• Title/Summary/Keyword: Heat Transmission

Search Result 576, Processing Time 0.025 seconds

A Cost Analysis of the Heat Recovery Ventilator under Various Condition (열회수형 환기장치의 운전조건에 따른 경제성 평가에 관한 연구)

  • Kang, Tae-Wook;Koh, Jae-Yoon
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.1
    • /
    • pp.21-28
    • /
    • 2006
  • Changes in building construction methods and repairing of older buildings have reduced infiltration rate. Synthetic materials, release airborne particles and uneven healthy odor are increased. For preventing pollutants introduce fresh outdoor air into the building, simply letting fresh outdoor air into building, however, Is not a cost-effective way to ventilation. When additional ventilation is added to an existing HVAC system, the heating and cooling equipment, often cannot handle the increased load. A HRV provides a way to minimize in energy costs while introducing fresh air to a building. In this study, the economical research of HRV, made of three types of materials, are conducted. Heat recovering characteristics are studied at seasonal outdoor air conditions based on the outdoor air property condition at, Seoul in 2002. As a results, the average sensible effectiveness is 0.75 in the sensible heat exchanger and average total effectiveness is 0.65 in the total heat exchanger. The pay back period of the sensible heat exchangers are $3.2{\sim}3.5$ year and it of total heat exchanger is 2.2 years.

Microstructure Evolution and Its Effect on Strength during Thermo-mechanical Cycling in the Weld Coarse-grained Heat-affected Zone of Ti-Nb Added HSLA Steel (Ti-Nb첨가 저합금강 용접열영향부에서의 열-응력 이력이 미세조직 및 기계적 성질에 미치는 영향에 관한 연구)

  • Moon, Joonoh;Lee, Changhee
    • Journal of Welding and Joining
    • /
    • v.31 no.6
    • /
    • pp.44-49
    • /
    • 2013
  • The influence of thermo-mechanical cycling on the microstructure and strength in the weld coarse-grained heat affected zone (CGHAZ) of Ti-Nb added low carbon HSLA steel was explored through Vickers hardness tests, nanoindentation experiments, scanning electron microscopy (SEM) and transmission electron microscopy (TEM) analysis. Undeformed and deformed CGHAZs were simulated using Gleeble simulator with different heat inputs of 30kJ/cm and 300kJ/cm. At high heat input of 300kJ/cm, the CGHAZ consisted of ferrite and pearlite and then their grain sizes were not affected by deformation. At low heat input of 30kJ/cm, the CGHAZ consisted of lath martensite and then the sizes of prior austenite grain, packet and lath width decreased with deformation. In addition, the fraction of particle increased with deformation and this is because the precipitation kinetics was accelerated by deformation. Meanwhile, the Vickers and nanoindentation hardness of deformed CGHAZ with 30kJ/cm heat input were higher than those of undeformed CGHAZ, which are due to the effect of grain refinement and precipitation strengthening.

A Numerical Study of 1-D Surface Flame Spread Model - Based on a Flatland Conditions - (산불 지표화의 1차원 화염전파 모델의 수치해석 연구 - 평지조건 기반에서 -)

