Heat and Material Transport Analysis on the Head of Vehicle along the Flight Trajectory (비행궤적에 따른 비행체 앞부분의 열 및 물질전달해석)

  • 서정일;송동주
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.5 no.4
    • /
    • pp.88-96
    • /
    • 2002
  • The CSCM Upwind method and Material Transport Analysis(MTA) have been used to predict the thermal response and shape changes for charring/non-charring material which can be used as thermal protection material(TPM) on blunt-body nose tip. We performed intensive flight trajectory simulations to compare 1-D MTA results with those of 2-D/Axisymmetric MTA by using MTAs and Navier-Stokes code. Theheat-transfer rate and pressure distribution were predicted at selected altitudes and wall temperature along the flight trajectory and the shape changes of blunt-body nose tip were predicted subsequently by using current procedure.

Operating Characteristics of LNG burner for Steam Reforming of Natural Gas (천연가스 수증기개질 반응용 LNG 버너의 운전 특성)

  • Shin, Jang-Sik;Park, Jong-Won;Yang, Hye-Kyong;Lee, Seung-Young;Song, Bong-Hyun;Shin, Seock-Jae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.477-480
    • /
    • 2006
  • In this study, we investigated operating characteristics of the LNG burner for steam methane reforming. The developed LNG burner and catalytic reactor to supply an efficient heat transfer between the combustion gas and catalyst got a good response of various operating load within 5-7 minute and high efficiency for steam methane reforming as a conversion of methane over 90%. We calculated the volume of catalyst for $1Nm^3/hr$ steam LNG reforming as $211cc/(Nm^3/hr\;H_2)$ and got the operating condition and design data of the burner and steam reforming for LNG.

  • PDF

Analysis of Surface Fibers by Wavelet Transform and Subjective Evaluation of Wool Fabrics (웨이블릿 변환을 이용한 모직물의 표면섬유 분석과 주관적 감각 평가)

  • 김동옥;김은애;유신정
    • Science of Emotion and Sensibility
    • /
    • v.5 no.3
    • /
    • pp.53-59
    • /
    • 2002
  • The surface fibers on the fabric is one of decisive factors which affects human sensory evaluation as well as heat and moisture transfer characteristics. In this study the length and distribution of surface fibers that are extruded from the fabric surface of the wool/wool blend fabrics (14 wool fabrics and 10 wool blend fabrics) and its contribution to subjective sensory evaluation were investigated. In order to quantify the length and distribution of surface fibers, image analysis and wavelet transform technique were introduced. Instant warm-cool feeling of touch, Q$\_$max/, and contact area were also measured and related to the quantified surface fibers. To figure out the effect of surface characteristics on sensory evaluation, human sensory responses to three adjectives which represent surface characteristics and warm-cool feeling of touch were obtained and analyzed. The relationship between the quantified surface fibers assessed by wavelet energy and both warm-cool reeling of touch, Qmax, and human sensory response were discussed.

  • PDF

Numerical Simulation on Thermoacoustic Instability in the Dump Combustor (덤프 연소기에서의 열음향 불안정에 관한 수치적 연구)

  • Kim, Hyeon-Jun;Bae, Soo-Ho;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.294-301
    • /
    • 2005
  • The instabilities in rocket engines and gas turbine combustors due to the interaction between the fluid flow (acoustics) and the heat transfer (thermal energy) are called thermoacoustic or combustion instabilities. Almost all analysis assumes constant hot section temperature for Modern mathematical analysis of acoustic oscillations in Rijke type devices. However, it is impossible to predict whether a system is stable or not because the flame or heater response model can have a dramatic effect on predicted growth rates. In this study, A standard ${\kappa}-{\varepsilon}$ turbulent model and hybrid combustion model(eddy breakup model and chemical reaction) were used. After steady solution was gotten, unsteady calculation is simulated by perturbating on pressure boundary. As a result, we obtained the relationship of equivalence ratio and frequency by numerical simulation, and they are comparable to the experimental result. In addition, in spite of these results, there are limitations of using turbulent and combustion model in simulation method of thermoacoutic instability

  • PDF

Evaluation of Thermal Comfort in Task Area with Personal Air-Conditioning System(PACS) b PMV Index (PMV 지표에 의한 개별 공조시스템(PACS)의 쾌적성 평가에 관한 연구)

  • 최익순;정광섭;박영칠;한화택;이정재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.7
    • /
    • pp.647-652
    • /
    • 2001
  • The thermal comfort of indoor spaces is very important factor in our life. Regions, cultures, climates and individual difference for establishing thermally comfortable environments should be considered carefully because these factors have a large influence on the thermal comfort doing some complicated interactions with environmental, psychological and physical elements. Recently, predicted mean vote(PMV) based on the heat transfer theory between environmental factors and human bodies has evaluated by many researchers and widely used nowadays. The objective of this study is to evaluate the thermal comfort in workspaces with personal air conditioning system using the measurements of environmental comfort parameters and the questionnaire survey of occupant's thermal senses with response to the environment.

