 윤용철;서원명;이석건
    • 한국농공학회지
    • /
    • 제43권6호
    • /
    • pp.120-126
    • /
    • 2001
  • This experiment was carried out to analyse on the cooling and dehumidifying effects of greenhouse by air-to-water heat pump system employing the air as cooling source. following results were obtained ; 1. The coefficients of performance (COP) of heat pump itself and total heat pump system were approximately 2.71~2.88 and 1.99~2.22, respectively. 2. The night-time cooling load of experimental greenhouse was 64.9 MJ/h, and the heat absorbed (cooling load) from heat pump system was 816.3~1,004.6 MJ/day. 3. The dehumidified moisture amount from experimental greenhouse was 7.0~15.0 kg/h. 4. The night time temperature of experimental greenhouse cooled by heat pump system could be maintained 4~6$^{\circ}C$ lower than that of control greenhouse which was almost equal to outside air temperature.

  • PDF

온도측정에 의한 히트파이프의 수명예측 (Prediction of Life of Heat Pipes by Measuring Temperature Distribution)

  • 신흥태;;이윤표
    • 대한기계학회논문집B
    • /
    • 제23권7호
    • /
    • pp.856-863
    • /
    • 1999
  • The thermal performance degradation of heat pipes is caused by the non-condensable gas generation mainly due to the electrochemical corrosion which results from the reaction of working fluids with tube materials. In this study, a simplified method described below was proposed to estimate the life of heat pipes concerning the non-condensable gas generation. The temperature distributions at the outer surface of heat pipes was measured, and based on them the amount of non-condensable gas of hydrogen was estimated. Applying it to the Arrhenius model, the mass generation of hydrogen and the volume occupied by the gas In heat pipes could be estimated for an operating temperature and time. Moreover, this simplified method was applied to the accelerated life test of nine methanol-stainless steel heat pipe samples.

마이크로채널과 핀 튜브 열교환기를 적용한 가정용 에어컨디셔너의 성능 평가 (Evaluation of Performance of a Residential Air-Conditioning System Using Microchannel and Fin-and-Tube Heat Exchanger)

  • 윤린
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.28-35
    • /
    • 2007
  • In this study the seasonal performance of a residential air conditioning system having either a fin-and-tube condenser or a microchannel condenser is experimentally investigated. A commercially available 7 kW capacity residential air conditioning system having a fin-and-tube condenser served as the base system. The test results show that the system with a microchannel heat exchanger has a reduced refrigerant charge amount of 10%, the coefficient of performance is increased by 6% to 10%, and the SEER is increased by 7% as compared with those of the base system. Moreover, the condensing pressure of the system is decreased by 100 kPa and the pressure drop across the condenser is decreased by 84%. The microchannel heat exchanger enhances the SEER of the residential air conditioning system by providing better heat transfers at reduced pressure drops.

Cu-18wt% Cr 합금박막과 폴리이미드사이의 접착력 : 열처리 영향 (Adhesion between Cu-18wt% Cr Alloy Film and Polyimide : Effect of Heat Treatment)

  • 임준홍;김영호;한승희
    • 한국표면공학회지
    • /
    • 제26권6호
    • /
    • pp.327-333
    • /
    • 1993
  • The effect of heat treatment on the adhesion between Cu-18wt% Cr film and polyimide has been studied by using T-peel test, AES, and XRD. Cu-18wt% Cr alloy and pure Cu films were sputter deposited onto pol-yimide. Cu was electroplated before and after heat treatment at $400^{\circ}C$ for 0.5 hr and 2 hrs respectively. The adhesion of metal film onto polyimide was considerably good before heat treatment, but heat treatment re-duced the peel adhesion strength in all specimens. The reduction in adhesion in adhesion strength values in the specimens which were plated after heat treatment was mainly due to Cr-O rich pahse formed in the metal/polyimide in-terface. In the specimens which were heat treated after plating, the enhanced ductility in the metal films con-tributes the peel adhesion strength by increasing the amount of deformation in metal strips.