  • Kim, Dong-Hyun;Tanaka, Takeyoshi;Himoto, Keisuke;Lee, Myung-Bo;Kim, Kwang-Il
    • Fire Science and Engineering
    • /
    • v.22 no.2
    • /
    • pp.63-69
    • /
    • 2008
  • The characteristics of the spread of a forest fire are generally related to the attributes of combustibles, geographical features, and meteorological conditions, such as wind conditions. The most common methodology used to create a prediction model for the spread of forest fires, based on the numerical analysis of the development stages of a forest fire, is an analysis of heat energy transmission by the stage of heat transmission. When a forest fire breaks out, the analysis of the transmission velocity of heat energy is quantifiable by the spread velocity of flame movement through a physical and chemical analysis at every stage of the fire development from flame production and heat transmission to its termination. In this study, the formula used for the 1-D surface forest fire behavior prediction model, derived from a numerical analysis of the surface flame spread rate of solid combustibles, is introduced. The formula for the 1-D surface forest fire behavior prediction model is the estimated equation of the flame spread velocity, depending on the condition of wind velocity on the ground. Experimental and theoretical equations on flame duration, flame height, flame temperature, ignition temperature of surface fuels, etc., has been applied to the device of this formula. As a result of a comparison between the ROS(rate of spread) from this formula and ROSs from various equations of other models or experimental values, a trend suggesting an increasing curved line of the exponent function under 3m/s or less wind velocity condition was identified. As a result of a comparison between experimental values and numerically analyzed values for fallen pine tree leaves, the flame spread velocity reveals a prediction of an approximately 10% upward tendency under wind velocity conditions of 1 to 2m/s, and of an approximately 20% downward tendency under those of 3m/s.

A Study on Indoor Environment of Interior with Ventilation

  • Kang, Tae-Wook;Koh, Jae-Yoon
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.2
    • /
    • pp.267-274
    • /
    • 2006
  • There are no solar loads through windows and heat transfer from outer walls of the building to the interior This study analyzes indoor air temperature and air flow distribution for the interior of buildings or vessels occupying space. Numerical method is adopted to visualize the indoor side environmental situation. that is without heat transmission to outside the building in various cooling load conditions; supply ventilation lighting. occupancy and infiltration in conditioned spaces. Reaching time of an air conditioner is predicted theoretically by cooling load variations. Theoretical modelling of the reaching time shows good agreement with experimental results.

Development of Heating Technology for Greenhouse by Use of Ground Filtration Water Source Heat Pump (여과수열원 히트펌프를 이용한 온실난방기술 개발)

  • Moon, J.P.;Lee, S.H.;Kang, Y.K.;Lee, S.J.;Kim, K.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.172.2-172.2
    • /
    • 2010
  • This study was carried out in order to reduce the installation expense of heating system for greenhouse comparing to geothermal heat pump and develope the coefficient of performance (COP) for a heat pump. For getting plenty of heat flux from geothermal energy. Surface water in river channel was used for getting a lots of geothermal heat by penetrating water through underground soil layer of the river bank that make heat transmission to passing water. The range of water temperature after the process of Ground filtration is 13~18 degrees celsius which is very similar to low heat source of geothermal heat pump system and the plenty amount of heat source from that make the number of geothermal heat exchanging hole and the expense for geothermal heat exchanger construction reduced. Drainage well is also used for returning filtration water to the aquifer that keep the water good recirculation from losing geothermal heat and water resource. For the COP improvement of Heat pump, thermal storage tank with separating insulation plate according to the temperature difference make the COP of Heat pump that is similar to thermal storage tank with diffuser. Developed thermal storage tank make construction expense cheaper than customarily used one's. and that sand filter and oxidation sand (FELOX) are going to be used for improving ground filtration water quality that make heat exchanger efficiency better. All above developed component skill are going to be set on the Ground filtration water source heat pump system and applied for medium, large scale for protected greenhouse in riverside area and on-site experiment is going to do for optimizing the heating system function and overcome the problem happening in the process of on-site application afterward.

  • PDF

A study of Energy use Impacts by SHGCs of Windows in Detached House (주택 창의 SHGC가 에너지소비에 미치는 영향에 관한 연구)

  • Park, Yool;Park, Jong-Il
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.4
    • /
    • pp.189-196
    • /
    • 2010
  • U-factor and solar heat gain coefficient(SHGC) usually can be used as the index to evaluate the thermal performance. U-factor is a concept for heat loss by the temperature difference between inside and outside, so it's useful to be applied in heating season. But SHGC that indicates the fraction of heat from incident solar radiation that flows through a window by means of optical transmission, as well as absorption, re-radiation and convection is for cooling season. In other words, U-factor and SHGC of windows by cities have to be reflected to select the window of the energy conservation. The purpose of this research is to analyze the energy use impacts by SHGCs of windows for detached house in Inchon and Ulsan through energy simulation by eQUEST.