  • PDF

Development of Thermal Type Fluid Level Transmitter for Water Level Measurement of Containment Building in Nuclear Power Plant (원자력 발전소 격납 건물의 수위 측정을 위한 열식 레벨 측정기 개발)

  • Yoon, Joon-Yong;Seong, Nak-Won;Lee, Chul-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.404-410
    • /
    • 2001
  • A new thermal type fluid level transmitter was designed and tested at the HITROL R&D institute. The relation of heat transfer and electric resistance was adopted as an operation principle. The length of a fabricated level transmitter was two meters and a water under normal temperature was used as a working fluid for the experiment Finally, the new product could have a high precision, acceptable accuracy and reasonable response time. Foreign-made level transmitter of this type is under in use for measuring water level of containment building in nuclear power plants so far. It is expected that new product will substitute it.

  • PDF

A PID Control of Electric Heater for PEM (개별공조시스템을 위한 전기히터의 PID 제어)

  • 장영준;박영칠;정광섭;한화택;이정재
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.1
    • /
    • pp.59-65
    • /
    • 2001
  • The work presented here is an implementation of PID control to achieve a required supply air temperature in PEM(Personal environment module). In PEM, the air is heated to the required temperature while it flows through the supply duct, without any mixing chamber. This makes the control of air temperature in PEM difficult. Linear dynamic model of heat transfer in PEM is first obtained. Then P, PD and PID type control systems, to provide the rapid response without overshoot and saturation, are designed and implemented experimentally. Data obtained shows that the control system satisfied the design criteria and works properly in controlling the supply air temperature.

  • PDF

Interaction of High-Speed Compressible Viscous Flow and Structure by Adaptive Finite Element Method

  • Limtrakarn, Wiroj;Dechaumphai, Pramote
    • Journal of Mechanical Science and Technology
    • /
    • v.18 no.10
    • /
    • pp.1837-1848
    • /
    • 2004
  • Interaction behaviors of high-speed compressible viscous flow and thermal-structural response of structure are presented. The compressible viscous laminar flow behavior based on the Navier-Stokes equations is predicted by using an adaptive cell-centered finite-element method. The energy equation and the quasi-static structural equations for aerodynamically heated structures are solved by applying the Galerkin finite-element method. The finite-element formulation and computational procedure are described. The performance of the combined method is evaluated by solving Mach 4 flow past a flat plate and comparing with the solution from the finite different method. To demonstrate their interaction, the high-speed flow, structural heat transfer, and deformation phenomena are studied by applying the present method to Mach 10 flow past a flat plate.

Dynamic Simulation of Annual Energy Consumption in an Office Building by Thermal Resistance-Capacitance Method

  • Lee, Chang-Sun;Choi, Young-Don
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.6
    • /
    • pp.1-13
    • /
    • 1998
  • The basic heat transfer process that occurs in a building can best be illustrated by an electrical circuit network. Present paper reports the dynamic simulation of annual energy consumption in an office building by the thermal resistance capacitance network method. Unsteady thermal behaviors and annual energy consumption in an office building were examined in detail by solving the simultaneous circuit equations of thermal network. The results are used to evaluate the accuracy of the modified BIN method for the energy consumption analysis of a large building. Present thermal resistance-capacitance method predicts annual energy consumption of an office building with the same accuracy as that of response factor method. However, the modified BIN method gives 15% lower annual heating load and 25% lower cooling load than those from the present method. Equipment annual energy consumptions for fan, boiler and chiller in the HVAC system are also calculated for various control systems as CAV, VAV, FCU+VAV and FCU+CAV. FCU+CAV system appears to consume minimum annual energy among them.

  • PDF

Design of a New 2-DOF PID Controller for Gun-san Gas Turbine Generation Plant

  • Kim, Dong-Hwa
    • Journal of KIEE
    • /
    • v.10 no.1
    • /
    • pp.16-22
    • /
    • 2000
  • The Main role of the gas turbine lies in the utilization of waste heat which may be found in exhaust gases from the gas turbine or at some other points of the process to produce additional electricity. Up to date, the PID controller has been used to operate under such difficult conditions, but since the gain of PID controller manually experience. In this paper parameter separation type 2-DOF PID controllers are proposed based on the gas turbine control system. Gas turbine transfer function is achieved from operation data of Gun-san gas turbine and Tuning algorithms of parameter separation type 2-DOF PID controller is ANFIS. Results represents satisfactory response.

  • PDF