  • PDF

Direct-contact heat transfer of single droplets in dispersed flow film boiling: Experiment and model assessment

  • Park, Junseok;Kim, Hyungdae
    • Nuclear Engineering and Technology
    • /
    • 제53권8호
    • /
    • pp.2464-2476
    • /
    • 2021
  • Direct-contact heat transfer of a single saturated droplet upon colliding with a heated wall in the regime of film boiling was experimentally investigated using high-resolution infrared thermometry technique. This technique provides transient local wall heat flux distributions during the entire collision period. In addition, various physical parameters relevant to the mechanistic modelling of these phenomena can be measured. The obtained results show that when single droplets dynamically collide with a heated surface during film boiling above the Leidenfrost point temperature, typically determined by droplet collision dynamics without considering thermal interactions, small spots of high heat flux due to localized wetting during the collision appear as increasing Wen. A systematic comparison revealed that existing theoretical models do not consider these observed physical phenomena and have lacks in accurately predicting the amount of direct-contact heat transfer. The necessity of developing an improved model to account for the effects of local wetting during the direct-contact heat transfer process is emphasized.

열교환기 형상에 따른 분리형 히트파이프 성능 비교 (Separate type heat pipe performance comparison by the heat exchanger shapes)

  • 전성택;조진표
    • 한국산학기술학회논문지
    • /
    • 제17권12호
    • /
    • pp.723-729
    • /
    • 2016
  • 본 연구에서는 핀-관형 히트파이프와 평행류형 히트파이프 제작하여 시험하였으며 분리형 히트파이프의 작동유체의 충진량은 40~60(% vol.), 풍량은 300~1,400 사이에서 변화시켜가며 온도교환 효율, 열회수량, 공기측 압력강하를 비교하였다. 온도교환 효율은 두 종류의 히트파이프 모든 경우에서 저 풍량에서는 작동유체 충진량이 40(%vol.)일 때가 가장 높았으며 풍량이 증가함에 따라 최대 효율을 가지는 작동유체 충진량이 다름을 알 수 있었고, 환기량이 작을수록 온도교환 효율이 높게 나타났다. 평행류형 히트파이프 60(%vol.)의 실험결과에서 보는 것과 같이 작동 유체를 너무 많이 충진하게 되면 오히려 낮은 온도교환 효율을 보이는데 이는 관벽의 액막이 두터워지면서 열전달 효과를 악화시킨 결과로 최적 충진량이 40~50(%vol.) 사이에 있음을 알 수 있다. 풍량 변화에 따른 공기측 압력강하 비교에서는 증발부 히트파이프가 응축부 히트파이프 보다 크게 계측 되었는데 증발부 표면에 생긴 결로수의 영향으로 생각된다. 평행류형 히트파이프는 핀-관형 히트파이프와 비교하여 냉매 충진량은 48%, 체적은 41%에서 동등이상의 성능을 보였으며, 공기측 압력강하도 37% 정도로 좋은 성능을 나타내었다.

재 점화가 있는 가압식 추진기관의 액체산소 탱크 가압 헬륨량 산정 (Helium Quantity Estimation for LOx Tank Pressurization of a Restartable Pressure-fed Propulsion System)

  • 조규식;정영석;오승협
    • 한국추진공학회지
    • /
    • 제16권3호
    • /
    • pp.77-81
    • /
    • 2012
  • 극저온 추진제 탱크 속에서 가압 가스는 열손실에 의해 수축하고 추진제는 기화한다. 재 점화가 있는 추진기관의 경우 무추력 비행구간에서 극저온 추진제가 가압가스와 넓은 표면적으로 접촉하기 때문에 이러한 현상이 증대된다. 가압 가스량을 산정함에 있어 이러한 탱크 내부 열 물질 전달 현상을 고려하여야 한다. 무추력 비행구간에서 열 물질 전달 준 평형상태에 도달한다는 가정 하에 평형압력 계산절차를 제시하였다. 이를 적용하여 Falcon-1 발사체 2단에 탑재된 헬륨량을 산정하였다.