Operating Performance of Metal Hydride Heat Pump for Cooling (금속수소화물을 이용한 냉열발생형 열펌프의 성능)

  • Park, C.K.;Komazaki, Y.;Suda, S.
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.4 no.1
    • /
    • pp.21-30
    • /
    • 1993
  • The operational characteristics of a metal hydride heat pump system are strongly dependent on the amound of hydrogen gas transferred by hydriding and dehydriding reactions between the reactors under dynamic conditions. A new metal hydride heat pump combined with hydrogen compressor was constructed and the dependency of its operating conditions on such as cycle time, amount of hydrogen to be transferred between two reacting metal hydride reactors, operating temperature, and heat transmission characteristics of the reactors was investigated to find the optimum operating efficiency. These conditions were also evaluated in connection with the cooling output and hydrogen compressor connected to the system in order to enhance the total efficiency.

  • PDF

Microstructure and Mechanical Property in the Weld Heat-affected Zone of V-added Austenitic Fe-Mn-Al-C Low Density Steels

  • Moon, Joonoh;Park, Seong-Jun
    • Journal of Welding and Joining
    • /
    • v.33 no.5
    • /
    • pp.31-34
    • /
    • 2015
  • Microstructure and tensile property in the weld heat-affected zone (HAZ) of austenitic Fe-Mn-Al-C low density steels were investigated through transmission electron microscopy analysis and tensile tests. The HAZ samples were prepared using Gleeble simulation with high heat input welding condition of 300 kJ/cm, and the HAZ peak temperature of $1200^{\circ}C$ was determined from differential scanning calorimetry (DSC) test. The strain- stress responses of base steels showed that the addition of V improved the tensile and yield strength by grain refinement and precipitation strengthening. Tensile strength and elongation decreased in the weld HAZ as compared to the base steel, due to grain growth, while V-added steel had a higher HAZ strength as compared than V-free steel.

Influence of Heat-treatment Temperature on Microwave Absorbing Properities of Ni-Zn Ferrite (Zi-Zn Ferrite의 전파흡수특성에 미치는 열처리온도의 영향)

  • 조성백;권경일;최경구;김성수;김재묵
    • Journal of the Korean Ceramic Society
    • /
    • v.29 no.3
    • /
    • pp.177-182
    • /
    • 1992
  • The effect of heat-treatment temperature on the microwave absorbing properties was investigated in Ni0.8Zn0.2Fe2O4 specimens. The composite specimens were prepared by modling and curing the mixture of prereacted ferrite powder and silicone rubber. The measurement of complex permeability and permittivity was made by the reflection/transmission method. The most sensitive material constants with heat-treatment temperature is the imaginary (loss) component of permeability. The higher the heat-treatment temperature, the greater the magnetic loss. The composite specimens with high magnetic loss exhibited superior microwave absorbing properties. The quantitative estimation of microwave absorbing properties were made by plotting the observed material constants on the calculated solution map of impedance-matching.

  • PDF

The effect of heat treatment on torsion characteristics of core for transmission conductors (송전선 강심의 비틀림 특성에 미치는 열처리의 영향)

  • Kim, Jung-Hoon;Kim, Bong-Seo;Kim, Shang-Shu;Hyun, Seok-Kyu;Kim, Byung-Geol;Lee, Hee-Woong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.526-528
    • /
    • 2003
  • The effect of heat treatment on torsion characteristics of high nitrogen steel wire has been studied by using torsion test, micro vickers hardness and scanning electron microscopy. After heat treatment at $600{\sim}700^{\circ}C$, the torsion cycle was increased with increasing temperature. Especially, in case of high nitrogen steel wire heat treated at $600^{\circ}C$, the torsion cycle was sharply increased. It is estimated that the cold-worked high nitrogen steel wire started to recrystallize around at $650^{\circ}C$ in air atmosphere.

  • PDF